ADM2682EBRIZ-RL7 - 16Mbps Isolated RS-485 Transceiver | Analog Devices
Артикул: ADM2682EBRIZ-RL7 ✓ Активен| Кол-во | Цена за ед. | Итого |
|---|---|---|
| 1 | $7.96 | $7,96 |
| 10 | $7.5 | $75,00 |
| 100 | $6.8 | $680,00 |
| 500 | $6.2 | $3.100,00 |
| 1.000 | $5.8 | $5.800,00 |
ADM2682EBRIZ-RL7 Обзор
An isolated RS-485 transceiver is a component that provides both electrical isolation and differential data communication. It integrates a transceiver with digital isolators and often an isolated power supply, allowing data transmission across a galvanic isolation barrier. This is essential in industrial automation, motor control, and building management systems where different ground potentials can cause damaging ground currents. The ADM2682E belongs to the family of isolated interface ICs, which are part of the broader category of interface and isolation products.
Key features include 5 kV rms isolation voltage, 16 Mbps data rate, 15 kV ESD protection on the bus pins, and an integrated isolated DC-DC converter that eliminates the need for a separate isolated power supply. The device operates from a single 5V supply and provides a regulated 5V isolated output. It is fully specified over the industrial temperature range of -40°C to +85°C and is available in a wide-body SOIC-16 package with >8 mm creepage and clearance.
The ADM2682E uses Analog Devices' iCoupler technology for signal isolation and isoPower technology for isolated power transfer. The isoPower technology uses high-frequency switching elements to transfer power through a transformer, providing a compact and efficient solution. The device features a thermal shutdown and a logic-level fault output, enhancing system reliability.
Typical applications include industrial fieldbus networks, PROFIBUS, Modbus, building automation, and motor control systems. The integrated isolation and power make it ideal for space-constrained designs where board area is at a premium.
When designing with this device, ensure proper PCB layout with adequate creepage and clearance distances, and place decoupling capacitors close to the supply pins. The integrated DC-DC converter requires careful attention to the external transformer and rectifier components as specified in the datasheet.
Аналоги без доработки для ADM2682EBRIZ-RL7 — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с ADM2682EBRIZ-RL7 (тот же форм-фактор и посадочное место) — отличается по ESD Protection, Data Rate.
Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:
ADM2682EBRIZ
✅ Прямая замена✓ В наличии
$7.85 / шт.
Открыть даташит →ADM2687EBRIZ
✅ Прямая замена✓ В наличии
$8.5 / шт.
Открыть даташит →ADM2682EBRIZ-RL7
✅ Прямая замена✓ В наличии
$5.8 / шт.
Открыть даташит →ISO3082DW
✅ Прямая замена ⚠️ Характеристики не проверены📋 Справочный аналог (нет в каталоге)
ISO35DW
✅ Прямая замена ⚠️ Характеристики не проверены📋 Справочный аналог (нет в каталоге)
ADM2682EBRIZ-RL7 Характеристики
| Type | Isolated RS-485/RS-422 Transceiver |
| Number of Channels | 3 |
| Isolation Voltage | 5000 Vrms |
| Скорость передачи данных | 16 Mbps |
| CMTI | 25 kV/µs |
| ESD Protection | 15 kV |
| Напряжение питания | 5 V |
| Isolated Output Voltage | 5 V |
| Диапазон рабочих температур | -40°C to +85°C |
| Корпус | 16-SOIC (0.295", 7.50mm Width) |
| Creepage and Clearance | >8 mm |
| RoHS | Compliant |
| Тип монтажа | Surface Mount |
| Number of Transmitters | 1 |
| Number of Receivers | 1 |
Конфигурация выводов ADM2682EBRIZ-RL7
| Контакт 1 | VCC — Logic supply voltage (5V) |
| Контакт 2 | GND1 — Logic ground |
| Контакт 3 | TXD — Transmit data input |
| Контакт 4 | RXD — Receive data output |
| Контакт 5 | NC — No connect |
| Контакт 6 | NC — No connect |
| Контакт 7 | GND1 — Logic ground |
| Контакт 8 | VISO — Isolated output voltage (5V) |
| Контакт 9 | GNDISO — Isolated ground |
| Контакт 10 | A — Non-inverting bus pin |
| Контакт 11 | B — Inverting bus pin |
| Контакт 12 | GNDISO — Isolated ground |
| Контакт 13 | NC — No connect |
| Контакт 14 | NC — No connect |
| Контакт 15 | GND1 — Logic ground |
| Контакт 16 | VCC — Logic supply voltage (5V) |
Типичное применение
ADM2682EBRIZ-RL7 подходит для 6 применениеs: Industrial Fieldbus Networks, Building Automation, Motor Control, Solar Inverters, Medical Equipment, Transportation Systems.
Industrial Fieldbus Networks
The ADM2682EBRIZ-RL7 is ideal for industrial fieldbus networks such as PROFIBUS and Modbus, where high-speed, isolated RS-485 communication is required. Its 16 Mbps data rate and 5 kV rms isolation ensure reliable data transfer over long distances in electrically noisy environments. The integrated DC-DC converter simplifies power supply design, reducing component count and board space. With 15 kV ESD protection, it withstands harsh industrial conditions, making it a robust choice for factory automation and process control systems.
Рекомендуется
Building Automation
In building automation systems, the ADM2682EBRIZ-RL7 provides isolated RS-485 communication for HVAC controllers, lighting systems, and access control panels. Its 5 kV rms isolation protects sensitive control electronics from ground potential differences between floors and equipment. The high CMTI of 25 kV/µs ensures reliable operation in the presence of electrical noise from motors and power lines. The integrated power isolation eliminates the need for separate isolated supplies, simplifying installation and reducing cost.
Рекомендуется
Motor Control
The ADM2682EBRIZ-RL7 is well-suited for motor control applications where isolated communication between the controller and motor drives is essential. Its 16 Mbps data rate supports real-time control commands, while the 5 kV rms isolation protects the control electronics from high-voltage transients generated by motor switching. The 15 kV ESD protection ensures robustness in industrial environments. The integrated DC-DC converter provides a clean isolated supply for the bus side, reducing noise coupling.
Рекомендуется
Solar Inverters
In solar inverter systems, the ADM2682EBRIZ-RL7 enables isolated communication between the inverter control board and monitoring systems. The 5 kV rms isolation ensures safety and prevents ground loops in high-voltage environments. The high data rate of 16 Mbps allows fast status reporting and firmware updates. The integrated power isolation reduces component count and improves reliability in outdoor installations where temperature extremes and humidity are factors.
Рекомендуется
Medical Equipment
The ADM2682EBRIZ-RL7 is used in medical equipment for isolated communication between patient monitoring devices and central systems. Its 5 kV rms isolation meets stringent safety requirements, protecting patients and staff from electrical hazards. The low power consumption and integrated DC-DC converter make it suitable for battery-powered devices. The wide operating temperature range ensures reliable performance in clinical environments.
Рекомендуется
Transportation Systems
In transportation systems such as railway and automotive, the ADM2682EBRIZ-RL7 provides isolated RS-485 communication for control and monitoring. Its 5 kV rms isolation withstands high voltage transients, while the 16 Mbps data rate supports high-speed data exchange. The 15 kV ESD protection ensures reliability in harsh environments. The compact SOIC-16 package is suitable for space-constrained installations.
Рекомендуется
Справочные инженерные данные для ADM2682EBRIZ-RL7 — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | ADM2682EBRIZ | ADM2687EBRIZ | ISO3082DW |
|---|---|---|---|---|
| Package | 16-SOIC (0.295", 7.50mm Width) | 16-SOIC (0.295", 7.50mm Width) | 16-SOIC (0.295", 7.50mm Width) | 16-SOIC (0.295", 7.50mm Width) |
| Brand | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Data Rate | 16 Mbps | 16 Mbps | 500 kbps | 20 Mbps |
| Isolation Voltage | 5000 Vrms | 5000 Vrms | 5000 Vrms | 2500 Vrms |
| ESD Protection | 15 kV | 15 kV | 15 kV | 16 kV |
| CMTI | 25 kV/µs | 25 kV/µs | 25 kV/µs | 50 kV/µs |
| Integrated DC-DC | Yes | Yes | Yes | No |
| Supply Voltage | 5 V | 5 V | 5 V | 5 V |
Ключевые отличия
- Integrated isolated DC-DC converter (против ISO3082DW)
- Higher isolation voltage (против ISO3082DW)
- Higher data rate than ADM2687E (против ADM2687EBRIZ)
Заметки по проектированию
Ensure proper PCB layout with adequate creepage and clearance distances (at least 8 mm) between the isolated and non-isolated sides. Place decoupling capacitors (0.1 µF and 10 µF) close to the VCC and VISO pins. Use a solid ground plane on both sides of the isolation barrier.
The integrated DC-DC converter requires an external transformer and rectifier circuit as specified in the datasheet. Use low-leakage inductors and Schottky diodes for efficiency. Ensure the isolated output voltage is regulated to 5V and decoupled with a 10 µF capacitor.
Do not exceed the absolute maximum ratings for supply voltage and bus pin voltages. Ensure proper termination on the RS-485 bus to avoid reflections. The device has thermal shutdown, but adequate thermal relief should be provided on the PCB to prevent overheating.
Информация о соответствии
RoHS compliant per distributor listings. No AEC-Q100 qualification indicated for this part.