NXP Semiconductors

TJA1050 - High-Speed CAN Transceiver, 5V | NXP Semiconductors

N.º da peça: TJA1050 ✗ Fim de vida
Em estoque Enviado em 1 a 3 dias úteis
4.75 V to 5.25 V Vdss SOIC-8 (TJA1050T/CM,118) Package
A partir de $0.84 USD / unidade
MOQ: 1 |
Preço atualizado: 2026-10-16
Preços por volume
Qtd. Preço unitário Total
1 $1.62 $1,62
10 $1.46 $14,60
100 $1.18 $118,00
500 $0.97 $485,00
1.000 $0.84 $840,00
ℹ️ Todos os preços estão em USD

TJA1050 Visão geral

The NXP TJA1050 is a high-speed Controller Area Network (CAN) transceiver that provides the physical interface between a CAN protocol controller and the physical CAN bus, supporting data rates up to 1 Mbit/s in a standard 8-pin SO (SOIC-8) package. Designed for 5V supply operation, the TJA1050 delivers excellent electromagnetic compatibility (EMC) performance and very low power consumption, making it well-suited for both industrial and automotive applications.

A CAN transceiver is an interface IC that sits between a microcontroller's CAN protocol controller and the differential CANH/CANL bus wires. Its hierarchical role is: CAN transceiver → bus interface IC → interface integrated circuit → semiconductor. The TJA1050 family forms part of NXP's third-generation high-speed CAN transceivers, succeeding earlier devices like the PCA82C250 with improved slope control, lower electromagnetic emissions, and integrated protection features against bus shorts and transient voltages.

Key features include an operating supply voltage range of 4.75V to 5.25V, low quiescent current consumption, integrated thermal protection, and a recessive bus output voltage that approximates the supply voltage (VCC) for improved logic-level compatibility. The device supports both normal and silent (standby-like) modes selected via the S pin and provides differential transmit/receive capability across an extended common-mode range on the bus. Differential receiver thresholds are tightly controlled to support CAN-FD-ready bit timing in many classic CAN networks.

The architecture uses a current-driven recessive output and a dominant-driving topology with slope control to minimize ringing and RF emissions. An internal watchdog and thermal shutdown safeguard the die against bus shorts to battery or ground, while an undervoltage detection circuit disables the transmitter when VCC drops below the operational threshold to prevent erroneous bus states during power-up or power-down sequences.

Typical applications include automotive body control modules, industrial CAN-based sensor networks, building automation gateways, and battery management systems where galvanic isolation can be implemented with a transformer or capacitive barrier after the transceiver stage. The TJA1050 is commonly paired with 8-bit or 32-bit microcontrollers that include an integrated CAN controller, such as NXP's LPC and S32K families.

When designing with the TJA1050, place a 120 Ω termination resistor at each end of the CAN bus segment and keep the stub length under roughly 30 cm at 1 Mbit/s. Decouple VCC with a 100 nF ceramic capacitor close to the supply pin, and provide adequate ground plane coverage under the bus traces to maintain the differential impedance target of 120 Ω.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet.

Alternativas drop-in para TJA1050 — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Variantes desta série

Modelos da mesma série compatíveis como drop-in com TJA1050 (mesmo formato e footprint) — diferindo em Operating Temperature, Package, Maximum Data Rate, Product Type, Protocol.

Texas Instruments
Operating Temperature: -40C to +85C
Package: 8-SOIC (D)
Maximum Data Rate: 1 Mbps
Comparar com TJA1050 →
NXP Semiconductors
Operating Temperature: -40C to +125C
Package: SO-8 (8-pin SOIC)

Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:

TJA1051T/3/1

✅ Drop-In
NXP Semiconductors
📦 SO-8
High-speed CAN transceiver · Up to 1 Mbit/s · 4.5 V to 5.5 V · 3 V to 5 V · Classical CAN, CAN FD · Half duplex, 1 driver / 1 receiver · SO-8 (8-pin SOIC) · Surface Mount

✓ Em estoque

$0.4102 / unidade

Ver ficha técnica →

TJA1057T/3

✅ Drop-In
📦 SO-8
Same SO-8 footprint, improved EMC performance vs TJA1050; identical 5V supply range 4.75-5.25V and 1 Mbit/s max data rate

📋 Alternativa de referência (fora do catálogo)

TJA1040T

✅ Drop-In
📦 SO-8
Pin compatible per NXP datasheet; adds low-current standby mode with remote wake-up vs TJA1050 (a feature increment, same SO-8 footprint)

📋 Alternativa de referência (fora do catálogo)

SN65HVD230DR

✅ Drop-In
Texas Instruments
📦 SOIC-8
CAN Bus Transceiver · 1/1 · CANbus (ISO 11898-2) · 3 V to 3.6 V (3.3 V nominal) · 1 Mbps · Half-Duplex · 370 uA typical · Exceeds 16 kV

✓ Em estoque

$0.94 / unidade

Ver ficha técnica →

SN65HVD1050A-Q1

✅ Drop-In
📦 SOIC-8
Same SOIC-8 footprint, 5V supply, AEC-Q100 automotive qualified, VREF pin behavior differs (-1 differential key spec vs TJA1050)

📋 Alternativa de referência (fora do catálogo)

TJA1050 Especificações

Product Type High-speed CAN transceiver
Supply Voltage (VCC) 4.75 V to 5.25 V
Maximum Data Rate 1 Mbit/s
Number of Drivers/Receivers 1/1
Protocol CAN 2.0A/B (classic CAN); controller-side interface only
Bus Fault Protection Short to battery, short to ground, thermal shutdown
Temperatura de operação -40 C to +150 C
Standby/Mode Pin Yes (S pin, silent mode)
Encapsulamento SOIC-8 (TJA1050T/CM,118)
Tipo de montagem Surface Mount
Nível MSL 1
Status RoHS Compliant

Configuração de pinos do TJA1050

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pino 1 TXD — Transmit data input from CAN controller (TTL-level referenced to VCC)
Pino 2 GND — Ground reference for logic and bus drivers
Pino 3 VCC — +5V supply input (4.75V to 5.25V operating range)
Pino 4 RXD — Receive data output to CAN controller (recessive = logic HIGH, dominant = LOW)
Pino 5 VREF — Common-mode reference voltage output (approx 0.5 × VCC) for external biasing
Pino 6 CANL — Low-level CAN bus line (differential pair with CANH)
Pino 7 CANH — High-level CAN bus line (differential pair with CANL)
Pino 8 S — Silent mode select input (HIGH = normal, LOW = high-Z bus / standby)

Aplicações típicas

TJA1050 é adequado para 6 aplicaçãos: Automotive Body Control Modules, Industrial CAN Sensor Networks, Battery Management Systems (BMS), Building Automation Gateways, Industrial Lift and Elevator Control, CAN-Based Embedded Instrumentation.

🚗

Automotive Body Control Modules

The TJA1050's 5V single-supply rail (4.75-5.25V) and -40C to +150C operating range map directly to automotive body-electronics environments such as BCMs, door modules, and HVAC controllers. Placed between an NXP S32K or LPC microcontroller's CAN controller and the bus, it converts TTL-level TXD/RXD into differential CANH/CANL signaling up to 1 Mbit/s with very low electromagnetic emissions thanks to the integrated slope control. Unlike a discrete optocoupler + bus driver, the TJA1050 integrates thermal shutdown, undervoltage detection, and bus-fault protection in one SO-8 die, reducing PCB area by ~60% in typical node designs and improving reliability against shorts to battery or ground.

🏭

Industrial CAN Sensor Networks

In factory-floor sensor and actuator backbones based on CANopen or DeviceNet, the TJA1050 provides robust differential signaling across cable lengths up to a few hundred meters at 125 kbit/s. Its high common-mode rejection and integrated slope control suppress ringing on long stub connections without external EMC components, supporting up to 32 nodes per segment per ISO 11898-2 when 120 Ω termination is applied at each end. Compared to slower RS-485 transceivers, the TJA1050's hardware-based arbitration and frame-level error confinement reduce firmware complexity and enable deterministic latency for real-time control loops in industrial automation.

🔋

Battery Management Systems (BMS)

Within a 12V/48V battery management system, the TJA1050 connects the slave monitoring boards (cell-voltage and temperature acquisition) to the master controller via a CAN backbone, isolating MCU-side logic from the noisy battery environment. The 5V VCC ties directly to onboard low-dropout regulators, and the differential bus rejects common-mode noise from inverter switching or motor commutation in the same chassis. Its very low quiescent current in recessive state is acceptable for systems that sleep periodically, although for deep-sleep nodes the TJA1051 with sub-10 uA standby is preferred.

🏢

Building Automation Gateways

Building-automation platforms (BACnet over MS/TP, KNX, or proprietary CAN-based protocols) often use the TJA1050 in gateway nodes that bridge Ethernet to a CAN-based fieldbus segment. The TJA1050's stable recessive bus biasing and fast loop times support real-time polling of HVAC controllers and lighting nodes without the need for an external isolator in low-voltage installations. Unlike Ethernet PHYs, the TJA1050 consumes far less board area and draws tens of milliwatts, making it ideal for compact DIN-rail gateways where thermal dissipation is constrained.

🏗️

Industrial Lift and Elevator Control

The TJA1050's wide common-mode range and robust bus-fault handling make it a long-standing candidate for elevator control panels and lift shaft networks where CAN carries safety messages between floor controllers, the hoist machine, and door interlocks. Its dual-shorted-bus protection keeps the network operational under wiring damage common during installation, and the high-EMI immunity satisfies EN 12016 / EN 12015 emissions requirements when paired with proper cable shielding. Compared to isolated 4-20 mA loops, the TJA1050 multi-drop topology reduces cabling cost up to 30% per shaft.

🖥️

CAN-Based Embedded Instrumentation

Lab instruments, programmable power supplies, and motion controllers often use the TJA1050 as the service-port connection between the operator panel (CAN master) and per-channel daughtercards. Its 1 Mbit/s capability is sufficient for high-speed tune and trim loops in 4-axis stepper drivers, while the SO-8 footprint drops into legacy PCBs that were originally laid out for the PCA82C250. Engineers should evaluate the silent-mode (S-pin) behavior if the instrument needs selective node deactivation during test sequences.

Resumo dos produtos recomendados

S32K144 Automotive MCU with integrated CAN controller Usado em: Automotive Body Control Modules, Battery Management Systems (BMS), CAN-Based Embedded Instrumentation TJA1051T/3 Next-generation drop-in upgrade for migration Usado em: Automotive Body Control Modules, Building Automation Gateways TLE9251V Alternative CAN transceiver for new designs Usado em: Automotive Body Control Modules LPC1768 Cortex-M3 MCU with on-chip CAN controller Usado em: Industrial CAN Sensor Networks, Industrial Lift and Elevator Control TJA1057T/3 Second-source NXP CAN transceiver Usado em: Industrial CAN Sensor Networks, Industrial Lift and Elevator Control MC33771 Battery cell monitor IC Usado em: Battery Management Systems (BMS) LPC54618 Cortex-M4 MCU with Ethernet MAC and CAN Usado em: Building Automation Gateways MAX1978 Peltier temperature controller with CAN option Usado em: CAN-Based Embedded Instrumentation
What is the TJA1050 used for?
The TJA1050 is a high-speed CAN bus transceiver that interfaces a microcontroller's CAN protocol controller to the physical CANH/CANL differential bus, supporting data rates up to 1 Mbit/s. According to the NXP datasheet, it is designed for 5V supply operation (4.75V to 5.25V) and is widely used in automotive body electronics, industrial sensor networks, and embedded CAN nodes that require robust EMC performance and bus-fault protection.
Is the TJA1050 still in production?
The TJA1050 is currently classified as Not Recommended for New Designs (NRND) by NXP, with the part being actively phased out in favor of newer generations such as the TJA1051 and TJA1057. As of 2026-10-16, the TJA1050T/CM,118 remains listed at authorized distributors including DigiKey, but lead times may extend and NXP recommends migrating designs to TJA1051T/3 or TJA1057T/3 for new projects.
What is the maximum CAN bus data rate of the TJA1050?
The TJA1050 supports data rates up to 1 Mbit/s, conforming to the ISO 11898-2 high-speed CAN physical layer standard. According to the NXP product specification, bit timing is determined by the connected CAN controller, and the transceiver itself imposes no protocol-level rate ceiling below 1 Mbaud, although bus length must be shortened as data rate increases to preserve signal integrity.
What is the difference between TJA1050 and TJA1051?
The TJA1051 is NXP's third-generation high-speed CAN transceiver, succeeding the TJA1050 with significantly improved EMC and ESD performance, plus additional features such as a low-power standby mode with remote wake-up capability. Both parts share a similar 8-pin SO pinout for drop-in compatibility in many designs, but the TJA1051 additionally supports CAN FD-ready bit rates in the 2 Mbit/s range on optimized bus topologies.
Can a TJA1050 be replaced by a TJA1057?
The TJA1057 is another NXP third-generation high-speed CAN transceiver offering pin compatibility with the TJA1050 in the standard SO-8 footprint, providing improved EMC/ESD performance. Engineers should verify that the S (silent) pin behavior, supply voltage range, and standby current match the application's requirements before substituting the TJA1057 for the TJA1050 in an existing PCB layout, since minor register or timing differences may apply.
Where can I download the TJA1050 datasheet PDF?
The official TJA1050 datasheet is hosted directly on NXP's product documentation portal at https://www.nxp.com/docs/en/data-sheet/TJA1050.pdf. The document is titled 'TJA1050 High speed CAN transceiver - Product specification' and supersedes the 2002 May 16 revision. The PDF covers electrical characteristics, pin configuration, functional description, and application hints for the SO-8 (TJA1050T/CM,118) and DSO-8 variants.
What is the pinout of the TJA1050 in SO-8?
The TJA1050 SO-8 pinout assigns pin 1 to TXD (transmit data input from the controller), pin 2 to GND, pin 3 to VCC, pin 4 to RXD (receive data output to the controller), pin 5 to VREF (common-mode reference voltage), pin 6 to CANL, pin 7 to CANH, and pin 8 to S (silent mode select). According to the NXP datasheet, pin 1 is identified by the standard SO-8 dot marker at the top-left when reading the part marking from above.
What supply voltage does the TJA1050 require?
The TJA1050 operates from a nominal 5V supply, with the datasheet specifying a VCC operating range of 4.75V to 5.25V. Operation outside this window may cause the transmitter to enter an undervoltage-protected state, during which the bus outputs are high-impedance to prevent erroneous dominant bits. For 3.3V-only systems, the TI SN65HVD230 is a common substitute and runs directly from a 3.3V rail, although it is not a pin-compatible drop-in.
What is a drop-in replacement for the TJA1050?
For pin-compatible drop-in replacement, the NXP TJA1051T/3 and NXP TJA1057T/3 are the closest second-source options sharing the SO-8 footprint and basic pin function. According to manufacturer cross-reference data, both newer devices deliver improved EMC/ESD performance and lower standby current; however, designers must revalidate silent-mode behavior and VREF pin function before swapping in production hardware, because these differ slightly from the TJA1050.
Can the TJA1050 work in a 3.3V microcontroller system?
No, not directly. The TJA1050's TXD and RXD logic thresholds assume a 5V VCC, so connecting it to a 3.3V microcontroller requires a level shifter or a 3.3V-capable alternative such as the TI SN65HVD230 or SN65HVD1050. According to the NXP datasheet, the TXD input is referenced to VCC and is not 5V-tolerant when VCC is below 5V; using the TJA1050 at 3.3V will compromise bus-dominant drive strength and may violate the CAN HIGH-level input threshold.
What are the key specifications engineers should know about the TJA1050?
The TJA1050 supplies 5V single-rail operation (4.75-5.25V), 1 Mbit/s maximum CAN bus speed, half-duplex differential signaling on CANH/CANL, integrated short-circuit and thermal protection, and an SO-8 surface-mount package. According to the NXP datasheet, the device supports silent mode via the S pin for reduced quiescent current, and it is rated for the -40C to +150C automotive temperature range, covering most industrial and in-cabin automotive environments.
How much does a TJA1050 cost in 2026?
The TJA1050T/CM,118 is listed on DigiKey at approximately 1.62 USD per unit at qty 1, scaling down to roughly 0.84 USD at qty 1000 as of 2026-10-16. Prices from authorized distributors such as Mouser and Avnet are comparable, while unauthorized brokers may quote lower but carry elevated counterfeit risk - XAIPART validates against the manufacturer datasheet before shipping any part marked TJA1050.
Is the TJA1050 RoHS compliant?
Yes, the TJA1050T/CM,118 SOIC-8 variant is RoHS compliant per the manufacturer product page, with lead-free (Pb-free) matte-tin terminations and a maximum peak reflow temperature of 260C in accordance with JEDEC J-STD-020. The MSL moisture sensitivity classification for this package is 1, meaning unlimited floor life at less than 30C / 85% RH, which simplifies logistics for high-volume production.
TJA1050 vs TJA1051 vs TJA1057 - which should I choose?
For new designs, prefer the TJA1051T/3 or TJA1057T/3 over the aging TJA1050, since both successors offer improved EMC, better ESD robustness, and lower standby current. The TJA1050 remains a valid choice for legacy boards already in production where the supply voltage, pinout, and silent-mode behavior are validated, but for AEC-Q100 automotive qualification, the -Q1 suffix variants of the TJA1051 are required.
Does the TJA1050 support CAN FD?
The TJA1050 is a classic CAN 2.0A/B transceiver and does not feature the enhanced bus-driver symmetry required for reliable CAN FD communication at data rates above 1 Mbit/s. For CAN FD networks, NXP recommends the TJA1051 or TJA1057 families, which are designed to support the higher data rates and tighter bit-timing requirements of ISO 11898-1:2015. Substituting the TJA1050 in a CAN FD segment may produce bit errors during the data phase at 2 Mbit/s and above.

Dados de referência de engenharia para TJA1050 — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the TJA1050 only when maintaining a legacy 5V CAN node where revalidation cost dominates the cost of switching to a newer transceiver. For new designs, prefer the NXP TJA1051T/3 (CAN FD ready, improved EMC, sub-10 µA standby with wake-up) or TJA1057T/3 (improved EMC at the same 1 Mbit/s ceiling). For 3.3V-only MCUs, choose the TI SN65HVD230DR; for AEC-Q100 automotive programs, choose the SN65HVD1050A-Q1 or TJA1051T/3-Q1. All four alternates share the SO-8 footprint, so PCB layout can be carried across the family with pinout-only validation.

Comparação com alternativas

Parâmetro Este produto TJA1051T/3 TJA1057T/3 TJA1040T SN65HVD230DR SN65HVD1050A-Q1
Package SOIC-8 (TJA1050T/CM,118) SO-8 (same) SO-8 (same) SO-8 (same) SOIC-8 (same) SOIC-8 (same)
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors Texas Instruments Texas Instruments
Supply Voltage 4.75V to 5.25V 4.5V to 5.5V 4.75V to 5.25V 4.75V to 5.25V 3.0V to 3.6V 4.75V to 5.25V
Maximum Data Rate 1 Mbit/s Up to 5 Mbit/s (CAN FD ready) 1 Mbit/s 1 Mbit/s 1 Mbit/s 1 Mbit/s
Standby / Silent Mode Silent mode via S pin Standby with remote wake-up Silent mode via S pin Low-current standby with wake-up Silent mode via Rs pin Silent mode via Rs pin
CAN FD Support No (Classic CAN 2.0A/B only) Yes No No No No

Principais diferenciais

  • Sustained 5V supply band for legacy automotive body ECUs (vs SN65HVD230)
  • Third-generation EMC/ESD successors with same SO-8 footprint (vs TJA1051T/3)
  • Long-term availability through authorized channels (vs TJA1057T/3 (or other -Q1 AEC-Q100 alternates))

Notas de projeto

Power the TJA1050 from a regulated 5V rail with a 100 nF X7R ceramic decoupling capacitor placed within 5 mm of the VCC pin. Add a 10 µF bulk capacitor on the same rail to suppress transient currents during dominant-to-recessive switching events. The TXD input is referenced to VCC, so a 3.3V MCU cannot drive it directly without violating the HIGH-level input threshold (typically 0.7 × VCC). For 3.3V CAN systems, the TI SN65HVD230 is the typical pin-compatible substitute, since it shares the SO-8 footprint.

Route the CANH and CANL lines as a tightly coupled differential pair with 120 Ω characteristic impedance; keep both traces on the same layer and avoid splitting them across a plane cut. Stubs to the transceiver should be under 30 mm at 1 Mbit/s to limit reflections; place the 120 Ω termination resistors only at the two farthest ends of the bus segment, not on every node. Provide a solid uninterrupted ground plane directly under the bus traces to maintain the controlled-impedance reference.

Do not apply a negative VCC (sub-zero supply) or backfeed the bus: the TJA1050 bus pins are protected against ±25 V transient bus shorts per IEC 61000-4-2, but sustained over-voltage will damage the die. When migrating designs to a TJA1051 or TJA1057, verify the VREF pin behavior - the TJA1050 uses VREF for an internal bias reference (about 0.5 × VCC), while the SN65HVD1050A-Q1 ties VREF to a stronger common-mode driver; the two are NOT always software-compatible. Avoid driving TXD while VCC is below 4.75V because the undervoltage detector will tri-state the bus, potentially causing an incomplete dominant bit that confuses other nodes on the network.

Estimated: at ambient 85 C with bus short (CANH shorted to VCC), the TJA1050's internal thermal shutdown activates near 170 C junction. In a properly designed node with default bus loading, the part dissipates well under 100 mW (estimated: 5V × 20 mA quiescent), so no heatsink is required. However, when the bus is repeatedly driving into a shorted cable during installation tests, the SO-8 θJA of approximately 150 C/W will allow the junction to climb quickly - ensure the surrounding copper area is at least 0.5 sq.in. to avoid nuisance thermal shutdown.

Informações de conformidade

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Sem chumbo
Yes
Sem halogênios
Yes
Minerais de conflito
Compliant

RoHS and REACH compliance per manufacturer product page. TJA1050 is NRND; for AEC-Q100-qualified variants use TJA1051/Q1 or TJA1057/Q1 instead. MSL 1 per JEDEC J-STD-020 for SO-8 package.

Dados verificados em: 2026-10-16 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

TJA1050 TJA1050 datasheet PDF TJA1050 NXP high speed CAN transceiver TJA1050 SO-8 pinout TJA1050 5V CAN transceiver 1 Mbit/s TJA1050 automotive body control module TJA1050 vs TJA1051 TJA1050 drop-in replacement TJA1050 buy price What is a CAN transceiver TJA1050 pinout VREF function 5V CAN bus interface SOIC-8 TJA1050 obsolete alternative TJA1050 NRND migration guide

Componentes & termos relacionados

NXP Semiconductors TJA1050 TJA1050T/CM,118 TJA1051T/3 TJA1057T/3 TJA1040T SN65HVD230DR SN65HVD1050A-Q1 CAN transceiver CAN bus CAN 2.0A/B CAN FD Controller Area Network ISO 11898-2 high-speed CAN differential signaling CANH/CANL TXD RXD silent mode ROHS REACH AEC-Q100 JEDEC J-STD-020 SO-8 SOIC-8 surface-mount NXP S32K144 industrial CAN automotive body electronics
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
Total: $0.00 USD
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue
Ver detalhes da RFQ