ROHM Semiconductor

BD3375KV-CE2 48-Pin Multi-Input Switch Monitor | ROHM

Артикул: BD3375KV-CE2 ✓ Активен
48-pin VQFPC Package
MOQ: 1 |

BD3375KV-CE2 Обзор

The ROHM Semiconductor BD3375KV-CE2 is a highly integrated multi-input switch monitor LSI packaged in a 48-pin VQFPC measuring 7 x 7 mm. The device combines multiple input-switch monitoring functions with a compact surface-mount footprint, making it suitable for systems that require centralized control, status detection, and supervision of several switched inputs. Its 48-pin package provides dedicated connections for the multi-input architecture and supports integration into compact industrial, automotive, and communications equipment.

An interface switch monitor LSI is a specialized form of logic interface IC. It belongs to the broader hierarchy of logic IC, digital interface IC, semiconductor, and system-control electronics. Unlike a simple mechanical switch, this integrated device is intended to detect and manage the condition of multiple inputs within an electronic system. Consolidating those functions can reduce discrete component count, simplify firmware interpretation, and standardize fault handling across several channels.

The BD3375KV-CE2 is identified by ROHM as a multi-input switch monitor LSI and is listed as a specialized interface IC. Its key verified characteristics are the 48-pin package, 7 x 7 mm body size, and multi-input switch-monitoring architecture. The compact package provides a practical advantage in space-constrained designs while offering enough pin count for multi-channel connections, control signals, and associated interface functions.

The device is suited to electronics that require a dedicated monitoring function rather than a general-purpose microcontroller port. In an industrial controller, it can provide structured status information for connected lines. In automotive electronics, it can support centralized supervision of multiple switched inputs while maintaining a compact board footprint. Similar monitoring tasks can be performed in communication equipment, test systems, and automated production machinery.

Because this is a specialized interface device, correct implementation requires the manufacturer pin-description table, electrical limits, recommended operating conditions, and application circuit. Confirm signal thresholds, input tolerances, output logic levels, supply requirements, and unused-pin treatment before releasing a PCB design. The 48-pin package also demands careful escape routing, adequate copper for thermal and electrical performance, and verification of every exposed connection against the current datasheet.

When comparing it with a general-purpose interface IC, choose the BD3375KV-CE2 when integrated multi-input monitoring is the primary requirement. A programmable interface or microcontroller may provide broader software flexibility, but the dedicated monitor can offer a more focused hardware implementation and reduce the amount of host-controller logic needed for channel supervision. The final choice should be based on verified electrical compatibility rather than package similarity alone.

This product page combines the manufacturer identity, package information, sourcing references, engineering guidance, and verified drop-in alternatives into a design-focused record. It also distinguishes confirmed device characteristics from parameters that must be established from the current ROHM datasheet, helping engineers plan sourcing, PCB allocation, and functional verification with fewer assumptions.

Аналоги без доработки для BD3375KV-CE2 — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Для этого товара нет аналогов без доработки.

Запросить аналоги

BD3375KV-CE2 Максимальные параметры и электрические характеристики

Manufacturer ROHM Semiconductor
Device Type Multi-input switch monitor LSI
Категория Specialized interface IC
Корпус 48-pin VQFPC
Package Dimensions 7 x 7 mm
Тип монтажа Surface mount
Количество выводов 48 pins

Руководство по цоколевке BD3375KV-CE2 в корпусе 7 x 7 mm

Цоколевка для BD3375KV-CE2 (корпус 7 x 7 mm). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.

Схема цоколевки корпуса 7 x 7 mm для BD3375KV-CE2

Нет подробных данных о распиновке для BD3375KV-CE2.

Обратитесь к даташиту для полной конфигурации выводов.

Типичное применение

BD3375KV-CE2 подходит для 6 применениеs: Industrial Control Systems, Automotive Electrical Control, Communications Equipment, Test and Measurement Systems, Automated Production Machinery, Embedded Equipment Monitoring.

🏭

Industrial Control Systems

The BD3375KV-CE2 fits industrial controllers that require several switched inputs to be supervised through a dedicated interface LSI. Its confirmed 48-pin VQFPC package and 7 x 7 mm body can conserve board area compared with a discrete implementation using many separate input stages. Engineers can use the monitor to establish a common status path for external equipment, sensors, or subsystem enable lines. Before circuit release, confirm the device's supply voltage, switching thresholds, logic levels, timing, and temperature limits from the current ROHM datasheet. The system should also define how stuck, floating, or invalid input conditions are reported to the controller, because the physical monitoring function must be paired with firmware diagnostics and an appropriate hardware fail-safe strategy.

🚗

Automotive Electrical Control

The BD3375KV-CE2 can support centralized monitoring of multiple switched signals in an automotive electronic control unit when its qualification, electrical limits, and environmental requirements meet the vehicle program. The dedicated 48-pin monitor LSI may simplify repeated input-conditioning logic while preserving a compact 7 x 7 mm board footprint. Automotive implementation requires more than package compatibility: verify the exact ordering code, AEC-Q100 status, temperature grade, transient requirements, and fault-response expectations. Review the manufacturer application guidance for input protection, ground references, unused pins, and startup behavior. Diagnostic requirements should also determine whether simple status monitoring is sufficient or whether the surrounding ECU must perform debounce, plausibility, and redundancy checks.

🌐

Communications Equipment

The BD3375KV-CE2 is applicable to communication equipment that needs centralized supervision of multiple control or status inputs. Its 48-pin VQFPC package supports routing numerous signals in a compact assembly, while the multi-input switch monitor role can provide a consistent hardware interface between external equipment and a host controller. In a communications chassis, reliable input detection can help distinguish connected modules, cable status, reset requests, or peripheral enables. Engineers should verify signal thresholds and logic levels against the actual external interfaces before selecting pull components or protection networks. Keep routing away from high-energy switching nodes and use the manufacturer pin table when defining grounds, supplies, and unused terminals so that the interface remains predictable during startup and fault conditions.

🖥️

Test and Measurement Systems

The BD3375KV-CE2 can be considered for test systems requiring a compact, multi-input status-monitoring block. Instead of assigning each fixture contact to a separate controller input, a dedicated monitor LSI can centralize switch-state detection in a 48-pin 7 x 7 mm package. This approach is useful when the fixture has multiple enable, interlock, or presence signals that must be interpreted consistently. The implementation must still account for contact bounce, threshold levels, isolation, and the timing of the test sequence. Confirm the device's input and output specifications from the current ROHM datasheet, and design the surrounding test harness so that no safety-critical interlock relies on an unvalidated assumption about threshold voltage or switching behavior.

🔧

Automated Production Machinery

The BD3375KV-CE2 fits automated machinery that monitors multiple actuator, sensor, and safety-related status lines through a dedicated interface LSI. Its multi-input architecture can reduce repetitive discrete input circuitry, while the 7 x 7 mm VQFPC package leaves board area for motion-control and communications circuitry. The machine designer should define every monitored line's allowed state, response time, and fault behavior before assigning pins. Verify the device's electrical limits and operating temperature against the machine environment, and use the manufacturer application information to establish suitable input protection. Where machinery safety depends on a monitored signal, pair the status information with the control system's required diagnostic architecture rather than treating routine switch detection as a complete safety function.

🧩

Embedded Equipment Monitoring

The BD3375KV-CE2 can serve embedded equipment that must distinguish several externally switched conditions through a dedicated monitor LSI. The 48-pin package provides a compact way to connect multiple lines to a host processor, and the specialized switch-monitoring function can reduce repetitive port handling. In a consumer or embedded appliance, monitored lines may represent module presence, service-mode entry, external power status, or peripheral enables. Choose the device only after confirming signal polarity, threshold behavior, supply range, and output format. Preserve those interfaces in firmware and define safe defaults for every input. For products exposed to electrostatic discharge, cable transients, or temperature extremes, complete the enclosure, protection, and environmental validation before treating the monitor output as a reliable system-state indicator.

What is the BD3375KV-CE2?
The ROHM Semiconductor BD3375KV-CE2 is a multi-input switch monitor LSI in a 48-pin VQFPC package. It is designed to supervise multiple switched inputs within a compact electronic system. ROHM classifies the device as a specialized interface IC, and distributor product records identify its 7 x 7 mm package size and multi-input monitoring function.
What package does the BD3375KV-CE2 use?
The BD3375KV-CE2 uses a 48-pin VQFPC package measuring 7 x 7 mm. This surface-mount package provides the connection density required for its multi-input architecture while supporting compact PCB layouts. Use the ROHM package drawing and pin-description table for land-pattern dimensions, pin orientation, exposed-pad requirements, and soldering recommendations.
Where can I download the BD3375KV-CE2 datasheet PDF?
The BD3375KV-CE2 datasheet is accessible through the manufacturer-linked datasheet record and the product links listed on this page. Use the current ROHM document to verify the complete pin list, electrical characteristics, recommended application circuit, absolute maximum ratings, and package drawings. Do not assign PCB nets from distributor-category labels alone.
Where can I find the BD3375KV-CE2 pinout?
The authoritative BD3375KV-CE2 pinout is in the ROHM pin-description table and package drawing. The distributor records confirm a 48-pin 7 x 7 mm VQFPC package, but they do not reproduce individual terminal functions. Use the current datasheet to map every power, input, output, control, and no-connect terminal before schematic capture.
What are the key specifications of BD3375KV-CE2 that engineers should know?
The confirmed headline specifications are the 48-pin VQFPC package, 7 x 7 mm body size, and multi-input switch monitor LSI function. The device is categorized as a specialized interface IC for electronic systems requiring centralized supervision of switched inputs. Confirm voltage, thresholds, timing, logic levels, and temperature limits from the current ROHM datasheet before design release.
Is BD3375KV-CE2 suitable for industrial control systems?
The BD3375KV-CE2 can be suitable for industrial control systems that require a dedicated multi-input switch monitor and can operate within its verified electrical limits. Its 48-pin VQFPC package is useful where board space is constrained. Validate industrial temperature requirements, transient immunity, grounding, and fault-response behavior against the application specifications.
Can BD3375KV-CE2 be used in automotive electronics?
The BD3375KV-CE2 may fit an automotive design only after its automotive qualification, temperature grade, electrical limits, and AEC-Q100 status have been confirmed in the current ROHM documentation. Its dedicated multi-input monitoring architecture can simplify channel supervision, but qualification for an automotive program is determined by the specific ordering code and governing requirements.
What can replace the BD3375KV-CE2?
No verified pin-to-pin replacement for the BD3375KV-CE2 is identified in the current cross-reference material. A genuine replacement must match the 48-pin 7 x 7 mm footprint, terminal functions, supply requirements, logic levels, and switching thresholds. Do not substitute a generic interface IC solely because it has a similar package; request a manufacturer-approved cross-reference.
Is BD3375KV-CE2 the same as a general-purpose interface IC?
No, the BD3375KV-CE2 should not be assumed equivalent to a general-purpose interface IC. It is a specialized multi-input switch monitor LSI, while a general-purpose device may expose programmable I/O, serial communication, or logic functions. Functional equivalence depends on the required system behavior, not simply on having an interface in the same package class.
BD3375KV-CE2 versus a microcontroller-based monitor: which is better?
Choose the BD3375KV-CE2 when deterministic multi-input supervision can be implemented with a dedicated LSI, reduced host-controller logic, and a compact 48-pin interface. Choose a microcontroller when software-programmable logic, communications, or broad I/O flexibility is more valuable than a focused hardware monitor. Compare startup behavior, fault handling, update rate, and software effort.
When should I choose BD3375KV-CE2 over a discrete input circuit?
Choose the BD3375KV-CE2 when many switched inputs must be monitored consistently in a compact design. A dedicated monitor LSI can centralize channel status and reduce repetitive discrete input circuitry and firmware handling. Retain a discrete or software approach when channel count is small, thresholds must be highly configurable, or external diagnostics are simpler.
Where to buy BD3375KV-CE2 online?
Use the Request a Quote form on this page to request BD3375KV-CE2 pricing, current stock, lead time, and order confirmation. The manufacturer and manufacturer-part number should remain exactly BD3375KV-CE2 during quotation and purchasing. Confirm authorized sourcing, date codes, and packaging details before releasing a production order.
What is the price of BD3375KV-CE2?
Use the Request a Quote form on this page for the current BD3375KV-CE2 price and volume terms. Pricing can vary with quantity, inventory status, and package configuration, so request a dated quotation for the exact MPN. The quantity pricing shown on this page is generated separately and should be used for the purchasing decision.
What is the lead time for BD3375KV-CE2?
Request the current lead time through the Request a Quote form on this page and state the required quantity and delivery schedule. Lead time can change with inventory and production conditions, so an order acknowledgement is more reliable than a general market estimate. Include any required date-code, quality, and traceability requirements in the request.
Is BD3375KV-CE2 in stock?
Current BD3375KV-CE2 stock status should be confirmed through the Request a Quote form on this page. The exact MPN and required quantity should be included in the request so the supplier can check the relevant packaged inventory. Do not infer production availability from a product-category listing or a general in-stock message.
How should I design the PCB around BD3375KV-CE2?
Place the 48-pin device according to the ROHM package drawing and route each signal with the pin table as the controlling document. Keep sensitive input and reference paths away from fast-switching nodes, provide clean power connections, and verify exposed-pad or thermal-via requirements. Complete signal-integrity and assembly checks before fabrication.
What electrical details must be verified before using BD3375KV-CE2?
Verify supply voltage, input thresholds, output logic levels, timing, current limits, and absolute maximum ratings in the current ROHM datasheet. These values determine whether external pull resistors, level shifters, protection components, or timing margins are required. The confirmed package and multi-input function alone are not sufficient to release a schematic.

Справочные инженерные данные для BD3375KV-CE2 — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the BD3375KV-CE2 when the design needs a dedicated monitor for multiple switched inputs and can accommodate its 48-pin VQFPC footprint. It is particularly attractive where several external status, enable, or presence lines must be supervised in a compact industrial, automotive, communications, test, or embedded-equipment assembly. A microcontroller or programmable interface is preferable when channel thresholds, logic functions, or timing must be changed frequently in software, or when the host already has adequate unused I/O. A discrete input circuit remains simpler for very low channel counts or applications with unusually specialized protection requirements. Before committing to any substitution, verify the complete pin map, supply voltage, input thresholds, logic levels, timing, and qualification status. Package similarity alone does not establish drop-in compatibility.

Сравнение с аналогами

Параметр Этот товар
Brand ROHM Semiconductor
Package 48-pin VQFPC
Package Dimensions 7 x 7 mm
Device Type Multi-input switch monitor LSI
Device Category Specialized interface IC

Ключевые отличия

  • Dedicated multi-input monitoring architecture (против General-purpose interface IC)
  • Compact 48-pin surface-mount implementation (против Discrete multi-input monitoring circuits)
  • Specialized interface positioning (против General-purpose microcontroller)

Заметки по проектированию

Use the current ROHM package drawing and land-pattern recommendations before placing the 48-pin VQFPC device. The confirmed 7 x 7 mm body size does not by itself define solder lands, exposed-pad geometry, or courtyard clearance. Route the multi-input signals according to their sensitivity, keep clock-like or fast-edge control traces separated from monitored inputs, and assign solid ground connectivity. Validate the final stack-up, impedance assumptions, and assembly process before releasing fabrication data.

Confirm input thresholds, tolerances, leakage, and timing from the manufacturer datasheet before selecting pull resistors or protection networks. External cables and long PCB traces can introduce noise, coupling, and slow edges that cause false switch transitions. Keep monitored inputs short where practical, use a defined return path, and place any required filtering close to the device. Validate debounce and fault-detection behavior with worst-case signal levels rather than only nominal logic states.

Do not assign terminal functions from the distributor title alone. Obtain the manufacturer pin-description table and verify all 48 terminals, including power, ground, control, and no-connect positions. Also confirm the exact operating mode, input polarity, initialization sequence, and unused-pin treatment. A mechanically similar interface IC may use the same general package while presenting entirely different logic and timing, so schematic compatibility must be proven pin by pin.

Plan the supply network around the device's verified voltage and current requirements. Place local bypass capacitance at the package power terminals and follow the recommended values and layout in the current manufacturer documentation. Keep switching-regulator nodes and high-current return paths away from monitored inputs and sensitive reference connections. Evaluate startup, shutdown, and fault-state current before sizing the upstream regulator, especially in low-power or battery-powered equipment.

Although this is an interface LSI, its total dissipation depends on supply voltage, I/O loading, switching activity, and ambient conditions. Use the manufacturer power-dissipation and thermal-resistance data for the exact package and board implementation. Provide continuous ground connectivity and follow the recommended copper or via pattern, then verify junction temperature under the highest expected operating load. Do not infer thermal performance from the package dimensions alone.

Информация о соответствии

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

Confirm environmental, material, and automotive compliance from the current ROHM product documentation and the exact ordering code.

Данные проверены: 2026-11-11 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

bd3375kv-ce2 rohm BD3375KV-CE2 datasheet BD3375KV-CE2 datasheet pdf BD3375KV-CE2 pinout BD3375KV-CE2 equivalent BD3375KV-CE2 replacement BD3375KV-CE2 cross reference BD3375KV-CE2 footprint BD3375KV-CE2 schematic BD3375KV-CE2 price BD3375KV-CE2 stock ROHM BD3375KV-CE2 48 VQFPC BD3375KV-CE2 multi-input switch monitor BD3375KV-CE2 7 x 7 mm interface IC

Связанные компоненты & термины

ROHM Semiconductor BD3375KV-CE2 BD3375 multi-input switch monitor LSI interface IC logic IC digital interface IC semiconductor specialized interface switch monitor VQFPC-48 QFN family surface-mount package SMD 7 x 7 mm package multi-channel input monitoring industrial control systems automotive electronics communications equipment test and measurement systems embedded equipment input switching threshold output logic level supply voltage pin description table
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ