Intersil

ICL7606MJN CAZ Instrumentation Amplifier | Intersil

Артикул: ICL7606MJN ✗ Снят с производства
18-pin ceramic dual in-line package (CERDIP) Package
MOQ: 1 |

ICL7606MJN Обзор

The Intersil ICL7606MJN is a single-circuit, high-reliability commutating auto-zero instrumentation amplifier housed in an 18-pin ceramic CERDIP package. It combines a CMOS instrumentation-amplifier topology with auto-zeroing to reduce low-frequency offset and drift, making it suitable for precision measurement systems that must detect small differential signals. Its military-temperature construction is intended for applications where temperature stability and long-term reliability are important.

An instrumentation amplifier is a differential amplifier optimized for measuring low-level sensor signals. Its functional hierarchy extends from signal conditioning to amplification, then to analog front-end electronics. The commutating auto-zero, or CAZ, architecture periodically corrects offset voltage and related errors by sampling internal reference conditions. This technique is especially useful in weighing systems, pressure transducers, bridge sensors, biomedical instrumentation, and industrial control equipment where low-frequency drift can obscure the measured signal.

The ICL7606MJN is identified as a one-amplifier CMOS device in an 18-pin CERDIP package. The ceramic dual in-line package provides a durable through-hole mounting format for higher-reliability equipment. Its MIL-temperature classification distinguishes it from ordinary commercial instrumentation amplifiers. The package and circuit arrangement allow it to be evaluated for legacy industrial, aerospace, defense, and scientific-instrument designs where an established part number and controlled package construction are important.

Auto-zeroing reduces the effect of input offset voltage, a major error source when the wanted signal is close to the system's noise floor. In a typical measurement chain, the ICL7606MJN would amplify the differential output of a resistive bridge or transducer, while external resistors establish gain. The amplifier's output can then be routed to an ADC or measurement front end. Correct reference selection, input protection, grounding, and output filtering remain essential because sensor excitation and lead resistance can introduce errors independent of the amplifier's offset behavior.

Typical applications include precision weighing and force measurement, strain-gauge and load-cell signal conditioning, pressure-sensor interfaces, laboratory instrumentation, and high-reliability industrial measurement systems. The device is also appropriate for legacy control equipment requiring a monolithic instrumentation amplifier rather than a discrete resistor network and several operational amplifiers. Existing equipment designs can benefit from the part's established input-output arrangement and package when replacing an equivalent obsolete amplifier.

The primary design consideration is supply and reference behavior. Follow the manufacturer datasheet for the exact supply voltage, common-mode range, gain configuration, quiescent current, offset limits, bandwidth, noise, and compensation requirements. Decoupling should be placed close to the power pins, and sensitive input and feedback routes should be short and shielded from switching nodes and high-current return paths.

This product page combines the component identity, lifecycle position, package information, application guidance, replacement constraints, and engineering design considerations needed to evaluate the ICL7606MJN in precision analog systems. It also highlights why a drop-in substitute must be verified against the complete pinout, electrical limits, gain network, and stability requirements rather than selected from function name alone.

Аналоги без доработки для ICL7606MJN — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Для этого товара нет аналогов без доработки.

Запросить аналоги

ICL7606MJN Максимальные параметры и электрические характеристики

Product Type Commutating auto-zero instrumentation amplifier
Amplifier Count 1 circuit
Architecture CMOS commutating auto-zero (CAZ)
Корпус 18-pin ceramic dual in-line package (CERDIP)
Package Pin Count 18 pins
Тип монтажа Through-hole
Temperature Grade MIL temperature
Reliability Class High reliability
Статус жизненного цикла Obsolete; discontinued by manufacturer

Руководство по цоколевке ICL7606MJN в корпусе 18 pins

Цоколевка для ICL7606MJN (корпус 18 pins). Этот аналоговый компонент имеет выводы входа, выхода и питания. Обратитесь к техническому описанию производителя для конфигураций выводов балансировки нуля, коррекции и разрешения. Идеально подходит для схем обработки сигналов и усилителей.

Схема цоколевки корпуса 18 pins для ICL7606MJN

Нет подробных данных о распиновке для ICL7606MJN.

Обратитесь к даташиту для полной конфигурации выводов.

Типичное применение

ICL7606MJN подходит для 6 применениеs: Load-Cell and Weighing Systems, Strain-Gauge Pressure Transducers, Precision Industrial Instrumentation, Laboratory Measurement Equipment, Aerospace and Defense Test Equipment, Legacy Control and Monitoring Systems.

⚖️

Load-Cell and Weighing Systems

The ICL7606MJN fits precision load-cell measurement because its commutating auto-zero architecture reduces the effect of low-frequency offset voltage in small differential signals. It can amplify a bridge output while the manufacturer's gain and reference configuration determine sensitivity and common-mode behavior. For industrial scales, connect the bridge close to the amplifier, protect the inputs, and keep high-current excitation wiring separate from sensitive signal traces. Confirm excitation magnitude, bridge impedance, input common-mode range, and required bandwidth against the manufacturer datasheet before finalizing the circuit.

🏭

Strain-Gauge Pressure Transducers

The ICL7606MJN is appropriate for strain-gauge pressure transducers where millivolt-level differential outputs must be amplified before conversion. Its auto-zero behavior helps suppress offset drift that would otherwise consume a meaningful portion of the transducer signal. The amplifier should be placed near the sensor or bridge connector, with short guarded inputs and a stable excitation supply. Gain, reference voltage, common-mode headroom, and output swing must be calculated from the actual bridge and sensor ranges before using the obsolete 18-pin CERDIP device in a new pressure instrument.

🏭

Precision Industrial Instrumentation

The ICL7606MJN can serve as the analog front end in legacy industrial instrumentation that measures low-level differential process signals. Its single-package instrumentation-amplifier function reduces the component count associated with a discrete differential amplifier and gain network, while auto-zeroing addresses offset drift. The ceramic CERDIP construction and MIL-temperature identification suit equipment where long service life and established part traceability matter. Layout should isolate the amplifier from relays, motor drives, and switching power converters, and the final operating conditions must remain within the datasheet limits.

🔬

Laboratory Measurement Equipment

The ICL7606MJN is suitable for laboratory instruments that evaluate small differential signals and require reduced offset error. Examples include reference-junction sensing, bridge-based force measurement, and low-level bench sensor interfaces. The CAZ architecture is most valuable when measurements extend into low frequencies and drift would otherwise dominate the result. For a modern laboratory platform, evaluate current instrumentation amplifiers with integrated gain settings and low-power operation; use the ICL7606MJN primarily when preserving an existing calibrated circuit or matching a proven high-reliability configuration.

✈️

Aerospace and Defense Test Equipment

The ICL7606MJN's high-reliability MIL-temperature construction makes it relevant to aerospace, defense, and qualification test equipment where an established ceramic-package instrumentation amplifier is already qualified. It can condition low-level differential outputs from resistive or transducer sensors while auto-zeroing reduces offset-related measurement error. Because the lifecycle status is obsolete, new deployment requires strict configuration control, traceability review, and confirmation that the selected lot meets the program's screening requirements. Pin, solder, temperature, and electrical equivalency must be documented by the responsible engineering authority.

🖥️

Legacy Control and Monitoring Systems

The ICL7606MJN fits legacy control and monitoring systems that retain an 18-pin CERDIP instrumentation-amplifier position on an existing PCB. It can preserve established calibration behavior while providing a single-chip solution for low-level differential sensing. Maintenance teams should confirm the exact pinout, supply arrangement, gain network, and reference voltage before installing a replacement. Modern alternatives may offer lower power, smaller packages, and automated test support, but changing them can require PCB, firmware, and calibration changes that outweigh the benefit in an operating platform.

What is the ICL7606MJN?
The ICL7606MJN is a single-circuit CMOS instrumentation amplifier that uses a commutating auto-zero architecture to reduce low-frequency offset error. According to the manufacturer datasheet, it is a high-reliability MIL-temperature device packaged in an 18-pin ceramic dual in-line package. It is intended for precision differential-signal measurement rather than general-purpose fixed-gain amplification.
What type of package does the ICL7606MJN use?
The ICL7606MJN uses an 18-pin ceramic dual in-line package, identified as CERDIP in the product documentation. The package is a through-hole mounting format, and its ceramic construction is associated with the part's high-reliability and military-temperature positioning. Use the manufacturer pin-description table when assigning PCB holes and confirming signal names.
Is the ICL7606MJN still active?
No. The ICL7606MJN is obsolete and has been discontinued by the manufacturer. Current inventory may still appear through specialist obsolete-component channels, but long-term design continuity is not indicated. For a new production design, obtain written lifecycle confirmation and perform an approved alternate-part review before committing the component to a BOM.
Where can I download the ICL7606MJN datasheet PDF?
The ICL7606MJN datasheet PDF is available through the manufacturer-document mirror listed in the ICL7606MJN datasheet directory and through the manufacturer product links associated with the exact suffix. Use the document for the authoritative pinout, supply limits, common-mode range, gain equations, offset characteristics, noise data, and recommended decoupling. The document mirror identifies the source as Intersil Corporation.
Where can I find the ICL7606MJN pinout?
The ICL7606MJN pinout is shown in the pin-configuration and pin-description sections of the manufacturer datasheet. Because the exact signal names must follow the ceramic 18-pin device, do not infer them from a generic instrumentation-amplifier diagram. When replacing the component, compare every power, input, reference, feedback, and output connection before approving a footprint-compatible substitute.
What is a commutating auto-zero instrumentation amplifier?
A commutating auto-zero instrumentation amplifier periodically measures and corrects its internal offset error by switching between the external signal and an internal reference condition. This technique is useful because input offset voltage and its drift can dominate precision measurements with small differential signals. The ICL7606MJN applies this architecture in a single CMOS instrumentation-amplifier circuit.
What applications are suitable for the ICL7606MJN?
The ICL7606MJN is suitable for bridge sensors, load cells, pressure transducers, strain gauges, laboratory instruments, and other precision measurement systems. Its auto-zero architecture helps reduce low-frequency offset errors, while the 18-pin ceramic package supports high-reliability through-hole designs. Application suitability should also be checked against the required signal bandwidth, supply voltage, and common-mode range.
What can replace the ICL7606MJN?
A replacement must match the ICL7606MJN's exact 18-pin CERDIP footprint, supply limits, common-mode range, gain network, reference behavior, and stability characteristics. The available cross-reference results identify possible substitute categories but do not name a verified pin-to-pin equivalent, so no specific drop-in replacement can be confirmed from the retrieved manufacturer and distributor information. Request an engineering cross-reference review for the target application.
Is the ICL7606MJN the same as a generic instrumentation amplifier?
No. The ICL7606MJN is not interchangeable with a generic instrumentation amplifier based only on its function. It has a specific 18-pin CERDIP pinout, high-reliability construction, MIL-temperature classification, and a commutating auto-zero implementation. A suitable substitute must match those package connections and electrical conditions, including gain-setting and reference behavior.
ICL7606MJN vs modern instrumentation amplifiers: which is better for a new design?
A modern instrumentation amplifier is usually better for a new design because current devices commonly offer more clearly documented supply options, lower offset, faster settling, lower noise, and automated production support. The ICL7606MJN remains relevant when maintaining an existing high-reliability ceramic-package design. The comparison should emphasize offset drift, bandwidth, supply range, package availability, and qualification rather than function alone.
When should I choose the ICL7606MJN over a newer amplifier?
Choose the ICL7606MJN when maintaining an established high-reliability design whose PCB, firmware, calibration procedure, and qualification evidence are already tied to its exact pinout and electrical behavior. Its obsolete lifecycle status makes it less attractive for new platforms. Use a modern amplifier for new development unless exact legacy equivalence has been formally demonstrated and approved.
Is the ICL7606MJN suitable for bridge-sensor measurements?
The ICL7606MJN can be suitable for bridge-sensor measurements when the sensor's excitation, common-mode range, bandwidth, and output level fall within the device's operating limits. Its auto-zero behavior reduces offset-related error in low-level differential measurements. Confirm input protection, bridge excitation stability, gain resistors, reference voltage, and output settling in the manufacturer application guidance.
How should power decoupling be handled for the ICL7606MJN?
Place the recommended bypass capacitors close to the device's supply and ground pins, and route them without long loops through switching or high-current return paths. Follow the manufacturer datasheet for capacitor type, effective capacitance, and permitted supply arrangements. Stable reference and feedback connections are equally important because poor grounding can degrade the offset-correction performance expected from the CAZ architecture.
How do I design the input and feedback network for the ICL7606MJN?
Use the gain-setting method, reference voltage, resistor values, and stability limits specified by the manufacturer datasheet rather than applying values from a different instrumentation amplifier. Keep sensitive input and feedback tracks short, isolated from digital and switching currents, and clean during soldering. Confirm whether the selected operating point requires internal or external gain components before finalizing the schematic.
Where can I request a quote for ICL7606MJN?
Use the Request a Quote form on this product page to request current availability, condition, lead time, and quotation for ICL7606MJN. Because the device is obsolete, traceability and exact suffix matching should be confirmed before purchase. The Request a Quote form is also the appropriate channel for questions about minimum order quantities and obsolete-part handling.

Справочные инженерные данные для ICL7606MJN — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the ICL7606MJN when maintaining an established high-reliability design whose PCB, calibration routine, and qualification record depend on the exact 18-pin CERDIP device. Its commutating auto-zero architecture is useful for low-level differential measurements where offset drift matters, and its through-hole ceramic package simplifies repair within an unchanged platform. For a new design, a current instrumentation amplifier is usually preferable because it generally offers clearer specifications, automated testing, smaller packaging, and stronger availability. Do not select a substitute solely by amplifier type: verify the exact pinout, supply range, common-mode limits, gain network, reference voltage, offset, drift, noise, bandwidth, settling, and lifecycle status. If the ICL7606MJN is required for continuity, obtain traceable obsolete stock and confirm lot-level condition with the manufacturer or an approved supplier.

Сравнение с аналогами

Параметр Этот товар
Product Type Commutating auto-zero instrumentation amplifier
Brand Intersil
Package 18-pin CERDIP
Circuit Count 1 circuit
Architecture CMOS CAZ
Temperature Grade MIL temperature
Lifecycle Status Obsolete
Mounting Type Through-hole

Ключевые отличия

  • Established single-chip CAZ measurement function (против Generic modern instrumentation amplifier)
  • High-reliability ceramic construction (против Commercial plastic-package instrumentation amplifier)
  • Established through-hole service position (против Modern surface-mount instrumentation amplifier)

Заметки по проектированию

Keep the input, feedback, reference, and ground paths short and continuous around the 18-pin CERDIP. Place input protection close to the device pins and route bridge excitation currents separately from sensitive differential traces. A single-ended ground path should be avoided, because shared return copper can convert switching current into an input error that the CAZ loop cannot remove.

Follow the manufacturer datasheet for the allowed supply arrangement, bypass-capacitor values, effective capacitance, and power sequencing. Place ceramic bypass capacitors close to the supply pins with short ground returns. Verify startup behavior, reference voltage, output settling, and supply tolerance before applying the component to a new design, particularly because common-mode and output limits depend on the selected gain and reference configuration.

Do not treat any instrumentation amplifier with the same function as a drop-in replacement. Verify every CERDIP pin, the gain-setting method, internal resistor configuration, reference behavior, supply voltage, common-mode range, offset, noise, bandwidth, and stability. For a legacy repair, compare the replacement against the exact schematic and manufacturer datasheet, then perform gain, offset, noise, and common-mode tests on the assembled board.

The ICL7606MJN is best suited to low-level, low-frequency differential measurements where its auto-zero architecture reduces offset drift. High-frequency performance depends on the complete gain, feedback, and compensation network rather than the device name alone. Keep sensor leads short, use guarded or shielded routing where needed, and verify settling at the actual bandwidth before sampling the output with an ADC.

Информация о соответствии

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

The device is identified as a high-reliability, MIL-temperature, 18-pin CERDIP instrumentation amplifier. Specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the responsible manufacturer or supplier.

Данные проверены: 2026-11-20 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

ICL7606MJN datasheet ICL7606MJN pinout ICL7606MJN datasheet pdf ICL7606MJN equivalent ICL7606MJN replacement ICL7606MJN cross reference ICL7606MJN 18 pin CERDIP Intersil ICL7606MJN ICL7606MJN price ICL7606MJN stock ICL7606MJN instrumentation amplifier ICL7606MJN bridge sensor amplifier ICL7606MJN obsolete replacement

Связанные компоненты & термины

Intersil ICL7606MJN ICL7606 commutating auto-zero amplifier CAZ instrumentation amplifier instrumentation amplifier differential amplifier signal conditioning analog front end semiconductor CMOS MIL temperature high reliability 18-pin CERDIP ceramic dual in-line package through-hole mounting load cell strain gauge pressure transducer bridge sensor input offset voltage low-frequency drift common-mode voltage obsolete component
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ