SI3016-FS vs SI3016-BS Сравнение
Подробное сравнение бок о бок SI3016-FS от Skyworks Solutions и SI3016-BS от Skyworks Solutions. Сравните ключевые характеристики, электрические параметры, упаковку, статус жизненного цикла, цены и наличие, чтобы выбрать лучший компонент для ваших требований.
Сравнение характеристик
| Параметр | SI3016-FS | SI3016-BS |
|---|---|---|
| Бренд | Skyworks Solutions | Skyworks Solutions |
| Категория | Interface ICs | Interface ICs |
| Статус жизненного цикла | Активен | Unknown |
| Наличие | In Stock | In Stock |
| Цена за единицу (USD) | $3,76 | $0,00 |
| Product Type | Integrated direct access arrangement (DAA) line-side device | Enhanced global direct access arrangement (DAA) and V.90 modem IC |
| Modem Standard | V.90 | — |
| Напряжение питания | 3.3 V | 3.3 V |
| Line Interface | Programmable telephone-line interface | Programmable |
| Корпус | 16-pin SOIC | 16-pin SOIC |
| Число выводов | 16 pins | — |
| Тип монтажа | Surface mount | Surface mount |
| Terminal Form | Gull wing | Gull wing |
| Package Shape | Rectangular | — |
| Package Code | SOP | — |
| Temperature Grade | Commercial | Industrial |
| Product Category | Modems - ICs and Modules | — |
| Interface Category | Telecom Interface ICs | — |
| Integrated Functions | Line-side DAA and programmable line interface | — |
| External AFE Requirement | Eliminated | — |
| External Isolation Transformer Requirement | Eliminated | — |
| External Relay Requirement | Eliminated | — |
| External Opto-Isolator Requirement | Eliminated | — |
| External 2- to 4-Wire Hybrid Requirement | Eliminated | — |
| Host Processor Interface | Silicon Laboratories integrated DAA system-side interface | — |
| Статус RoHS | [DATA_NEEDED: RoHS compliance] | [DATA_NEEDED: RoHS status] |
| REACH Status | [DATA_NEEDED: REACH compliance] | [DATA_NEEDED: REACH status] |
| Функция | — | Line-side device for processors with an integrated system-side DAA |
| Transmit and Receive Level | — | 3.2 dBm |
| On-Hook Line Monitor Current | — | 7 µA |
| Line Voltage Monitoring | — | Integrated |
| Loop Current Monitoring | — | Integrated |
| Handset Detection | — | Parallel |
| Overload Protection | — | Integrated |
| Terminal Count | — | 16 terminals |
| Digital Modem Class | — | V.90 |