TJA1041AT/VM - 1Mbit/s High-Speed CAN Transceiver | NXP
N.º da peça: TJA1041AT/VM ✗ Fim de vidaTJA1041AT/VM Visão geral
A CAN transceiver is the physical-layer interface within a Controller Area Network node. A CAN protocol controller generates and interprets CAN frames, while the transceiver converts between the controller's digital TXD and RXD signals and the differential CANH and CANL bus wires. This interface belongs to the hierarchy of CAN interface IC, communication transceiver, network interface, and semiconductor. Its differential bus operation supports noise-resistant communication over cables and PCB interconnects in automotive and industrial networks.
The principal operating specification is support for high-speed CAN communication up to 1 Mbit/s. The device combines differential bus output with differential input reception, allowing a CAN controller to transmit dominant states and detect recessive states from the bus. A 14-pin SOIC package supports conventional surface-mount assembly, while the extended ambient-temperature specification of -40°C to +105°C suits industrial and automotive environments where temperature variation is significant.
The TJA1041A architecture is designed specifically for connection between a CAN protocol controller and a physical CAN bus. Its transmit path drives the differential CANH and CANL conductors, and its receive path presents the bus state to the controller through RXD. Because the interface operates differentially, the receiver evaluates the voltage relationship between CANH and CANL rather than relying on a single conductor referenced only to ground, improving common-mode noise rejection in vehicle and industrial networks.
Typical applications include automotive body and powertrain electronic control modules, industrial automation equipment, transport systems, embedded CAN gateways, and other distributed control networks. The part is most appropriate where the selected CAN controller uses a 3.3 V or 5 V TXD/RXD interface and the system requires the established 14-pin high-speed CAN transceiver footprint. Designers must still verify signal levels, loopback behavior, bus timing, and transceiver-mode requirements against their controller and network design.
A critical design consideration is that an end-of-life status does not make a legacy transceiver automatically interchangeable with a newer CAN transceiver. Pin placement alone is insufficient: replacement devices can differ in standby, sleep, wake-up, split-mode, VIO, loopback, and bus-failure behavior. Validate the complete transceiver state machine, electrical limits, timing, and firmware expectations before using another MPN on an existing PCB.
This product page combines the manufacturer's operating description, lifecycle status, package information, temperature range, replacement guidance, and pin-compatible family alternatives with practical selection and design notes. It is intended to accelerate engineering review by separating true footprint compatibility from broader functional similarity and by highlighting the checks required when maintaining an established automotive or industrial CAN design.
Alternativas drop-in para TJA1041AT/VM — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Variantes desta série
Modelos da mesma série compatíveis como drop-in com TJA1041AT/VM (mesmo formato e footprint).
TJA1041T/VM
✅ Drop-In ⚠️ Especificações não verificadasConsulte o preço
Ver ficha técnica →TJA1041AT/CM
✅ Drop-In ⚠️ Especificações não verificadas📋 Alternativa de referência (fora do catálogo)
TJA1041AT/VM Especificações
| Product Type | High-speed CAN transceiver |
| Maximum CAN Data Rate | 1 Mbit/s |
| Transceiver Configuration | 1/1 half transceiver |
| Bus Interface | Differential CANH/CANL |
| Controller Interface | Differential transmit and differential receive |
| Application | Automotive high-speed CAN |
| Encapsulamento | 14-pin SOIC |
| Tipo de montagem | Surface mount |
| Operating Ambient Temperature | -40°C to +105°C |
Guia de Configuração de Pinos do TJA1041AT/VM 14-pin soic
Configuração de pinos para TJA1041AT/VM (pacote 14-pin soic). A numeração dos pinos, funções e diagramas de conexão estão definidos no datasheet do fabricante. Consulte-o para o footprint exato e diretrizes de soldagem.
Nenhum dado detalhado de pinagem disponível para TJA1041AT/VM.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
TJA1041AT/VM é adequado para 6 aplicaçãos: Automotive Body Control Module, Industrial PLC CAN Module, Transport and Rail Control Network, Embedded CAN Gateway, Sensor and Actuator Network Hub, Maintenance and Test Equipment.
Automotive Body Control Module
The TJA1041AT/VM fits an automotive body-control module that connects a CAN controller to a high-speed vehicle network. Its differential transmit and receive paths support CANH/CANL communication up to 1 Mbit/s, while the 14-pin SOIC package enables conventional surface-mount assembly. The -40°C to +105°C ambient range supports thermally varied vehicle environments. Engineers should confirm logic levels, mode-control behavior, transceiver timing, and network fault tolerance against the selected CAN controller before releasing the PCB.
Recomendado
Industrial PLC CAN Module
In an industrial PLC or distributed automation module, the TJA1041AT/VM provides the physical layer between a CAN controller and fieldbus wiring. Operation up to 1 Mbit/s permits high-speed communication when the network topology, cable length, and node count permit it. Differential CANH/CANL signaling improves robustness in electrically noisy equipment rooms. The extended -40°C to +105°C temperature range supports industrial deployments, but designers must verify grounding, termination, isolation strategy, and EMC requirements.
Recomendado
Transport and Rail Control Network
The TJA1041AT/VM is applicable to transport, rail, and mobile-equipment control modules requiring a high-speed CAN physical interface. Its 1 Mbit/s capability supports communication among distributed controllers, while the differential bus interface helps reject common-mode disturbance encountered in long wiring harnesses. The 14-pin SOIC package is appropriate for compact controller boards, and the -40°C to +105°C range covers demanding ambient conditions. Network designers should still perform worst-case bus-length, termination, and transient-immunity analysis.
Recomendado
Embedded CAN Gateway
An embedded gateway can use the TJA1041AT/VM to connect a microcontroller or dedicated CAN controller to a high-speed CAN network. The transceiver translates digital TXD and RXD controller signals into differential CANH/CANL bus signaling, allowing the gateway to exchange frames with remote nodes at rates up to 1 Mbit/s. Its 14-pin SOIC package keeps the interface compact, and the wide temperature range supports industrial gateways. Firmware must coordinate the controller's operating mode with the transceiver's wake, sleep, and standby behavior.
Recomendado
Sensor and Actuator Network Hub
A CAN-based sensor or actuator hub can use the TJA1041AT/VM as the bus-facing interface for a local controller. Differential CANH/CANL communication supports reliable operation across shared wiring and equipment with differing ground potentials, subject to correct bus topology and termination. The 1 Mbit/s capability allows the hub to aggregate fast control messages, while the -40°C to +105°C operating range accommodates industrial environments. Verify the maximum node count, cable length, and controller timing before finalizing the network design.
Recomendado
Maintenance and Test Equipment
The TJA1041AT/VM can provide the CAN node interface in portable diagnostics, commissioning tools, and industrial test equipment. The high-speed CAN capability enables efficient exchange of diagnostic frames, while differential bus signaling supports dependable operation when connected to equipment harnesses. Its 14-pin SOIC package simplifies board assembly, and the broad temperature range suits varied field conditions. Test-system designers should account for the lifecycle plan, software expectations for mode control, and test fixtures that reproduce the target bus's termination and fault conditions.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para TJA1041AT/VM — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | TJA1041T/VM | TJA1041AT/CM |
|---|---|---|---|
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors |
| Package | SOIC-14 | SOIC-14 | SOIC-14 |
| Product Type | High-speed CAN transceiver | High-speed CAN transceiver | TJA1041A high-speed CAN transceiver |
| Maximum CAN Data Rate | 1 Mbit/s | 1 Mbit/s | 1 Mbit/s |
| Bus Interface | Differential CANH/CANL | Differential CANH/CANL | Differential CANH/CANL |
| Controller Interface | Differential transmit and receive | Differential transmit and receive | Differential transmit and receive |
| Primary Application | Automotive high-speed CAN | High-speed CAN | High-speed CAN |
Principais diferenciais
- Retains the established 14-pin high-speed CAN interface (vs TJA1041T/VM)
- Provides a direct same-family migration path (vs TJA1041AT/CM)
- Documented extended-temperature suitability (vs TJA1041AT/CM)
Notas de projeto
Do not treat every 14-pin CAN transceiver as an automatic replacement. Confirm the pin table, TXD and RXD logic levels, VCC range, standby or sleep control, loopback implementation, and bus-failure behavior. The TJA1041AT/VM is end-of-life, so an existing PCB should be compared against the manufacturer pin table and the replacement device's timing characteristics before population changes are authorized.
Route CANH and CANL as a tightly coupled differential pair over a continuous ground plane, minimize stubs and unprotected branch lengths, and place the 120-ohm termination at each physical end of the bus. Keep the transceiver close to the CAN controller and place required decoupling and mode-control components according to the manufacturer layout guidance. Avoid routing the pair through switching-power regions or discontinuous reference planes.
Verify the complete network operating envelope, including maximum node count, total cable length, termination placement, common-mode voltage, and controller bit timing. A transceiver capable of 1 Mbit/s does not guarantee that every topology supports that rate. Check dominant-state timing, loopback behavior, bus-off recovery, and low-power transitions in hardware and firmware.
Informações de conformidade
The manufacturer identifies the TJA1041AT family for automotive high-speed CAN applications, but explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals statements are not specified here.