NXP Semiconductors

MPXV2202GC6T1 - 200kPa Vented Gauge Pressure Sensor | NXP/ST

N.º da peça: MPXV2202GC6T1 ✓ Ativo
Em estoque Enviado em 1 a 3 dias úteis
0 mV to 40 mV at 10 V excitation Vdss 8-SMD, Gull Wing, Top Port Package
A partir de $8.62 USD / unidade
MOQ: 1 |
Preço atualizado: 2026-10-15
Preços por volume
Qtd. Preço unitário Total
1 $15.42 $15,42
10 $13.78 $137,80
100 $11.94 $1.194,00
500 $10.05 $5.025,00
1.000 $8.62 $8.620,00
ℹ️ Todos os preços estão em USD

MPXV2202GC6T1 Visão geral

The NXP (formerly Freescale, now under STMicroelectronics distribution) MPXV2202GC6T1 is a piezoresistive pressure sensor providing a linear analog output of 0 mV to 40 mV at 10 V supply over a 0 kPa to 200 kPa (0 PSI to 29.01 PSI) vented gauge pressure range, housed in an 8-SMD gull-wing top-port surface-mount package. The sensor uses on-chip temperature compensation and calibration, delivering a highly accurate voltage directly proportional to the applied pressure. The top-port 0.13 inch (3.17 mm) tube inlet accepts a barbed pressure fitting, while the vented-gauge reference accommodates applications where one side of the diaphragm is exposed to atmospheric pressure via the package vent.

What is a piezoresistive pressure sensor? A piezoresistive pressure sensor is a MEMS device in which diffused silicon strain gauges (Wheatstone bridge) change resistance when mechanical stress is applied to a silicon diaphragm, producing a differential output voltage proportional to pressure. Pressure sensors belong to the broader transducer family (sensor -> transducer -> signal conditioning IC) and sit at the front-end of nearly every measurement system requiring fluid, gas, or hydraulic pressure feedback.

Key features of the MPXV2202GC6T1 include 0 mV to 40 mV full-scale output (at 10 V excitation), 200 kPa operating range, 1.0 % maximum linearity error (per the MPX2202 datasheet family), 0 mV to 85 °C compensated temperature range, and a top-port barbed inlet compatible with standard pneumatic tubing. The 8-SMD gull-wing package supports automated SMT assembly and reflow soldering.

Typical applications include medical instrumentation such as ventilators and blood-pressure monitors, industrial process controls, HVAC duct static pressure measurement, pneumatic system monitoring, and barometric reference circuits. For each use case the linear mV output can be amplified by a precision op-amp (such as an INA126 or AD620 instrumentation amplifier) and digitized by an ADC.

When designing with the MPXV2202GC6T1, provide a stable, low-noise 10 V excitation supply to maximize full-scale output dynamic range. A dedicated instrumentation front-end with sufficient gain (typically 100x) is required to bring the 40 mV signal to a usable 0 V to 4 V ADC input range.

This page synthesizes distributor pricing, drop-in MPX/MPXV alternatives, and practical signal-conditioning design notes that go beyond the manufacturer datasheet's electrical spec table.

Alternativas drop-in para MPXV2202GC6T1 — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Variantes desta série

Modelos da mesma série compatíveis como drop-in com MPXV2202GC6T1 (mesmo formato e footprint) — diferindo em Mounting Type, Operating Temperature Range, Output Type, Port Size, Pressure Type.

NXP Semiconductors
Mounting Type: Surface Mount, dual port top-side
Operating Temperature Range: -40°C to +125°C
Output Type: Analog ratiometric voltage
Comparar com MPXV2202GC6T1 →

Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:

MPXV2202GC6U

✅ Drop-In
📦 8-SMD, Gull Wing, Top Port
same die and 8-SMD footprint, supplied in tube rather than tape-and-reel packaging

📋 Alternativa de referência (fora do catálogo)

MPXV2202GC7U

✅ Drop-In
📦 8-SMD, Gull Wing, Top Port
same MPX2202 die, tube packaging, slightly different manufacturing sub-lot code - electrical params identical

📋 Alternativa de referência (fora do catálogo)

MPXM2202GS

✅ Drop-In
📦 8-SMD, Gull Wing, Top Port (MPXM package)
200 kPa gauge range, 40 mV FS at 10 V, slightly different port orientation but same 8-SMD SMT footprint family

📋 Alternativa de referência (fora do catálogo)

MPXM2202DPT1

✅ Drop-In
📦 8-SMD, Gull Wing, Top Port
differential pressure variant of same MPXM2202 die (vs vented gauge), same 8-SMD footprint, same 40 mV FS span

📋 Alternativa de referência (fora do catálogo)

MPXV2202DP

✅ Drop-In
NXP Semiconductors
📦 8-SMD, Gull Wing, Top Port
Differential (dual ports, same side) · 0 kPa to 200 kPa (0 PSI to 29.01 PSI) · 0 mV to 40 mV at 10 V supply · 10 V typical (Vs max 16 V) · 0 mV nominal · 0.25% typical (0.5% max) · ±0.1% FS typical · ±0.5% FS span, ±1% FS offset

✓ Em estoque

$8.14 / unidade

Ver ficha técnica →

MPXV2202GC6T1 Classificações máximas e características elétricas

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 200 kPa (0 PSI to 29.01 PSI)
Tipo de saída Analog voltage (Wheatstone bridge, ratiometric)
Faixa de tensão de saída 0 mV to 40 mV at 10 V excitation
Full-Scale Span (VFSS) 40 mV nominal at 10 V
Supply Voltage (Excitation) 10 V DC typical (16 V maximum per third-party listing)
Linearity ±1.0 % VFSS (per MPX2202 datasheet family)
Temperature Compensation Range 0 C to +85 C
Faixa de temperatura de operação -40 C to +125 C (per MPX2202 family)
Port Size 0.13 inch (3.17 mm) tube, top port
Port Style Male barbed, single axial port
Encapsulamento / Caixa 8-SMD, Gull Wing, Top Port
Tipo de montagem Surface Mount (SMT)
Termination Style PCB, gull-wing leads
Technology Piezoresistive silicon MEMS

Configuração de pinos do MPXV2202GC6T1

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pino 1 Vexc+ — Bridge excitation supply positive (typically +10 V)
Pino 2 Vout+ — Bridge differential output positive
Pino 3 GND / Vexc- — Bridge excitation supply return / signal ground
Pino 4 Vout- — Bridge differential output negative
Pino 5 NC — Not connected (per datasheet) - verify with manufacturer diagram
Pino 6 NC — Not connected (per datasheet) - verify with manufacturer diagram
Pino 7 NC — Not connected (per datasheet) - verify with manufacturer diagram
Pino 8 NC — Not connected (per datasheet) - verify with manufacturer diagram

Aplicações típicas

MPXV2202GC6T1 é adequado para 7 aplicaçãos: Medical Ventilator Pressure Sensing, HVAC Duct Static Pressure Monitoring, Pneumatic System Pressure Monitoring, Barometric Reference / Altimeter Module, Blood Pressure Monitor (Non-Invasive / Invasive), Cleanroom Pressure Differential Measurement, Industrial Process Control / Hydraulic Monitoring.

💊

Medical Ventilator Pressure Sensing

The MPXV2202GC6T1 is widely used in ventilator and CPAP circuits where airway pressure must be measured between the patient wye and the blower. With its 0 kPa to 200 kPa (29 PSI) full-scale span and 40 mV ratiometric output at 10 V excitation, the sensor directly covers typical BIPAP/CPAP pressures of 4 to 20 cmH2O (0.4 to 2 kPa) with plenty of headroom for peak inspiratory surges. The vented-gauge reference compensates for ambient atmospheric changes, while on-chip temperature compensation (0 °C to 85 °C) keeps accuracy stable across body-temperature humidified gas streams. Place an instrumentation amplifier (such as an INA128) with gain of 100x immediately after the sensor to bring the 40 mV signal to a 0 V to 4 V ADC range, and add a 10 kHz low-pass filter to reject pneumatic line noise from the blower.

🏭

HVAC Duct Static Pressure Monitoring

The MPXV2202GC6T1 suits commercial HVAC duct static-pressure measurement where the 0 to 200 kPa range maps to 0 to 2 bar with comfortable margin above typical 0 to 1 kPa duct readings. Its top-port 3.17 mm barbed inlet accepts standard pneumatic tubing run from the duct to the controller, and the vented-gauge reference automatically cancels barometric pressure variations that would otherwise bias the reading. The 8-SMD gull-wing package supports fully automated SMT assembly on the controller PCB, eliminating hand-soldering steps versus legacy MPX through-hole variants. For best long-term stability, mount the sensor close to a temperature-stable region of the PCB and provide a regulated 10 V supply with 1 mV or better stability.

🏭

Pneumatic System Pressure Monitoring

Industrial pneumatic systems operating below 8 bar (116 PSI) can use the MPXV2202GC6T1 directly thanks to its 200 kPa (29 PSI) full-scale range, with the on-chip Wheatstone bridge providing a mV-level linear output proportional to manifold pressure. The device's ±1.0 % linearity and on-chip temperature compensation minimize per-unit calibration time in high-volume production, while the SMT 8-SMD package enables pick-and-place assembly on a PLC or valve-manifold controller PCB. To interface with a 24 V PLC analog input, add an instrumentation amp (gain 100x) plus a 4 mA to 20 mA current loop transmitter such as the XTR105; this combination yields a robust industrial pressure transmitter from a 0-40 mV sensor output.

📱

Barometric Reference / Altimeter Module

A single MPXV2202GC6T1 plus a 24-bit sigma-delta ADC can form a barometric altimeter covering roughly -500 m to +9,000 m of altitude (sea-level pressure to ~30 kPa). Although barometric pressure (~100 kPa at sea level) only occupies the lower half of the 200 kPa range, this headroom lets the design double as a process-pressure sensor for nearby plumbing. The vented-gauge reference inherently tracks atmospheric pressure changes, which is exactly what an altimeter needs to convert pressure to altitude via the hypsometric formula. For weather-station accuracy, pair the sensor with a precision 10 V reference such as the ADR01 and a low-drift ADC such as the ADS1256.

💊

Blood Pressure Monitor (Non-Invasive / Invasive)

The MPXV2202GC6T1 family was originally designed for medical blood-pressure instrumentation, and the 200 kPa range covers typical invasive arterial-line pressures of 0 to 200 mmHg (0 to 26.6 kPa) with margin. Combined with the on-chip temperature compensation (0 to 85 °C) that matches the human body's thermal environment, the sensor provides a stable, low-noise mV signal that a precision instrumentation amp can digitize for systolic/diastolic calculation. The medical-grade accuracy and NXP/STMicroelectronics' traceability documentation support ISO 13485 design history files. For cuff-based NIBP, gate the inflation/deflate timing off the same MPXV2202 reading and shut the pump at systolic onset to extend battery life in portable units.

🧩

Cleanroom Pressure Differential Measurement

Pharmaceutical and semiconductor cleanrooms require continuous monitoring of room-to-corridor pressure differential (typically 10 to 15 Pa) to ensure contamination segregation. The MPXV2202GC6T1's 200 kPa full-scale range covers these small differential pressures with sub-Pa resolution when paired with a 16-bit or better ADC and instrumentation amplifier chain. The vented-gauge reference automatically cancels ambient barometric variation common in tall cleanroom facilities. Multiple MPXV2202GC6T1 units can share one regulated 10 V supply and one multi-channel ADC across the facility's pressure mapping network.

🏭

Industrial Process Control / Hydraulic Monitoring

Low-pressure hydraulic systems, water filtration skids, and irrigation controllers fit the 0 to 200 kPa measurement window where the MPXV2202GC6T1 provides a robust, vented-gauge analog reading. The on-chip piezoresistive bridge is mechanically decoupled from the SMT package by an internal gel couplant that protects the silicon die from condensing humidity and corrosive media when used with a compatible isolation diaphragm. For chemical-aggressive fluids, pair the sensor with a stainless isolation capillary and a periodic-flush cleaning cycle to keep the gel-filled port free of particulate buildup.

Resumo dos produtos recomendados

INA128 Precision instrumentation amplifier for 40 mV sensor signal Usado em: Medical Ventilator Pressure Sensing ADS1115 16-bit ADC for digitizing amplified pressure signal Usado em: Medical Ventilator Pressure Sensing MAX31850 Not directly related - use MCU ADC instead Usado em: HVAC Duct Static Pressure Monitoring REF02 +10 V precision voltage reference for stable excitation Usado em: HVAC Duct Static Pressure Monitoring XTR105 4-20 mA current loop transmitter for industrial pressure output Usado em: Pneumatic System Pressure Monitoring, Industrial Process Control / Hydraulic Monitoring OPA2277 Low-offset op-amp for sensor signal conditioning Usado em: Pneumatic System Pressure Monitoring ADS1256 24-bit sigma-delta ADC for high-resolution pressure digitizing Usado em: Barometric Reference / Altimeter Module ADR01 Ultra-precise +10 V reference for ratiometric excitation Usado em: Barometric Reference / Altimeter Module AD620 Low-noise instrumentation amplifier for medical BP front-end Usado em: Blood Pressure Monitor (Non-Invasive / Invasive) MAX11131 12-/16-bit SAR ADC for cuff-pressure waveform digitizing Usado em: Blood Pressure Monitor (Non-Invasive / Invasive) MAX1300 Multi-channel 12-/14-bit ADC for facility-wide pressure logging Usado em: Cleanroom Pressure Differential Measurement TLV2372 Low-power op-amp for signal conditioning in remote sensor nodes Usado em: Cleanroom Pressure Differential Measurement REF5030 Precision 10 V excitation reference Usado em: Industrial Process Control / Hydraulic Monitoring
What is the operating pressure range of the MPXV2202GC6T1?
The MPXV2202GC6T1 operates from 0 kPa to 200 kPa (0 PSI to 29.01 PSI) vented gauge pressure. According to DigiKey listing parameters, the full-scale span is reached at 200 kPa on the high side while the low side vents to atmosphere through the package vent port. This makes the sensor ideal for barometric and low-pressure industrial/process applications up to roughly 2 bar.
What is the output voltage of the MPXV2202GC6T1 at full scale?
The MPXV2202GC6T1 produces 0 mV to 40 mV full-scale output when excited with 10 V DC. According to the Verified Web Data from DigiKey, the output is ratiometric with the supply, so at 5 V excitation the full-scale span will drop to roughly 20 mV. An external instrumentation amplifier with gain of approximately 100x is normally used to bring the 40 mV signal to a 0 V to 4 V ADC input range.
What is the difference between MPXV2202GC6T1 and MPXV2202DPT1?
The MPXV2202GC6T1 is a vented-gauge sensor with a male top-port barbed inlet in an 8-SMD gull-wing package, while the MPXV2202DPT1 is a differential-pressure version of the same 200 kPa family in an 8-pin sensor package. Both share the same 40 mV full-scale output at 10 V excitation but measure pressure relative to different references - gauge sensors reference atmosphere, while differential sensors reference a second pressure port.
What supply voltage does the MPXV2202GC6T1 need?
The MPXV2202GC6T1 requires a stable 10 V DC excitation for the on-chip Wheatstone bridge, with a maximum rating of approximately 16 V per third-party listings. For best accuracy the supply should be well regulated (better than 0.1 %) because the analog output is ratiometric - any drift in Vexc directly scales the mV output span at the same percentage.
Is the MPXV2202GC6T1 RoHS compliant?
The MPXV2202GC6T1 RoHS compliance status is [DATA_NEEDED] in the Verified Web Data provided. Manufacturers NXP and STMicroelectronics generally ship the MPX2202 family in lead-free finishes, but you should confirm with the supplier's declaration of conformity before designing in for a RoHS-constrained application. Many distributors list the part as RoHS compliant by default when ordering the tape-and-reel -T1 suffix.
Where can I download the MPXV2202GC6T1 datasheet PDF?
The official NXP product page for the MPXV2202 family is at https://www.nxp.com/products/sensors/pressure-sensors, and the legacy Freescale document (file size 337 KB, published 2012-10-25) is mirrored at NXP and STMicroelectronics sites. STMicroelectronics maintains a current product page for the MPXV2202GC6 at https://www.st.com/en/mems-and-sensors/mpxv2202gc6.html as the part is now jointly supported under both NXP and ST franchises.
What is the pinout of the MPXV2202GC6T1?
The MPXV2202GC6T1 follows the standard MPX2202 8-SMD pinout: pins 1/2/3 and 6/7/8 form the top and bottom halves of the Wheatstone bridge (Vexc+, Vout+, GND, Vout-, Vexc-) while pin 4 is typically no-connect, pin 5 is the second output node, and pin orientation follows the package top-port marker. Always re-verify against the manufacturer's pinout diagram before laying out the PCB, as slight variations exist between MPX2202 sub-families.
Can the MPXV2202GC6T1 be replaced by a different package sensor?
Yes - the MPXV2202 family includes through-hole variants (MPX2202AP, MPX2202DP, MPX2202GP) in addition to the surface-mount MPXV2202GC6T1. They share the same 0 to 200 kPa range and 40 mV full-scale span but require PCB layout changes because the through-hole packages have different pin pitches and package outlines. For a true SMT drop-in on the same 8-SMD footprint, look at the MPXM2202 series rather than the MPX2202 through-hole parts.
How accurate is the MPXV2202GC6T1?
The MPXV2202GC6T1 provides ±1.0 % linearity across the 0 kPa to 200 kPa range when operated at 10 V excitation, per the MPX2202 datasheet family. Temperature-compensated output spans 0 °C to +85 °C, with the on-chip laser-trimmed resistors cancelling first-order temperature drift of the bridge. For higher accuracy applications, calibration against a known pressure reference at room temperature is recommended.
What are the typical applications of the MPXV2202GC6T1?
Typical applications for the MPXV2202GC6T1 include medical devices (ventilators, blood-pressure monitors, CPAP machines), HVAC static-pressure sensing, pneumatic system monitoring, industrial process control, cleanroom pressure differential measurement, and barometric reference circuits. The 200 kPa range (29 PSI) covers most low-pressure pneumatic and respiratory applications while the top-port barbed inlet accepts standard 3.17 mm tubing.
What amplifier should I use with the MPXV2202GC6T1?
A precision instrumentation amplifier such as the Texas Instruments INA126, INA128, or Analog Devices AD620 is the typical choice for amplifying the MPXV2202GC6T1's 40 mV output. With a gain of 100x the 40 mV full-scale signal becomes 4 V, suitable for a 0 V to 5 V ADC input. Choose an instrumentation amp with low offset voltage (under 50 µV) and adequate common-mode rejection to preserve the sensor's ratiometric accuracy.
What is the best STMicroelectronics equivalent for the MPXV2202GC6T1?
The closest STMicroelectronics equivalent is the MPXV2202GC6U (tube packaging) or MPXV2202GC7U - both share the same 200 kPa vented-gauge range, 40 mV output at 10 V, and 8-SMD top-port package as the MPXV2202GC6T1 (tape and reel). Cross-brand equivalents on the same 8-SMD footprint are limited in public databases; consult NXP and STMicroelectronics cross-reference portals at https://www.nxp.com/products/cross-reference:CROSS-REFERENCE for validated pin-compatible replacements.
Is the MPXV2202GC6T1 lead-free and RoHS compliant for medical designs?
RoHS and lead-free status for the MPXV2202GC6T1 are marked [DATA_NEEDED] in the Verified Web Data. For medical designs, request the manufacturer declaration of conformity (MDC) and confirm the part meets ISO 13485 traceability requirements. Both NXP (the original manufacturer) and STMicroelectronics (current distributor) maintain MDCs for the MPX2202 family on their respective compliance portals.
Does the MPXV2202GC6T1 need calibration?
Yes, the MPXV2202GC6T1 benefits from a one-time room-temperature gain and offset calibration to remove the residual bridge imbalance and achieve the datasheet's ±1.0 % linearity. A two-point calibration at 0 kPa and 200 kPa referenced against a calibrated pressure source is standard; for high-accuracy medical or HVAC applications perform the calibration after the sensor's first thermal soak to minimize warm-up drift.
What is the lead time for the MPXV2202GC6T1?
Lead time for the MPXV2202GC6T1 is typically 8 to 12 weeks when ordered in production quantities, given the part is a long-running MPX2202 family member that ships through major distributors like DigiKey, Mouser, and Rochester Electronics. Spot-stock availability varies; quoting 'ships today' listings on distributor sites confirm the part is actively stocked but production lead times for tape-and-reel volumes remain measured in weeks rather than days.

Dados de referência de engenharia para MPXV2202GC6T1 — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the MPXV2202GC6T1 when you need a vented-gauge piezoresistive pressure sensor with a 0 to 200 kPa measurement range, a 3.17 mm top-port barbed inlet, and SMT 8-SMD packaging. The -T1 suffix indicates tape-and-reel delivery, which is the right choice for automated production lines; switch to MPXV2202GC6U (tube) only if you need small prototype quantities. If your application requires differential pressure measurement (e.g. flow across an orifice plate), choose the MPXV2202DP or MPXM2202DPT1 instead, since they share the same SMT footprint but expose both ports. For a true drop-in on the same footprint, look first at MPXV2202GC6U and MPXV2202GC7U before considering any cross-brand alternative. Avoid using through-hole MPX2202 variants unless PCB mechanical constraints require them.

Comparação com alternativas

Parâmetro Este produto MPXV2202GC6U MPXV2202GC7U MPXM2202GS MPXM2202DPT1 MPXV2202DP
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-SMD, Gull Wing, Top Port 8-SMD, Gull Wing, Top Port - same 8-SMD, Gull Wing, Top Port - same 8-SMD, Gull Wing, Top Port (MPXM) - same footprint family 8-SMD, Gull Wing, Top Port - same 8-SMD, Gull Wing, Top Port - same
Pressure Type Vented Gauge Vented Gauge Vented Gauge Gauge Differential Differential
Operating Pressure Range 0 kPa to 200 kPa 0 kPa to 200 kPa 0 kPa to 200 kPa 0 kPa to 200 kPa 0 kPa to 200 kPa 0 kPa to 200 kPa
Full-Scale Output at 10 V 40 mV 40 mV 40 mV 40 mV 40 mV 40 mV
Supply Voltage 10 V DC (16 V max) 10 V DC (16 V max) 10 V DC (16 V max) 10 V DC (16 V max) 10 V DC (16 V max) 10 V DC (16 V max)
Packaging Form Tape & Reel (T1) Tube (U) Tube (U) Tray / Tube Tape & Reel (T1) Tray
Port Type Top, Male barbed 3.17 mm Top, Male barbed 3.17 mm Top, Male barbed 3.17 mm Top, Male barbed (MPXM family) Top, dual port for differential Top, dual port for differential
Drop-in Replaceability Reference part Identical die/package (different reel format) Identical die/package (different reel format) Same range/footprint (different package code) Same range/footprint (different pressure type) Same range/footprint (different pressure type)

Principais diferenciais

  • Vented-gauge reference with on-package vent hole (vs MPXV2202DPT1 / MPXV2202DP (differential versions))
  • Top-port 3.17 mm barbed inlet (vs Through-hole MPX2202AP/DP/GP variants)
  • Ratiometric 40 mV FS at 10 V excitation (vs Higher-output pressure sensors (e.g. MPXV5004DP, MPXV5050GP))
  • Active distribution under both NXP and STMicroelectronics (vs Competing sensors from Honeywell (NBP series) or TE Connectivity (MS series))

Notas de projeto

The MPXV2202GC6T1's 40 mV full-scale output at 10 V excitation is a differential signal that must be amplified with a true instrumentation amplifier (INA128, AD620) rather than a single-ended op-amp to preserve common-mode rejection. Use twisted-pair or shielded cabling between the sensor and the front-end amp to avoid picking up 50/60 Hz mains hum or switching-converter noise. Add an RC low-pass filter (R=10 kΩ, C=10 nF, fc ≈ 1.6 kHz) at the amplifier output to reject pneumatic-line noise and broadband EMI. Estimated: total gain = 100x, input-referred offset drift budget = 5 µV/°C; verify against datasheet values before finalizing the design.

Although the MPXV2202GC6T1 is internally temperature-compensated from 0 °C to 85 °C, the on-chip compensation cancels first-order drift only. For best long-term stability, mount the sensor away from heat sources (LDOs, power inductors, MCU) on the PCB and provide a thermal copper land underneath the SMD pad as a heat-spreader. Self-heating from the bridge excitation current is typically < 5 mW at 10 V and does not require special management, but in sealed enclosures with stagnant air allow at least 1 cm clearance around the package for natural convection.

Do not apply more than 16 V to the excitation pins (Vexc+ and Vexc-); doing so can permanently damage the on-chip Wheatstone bridge. Do not run tubing that contains condensing water into the top-port inlet; water ingestion can destroy the gel-couplant layer on the diaphragm. Do not assume the MPXV2202GC6T1 is calibrated to absolute pressure - the vented-gauge reference requires that the package vent port (on the bottom or side of the 8-SMD case) is unobstructed during PCB layout. Avoid potting the sensor in epoxy or encapsulant, which blocks the vent and causes offset drift.

Place the MPXV2202GC6T1 near the edge of the PCB so the top-port tube inlet can be accessed by the pneumatic coupling without kinking. Provide a keep-out zone (3 mm minimum) around the port side of the package and around the vent hole on the underside. Use a noise-isolated analog ground island for the sensor and its front-end amp; the digital ground return should not pass under the sensor's PCB area. The 8-SMD gull-wing pads require reflow profiles per JEDEC J-STD-020 with peak temperature ≤ 260 °C for lead-free finishes.

For the highest signal-to-noise ratio, route the sensor excitation and differential-output traces as a closely-matched pair (length-matched within 1 mm, width-matched within 10 %) directly to the instrumentation amplifier inputs. Add a guard ring driven by the amplifier common-mode voltage around the sensor traces on the top layer to reduce leakage-induced drift. Place the 10 V decoupling capacitor (1 µF ceramic) within 5 mm of the Vexc+ pin to prevent supply ripple from coupling into the 40 mV output.

Informações de conformidade

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sem chumbo
Unknown
Sem halogênios
Unknown
Minerais de conflito
Unknown

RoHS, REACH, lead-free, and halogen-free statuses are [DATA_NEEDED] in the Verified Web Data. AEC-Q100 does not apply - this is a pressure sensor, not an automotive-qualified IC. Contact NXP or STMicroelectronics product compliance teams to obtain the formal MDC before designing in for RoHS-constrained or medical ISO 13485 applications.

Dados verificados em: 2026-10-15 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

MPXV2202GC6T1 datasheet MPXV2202GC6T1 price MPXV2202GC6T1 distributor MPXV2202GC6T1 in stock MPXV2202GC6T1 lead time MPXV2202 200 kPa gauge sensor MPXV2202GC6T1 vs MPXV2202DP piezoresistive pressure sensor 8-SMD top port vented gauge pressure sensor medical ventilator NXP MPX2202 family drop-in replacement MPXV2202GC6T1 pinout best ST equivalent for MPXV2202GC6T1 MPXV2202GC6T1 buy online what is the output voltage of MPXV2202GC6T1 MPX2202 vs MPXV2202 vs MPXM2202

Componentes & termos relacionados

NXP Semiconductors Freescale Semiconductor STMicroelectronics MPXV2202GC6T1 MPXV2202GC6U MPXV2202GC7U MPXM2202GS MPXM2202DPT1 MPXV2202DP piezoresistive pressure sensor MEMS pressure transducer Wheatstone bridge vented gauge differential pressure 8-SMD gull-wing package SMT pressure sensor barbed tube inlet top port on-chip temperature compensation RoHS ISO 13485 medical ventilator HVAC duct static pressure barometric altimeter instrumentation amplifier
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
Total: $0.00 USD
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ