OPA4187ID - 4-Channel Zero-Drift Precision Op Amp | TI
N.º da peça: OPA4187ID ✓ AtivoOPA4187ID Visão geral
A zero-drift operational amplifier is a precision amplifier whose internal offset-correction mechanism continually reduces input-offset voltage and its temperature-dependent variation. In the signal-chain hierarchy, the OPA4187 belongs to the operational-amplifier family, specifically the zero-drift precision amplifier class. Unlike general-purpose amplifiers whose offset can move appreciably with temperature, this architecture targets applications requiring accurate DC amplification, sensing, and signal conditioning over extended temperature ranges.
Key characteristics include four amplifiers in one package, a 36 V maximum supply rating, rail-to-rail output capability, low-power operation, and MUX-friendly input design. MUX-friendly inputs are especially useful in multiplexed measurement systems because they help preserve measurement accuracy when several signal sources are switched through a common analog front end. Combining four precision channels in one SOIC can also reduce board area and simplify power planning in multi-channel instruments.
The OPA4187 combines low offset drift with low power, providing a practical balance for precision systems that do not require the size, power, or input capacitance of a large high-voltage amplifier. Its four-channel construction supports repeated front-end channels in bridge, current, voltage, and sensor-conditioning circuits, while the rail-to-rail output helps preserve signal swing when the available supply voltage is constrained.
Typical applications include precision data acquisition, industrial process-control modules, multichannel sensor interfaces, laboratory instrumentation, and low-level signal conditioning. In a four-channel bridge amplifier, the amplifier family provides matched architectural channels while the system relies on external precision resistors and low-noise references. In an active sensor front end, the low drift helps reduce calibration movement as ambient temperature changes.
Designers should pay particular attention to common-mode range, input bias current, gain-bandwidth product, output-current capability, noise, and stability when selecting external feedback networks. These parameters must be checked in the Texas Instruments OPA4187 datasheet for the intended supply voltage and gain. Decoupling capacitors should be placed close to the supply pins, and sensitive measurement boards should minimize thermal gradients across matched input networks.
This product summary combines the manufacturer family information with package, operating-range, and ordering details, then adds practical application guidance and strict same-footprint replacement analysis. It also identifies where an engineer must compare individual electrical limits before approving a replacement or changing the gain, bias, filtering, or grounding configuration of an existing precision analog board.
Alternativas drop-in para OPA4187ID — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Nenhuma alternativa drop-in disponível para este produto.
Solicitar alternativasOPA4187ID Classificações máximas e características elétricas
| Amplifier Type | Zero-drift precision operational amplifier |
| Number of Channels | 4 circuits |
| Technology | Zero-drift CMOS |
| Input Offset Voltage Drift | 0.001 µV/°C |
| Maximum Supply Voltage | 36 V |
| Output Swing | Rail-to-rail |
| Input Multiplexer Compatibility | MUX-friendly |
| Power Consumption | Low power |
| Minimum Operating Temperature | -40°C |
| Maximum Operating Temperature | +125°C |
| Encapsulamento | 14-pin SOIC |
| Package Length | 0.154 inch |
| Package Width | 3.90 mm |
Guia de Configuração de Pinos do OPA4187ID 3.90 mm
Configuração de pinos para OPA4187ID (pacote 3.90 mm). Este componente analógico possui pinos de entrada, saída e alimentação. Consulte o datasheet do fabricante para configurações de offset null, compensação e pino de enable. Ideal para circuitos de condicionamento de sinal e amplificadores.
Nenhum dado detalhado de pinagem disponível para OPA4187ID.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
OPA4187ID é adequado para 6 aplicaçãos: Precision Data Acquisition, Industrial Sensor Conditioning, Laboratory Instrumentation, Battery Monitoring, Process-Control Modules, Medical and Diagnostic Equipment.
Precision Data Acquisition
The OPA4187ID is well suited to multichannel precision data-acquisition modules where low offset drift helps preserve DC measurement accuracy as ambient temperature changes. Its four integrated channels can condition outputs from resistive sensors, low-level voltage sources, or external converters while reducing the number of separate amplifier packages. The 0.001 µV/°C input-offset drift is particularly useful when calibration intervals are long or measurements must remain traceable over -40°C to +125°C. Place each channel's input-filter network close to the source and use matched resistor layouts to minimize temperature gradients. The 36 V maximum supply rating also provides headroom for protected industrial front ends, although signal levels must remain inside the amplifier's common-mode and output limits.
Recomendado
Industrial Sensor Conditioning
OPA4187ID can serve as the precision gain stage for bridge, thermocouple, pressure, and other low-level industrial sensor interfaces. Its zero-drift architecture targets an input-offset voltage drift of 0.001 µV/°C, reducing one source of temperature-dependent measurement error at the front of the signal chain. Four channels allow a compact multi-sensor module without requiring four separate amplifier packages. MUX-friendly inputs are beneficial when one analog measurement circuit serves several sensors through a multiplexer. The design should still account for sensor excitation noise, resistor tolerance, common-mode voltage, and input bias current. Keep sensitive input traces away from switching regulators and power inductors, and establish the common-mode operating range from the manufacturer datasheet before selecting gain and bias resistors.
Recomendado
Laboratory Instrumentation
The OPA4187ID fits laboratory instruments that require accurate amplification of small DC signals and benefit from stable offset behavior. A four-channel arrangement can support programmable gain, active filtering, excitation, and reference-conditioning stages within one analog module. Its low power characteristic makes it relevant to compact bench instruments, while the -40°C to +125°C rating supports equipment designed for industrial environments as well as controlled laboratory use. The MUX-friendly inputs can simplify relay- or switch-based input selection in automated test systems. Designers should still compare noise density, gain-bandwidth product, input bias current, and output-current capability against the signal bandwidth. Use low-noise reference components and guard sensitive nodes when measuring currents in the nanoamp-to-microamp range.
Recomendado
Battery Monitoring
OPA4187ID can amplify low-level voltage-divider signals in multi-cell battery monitoring systems where offset movement would otherwise create measurement error across temperature. Its 0.001 µV/°C drift supports stable sensing of pack voltage, cell imbalance, current-shunt voltage, and temperature-derived compensation signals. Four amplifier channels can consolidate several analog measurements into a compact control board. The 36 V maximum supply rating accommodates protected high-voltage front ends when the individual inputs remain within the permitted common-mode range. A practical implementation should use high-value matched divider resistors, Kelvin connections at the shunt, and filtering that balances response time against noise. Verify supply current and channel behavior at the lowest operating voltage because battery-powered designs are sensitive to static and switching losses.
Recomendado
Process-Control Modules
OPA4187ID is appropriate for analog process-control modules that condition low-level sensor outputs before conversion or actuation. Its low offset drift improves the stability of pressure, flow, level, and temperature loops, particularly where equipment must operate across a wide ambient-temperature range. Four channels support dense I/O designs, and the MUX-friendly input characteristic is useful when several analog inputs share a scanner. The amplifier can be used around current-shunt, bridge, and differential-sensor front ends when the common-mode and supply requirements are satisfied. Place protection components ahead of the inputs where industrial transients are possible, and provide clean references and grounding to avoid injecting noise into the control loop. Check settling behavior and stability with the actual sensor capacitance before finalizing the feedback network.
Recomendado
Medical and Diagnostic Equipment
OPA4187ID can support low-level analog front ends in diagnostic and medical instrumentation where temperature-stable offset is important, provided the application meets the device's electrical and qualification requirements. Four channels allow the same amplifier architecture to process several biosensor, bridge, or buffer signals in a compact instrument. The 0.001 µV/°C drift helps limit changes in measurement baseline as the equipment experiences its specified temperature range. Design teams must add the appropriate input protection, isolation, leakage control, and filtering required by the medical system, and must independently assess all applicable safety and quality requirements for the finished product. Low-leakage PCB materials, guard structures, clean references, and short sensitive routes are especially important when source impedances are high.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para OPA4187ID — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | OPA4187IDR |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 14-pin SOIC | 14-pin SOIC - same footprint |
| Amplifier Channels | 4 | 4 |
| Offset Voltage Drift | 0.001 µV/°C | 0.001 µV/°C |
| Maximum Supply Voltage | 36 V | 36 V |
| Output Swing | Rail-to-rail | Rail-to-rail |
| Input Multiplexer Compatibility | MUX-friendly | MUX-friendly |
| Operating Temperature | -40°C to +125°C | -40°C to +125°C |
Principais diferenciais
- Very low temperature coefficient for precision DC measurements (vs OPA4187IDR)
- Four precision channels in one 14-pin SOIC (vs OPA2187ID)
- MUX-friendly precision input architecture (vs OPA4187IPWR)
Notas de projeto
Place the required supply-decoupling capacitors immediately adjacent to the OPA4187ID power and ground pins. Route sensitive noninverting and inverting inputs away from switching nodes, clock signals, and high-current return paths. For high-impedance sensors, keep PCB contamination and humidity under control because leakage across the input board can create errors larger than the amplifier's 0.001 µV/°C offset drift.
Use a symmetric layout for differential channels and keep the two sides of each precision feedback network physically matched. Where four channels measure similar signals, consistent component orientation helps reduce thermal-gradient and parasitic differences between channels. Connect exposed analog grounds according to the manufacturer layout guidance and keep return currents from digital converters and switching regulators out of the precision signal-return path.
Do not assume that every OPAx187 family member is a direct replacement for OPA4187ID. The ID ordering option uses a 14-pin SOIC, while other family orderings use TSSOP or WQFN packages and therefore require different PCB footprints. Also confirm the input common-mode range, output swing, gain-bandwidth product, input bias current, and stability with the intended sensor impedance before approving an equivalent or changing the feedback network.
Informações de conformidade
The OPA4187 family information and part ordering pages do not provide enough compliance detail to assign a definite status. The operating-temperature range is -40°C to +125°C; automotive qualification is not established by that temperature rating.