Analog Devices

ICL7135CAI+ - 4.5-Digit Dual-Slope ADC | Analog Devices

Артикул: ICL7135CAI+ ✓ Активен
2.0000 V Vdss 28-SSOP, 5.30 mm width Package
MOQ: 1 |

ICL7135CAI+ Обзор

The Analog Devices ICL7135CAI+ is a high-precision, monolithic 4.5-digit dual-slope analog-to-digital converter with a 2.0000 V full-scale capability and accuracy specified to ±1 count in 20,000. It accepts high-impedance differential inputs and provides multiplexed BCD outputs for driving a display in the 28-SSOP package. The converter combines reliable dual-slope conversion with a 0.5-count resolution increment.

A dual-slope ADC is an integrating analog-to-digital converter that measures input voltage by comparing a controlled integration period with a reference-driven de-integration period. This technique belongs to the wider ADC, data-converter, and semiconductor hierarchies. It is especially useful when low-frequency measurements require good noise rejection and predictable behavior with slow-changing sensor signals.

The ICL7135CAI+ provides a 4.5-digit measurement range, a 2.0000 V full-scale capability, and ±1 count in 20,000 accuracy. Its high-impedance differential input structure supports source impedances that would otherwise degrade simple resistive divider measurements. Multiplexed BCD outputs reduce the number of connections required when driving a seven-segment display, while the 28-SSOP format supports compact panel-meter and laboratory-instrument layouts.

The manufacturer describes the ICL7135 as a monolithic converter designed around a dual-slope conversion architecture. Differential input handling is central to its measurement behavior because it permits a sensor signal to be measured relative to a return or reference node. The 4.5-digit result format supports a maximum reading of 19,999 counts, while the stated ±1-count-in-20,000 accuracy establishes the conversion-error target for the product family.

Typical uses include digital panel meters, temperature measurement instruments, laboratory readouts, process monitoring, portable meters, and industrial measurement equipment. The device is particularly appropriate when a regulated reference, controlled input excitation, and a dedicated display interface are available. It is less suitable for high-speed waveform acquisition, communications, or applications requiring many conversions per second.

For implementation, follow the manufacturer pin-description and application tables when assigning the reference, integrator, input, clock, and display signals. Stable reference and input components are central to repeatable dual-slope measurements, while correct grounding and protection are necessary when external sensors connect to the measurement terminals.

This product record combines the official ICL7135 product information with distributor package, ordering, and availability details. It also distinguishes the closely related ICL7135CAI- temperature-grade variant from the ICL7135CMH-D, which uses a different 44-pin package, so engineers can assess replacement options without treating package-incompatible parts as drop-in substitutes.

Аналоги без доработки для ICL7135CAI+ — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

ICL7135CAI-

✅ Прямая замена
📦 28-SSOP
The temperature-grade suffix differs, while the 4.5-digit resolution, 2.0000 V full-scale capability, and ±1 count in 20,000 accuracy remain unchanged at 0% difference in those core conversion specifications.

📋 Справочный аналог (нет в каталоге)

ICL7135CAI+ Максимальные параметры и электрические характеристики

Converter Type Dual-slope A/D converter
Разрешение 4.5 digits, 0.5-count increment
Maximum Reading 19,999 counts
Conversion Accuracy ±1 count in 20,000
Full-Scale Voltage 2.0000 V
Input Configuration High-impedance differential input
Output Format Multiplexed BCD
Display Compatibility 7-segment display driver
Корпус 28-SSOP, 5.30 mm width
Тип монтажа Surface mount
Статус RoHS unknown
REACH Status unknown
AEC-Q100 Qualification unknown

Руководство по цоколевке ICL7135CAI+ в корпусе 28-ssop, 5.30 mm width

Цоколевка для ICL7135CAI+ (корпус 28-ssop, 5.30 mm width). Этот аналоговый компонент имеет выводы входа, выхода и питания. Обратитесь к техническому описанию производителя для конфигураций выводов балансировки нуля, коррекции и разрешения. Идеально подходит для схем обработки сигналов и усилителей.

Схема цоколевки корпуса 28-ssop, 5.30 mm width для ICL7135CAI+

Нет подробных данных о распиновке для ICL7135CAI+.

Обратитесь к даташиту для полной конфигурации выводов.

Типичное применение

ICL7135CAI+ подходит для 6 применениеs: Digital Panel Meters, Temperature Measurement Instruments, Laboratory Digital Readouts, Industrial Process Monitoring, Portable Metering, Precision Resistance Measurement.

📺

Digital Panel Meters

The ICL7135CAI+ fits digital panel meters because its 4.5-digit format, multiplexed BCD outputs, and 19,999-count maximum reading are directly suited to seven-segment display readouts. The converter measures a differential input and presents a stable decimal display without requiring a separate display-control microcontroller. Its ±1 count in 20,000 accuracy gives the instrument a clear precision target, while the 2.0000 V full-scale capability provides a defined conversion range. In a production design, follow the manufacturer reference and display-driver tables so the converter clock, integrator, display multiplexing, and bypass connections follow the intended timing.

🌡️

Temperature Measurement Instruments

The ICL7135CAI+ is appropriate for thermometers and temperature-monitoring instruments that measure slow-changing analog temperatures. Its high-impedance differential input can support a resistive sensor or conditioned bridge signal, while the 4.5-digit resolution and ±1 count in 20,000 accuracy provide useful display precision. A regulated reference and stable sensor excitation remain necessary to preserve the converter’s stated performance. The part is better suited to a readable laboratory or industrial temperature readout than to a thermal waveform system requiring rapid sampling, and the complete measurement chain should be calibrated as a single system.

🧪

Laboratory Digital Readouts

The ICL7135CAI+ can form the measurement core of a laboratory digital readout when the instrument needs a stable 4.5-digit result and a direct display interface. Its dual-slope conversion method, differential input, and multiplexed BCD output simplify a display-oriented instrument without requiring a separate digital interface. The 2.0000 V full-scale range is well suited to normalized sensor outputs, but engineers should account for the complete signal path, including input filtering, reference accuracy, and integrator components. For bench equipment, printed calibration instructions and clearly identified input terminals improve usability alongside the converter’s high measurement precision.

🏭

Industrial Process Monitoring

The ICL7135CAI+ is well matched to industrial process monitoring points where a slowly changing pressure, level, or resistance signal must be shown locally. The differential input reduces sensitivity to shared return-path disturbance, and the 4.5-digit readout can resolve one count in 20,000. Its multiplexed BCD outputs support a direct seven-segment display for panel-mounted equipment. The converter is not the right choice for fast process transients, so the input path should provide sufficient filtering and the design should verify that the measured bandwidth is appropriate. Robust grounding, surge protection, and stable references are especially important in industrial environments.

📱

Portable Metering

The ICL7135CAI+ can support portable, battery-powered meter designs when a low-noise digital readout is more important than conversion speed. Its dual-slope architecture and differential measurement are useful for stable readings from resistive probes, and the multiplexed BCD output directly serves a compact display. The product’s 4.5-digit resolution and ±1 count in 20,000 accuracy help distinguish small measurement changes in field equipment. Designers should use the manufacturer’s power, reference, and clock guidance to manage energy use and start-up behavior, and should add suitable input protection for handheld probes or external sensor connections.

🔧

Precision Resistance Measurement

The ICL7135CAI+ is suitable for a precision ohmmeter or resistance-measurement front end when the test current and reference network are carefully designed. The high-impedance differential input helps accommodate the source impedance of a resistive probe, and the 4.5-digit conversion format is appropriate for laboratory resistance readings. Its stated accuracy must be treated as converter accuracy rather than complete instrument accuracy because lead resistance, excitation drift, contact quality, and reference stability also affect the result. A four-wire arrangement, guarded traces, and calibrated current source can extend practical measurement performance without changing the converter package.

What is the ICL7135CAI+?
The ICL7135CAI+ is a high-precision, monolithic 4.5-digit dual-slope analog-to-digital converter from Analog Devices. According to the manufacturer product page, it combines ±1 count in 20,000 accuracy, a 2.0000 V full-scale capability, high-impedance differential inputs, and multiplexed BCD outputs. The device is intended for precision measurement and display-driven instrumentation using its 28-SSOP package.
What are the key specifications of ICL7135CAI+ that engineers should know?
The ICL7135CAI+ provides 4.5-digit resolution, a 19,999-count maximum reading, ±1 count in 20,000 accuracy, and a 2.0000 V full-scale capability. According to the Analog Devices ICL7135 product page, the converter also uses high-impedance differential inputs and multiplexed BCD outputs. These characteristics position it for low-frequency precision measurement rather than high-speed signal conversion.
Where can I download the ICL7135CAI+ datasheet PDF?
The official ICL7135 datasheet and product resources are available from the Analog Devices product page at analog.com/en/products/icl7135.html. Use the datasheet tab to locate the current PDF and its pin-description, electrical-characteristics, and application tables. The product page is the preferred starting point because it links the current manufacturer documentation and revision for the complete ICL7135 family.
Where can I find the ICL7135CAI+ pinout?
The ICL7135CAI+ pinout is published in the pin-description section of the Analog Devices ICL7135 datasheet. The component uses a 28-SSOP package, so every PCB footprint must provide all 28 device positions and follow the manufacturer’s counter-clockwise numbering. Use the datasheet pin table rather than a distributor thumbnail when assigning the reference, integrator, input, clock, control, and BCD output nets.
What is the difference between ICL7135CAI+ and ICL7135CAI-?
The ICL7135CAI+ and ICL7135CAI- are closely related 4.5-digit ICL7135 converters distinguished primarily by their ordering suffix. The family retains the same 2.0000 V full-scale capability and ±1 count in 20,000 accuracy, so the core conversion specifications show no difference in those values. The ICL7135CAI- can serve as a same-footprint option when its electrical grade and temperature qualification match the target design.
Is ICL7135CMH-D a drop-in replacement for ICL7135CAI+?
No. The ICL7135CMH-D is not a drop-in replacement for the ICL7135CAI+ because it uses a 44-pin QFP package, whereas the ICL7135CAI+ uses a 28-SSOP package. Although both belong to the ICL7135 converter family and perform similar dual-slope measurements, their footprints differ. A PCB redesign, new land pattern, and revised pin assignment are therefore required.
When should I choose ICL7135CAI+ over ICL7135CAI-?
Choose the ICL7135CAI+ when its specified temperature grade and operating limits satisfy the environmental requirements of the instrument. The ICL7135CAI- is appropriate only when its grade is acceptable and the existing design otherwise matches electrically. Both parts belong to the same 4.5-digit, 2.0000 V full-scale ICL7135 family, so final selection should emphasize the exact suffix and operating conditions.
Is ICL7135CAI+ suitable for temperature measurement?
Yes, the ICL7135CAI+ is suitable for slow-changing temperature signals measured with a stable sensor and suitable excitation. Its high-impedance differential inputs are useful for sensor interfaces, while the 4.5-digit resolution and ±1 count in 20,000 accuracy support readable panel-meter results. The measurement accuracy will also depend on sensor characteristics, reference stability, calibration, and thermal compensation.
What can replace ICL7135CAI+ without changing the PCB?
The ICL7135CAI- is the closest established same-package replacement identified for the ICL7135CAI+. It retains the family’s 4.5-digit resolution, 2.0000 V full-scale capability, and ±1 count in 20,000 accuracy while sharing the 28-SSOP format. Confirm the complete pin description and required operating grade before substitution. The ICL7135CMH-D is not a no-redesign option because it uses a 44-pin QFP package.
Is ICL7135CAI+ the same as ICL7135CAI-?
The ICL7135CAI+ is not identical to the ICL7135CAI- because the ordering suffix identifies a different device grade. Their published family characteristics remain consistent: 4.5-digit resolution, a 19,999-count range, a 2.0000 V full-scale capability, and ±1 count in 20,000 accuracy. The decision therefore depends on the exact suffix, temperature requirements, and the manufacturer’s ordering information for each grade.
What is the best Analog Devices equivalent for ICL7135CAI+?
The ICL7135CAI- is the best established Analog Devices same-package equivalent identified for the ICL7135CAI+. It preserves the core 4.5-digit, 2.0000 V full-scale converter performance and uses the same 28-SSOP format. No verified cross-brand part is established as a pin-to-pin substitute, so a functional alternative based only on similar resolution or conversion technology should not be treated as a drop-in replacement.
Where can I buy ICL7135CAI+ online?
Use the Request a Quote form on this page to request ICL7135CAI+ availability, order quantities, and current lead time. The part is listed as an Analog Devices 4.5-digit, 28-SSOP ADC, and the official product page is linked for technical documentation. Requesting a quote keeps the commercial response tied to the exact ICL7135CAI+ suffix, packaging option, and current production position.
What is the price of ICL7135CAI+?
The current commercial price for ICL7135CAI+ is obtained through the Request a Quote form on this page. Pricing can vary with order quantity, shipment date, and package handling, so the form should include your required quantities and delivery schedule. This page keeps the quote tied to the exact Analog Devices MPN instead of presenting an unqualified or potentially mismatched market price.
What is the lead time for ICL7135CAI+?
Request the current ICL7135CAI+ lead time using the Request a Quote form on this page, including your required quantity and target delivery date. Lead time depends on current supplier position and order volume, and the distributor results do not establish a guaranteed factory schedule for every quantity. A quotation response is the appropriate source for a commitment tied to your actual order.
Is ICL7135CAI+ in stock?
Current stock should be confirmed through the Request a Quote form on this page using the exact ICL7135CAI+ MPN and required quantity. Distributor listings indicate that the component is marketed and available for ordering, but they do not establish a stable stock count for your selected quantity. The quote request can confirm allocation, lead time, and the appropriate delivery schedule.

Справочные инженерные данные для ICL7135CAI+ — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the ICL7135CAI+ for a compact, display-oriented instrument requiring a 4.5-digit dual-slope converter, high-impedance differential input, multiplexed BCD output, and a 28-SSOP footprint. The ICL7135CAI- is the close same-package alternative when its ordering grade and operating limits satisfy the design while preserving the core 4.5-digit, 2.0000 V full-scale conversion characteristics. Do not select the ICL7135CMH-D as a drop-in option because its 44-pin QFP package requires a PCB redesign. For designs needing higher throughput, greater channel count, or interface flexibility, evaluate a modern precision ADC such as MCP3424-E/SL or ADS1254E as a redesign rather than as a footprint-compatible replacement. In every case, verify the exact supply, reference, timing, temperature, and pin requirements against the current manufacturer datasheet.

Сравнение с аналогами

Параметр Этот товар ICL7135CAI-
Package 28-SSOP 28-SSOP
Brand Analog Devices Analog Devices
Converter Type Dual-slope A/D converter Dual-slope A/D converter
Resolution 4.5 digits 4.5 digits
Maximum Reading 19,999 counts 19,999 counts
Conversion Accuracy ±1 count in 20,000 ±1 count in 20,000
Full-Scale Voltage 2.0000 V 2.0000 V
Input Configuration High-impedance differential input High-impedance differential input
Output Format Multiplexed BCD Multiplexed BCD

Ключевые отличия

  • Direct multiplexed display interface (против ICL7135CMH-D)
  • Defined precision for display-oriented measurement (против ICL7135CAI-)
  • High-impedance differential measurement (против ICL7135CMH-D)

Заметки по проектированию

Do not substitute the ICL7135CMH-D for the ICL7135CAI+ on an existing board. The former uses a 44-pin QFP package while the target uses a 28-SSOP package, so the land pattern, pin numbering, and PCB outline are incompatible. For a no-redesign replacement, verify the complete ICL7135CAI- ordering information and operating grade against the schematic and assembly drawings.

Assign the reference, integrator, input, clock, control, and multiplexed display nets strictly from the manufacturer pin-description table. The 28-SSOP footprint provides little package spacing, so route sensitive input and reference connections away from display multiplex lines and switching-node areas. Use a stable ground reference for the converter and connect bypass capacitors close to their specified pins to reduce supply disturbance and digital coupling.

Design the reference and supply network around the manufacturer’s application guidance because measurement accuracy depends on stable reference and integrator behavior. Confirm the exact supply limits, capacitor values, and clock requirements from the current datasheet before release. Avoid adding series impedance to the reference path or placing long, high-impedance routes beside the analog input and integrator nets.

Информация о соответствии

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

The manufacturer product page and distributor results do not provide extractable RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations for the exact ICL7135CAI+ orderable suffix.

Данные проверены: 2026-11-04 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

ICL7135CAI+ datasheet ICL7135CAI+ specifications ICL7135CAI+ pinout ICL7135CAI+ datasheet pdf Analog Devices ICL7135CAI+ ICL7135CAI+ 4.5 digit ADC ICL7135CAI+ 28-SSOP pinout ICL7135CAI+ panel meter application ICL7135CAI+ vs ICL7135CAI- ICL7135CAI+ drop-in replacement ICL7135CAI+ price ICL7135CAI+ stock What can replace ICL7135CAI+?

Связанные компоненты & термины

Analog Devices Maxim Integrated ICL7135CAI+ ICL7135CAI- ICL7135CMH-D ICL7116CPL+ MCP3424-E/SL ADS1254E 4.5-digit ADC dual-slope ADC integrating ADC analog-to-digital converter data converter semiconductor high-impedance differential input multiplexed BCD output seven-segment display 19,999-count range 2.0000 V full scale ±1 count in 20,000 accuracy 28-SSOP SSOP package family surface-mount package digital panel meter precision measurement
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ