ADG406BP - 16:1 ±15V Analog Multiplexer | Analog Devices
Артикул: ADG406BP ✓ АктивенADG406BP Обзор
An analog multiplexer is an interface IC that connects multiple signal sources to a shared input or measurement channel. By placing a multiplexer ahead of an amplifier, converter, or data-acquisition system, designers can reduce the number of external signal connections and consolidate control through digital address lines. The ADG406 family belongs to the hierarchy of analog switch, analog multiplexer, interface IC, and semiconductor.
The key feature of the ADG406BP is its combination of 16 channels, ±15 V operation, and LC2MOS construction. The four address inputs select the active channel, while the common output provides a single analog path for downstream signal processing. The monolithic CMOS implementation supports compact analog routing for instrumentation, data acquisition, industrial control, and test systems. Its PLCC package also provides a mechanically robust option for through-hole PCB assembly.
Analog Devices identifies the ADG406 as a production LC device. The manufacturer product page describes it as a high-performance 16-channel analog multiplexer using LC2MOS technology and operating from dual ±15 V supplies. Distributor records identify ADG406BP as a single 16:1 switch in a 28-pin PLCC package, with an 80 Ω on-resistance in one listing and 50 Ω in another. Consult the manufacturer datasheet for the exact test conditions, leakage limits, bandwidth, switching time, and electrical ratings applicable to the ADG406BP grade.
Typical uses include multiplexed data-acquisition systems, programmable instrumentation, industrial measurement interfaces, and analog test systems. In each case, the address logic can scan multiple sensor or instrument channels while a downstream ADC or signal-conditioning circuit processes the selected output. Keeping the selected path short helps maintain measurement consistency and reduces the number of front-panel or board-level connections.
The primary design consideration is signal integrity. Place the multiplexer close to the source of the selected signals, provide a stable ground reference, route the common output away from digital clocks and address lines, and use the recommended bypass capacitance. Account for on-resistance, charge injection, off-state leakage, and switching transients when defining error budgets. Confirm the complete pin assignment against the manufacturer pinout before laying out a new PCB.
This page combines the manufacturer's product definition with package, application, and replacement guidance. It also provides selection criteria and design notes intended to make the ADG406BP easier to evaluate for new analog-routing designs.
Аналоги без доработки для ADG406BP — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
ADG406BPZ
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
ADG406BP Характеристики
| Product Type | 16-channel analog multiplexer |
| Multiplexer Configuration | 16:1 |
| Number of Channels | 16 channels |
| Number of Switch Circuits | 1 circuit |
| Напряжение питания | ±15 V dual supply |
| On-Resistance | 50 Ω to 80 Ω |
| Address Inputs | 4 binary address inputs |
| Address Signals | A0, A1, A2, A3 |
| Switch Architecture | Monolithic CMOS LC2MOS |
| Common Output | 1 common analog output |
| Корпус | 28-pin PLCC |
| Package Dimensions | 11.51 mm × 11.51 mm |
| Тип монтажа | Surface mount |
Руководство по цоколевке ADG406BP в корпусе 11.51 mm × 11.51 mm
Цоколевка для ADG406BP (корпус 11.51 mm × 11.51 mm). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.
Нет подробных данных о распиновке для ADG406BP.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
ADG406BP подходит для 6 применениеs: Multiplexed Data Acquisition, Programmable Test and Measurement, Industrial Sensor Multiplexing, Precision Analog Signal Routing, Automated Instrumentation, Analog Communications Interface.
Multiplexed Data Acquisition
The ADG406BP fits a 16-channel data-acquisition front end when each sensor or test point must share one downstream analog path. Its 16:1 configuration and four binary address inputs A0 through A3 let a controller scan channels sequentially without requiring 16 separate front-end amplifier inputs. Operating from ±15 V makes it appropriate for bipolar instrumentation signals when the source amplitudes remain within the datasheet limits. Place the selected analog path close to the acquisition circuitry, keep address traces away from the common output, and include the manufacturer-recommended bypass capacitors. Account for on-resistance in the input impedance budget and for charge injection when converting the multiplexed signal with an ADC.
Рекомендуется
Programmable Test and Measurement
ADG406BP is useful in a programmable measurement system where multiple test nodes must be routed to a common instrument or measurement amplifier. The four address lines create 16 channel selections, reducing backplane wiring and simplifying firmware-controlled scan sequences. The 28-pin PLCC package is mechanically suitable for compact through-hole instrumentation, while ±15 V operation supports many bipolar test signals. Route the common output directly toward the measurement front end and keep relay drivers, clock signals, and switching transients away from the analog trace. Verify input overvoltage limits, off-channel leakage, and settling behavior in the manufacturer datasheet before defining measurement accuracy.
Рекомендуется
Industrial Sensor Multiplexing
The ADG406BP can consolidate up to 16 industrial sensor inputs into one common analog channel when a controller must monitor temperature, pressure, position, or resistance through a shared signal-conditioning path. Binary addressing provides a straightforward digital interface for PLC or embedded control systems, while the monolithic CMOS LC2MOS implementation supports the analog-switching role described by Analog Devices. Use a single low-impedance analog return to reduce ground offsets and place the multiplexer near the sensor interface rather than near digital processors. Include protection against industrial transients, verify the ±15 V supply tolerance, and design the downstream amplifier so on-resistance and leakage remain small relative to the sensor impedance.
Рекомендуется
Precision Analog Signal Routing
ADG406BP fits precision routing systems that need a repeatable way to connect one of several low-level analog sources to a common amplifier or converter input. Its 16:1 organization reduces channel count without reducing addressable input capacity, and the four address signals allow direct control from a digital bus. Because the distributor records identify on-resistance as either 50 Ω or 80 Ω, engineers should use the datasheet test condition appropriate to their voltage and current. For highest accuracy, use short traces, a quiet ground plane, and a high-impedance downstream stage. Evaluate leakage, charge injection, and switching transients as part of the complete measurement uncertainty.
Рекомендуется
Automated Instrumentation
ADG406BP supports automated instrumentation in which several input channels are selected under software control and measured through a common analog pipeline. The 16 selectable inputs make it practical to scale a system while retaining a simple four-bit addressing interface. The 28-pin PLCC package, identified as 11.51 mm by 11.51 mm, suits compact instrument boards with through-hole assembly. For reliable measurements, isolate address and control paths from the common output, provide local supply bypassing, and establish a defined sequence that allows the downstream filter and ADC to settle after each channel change. The timing margin should be based on the manufacturer's switching-time and settling specifications.
Рекомендуется
Analog Communications Interface
ADG406BP can serve as a switching element in communications and monitoring equipment that must select among multiple analog channels, monitor points, or feedback paths. Four binary address lines allow a small controller to establish the routing state, and the monolithic CMOS architecture matches the high-performance analog multiplexer role documented for the ADG406 family. Use the common output as a carefully controlled analog node and keep RF-adjacent digital activity separated from it. The ±15 V supply arrangement supports bipolar analog systems, but signal amplitude, bandwidth, leakage, and isolation must be checked against the manufacturer datasheet before operation near high-speed or high-level nodes.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для ADG406BP — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | ADG406BPZ |
|---|---|---|
| Package | 28-PLCC (11.51x11.51) | 28-PLCC (11.51x11.51) |
| Brand | Analog Devices | Analog Devices |
| Multiplexer Configuration | 16:1 | 16:1 |
| Number of Channels | 16 channels | 16 channels |
| Number of Switch Circuits | 1 circuit | 1 circuit |
| Supply Voltage | ±15 V dual supply | ±15 V dual supply |
| Address Inputs | 4 binary address inputs | 4 binary address inputs |
| Switch Architecture | Monolithic CMOS LC2MOS | Monolithic CMOS LC2MOS |
| Lifecycle Status | Active | Active |
Ключевые отличия
- Direct 16:1 routing with binary addressing (против ADG406BPZ)
- Single common output simplifies downstream conditioning (против ADG407BPZ)
- PLCC mechanical format supports robust through-hole assembly (против ADG406BPZ)
Заметки по проектированию
Route the common output as a short analog trace directly to the downstream amplifier or converter. Keep the A0 through A3 address lines and their decoder away from this node, use a continuous ground plane where practical, and place the manufacturer's recommended bypass capacitors close to the supply pins. These measures reduce capacitive coupling, switching transients, and ground-potential errors that can appear as channel-dependent measurement error.
Do not assume that the 50 Ω or 80 Ω on-resistance figures from catalog records apply under every supply, signal-voltage, and temperature condition. Use the Analog Devices data-sheet test conditions for the design. Also include off-state leakage and charge injection when calculating errors for high-impedance sources, and allow sufficient settling time after changing A0 through A3 before sampling the common output.
Use a low-noise ±15 V supply arrangement with local high-frequency bypassing and adequate decoupling for the switch's supply-current transients. The exact capacitor values and permitted supply combinations must follow the manufacturer application guidance and electrical tables. If a switch-on transient could disturb an adjacent precision rail, sequence the supplies or place additional filtering where the system error budget requires it.
Although the ADG406BP uses a 28-pin PLCC footprint, do not assign PCB connections from package dimensions alone. Compare every terminal against the manufacturer pin-description table, including power, ground, address, input, and output assignments. Check for unused or internally connected terminals before finalizing artwork, and maintain adequate spacing around supply pins to reduce leakage and soldering defects.
Информация о соответствии
Analog Devices identifies ADG406 as a production LC device, but the retrieved product information does not establish the requested compliance statuses. ADG406BPZ is a lead-free-finish ordering code; lead-free status for ADG406BP and other compliance claims require confirmation from the current manufacturer product documentation.