NXP Semiconductors

MPX2102D - 100kPa Differential Pressure Sensor | NXP | 4-SIP Module

N.º da peça: MPX2102D ✗ Fim de vida
Em estoque Enviado em 1 a 3 dias úteis
0 mV to 40 mV (at 10 V supply) Vdss 4-SIP Module Package
A partir de $13.1 USD / unidade
MOQ: 1 |
Preço atualizado: 2026-10-15
Preços por volume
Qtd. Preço unitário Total
1 $24.5 $24,50
10 $21.75 $217,50
100 $18.2 $1.820,00
500 $15.4 $7.700,00
1.000 $13.1 $13.100,00
ℹ️ Todos os preços estão em USD

MPX2102D Visão geral

The NXP MPX2102D is a 100 kPa on-chip temperature-compensated silicon piezoresistive pressure sensor housed in a 4-SIP through-hole module. The device delivers a highly accurate, linear Wheatstone Bridge analog voltage output of 0 mV to 40 mV at a 10 V excitation supply, directly proportional to the applied pressure. According to the NXP datasheet, the MPX2102D is rated for a 14.5 PSI (100 kPa) differential pressure operating range and is calibrated directly on the die for high accuracy.

A piezoresistive pressure sensor is a MEMS device that converts applied mechanical pressure into a proportional electrical signal using strain-sensitive resistors embedded in a silicon diaphragm. When pressure deforms the diaphragm, the embedded Wheatstone bridge resistors change resistance, producing a differential output voltage. Piezoresistive sensors such as the MPX2102D sit at the bottom of the sensor hierarchy: pressure sensor -> MEMS sensor -> transducer -> sensor IC. They are widely used where continuous analog pressure monitoring is required rather than a simple threshold switch.

Key features of the MPX2102D include on-chip temperature compensation from 0 C to +85 C, a 0 mV to 40 mV full-scale output, a typical full-scale span of 40 mV at 10 V supply, low offse drift, and a rugged unibody 4-SIP package with dual pressure ports for differential measurement. The integrated signal conditioning and calibration performed at the wafer level eliminate the need for external compensation networks, simplifying downstream amplifier design.

The die uses a piezoresistive Wheatstone bridge configured for differential pressure sensing, with a separate reference port exposed on the side of the 4-SIP module opposite the high-pressure port. The on-chip laser-trimmed resistors provide temperature compensation across the rated range, which is essential because raw silicon piezoresistors exhibit strong temperature coefficients that would otherwise degrade measurement accuracy.

Typical applications include HVAC airflow monitoring, medical respiration and anesthesia equipment, industrial process control, altimeters and barometric instrumentation, and pneumatic control systems. Its differential measurement capability also makes it well-suited to liquid-level sensing via hydrostatic pressure.

When designing with the MPX2102D, ensure that the 10 V excitation supply is well-regulated because output accuracy scales linearly with supply voltage. The Wheatstone bridge output is in the millivolt range and typically requires an instrumentation amplifier such as the INA128 or AD620 before the ADC input. Differential measurements should use both pressure ports and avoid clogging either with particulates.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet alone.

Alternativas drop-in para MPX2102D — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Variantes desta série

Modelos da mesma série compatíveis como drop-in com MPX2102D (mesmo formato e footprint) — diferindo em Output Type, Operating Pressure Range, Mounting Type, Pressure Type, Package / Case.

STMicroelectronics
Output Type: Analog Wheatstone Bridge (mV)
Operating Pressure Range: 0 kPa to 10 kPa (0 PSI to 1.45 PSI)
Mounting Type: Through-Hole
Comparar com MPX2102D →
NXP Semiconductors
Output Type: Analog voltage (Wheatstone bridge, differential)
Operating Pressure Range: 20 kPa to 100 kPa
Mounting Type: Through-Hole (SIP)
Comparar com MPX2102D →
STMicroelectronics
Output Type: Analog Wheatstone Bridge
Operating Pressure Range: 14.5 PSI (100 kPa)
Mounting Type: Through-Hole
Comparar com MPX2102D →
NXP Semiconductors
Output Type: Analog Wheatstone Bridge (ratiometric mV)
Operating Pressure Range: 0 kPa to 100 kPa (0 PSI to 14.5 PSI)
Mounting Type: Through-Hole, Dual Vertical Port
Comparar com MPX2102D →
NXP Semiconductors
Output Type: Analog, ratiometric
Operating Pressure Range: 0 kPa to 10 kPa (0 to 1.45 PSI)
Mounting Type: Through-hole (SIP)
Comparar com MPX2102D →

Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:

MPX2102A

✅ Drop-In
NXP Semiconductors
📦 4-SIP Module
Absolute · 20 kPa to 100 kPa · Analog voltage (Wheatstone bridge, differential) · 0 mV to 40 mV at 10 V supply · 10 V typical · -40C to +125C

✓ Em estoque

$10.95 / unidade

Ver ficha técnica →

MPX2102AP

✅ Drop-In
STMicroelectronics
📦 4-SIP Module
Absolute · 14.5 PSI (100 kPa) · 14.5 PSI (100 kPa) · Male - 0.19" (4.93 mm) Tube · Analog Wheatstone Bridge · 0 mV to 40 mV at 10 V excitation · 10 V (typical ratiometric) · ±0.5% (typ)

✓ Em estoque

$9.5 / unidade

Ver ficha técnica →

MPX2102DP

✅ Drop-In
NXP Semiconductors
📦 4-SIP Module
Piezoresistive Pressure Sensor · Differential (Dual Port) · 0 kPa to 100 kPa (0 PSI to 14.5 PSI) · 0 mV to 40 mV at 10 V excitation · 10 V typical (max specified separately) · Male, 0.19" (4.93 mm) tube, Dual · -40 °C to +125 °C · 0 °C to +85 °C

✓ Em estoque

$9.85 / unidade

Ver ficha técnica →

MPXV2102G

✅ Drop-In
📦 4-SIP Module
gauge-port variant; same 100 kPa, 40 mV output, 10 V supply; same 4-SIP unibody package

📋 Alternativa de referência (fora do catálogo)

MPX2010D

✅ Drop-In
STMicroelectronics
📦 4-SIP Module
Differential (Port 1 vs Port 2) · 0 kPa to 10 kPa (0 PSI to 1.45 PSI) · Analog Wheatstone Bridge (mV) · 0 mV to 25 mV at 10V excitation · 2.5 mV/kPa (nominal, at 10V excitation) · 10 V (typical), 16 V (maximum) · 0.1% of full-scale (typical)

✓ Em estoque

$9.1 / unidade

Ver ficha técnica →

MPX5010DP

✅ Drop-In
NXP Semiconductors
📦 6-SIP Module (compatible SIP outline)
Differential · 0 kPa to 10 kPa (0 to 1.45 PSI) · 450 mV/kPa (typical) · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V typical) · ±1.5% VFSS (typical, 0-85 C)

✓ Em estoque

$9.6 / unidade

Ver ficha técnica →

MPX2102D Classificações máximas e características elétricas

Operating Pressure 14.5 PSI (100 kPa)
Pressure Type Differential
Tipo de saída Wheatstone Bridge (Analog Voltage)
Tensão de saída 0 mV to 40 mV (at 10 V supply)
Tensão de alimentação 10 V typical
Encapsulamento / Caixa 4-SIP Module
Port Size Female, 0.136 in (3.4544 mm)
Termination Style Through-Hole PCB
Tipo de montagem Through Hole
Applications Board Mount
Temperatura de operação -40 C to +125 C (per NXP MPX2102 series datasheet)
Compensated Temperature 0 C to +85 C
Housing / Body Style Unibody Plastic (Round)
Technology Piezoresistive Silicon MEMS
Series MPX2102
Packaging Tray
Product Status Obsolete (per distributor listings)

Configuração de pinos do MPX2102D

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pino 1 VCC — Bridge excitation supply (10 V typical)
Pino 2 VOUT+ — Positive bridge output
Pino 3 GND — Bridge ground reference
Pino 4 VOUT- — Negative bridge output

Aplicações típicas

MPX2102D é adequado para 6 aplicaçãos: HVAC Airflow and Duct Pressure Monitoring, Medical Respiration and Anesthesia Equipment, Industrial Process Control and Pneumatic Systems, Altimeters and Barometric Instrumentation, Liquid-Level Sensing via Hydrostatic Pressure, Portable Gas Flow and Leak Detection.

🏭

HVAC Airflow and Duct Pressure Monitoring

The MPX2102D's 100 kPa differential rating and millivolt Wheatstone bridge output make it suitable for HVAC duct static pressure and airflow monitoring. Differential measurement across an orifice plate or Pitot tube captures airflow-induced pressure drop with high linearity across the 0 to 100 kPa span. The on-chip 0 C to +85 C temperature compensation keeps the sensor stable across the typical HVAC operating envelope, while the unibody 4-SIP package withstands the temperature and humidity swings found in air-handling plenums. A typical signal chain pairs the MPX2102D with an INA128 instrumentation amplifier and a 24-bit ADC for low-noise pressure digitization in building-automation controllers.

💊

Medical Respiration and Anesthesia Equipment

The MPX2102D's 100 kPa range covers airway pressures encountered in ventilators, CPAP machines, and anesthesia circuits where peak inspiratory pressures rarely exceed 60 mbar to 80 mbar. The differential configuration allows reference-port sensing against ambient, so the circuit measures true gauge pressure without an external reference. The silicon piezoresistive die offers the long-term stability required for medical instrumentation, and the on-chip temperature compensation minimizes drift across the clinical environment. Biocompatibility for the patient side is handled via tubing and bacterial filters, while the unibody module mounts directly on the equipment chassis.

🏭

Industrial Process Control and Pneumatic Systems

Factory automation systems that monitor compressed-air lines, hydraulic pressures, and vacuum levels are well served by the MPX2102D's 100 kPa span. The rugged unibody 4-SIP housing tolerates the vibration and temperature gradients common in industrial cabinets, and the through-hole mounting survives factory-floor handling during service. The differential output lets the system measure positive line pressure against a vented reference port, simplifying plumbing on a control panel. Plant operators typically pair the MPX2102D with a 4-20 mA transmitter board so the signal can travel long distances without EMI pickup.

✈️

Altimeters and Barometric Instrumentation

The MPX2102D's 100 kPa range corresponds to approximately 0 to 10,000 meters of altitude when used as a barometer, covering most recreational, drone, and weather-station applications. Differential measurement against a sealed reference is impractical outdoors, but the absolute-pressure MPX2102A variant shares the same die and footprint. Designers typically compensate the altitude reading in firmware using the barometric formula plus a temperature sensor for highest accuracy. Low-power consumption makes the part attractive for battery-operated weather stations and balloon payloads.

🌐

Liquid-Level Sensing via Hydrostatic Pressure

The MPX2102D can measure liquid levels in tanks and reservoirs by sensing the hydrostatic pressure at the bottom of the column, where 100 kPa spans about 10 meters of water. The differential port configuration allows reference-port venting to atmospheric pressure, eliminating barometric drift. Industrial and agricultural tanks benefit from the unibody 4-SIP package's chemical resistance when used with compatible tubing. Designers should still add a vented cable and a moisture barrier for outdoor installations, and they typically pair the bridge output with a low-offset instrumentation amp.

⚡

Portable Gas Flow and Leak Detection

Handheld gas-flow analyzers and leak detectors use the MPX2102D's 100 kPa differential range to measure small pressure drops across flow elements. Millivolt resolution from the Wheatstone bridge is well suited to detecting sub-Pa changes when the signal chain includes a high-gain, low-noise amplifier. Battery-operated designs benefit from the predictable ratiometric output, which scales with supply voltage and supports low-duty-cycle excitation to conserve power. The through-hole 4-SIP package is robust enough to survive repeated field use in service-truck environments.

Resumo dos produtos recomendados

INA128 Low-noise instrumentation amplifier for bridge signal conditioning Usado em: HVAC Airflow and Duct Pressure Monitoring, Liquid-Level Sensing via Hydrostatic Pressure ADS131A04 24-bit ADC for simultaneous pressure and temperature digitization Usado em: HVAC Airflow and Duct Pressure Monitoring AD620 Low-drift instrumentation amplifier for medical pressure signal chain Usado em: Medical Respiration and Anesthesia Equipment, Portable Gas Flow and Leak Detection MAX11131 12-/14-bit SAR ADC for portable medical designs Usado em: Medical Respiration and Anesthesia Equipment XTR105 4-20 mA current-loop transmitter for industrial pressure sensors Usado em: Industrial Process Control and Pneumatic Systems INA333 Low-power zero-drift instrumentation amplifier for loop-powered designs Usado em: Industrial Process Control and Pneumatic Systems BMP280 Digital-output barometric pressure sensor for new low-power designs Usado em: Altimeters and Barometric Instrumentation MAX31865 RTD-to-digital converter for temperature compensation Usado em: Altimeters and Barometric Instrumentation MAX11270 24-bit low-power delta-sigma ADC for precision level sensing Usado em: Liquid-Level Sensing via Hydrostatic Pressure ADS1118 16-bit delta-sigma ADC with integrated temperature sensor Usado em: Portable Gas Flow and Leak Detection
What is the operating pressure range of the MPX2102D?
The MPX2102D is rated for a maximum operating pressure of 14.5 PSI (100 kPa) differential. According to the NXP MPX2102 datasheet, this is the on-chip calibrated full-scale span; applying pressures beyond this range risks permanent diaphragm damage. Use this rating as the design limit rather than the typical operating point for best sensor longevity.
What is the output voltage of the MPX2102D at full-scale pressure?
The MPX2102D outputs approximately 40 mV differential at full-scale 100 kPa pressure with a 10 V excitation supply, per the NXP datasheet. The bridge output is ratiometric with the supply voltage, so any drift in the excitation source directly translates into measurement error. A low-noise, well-regulated 10 V supply is essential for accurate readings.
Is the MPX2102D obsolete or still in production?
Yes, the MPX2102D is listed as Obsolete on current distributor pages including DigiKey and Mouser, per Verified Web Data from October 2026. NXP has migrated the MPX series to newer parts with integrated signal conditioning. Engineers building new designs should evaluate the MPX5010, MPX5500, or a modern digital-output alternative for new production.
What is the supply voltage requirement for the MPX2102D?
The MPX2102D is specified for a 10 V typical excitation supply, per the NXP MPX2102 datasheet. Because the Wheatstone bridge output is ratiometric, supply accuracy directly impacts measurement accuracy. Use a low-dropout regulator with tight line regulation, or a precision reference, to drive the bridge for repeatable readings.
What package does the MPX2102D use?
The MPX2102D ships in a 4-SIP through-hole module with a round plastic unibody housing, per the NXP datasheet and DigiKey listing. It exposes two ports on opposite sides for differential pressure measurement, plus four through-hole leads. This classic unibody package has been the de facto standard for the MPX family for decades.
Where can I download the MPX2102D datasheet PDF?
The MPX2102D datasheet is hosted at https://www.nxp.com/docs/en/data-sheet/MPX2102.pdf as an NXP product document. The same document covers the entire MPX2102 family including the MPX2102D, MPX2102A, MPX2102AP, and gauge variants. The alldatasheet.com mirror also hosts a PDF scan of the original Freescale document.
What is the difference between MPX2102D and MPX2102A?
The MPX2102D is the differential-pressure variant of the MPX2102 series, while the MPX2102A is an absolute-pressure variant that references a sealed vacuum cavity on the back side of the die. Both share the same 100 kPa full-scale span, 40 mV output, and 10 V excitation, but their porting and reference configuration differ. Use MPX2102D for differential measurements and MPX2102A for sealed gauge / absolute readings.
What can replace the MPX2102D in an existing design?
The MPX2102D is obsolete, so engineers maintaining legacy designs typically migrate to the MPX5010DP (differential, 10 kPa, integrated signal conditioning) or the MPX5500DP (differential, 500 kPa, integrated). Per the NXP cross-reference tool, these are drop-in mechanical replacements on the same port layout but require re-calibration because of the integrated amplifier stage. For brand-neutral options, Honeywell 24PC series and TE Connectivity 154N are drop-in pin-compatible alternatives.
Does the MPX2102D include temperature compensation?
Yes, the MPX2102D includes on-chip temperature compensation over the 0 C to +85 C range, per the NXP MPX2102 datasheet. Laser-trimmed resistors on the die compensate the bridge for thermal drift. For systems operating outside the compensated range, external software compensation using a temperature sensor is recommended for high-accuracy applications.
How does the MPX2102D compare to the MPX5010?
The MPX2102D outputs 0 to 40 mV raw bridge output and requires external amplification, while the MPX5010DP integrates a signal-conditioning stage and outputs a 0 to 5 V analog signal with the same differential porting. The MPX5010 also operates from a single 5 V supply instead of 10 V. For new designs, the MPX5010 is generally preferred because it eliminates the instrumentation amplifier stage.
What is the lead time for MPX2102D orders?
Because the MPX2102D is obsolete, lead times are highly variable and depend on remaining distributor stock, per Verified Web Data from October 2026. Authorized NXP distributors may show zero stock and a Last Time Buy status. For new production, select the MPX5010DP or MPX5500DP instead to avoid supply-chain disruption.
What is the price of the MPX2102D?
As of October 2026, the MPX2102D price is approximately USD 24.50 at qty 1 from authorized distributors, per Verified Web Data. Bulk pricing drops to roughly USD 13.10 at qty 1000. Because the part is obsolete, distributors occasionally list it above the historical price, so checking multiple sources before placing a production order is recommended.
Is the MPX2102D RoHS compliant?
The MPX2102D lead-free / RoHS status is not explicitly listed on the Verified Web Data sources reviewed; consult the NXP product page or your distributor for the latest compliance certificate. The MPX2102 series predates the EU RoHS directive, so older date-code inventory may be non-compliant. Always verify the date code and RoHS marking on the shipping reel before commissioning for a new design.
What instrumentation amplifier pairs well with the MPX2102D?
The MPX2102D's 40 mV full-scale output pairs well with a low-offset, low-drift instrumentation amplifier such as the Texas Instruments INA128, Analog Devices AD620, or Texas Instruments INA333. Choose a gain of around 50 to map the 0 to 40 mV signal to a 0 to 2 V or 0 to 5 V ADC input range. Select an instrumentation amp with low 1/f noise for HVAC or respiration applications.
Can I use the MPX2102D with a 3.3 V microcontroller ADC?
No, the MPX2102D requires a 10 V excitation supply and outputs a millivolt-level signal, per the NXP datasheet, so it cannot be connected directly to a 3.3 V microcontroller ADC. You must add a precision 10 V supply, an instrumentation amplifier for signal conditioning, and a 3.3 V-compatible reference for the ADC. A modern integrated sensor such as the MPXV5010DP or BMP280 is generally a better choice for 3.3 V designs.

Dados de referência de engenharia para MPX2102D — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the MPX2102D only when maintaining or repairing existing designs that require a drop-in differential 100 kPa pressure sensor with raw Wheatstone bridge output - the part is obsolete and not recommended for new designs. For new 100 kPa differential measurements, prefer the integrated MPX5500DP (500 kPa, 0-5 V output, 5 V supply). For lower-pressure 10 kPa measurements with integrated conditioning, the MPX5010DP is the standard choice. For absolute pressure, the MPX2102A shares the same die but uses a sealed vacuum reference. For brand-neutral alternatives, the Honeywell 24PC series or TE Connectivity 154N family provide drop-in replacements with similar pinout and electrical characteristics, though mechanical porting may differ.

Comparação com alternativas

Parâmetro Este produto MPX2102A MPX2102AP MPX2102DP MPXV2102G MPX2010D MPX5010DP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 4-SIP Module 4-SIP Module 4-SIP Module 4-SIP Module 4-SIP Module 4-SIP Module 6-SIP Module
Operating Pressure 14.5 PSI (100 kPa) 14.5 PSI (100 kPa) 14.5 PSI (100 kPa) 14.5 PSI (100 kPa) 14.5 PSI (100 kPa) 1.45 PSI (10 kPa) 1.45 PSI (10 kPa)
Pressure Type Differential Absolute Absolute, ported Differential, ported Gauge Differential Differential, ported
Output Type Wheatstone Bridge, 0-40 mV Wheatstone Bridge, 0-40 mV Wheatstone Bridge, 0-40 mV Wheatstone Bridge, 0-40 mV Wheatstone Bridge, 0-40 mV Wheatstone Bridge, 0-25 mV Conditioned, 0-5 V
Supply Voltage 10 V 10 V 10 V 10 V 10 V 10 V 5 V
Compensated Temperature 0 C to +85 C 0 C to +85 C 0 C to +85 C 0 C to +85 C 0 C to +85 C 0 C to +85 C -40 C to +125 C
Lifecycle Status Obsolete Obsolete Obsolete Obsolete Obsolete Obsolete Active

Principais diferenciais

  • Raw Wheatstone bridge output for direct signal-chain integration (vs MPX5010DP)
  • Differential measurement against a vented reference port (vs MPX2102A)
  • Industry-standard 4-SIP unibody package (vs MPXV2102G)

Notas de projeto

The MPX2102D Wheatstone bridge output is ratiometric with the 10 V excitation supply, so any drift or ripple on the excitation directly translates into measurement error. Estimated: a 100 mV ripple on the 10 V supply introduces roughly 0.4 mV of bridge output noise, which at a 40 mV full-scale span is 1% full-scale error. Use a low-dropout regulator such as the LT3042 or a precision 10 V reference to drive the bridge for repeatable readings, and add 100 nF ceramic decoupling close to the bridge pins to suppress high-frequency noise.

The MPX2102D outputs a 40 mV differential signal that is vulnerable to common-mode noise, especially in industrial environments with motors or solenoid drivers. Use a true differential instrumentation amplifier (INA128, AD620, or INA333) rather than a single-ended op-amp configuration. Twisted-pair wiring from the sensor to the amplifier, plus a guard ring on the PCB, will reject coupled noise. For long cable runs, route the bridge output through shielded cable to avoid 50/60 Hz pickup from adjacent power conductors.

The 4-SIP module is through-hole mounted, so plan the PCB layout around the lead spacing and the dual-port housing. Estimated: the package body occupies roughly 12 mm x 9 mm of board area and requires at least 6 mm of additional clearance for the side port. Keep the bridge excitation and output traces short and parallel, and place a 100 nF decoupling capacitor within 5 mm of the VCC pin. Use a ground plane and avoid routing noisy digital signals directly beneath the sensor body.

Do not apply pressure exceeding 14.5 PSI (100 kPa) to the MPX2102D - the die will permanently deform and the output will be uncalibrated. Estimated: the burst pressure of a typical MPX2102-series die is roughly 2x to 3x the rated full-scale, so a 1.5x overpressure event can shorten the service life. Add a mechanical pressure snubber or a software alarm when the application can spike above the rated range. Also remember that differential pressure sensors measure the difference between the two ports - blocking one port turns the device into a sealed gauge reference, which is rarely the intent in circuit design.

Informações de conformidade

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sem chumbo
Unknown
Sem halogênios
Unknown
Minerais de conflito
Unknown

Compliance status not explicitly listed in the Verified Web Data sources reviewed. The MPX2102 family predates RoHS, so older date-code inventory may be non-compliant. Verify RoHS and lead-free markings on the shipping reel before commissioning for a new design.

Dados verificados em: 2026-10-15 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

MPX2102D MPX2102D datasheet NXP MPX2102D pressure sensor 100 kPa differential pressure sensor 4-SIP MPX2102D pinout MPX2102D HVAC duct pressure MPX2102D vs MPX5010 MPX2102D obsolete replacement MPX2102D buy price wheatstone bridge pressure sensor 10V supply piezoresistive silicon pressure sensor SIP MPX2102D drop-in replacement Honeywell

Componentes & termos relacionados

NXP Semiconductors MPX2102D MPX2102A MPX2102AP MPX2102DP MPXV2102G MPX2010D MPX5010DP piezoresistive pressure sensor silicon pressure sensor Wheatstone bridge MEMS sensor differential pressure sensor absolute pressure sensor gauge pressure sensor 4-SIP module unibody package instrumentation amplifier INA128 AD620 RoHS barometric pressure altimeter ventilator / CPAP HVAC airflow
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
Total: $0.00 USD
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ