MPX2202GP Visão geral

The NXP MPX2202GP is a 200 kPa on-chip temperature-compensated silicon piezoresistive pressure sensor in a 4-SIP top-port module, delivering a linear 0 mV to 40 mV output scaled to the 10V excitation supply. It is a gauge-type sensor with a male 0.19" (4.93 mm) tube port and is targeted at medical, industrial, and consumer pressure measurement up to 29.01 PSI (200 kPa).

A piezoresistive pressure sensor is a MEMS device in which a diaphragm with embedded strain gauges changes resistance proportionally to applied differential pressure; the MPX2202GP integrates on-chip signal conditioning and temperature compensation so the user only applies 10 V DC excitation and reads a ratiometric millivolt signal. Within the broader sensor taxonomy, this part sits in the hierarchy: pressure sensor -> piezoresistive pressure sensor -> silicon strain-gauge sensor -> MEMS sensor -> transducer, and the 4-SIP package belongs to the through-hole SIP (Single Inline Package) family used predominantly for legacy and industrial pneumatic interfaces.

Key features include 0 mV to 40 mV full-scale output (10 V supply), 0 to 200 kPa operating range, on-chip temperature compensation and calibration, gauge (vented) reference, and linear response directly proportional to applied pressure. The integrated compensation network eliminates the need for external trim circuitry, simplifying host-microcontroller or A/D front-end designs.

The device is built on a silicon die using a diffused piezoresistive Wheatstone-bridge topology, with the four bridge resistors laser-trimmed during wafer-level test. The 4-SIP top-port housing routes incoming pressure through a tube stub to the diaphragm side of the die while the back side vents to the reference (ambient) via the package's secondary port, producing a true gauge output.

Typical applications include medical patient monitoring (blood pressure, respiratory), HVAC air-flow and duct pressure sensing, industrial pneumatic control, altimeters and barometric instruments, and consumer appliance pressure monitoring. The 4-SIP top-port geometry suits manifolds and enclosures where pressure tubing enters vertically.

A key design consideration is that the output is ratiometric with the 10 V supply: any supply noise directly couples into the output, so a low-noise, low-drift excitation regulator is required to realize the datasheet accuracy. Dry air or non-corrosive gases are the only verified media; aggressive media require factory consultation.

This page synthesizes distributor pricing, drop-in alternatives (MPX2202DP, MPX2202AP, MPX2102GP), and practical design notes not found in the standalone datasheet.

Alternativas drop-in para MPX2202GP — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Variantes desta série

Modelos da mesma série compatíveis como drop-in com MPX2202GP (mesmo formato e footprint) — diferindo em Mounting Type, Output Type, Pressure Type, Package / Case, Operating Pressure Range.

STMicroelectronics
Mounting Type: Through-Hole
Output Type: Analog Wheatstone Bridge
Pressure Type: Absolute
Comparar com MPX2202GP →
NXP Semiconductors
Mounting Type: Through-Hole SIP
Operating Pressure Range: 0 kPa to 100 kPa (0 PSI to 14.5 PSI)
Comparar com MPX2202GP →
STMicroelectronics
Mounting Type: Through-Hole
Output Type: Analog Wheatstone Bridge
Package / Case: 4-SIP Module (4-344C)
Comparar com MPX2202GP →
NXP Semiconductors
Mounting Type: Through-hole, PCB mount
Output Type: Wheatstone bridge, analog ratiometric
Pressure Type: Absolute
Comparar com MPX2202GP →
NXP Semiconductors
Mounting Type: Through-Hole
Output Type: Analog Voltage (Wheatstone bridge differential)
Pressure Type: Absolute (vs. sealed vacuum reference)
Comparar com MPX2202GP →
NXP Semiconductors
Output Type: Wheatstone Bridge (analog voltage)
Pressure Type: Differential
Package / Case: 4-SIP Module (unibody, through-hole)
Comparar com MPX2202GP →
NXP Semiconductors
Mounting Type: Through-hole (4-SIP tube inlet)
Output Type: Analog differential voltage
Pressure Type: Differential (dual port, tube inlet)
Comparar com MPX2202GP →
NXP Semiconductors
Mounting Type: Surface Mount, dual port top-side
Output Type: Analog ratiometric voltage
Pressure Type: Differential (dual ports, same side)
Comparar com MPX2202GP →
NXP Semiconductors
Mounting Type: Surface Mount
Output Type: Analog voltage (ratiometric, differential bridge)
Operating Pressure Range: 0 kPa to 200 kPa (0 psi to 29.01 psi)
Comparar com MPX2202GP →

Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:

MPX2202DP

✅ Drop-In
NXP Semiconductors
📦 4-SIP Top Port Module
0 to 200 kPa (0 to 29.01 PSI) · Differential (dual port, tube inlet) · 10 V typical · 40 mV typical at 10 V supply · 0 mV typical · 1.0% typical · 2.0% maximum · 0 C to 85 C

✓ Em estoque

$25.14 / unidade

Ver ficha técnica →

MPX2202AP

✅ Drop-In
NXP Semiconductors
📦 4-SIP Top Port Module
Absolute · 0 to 29.01 PSI (0 to 200 kPa) · 0 mV to 40 mV (typ) at 10 V excitation · 10 V (typical), max 16 V · Wheatstone bridge, analog ratiometric · ±0.25% (typ), ±1.0% (max) · ±1.0% max

✓ Em estoque

$6.85 / unidade

Ver ficha técnica →

MPX2200GP

✅ Drop-In
STMicroelectronics
📦 4-SIP Top Port Module
STMicroelectronics · Pressure Sensor - Vented Gauge · 0 kPa to 200 kPa (0 to 29.01 PSI) · Male - 0.19 inch (4.93 mm) Tube · Analog Wheatstone Bridge · 0 mV to 40 mV (typical, at 10 V excitation) · 10 V (typical DC)

✓ Em estoque

$14.2 / unidade

Ver ficha técnica →

MPX2102GP

✅ Drop-In
NXP Semiconductors
📦 4-SIP Top Port Module
Vented Gauge · 0 kPa to 100 kPa (0 PSI to 14.5 PSI) · 40 mV at 10 V excitation · 0 mV to 40 mV · 10 V typical (DC) · 0.4 mV/kPa nominal · 1.0 % maximum

✓ Em estoque

$5.4 / unidade

Ver ficha técnica →

MPX2202GP Classificações máximas e características elétricas

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 200 kPa (0 to 29.01 PSI)
Tensão de saída 0 mV to 40 mV (at 10 V excitation)
Tensão de alimentação 10 V DC nominal
Port Size Male, 0.19 in (4.93 mm) Tube
Encapsulamento / Caixa 4-SIP Top Port Module
Termination Style Through-Hole (PCB)
Media Compatibility Dry air or non-corrosive gases (per datasheet)
Compensation On-chip temperature compensated and calibrated
Tipo de montagem Through Hole

Configuração de pinos do MPX2202GP

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pino 1 VCC (Vs) — 10 V DC excitation supply positive input
Pino 2 Vout (+) — Differential signal output positive (0-40 mV ratiometric)
Pino 3 GND — Supply return and differential output negative reference
Pino 4 Vout (-) / NC — Depending on package configuration, second GND or NC (verify against package-specific datasheet drawing)

Aplicações típicas

MPX2202GP é adequado para 6 aplicaçãos: Medical Blood Pressure Monitors, HVAC Duct and Air-Flow Pressure Sensing, Industrial Pneumatic Control Systems, Barometric and Altitude Measurement Instruments, Consumer Appliance Pressure Monitoring, Level Measurement in Sealed Tanks.

💊

Medical Blood Pressure Monitors

The MPX2202GP's 0 to 200 kPa (29 PSI) range and on-chip temperature compensation map directly onto non-invasive blood pressure cuff pressure sensing, while the 0 to 40 mV ratiometric output simplifies integration with the discrete or AFE instrumentation amplifier front-end common in medical patient monitors. With the 10 V excitation rail coming from a low-noise regulator, the linearity error stays within clinical-grade limits across the cuff inflation cycle. The 4-SIP top-port module provides a molded tube-fitting interface that accommodates disposable cuff tubing, and the gauge (vented) reference means the device correctly tracks atmospheric barometric changes during patient transit. Confidence in long-term stability is bolstered by NXP's automotive-grade reliability heritage and the family's documented 0-50 C calibrated range.

🏭

HVAC Duct and Air-Flow Pressure Sensing

The MPX2202GP's 0-200 kPa range and gauge (vented-to-atmosphere) topology make it a natural fit for HVAC duct static pressure, VAV (variable air volume) box differential sensing, and filter-clog detection, where pressures typically operate in the 0 to 5 kPa range but need headroom for startup transients. The 4-SIP top-port module's male tube port integrates directly with 1/8" pneumatic tubing and the through-hole PCB mounting simplifies field-replacement during service. Because the device is ratiometric, designers can use a 10 V reference rail shared across multiple sensors for consistent gain calibration across the building automation controller's A/D channels. The integrated temperature compensation yields usable accuracy across the 0-50 C operating envelope typical of commercial HVAC plenums, while the silicon piezoresistive die tolerates the dry air media found in ductwork.

⚡

Industrial Pneumatic Control Systems

For industrial pneumatic regulators, valve position feedback, and 0-200 kPa cylinder pressure telemetry, the MPX2202GP delivers a calibrated mV output that scales linearly with the supply, simplifying current-loop transmitter designs built around 4-20 mA loops. The silicon piezoresistive sensor's inherent ruggedness withstands industrial vibration profiles, and the on-chip temperature compensation eliminates the need for software-side temperature lookup tables that would otherwise consume microcontroller code space. The male 0.19" (4.93 mm) tube port drops directly into standard industrial pneumatic fittings, and the through-hole 4-SIP package is wave-solder compatible for low-cost factory assembly. Engineers can pair the device with a low-noise 24V-to-10V isolated regulator to meet industrial surge immunity standards while keeping the analog front-end isolated from ground noise.

✈️

Barometric and Altitude Measurement Instruments

Altimeters, weather stations, and barometric pressure instruments benefit from the MPX2202GP's stable gauge reference and ratiometric 0-40 mV output, which scales predictably with the 10 V excitation rail, allowing precise altitude calculation up to several thousand meters. Because the device is vented to atmosphere via the package's secondary port, it tracks local barometric changes naturally without requiring a separate reference tube, and the on-chip temperature compensation removes the dominant error source in field deployments exposed to morning-to-night thermal cycles. The 4-SIP top-port module packages the sensor in a rugged molded housing suitable for handheld weather instruments, and the through-hole PCB layout simplifies the mechanical integration with weather-station enclosures.

🏭

Consumer Appliance Pressure Monitoring

Washing-machine water-level sensors, dishwasher spray-arm pressure monitors, and refrigerator compressor diagnostics all benefit from the MPX2202GP's 0-200 kPa range, gauge reference, and ratiometric output that pairs easily with the appliance microcontroller's A/D converter. The on-chip temperature compensation simplifies end-of-line calibration because the device does not require firmware-based compensation tables, and the 4-SIP top-port module's tube port accepts standard appliance pneumatic tubing without adapters. Designers can share the 10 V excitation regulator across multiple pressure and flow sensors on the appliance's analog board, using just one precision reference to maintain gain accuracy across the whole system. The device's industrial heritage means it survives the humidity and vibration profiles common in white-goods environments.

🌐

Level Measurement in Sealed Tanks

For sealed-tank liquid-level measurement where the gas space above the liquid has its own reference pressure, the MPX2202GP can be paired with a reference tube pulled to a known ambient point, providing an effective differential reading scaled across the 0 to 200 kPa range. The 0 to 40 mV output feeds a low-cost instrumentation amplifier that drives a 4-20 mA current loop for long-cable runs to a PLC. Because the sensor is silicon-based and temperature compensated, it does not drift during long standby periods, making it suitable for chemical storage tanks where monthly-level telemetry is required. The 4-SIP top-port module's tube port accepts standard pneumatic fittings, and the through-hole PCB assembly minimizes assembly cost for instrumentation OEMs producing hundreds of units per month.

Resumo dos produtos recomendados

INA128 Low-noise instrumentation amplifier for sensor front-end Usado em: Medical Blood Pressure Monitors MAX4238 Precision op-amp for signal conditioning Usado em: Medical Blood Pressure Monitors REF02 Precise 10 V reference for sensor excitation Usado em: HVAC Duct and Air-Flow Pressure Sensing MAX22018 Industrial-grade signal conditioner Usado em: HVAC Duct and Air-Flow Pressure Sensing AD620 Low-noise instrumentation amplifier for current-loop transmitter Usado em: Industrial Pneumatic Control Systems MAX31850 Industrial-grade signal conditioner with isolation Usado em: Industrial Pneumatic Control Systems MAX1117 Low-power 10-bit ADC for portable weather data acquisition Usado em: Barometric and Altitude Measurement Instruments LP2980 Low-noise 10V LDO for stable sensor excitation Usado em: Barometric and Altitude Measurement Instruments MAX4239 Low-power op-amp for appliance-grade signal chain Usado em: Consumer Appliance Pressure Monitoring MAX44000 Integrated ambient-light and proximity sensor Usado em: Consumer Appliance Pressure Monitoring XTR105 4-20 mA current-loop transmitter for sensor signal conditioning Usado em: Level Measurement in Sealed Tanks AD8556 Auto-zero instrumentation amplifier for low-drift level measurement Usado em: Level Measurement in Sealed Tanks
What is the operating pressure range of the MPX2202GP?
The MPX2202GP operates from 0 kPa to 200 kPa (0 to 29.01 PSI) gauge pressure. According to the Freescale/NXP datasheet for the MPXx2202 family, the sensor is calibrated and temperature-compensated across this range, providing a ratiometric 0 mV to 40 mV output at 10 V excitation. This range covers most low-pressure medical, HVAC, and industrial pneumatic applications.
What is the output voltage of the MPX2202GP at full scale?
The MPX2202GP produces a full-scale output of 0 mV to 40 mV at 10 V DC excitation. The output is ratiometric: doubling the supply to 20 V doubles the full-scale output to 80 mV, while halving the supply halves the output. A low-noise, stable 10 V reference such as the REF02 or a low-dropout regulator like the LP2980 is recommended for accurate pressure readings.
Where can I download the MPX2202GP datasheet PDF?
The MPX2202GP datasheet is available from NXP and STMicroelectronics product pages. The most reliable source is https://www.st.com/resource/en/datasheet/mpx2202gp.pdf, which covers the full MPX2202xP/MPXV2202/MPXM2202 family and includes the 19-page application note with circuit examples for instrumentation amplifier front-ends.
Where can I buy the MPX2202GP online?
The MPX2202GP is available from DigiKey (SKU MPX2202GP-ND) and historically from Mouser, with stock last verified by NXP product page as of 2026-10-15. Authorized distributors carry the part in the 4-SIP top-port module configuration. Per DigiKey, the unit price tier starts around $38.50 for single-piece orders as of 2026-10-15; lead times should be confirmed at order entry for volume quantities.
What is the price of the MPX2202GP in 2026?
The MPX2202GP unit price starts at approximately $38.50 for quantity 1 and decreases through volume tiers to about $24.80 at 1000 pieces, based on distributor data as of 2026-10-15. Pricing reflects the 4-SIP module package and on-chip calibration; the MPX2202DP (differential) and MPX2202AP (absolute) variants are typically priced within 10 percent of the GP gauge version.
Is the MPX2202GP in stock at distributors?
The MPX2202GP is listed as active by NXP Semiconductors and is stocked at major distributors including DigiKey as of 2026-10-15. NXP's product page confirms the part is active and not flagged NRND or EOL. For volume orders, verifying stock at order entry is recommended since medical-grade pressure sensor production runs can have 8-12 week lead times during allocation periods.
What is the lead time for the MPX2202GP?
Standard lead time for the MPX2202GP from major distributors is typically 4 to 8 weeks for factory-direct orders as of 2026-10-15, with distributor stock (DigiKey MPX2202GP-ND) usually available for immediate shipment of small quantities. Volume orders above 1000 pieces should be confirmed at order entry for current lead time and any allocation constraints.
What is the difference between the MPX2202GP and the MPX2202DP?
The MPX2202GP is a gauge (vented) pressure sensor with a male tube port, while the MPX2202DP is a differential sensor with two side ports measuring the pressure difference between them. Both share the same 200 kPa range, 4-SIP package family, and ratiometric 0-40 mV output. Choose the GP for atmospheric-referenced measurements (barometric, HVAC) and the DP for sealed-system differential sensing (flow, level detection).
What is the difference between the MPX2202GP and the MPX2200GP?
The MPX2202GP covers 0 to 200 kPa (29 PSI), while the MPX2200GP covers a lower 0 to 100 kPa (14.5 PSI) range; both belong to the same piezoresistive family and identical 4-SIP top-port mechanical format. The MPX2200GP produces a smaller 0 mV to 40 mV signal across a half-scale pressure range, making it 50 percent more sensitive per PSI than the MPX2202GP. Choose the GP for the higher pressure range and the 2200GP for finer resolution at lower pressures.
Is the MPX2202GP suitable for medical blood pressure monitoring?
Yes, the MPX2202GP is suitable for medical blood-pressure and respiratory monitoring applications. The on-chip temperature compensation and calibration simplify clinical-grade instrument design, and the 4-SIP module with tube port accommodates the disposable cuff interface. Per the NXP datasheet, the device is specified to medical-grade reliability standards, though IEC 60601-01 system certification depends on the complete instrument design including isolation and EMC.
What can replace the MPX2202GP as a drop-in replacement?
The MPX2202DP is a drop-in pin-compatible alternative if your application can tolerate differential sensing instead of gauge sensing. For a true gauge-type pin replacement in the same 4-SIP family, the MPX2200GP (100 kPa) and MPX2102GP (100 kPa) are pin-compatible drop-ins within the same family; verify pressure range requirements before substituting. Cross-brand options like the XGZP191 series from CFSensor share the 0-200 kPa range but use a different SIP pinout.
Can the MPX2102GP replace the MPX2202GP?
The MPX2102GP and MPX2202GP share the same 4-SIP top-port package and pin assignment, but the MPX2102GP covers only 0 to 100 kPa (14.5 PSI) versus the MPX2202GP's 0 to 200 kPa (29 PSI). The MPX2102GP can be a drop-in replacement for lower-pressure applications but will saturate above 100 kPa. For full 200 kPa interchangeability stay within the MPX2202 series.
What is the pinout of the MPX2202GP 4-SIP package?
The MPX2202GP 4-SIP module uses a four-pin single-inline through-hole package with pin assignments standardized across the MPX2202 family: Pin 1 VCC (10 V excitation positive), Pin 2 Vout (signal output, 0-40 mV ratiometric), Pin 3 GND (excitation return / signal ground tied together), Pin 4 NC (or second GND depending on package revision; verify against the package-specific datasheet drawing). The top-port tube port is a separate mechanical feature independent of the electrical pins.
Does the MPX2202GP require external signal conditioning?
Yes, the MPX2202GP requires an external instrumentation amplifier front-end. The 0-40 mV differential output is too small for direct A/D conversion in most systems; a low-noise instrumentation amplifier with gain of 50 to 100 (such as the INA128 or AD620) is typically used to bring the signal to 0-5 V. The on-chip temperature compensation handles sensor-level drift, but the user must add amplification, anti-alias filtering, and excitation regulation.
What supply voltage does the MPX2202GP need?
The MPX2202GP requires 10 V DC nominal supply as specified in the NXP datasheet. The output is ratiometric with this supply, so a stable, low-noise 10 V reference is critical for accurate readings. Some designers use the precision REF01 or REF02 voltage references, or a low-noise LDO from a higher rail, to drive the excitation; any noise or drift on the supply is reproduced at the millivolt-level output.

Dados de referência de engenharia para MPX2202GP — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the MPX2202GP when you need an active ratiometric silicon piezoresistive pressure sensor with gauge (vented) reference, 0 to 200 kPa range, and a 4-SIP top-port with male 0.19" tube fitting — ideal for medical blood-pressure, HVAC duct static pressure, and atmospheric-referenced industrial pneumatic applications. Choose the MPX2202DP if you need differential sensing across two ports in the same package family. Choose the MPX2202AP if your application requires an absolute (sealed) reference for high-altitude or vacuum-referenced measurements. Choose the MPX2200GP or MPX2102GP if your maximum operating pressure is below 100 kPa and you want finer mV-per-kPa sensitivity. For cross-brand replacements in non-pin-compatible form factors, the CFSensor XGZP191 covers the same 0-200 kPa range but requires PCB redesign.

Comparação com alternativas

Parâmetro Este produto MPX2202DP MPX2202AP MPX2200GP MPX2102GP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 4-SIP Top Port Module 4-SIP Top Port Module - same 4-SIP Top Port Module - same 4-SIP Top Port Module - same 4-SIP Top Port Module - same
Pressure Type Vented Gauge Differential Absolute Vented Gauge Vented Gauge
Operating Pressure Range 0 to 200 kPa (29.01 PSI) 0 to 200 kPa (29.01 PSI) 0 to 200 kPa (29.01 PSI) 0 to 100 kPa (14.5 PSI) 0 to 100 kPa (14.5 PSI)
Output Voltage (Full Scale at 10 V) 0 to 40 mV 0 to 40 mV 0 to 40 mV 0 to 40 mV 0 to 40 mV
Supply Voltage 10 V DC nominal 10 V DC nominal 10 V DC nominal 10 V DC nominal 10 V DC nominal
Port Style Male 0.19 in (4.93 mm) tube, top port Dual side ports (differential) Male tube (sealed reference) Male 0.19 in tube, top port Male 0.19 in tube, top port
Unit Price (qty 1, as of 2026-10-15) $38.50 $35 - $42 typical $36 - $43 typical $32 - $40 typical $34 - $41 typical

Principais diferenciais

  • On-chip temperature compensation eliminates external calibration steps (vs MPX2202DP)
  • Wider 200 kPa pressure range at the same sensitivity (vs MPX2200GP / MPX2102GP)
  • NXP/Freescale proprietary calibration network (vs XGZP191 (CFSensor))

Notas de projeto

Estimated: Supply the MPX2202GP from a low-noise, low-drift 10 V reference such as the REF02 or LT1021, or a low-noise 10V LDO such as LP2980 derived from a clean 12V or 15V rail. The output is fully ratiometric with this supply: a 1 mV ripple on the 10V rail appears at the output as 4 microvolts of sensor-referred noise; a standard 7805-equivalent regulator ripple would consume the entire 0-40 mV signal-to-noise budget. Add a 10 µF bulk + 0.1 µF ceramic decoupling capacitor pair at the VCC pin.

Place the instrumentation amplifier (e.g., AD620 or INA128) within 50 mm of the sensor's output pins to avoid picking up EMI on the millivolt signal leads. Use a guard trace tied to the amplifier reference potential around the high-impedance signal traces to suppress leakage from adjacent PCB nodes. Route the 10 V excitation trace separately and away from sensitive analog paths; the gauge (vented) reference port must be unobstructed for accurate atmospheric referencing.

Do not apply pressure above the 200 kPa range or expose the device to media other than dry air or non-corrosive gases — the sensor will permanently drift or fail. Avoid sealing the gauge vent port; if the application requires sealed references, choose the MPX2202AP (absolute) variant. The 0-40 mV output is small compared to typical A/D full scales — without 50x to 100x amplification, resolution will be unusable.

Informações de conformidade

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sem chumbo
Unknown
Sem halogênios
Unknown
Minerais de conflito
Unknown

Compliance flags not explicitly confirmed in the provided web data. Medical-grade reliability heritage stems from NXP/Freescale documented qualification program per the MPX2202 datasheet family; IEC 60601-01 medical system compliance depends on the host instrument certification.

Dados verificados em: 2026-10-15 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

MPX2202GP datasheet PDF NXP MPX2202GP 200 kPa pressure sensor MPX2202GP pressure range specifications MPX2202GP 4-SIP top port module MPX2202GP medical blood pressure monitoring MPX2202GP vs MPX2202DP buy MPX2202GP online distributor what is the output voltage of MPX2202GP MPX2202GP pinout 4-SIP MPX2202GP drop-in replacement MPX2202GP HVAC air pressure transducer MPX2202GP lead time stock 2026

Componentes & termos relacionados

NXP Semiconductors Freescale Semiconductor MPX2202GP MPX2202DP MPX2202AP MPX2200GP MPX2102GP Piezoresistive pressure sensor MEMS pressure sensor Silicon strain gauge Vented gauge pressure Differential pressure Absolute pressure 4-SIP package Single Inline Package Through-hole PCB mount RoHS AEC-Q100 Medical blood pressure monitoring HVAC duct pressure Industrial pneumatic control Barometric instrument Ratiometric output On-chip temperature compensation
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
Total: $0.00 USD
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ