Texas Instruments

INA125U - Precision Bridge Amplifier, 10V Ref | Texas Instruments

Артикул: INA125U ✓ Активен
В наличии Отправка в течение 1–3 рабочих дней
2.7 V to 36 V Vdss 460 µA Id 16-pin SOIC Package
Контакты для цен
MOQ: 1 |
Цена обновлена: 2026-10-21
Оптовые цены
Кол-во Цена за ед. Итого
1 $0 $0,00
10 $0 $0,00
100 $0 $0,00
500 $0 $0,00
1.000 $0 $0,00
ℹ️ Все цены указаны в USD

INA125U Обзор

The Texas Instruments INA125U is a low-power, high-accuracy instrumentation amplifier with a precision 10V voltage reference, user-selectable gain from 4 to 10,000, and a 16-pin SOIC package. It combines bridge excitation and differential-input amplification on one integrated circuit, making it suitable for strain-gauge, pressure-transducer, and other bridge-sensor signal chains.

An instrumentation amplifier is a specialized differential amplifier designed for sensors whose useful output is small and appears across two input terminals. Its internal architecture provides high input impedance, accurate differential gain, and strong common-mode rejection. The INA125 adds a precision reference output, allowing a bridge circuit to be excited and its output measured relative to a stable midpoint.

The INA125U offers a 2.7V to 36V supply range, low 460µA quiescent current, maximum 250µV input offset voltage, maximum 2µV/°C offset drift, and a sleep mode. A single external resistor sets the gain, while the integrated amplifier can provide 150kHz bandwidth according to the retrieved product data. These features balance precision, power consumption, and measurement speed for portable and industrial instrumentation.

Electrically, the device is intended for bridge outputs and other low-level differential sources. Input common-mode range, reference accuracy, gain error, and maximum input voltage must be checked against the actual bridge excitation and sensor output. The SOIC package also requires careful attention to ground return paths and supply decoupling when low-level signals are measured.

Typical uses include quarter-bridge and full-bridge strain sensors, load-cell front ends, pressure and force measurement, biomedical instrumentation, industrial process controls, and precision data-acquisition systems. The 10V reference can simplify excitation when the sensor and measurement chain require a defined bridge supply.

The most important design consideration is preserving common-mode and differential signal integrity. Place input and reference grounding deliberately, use low-noise supply bypass capacitors, and verify that the selected gain resistor stays within its recommended range. This page combines verified manufacturer and distributor information with practical application guidance and explicit data gaps rather than estimating unprovided specifications.

Аналоги без доработки для INA125U — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с INA125U (тот же форм-фактор и посадочное место) — отличается по Package, Product Type, Quiescent Current, Supply Voltage Range, Mounting Type.

Analog Devices
Package: 8-PDIP
Product Type: Instrumentation amplifier
Supply Voltage Range: 2.7 V to 12 V
Сравнить с INA125U →
Analog Devices
Package: 16-lead LFCSP-VQ (4x4 mm) with exposed pad
Сравнить с INA125U →
Texas Instruments
Package: 16-pin plastic DIP, through-hole
Quiescent Current: 460 µA typical
Mounting Type: Through-hole
Сравнить с INA125U →
Texas Instruments
Package: 8-pin VSSOP (DGK)
Product Type: Precision zero-drift instrumentation amplifier
Quiescent Current: 50 uA typical
Сравнить с INA125U →

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

INA125UA/2K5

✅ Прямая замена
📦 16-pin SOIC
INA125-family ordering variant; exact gain, temperature, and pin-compatibility differences are not quantified in the supplied cross-reference data, so compatibility requires datasheet confirmation

📋 Справочный аналог (нет в каталоге)

INA125P

✅ Прямая замена
Texas Instruments
📦 16-pin SOIC
Instrumentation amplifier with precision voltage reference · 1 circuit · 250 µV · 2 µV/°C · 0.02 V/µs · 150 kHz · 2.7 V to 36 V · 460 µA typical

✓ В наличии

Уточнить цену

Открыть даташит →

INA333AIDGKR

✅ Прямая замена
Texas Instruments
📦 VQFN-16
Precision zero-drift instrumentation amplifier · 3-operational-amplifier · 1 channel · 1.8 V to 5.5 V · 50 uA typical · 10 uV typical · 1 to 1000 · G = 1 + 100 kΩ/RG

✓ В наличии

$0.8373 / шт.

Открыть даташит →

AD623ANZ

✅ Прямая замена
Analog Devices
📦 SOIC-8
Instrumentation amplifier · 1 circuit · 2.7 V to 12 V · 3 V to 12 V · Supported · Rail-to-rail · Single external gain-set resistor · 8-PDIP

✓ В наличии

Уточнить цену

Открыть даташит →

ADG1411YCPZ-REEL7

✅ Прямая замена
Analog Devices
📦 SOIC-8
SPST (4 channels, normally open) · 4 · 1.8 Ω typical · 0.5 Ω max · 1.5 Ω max · ±4.5 V to ±16.5 V · 5 V to 16.5 V · Vss to Vdd

✓ В наличии

$4.65 / шт.

Открыть даташит →

INA125U Максимальные параметры и электрические характеристики

Product Type Instrumentation amplifier with precision voltage reference
Channel Count 1 circuit
Supply Voltage Range 2.7 V to 36 V
Maximum Supply Voltage 36 V
Gain Range 4 V/V to 10,000 V/V
Gain Setting Single external resistor
Ток покоя 460 µA
Input Offset Voltage 250 µV maximum
Input Offset Drift 2 µV/°C maximum
Voltage Reference 10 V
Bandwidth 150 kHz
Noise at 1kHz 38 nV/√Hz typical
Sleep Mode Yes
Корпус 16-pin SOIC
Тип монтажа Surface mount

Руководство по цоколевке INA125U в корпусе 16-pin soic

Цоколевка для INA125U (корпус 16-pin soic). Этот аналоговый компонент имеет выводы входа, выхода и питания. Обратитесь к техническому описанию производителя для конфигураций выводов балансировки нуля, коррекции и разрешения. Идеально подходит для схем обработки сигналов и усилителей.

Схема цоколевки корпуса 16-pin soic для INA125U

Нет подробных данных о распиновке для INA125U.

Обратитесь к даташиту для полной конфигурации выводов.

Типичное применение

INA125U подходит для 6 применениеs: Strain-Gauge Load-Cell Front End, Pressure and Force Transducer Signal Chain, Battery-Powered Portable Measurement, Industrial Process-Control Instrumentation, Biomedical and Diagnostic Instrumentation, Precision Data-Acquisition Systems.

🏭

Strain-Gauge Load-Cell Front End

The INA125U fits a bridge-sensor front end because it combines differential instrumentation amplification with a precision 10V reference and programmable gain from 4 V/V to 10,000 V/V. A quarter-bridge or full-bridge strain gauge can therefore be excited and amplified without relying on a separate reference block. Keep the sensor excitation below its allowable power and verify the amplifier’s common-mode range at the selected bridge excitation. The 250µV maximum offset and 460µA quiescent current are useful for portable measurement systems, while the SOIC package supports compact analog boards.

⚡

Pressure and Force Transducer Signal Chain

The INA125U is appropriate for piezoresistive pressure, force, and displacement transducers that produce a small differential bridge signal. Its 10V reference provides a defined measurement reference, while the broad 4-to-10,000 gain range lets the designer match amplification to the transducer sensitivity and expected full-scale output. The key design trade-off is common-mode headroom: the bridge output must remain inside the device’s permitted input range, and the selected gain must leave sufficient output swing. Offset calibration should be performed after warm-up for high-resolution measurements.

📱

Battery-Powered Portable Measurement

The INA125U’s 460µA quiescent current and sleep mode make it suitable for portable, handheld, or remote measurement systems where continuous instrumentation-amplifier consumption matters. Its integrated bridge excitation and reference can reduce the number of external active components in a compact sensor module. The design must still account for sensor self-heating, battery supply variation, reference noise, and the amplifier’s startup behavior when entering or leaving sleep mode. Use low-leakage switches and careful grounding if the sensor must remain connected while the amplifier is disabled.

🏭

Industrial Process-Control Instrumentation

The INA125U can be used in industrial measurement modules when a bridge sensor is several millivolts above or below a system ground and requires accurate differential amplification. Its precision reference, programmable gain, and low offset support repeatable sensor conditioning, while the 2.7V-to-36V supply range allows operation from low-voltage rails to higher-voltage instrumentation systems. Industrial protection components and isolation may be required around sensor wiring. Validate the common-mode range, transient immunity, grounding strategy, and thermal conditions for the final enclosure and cable environment.

💊

Biomedical and Diagnostic Instrumentation

The INA125U can serve as a low-level analog front end in biomedical and diagnostic instruments when the sensor interface is compatible with its supply, common-mode, and precision characteristics. Its low quiescent current supports power-constrained equipment, and the integrated reference can simplify controlled excitation for suitable resistive bridges. Biomedical designs require careful isolation, patient protection, leakage current analysis, and compliance validation beyond the component datasheet. The amplifier should not be assumed suitable for direct patient-connected use without the complete system safety and application review.

📊

Precision Data-Acquisition Systems

The INA125U is useful in precision data-acquisition systems that need to resolve a differential bridge signal before conversion by an ADC. Its 250µV maximum offset, 2µV/°C maximum offset drift, and programmable gain provide a defined starting point for front-end sensitivity and stability. The 150kHz bandwidth figure should be checked against the selected gain and the required sensor response time. Place the amplifier close to the sensor or bridge input, use a quiet ground plane, and isolate high-current return paths from the differential measurement node.

What is the operating voltage of INA125U?
The INA125U operates from 2.7V to 36V, as stated in the retrieved Texas Instruments product and datasheet results. This wide supply range allows it to be used in low-voltage portable systems as well as higher-voltage industrial instrumentation. The manufacturer describes the INA125 as a low-power, high-accuracy instrumentation amplifier with a precision 10V reference and bridge excitation capability. Confirm the absolute maximum input, output, and common-mode limits for the selected sensor circuit before applying power.
How much gain can the INA125U provide?
The INA125U provides programmable gain from 4 V/V to 10,000 V/V using a single external resistor. This is the gain range identified in the Texas Instruments product-page result and is particularly useful when a strain-gauge or bridge output is only a few millivolts. Higher gain improves sensitivity to small differential signals but can also amplify offset, noise, and errors. Select the gain resistor according to the manufacturer’s gain-setting formula and check the resulting input, output, and bandwidth limits.
Does the INA125U include a precision voltage reference?
Yes. The INA125U includes a precision 10V voltage reference, according to the Texas Instruments description and the retrieved manufacturer datasheet result. That reference can provide a defined excitation or measurement reference for compatible bridge-sensor circuits. The reference voltage must still be checked against the sensor’s allowable excitation range and the amplifier’s input/output limits. Using the integrated reference can simplify system partitioning, but it does not remove the need to validate bridge excitation power and common-mode range.
Where can I download the INA125U datasheet PDF?
The manufacturer datasheet is available at https://www.ti.com/lit/ds/symlink/ina125.pdf. The retrieved search data identifies this document as the instrumentation-amplifier datasheet with precision voltage reference. Use the Texas Instruments product page at https://www.ti.com/product/INA125 for ordering information, quality information, and product updates. The INA125U is the 16-pin SOIC ordering variant identified by DigiKey; confirm the package suffix and pinout against the specific datasheet revision before layout release.
What is the INA125U pinout?
The INA125U is a 16-pin SOIC instrumentation amplifier, but the supplied verified data does not provide the complete numbered pin table. The package and pin names should therefore be taken directly from the Texas Instruments INA125 datasheet rather than inferred from a generic SOIC drawing. The verified distributor listing confirms the 16-SOIC package. Use the manufacturer diagram for exact pin numbering, exposed functions, and any alternate-package differences; this page intentionally does not guess individual pin assignments.
Is the INA125U suitable for a strain-gauge amplifier?
The INA125U is suitable for a strain-gauge or bridge-sensor front end when the bridge excitation and common-mode limits match the device. Its single-resistor gain setting covers 4 V/V to 10,000 V/V, while the integrated precision reference can support bridge-based measurements. The retrieved Texas Instruments description specifically identifies bridge excitation and differential-input amplification. Before selecting it, verify the sensor’s resistance, excitation voltage, output span, common-mode voltage, and required measurement bandwidth against the manufacturer’s electrical characteristics.
How much current does the INA125U consume?
The INA125U has a low quiescent current of 460µA, as highlighted in the retrieved Texas Instruments documentation. Low quiescent current is useful in battery-powered measurement systems where the sensor front end must remain active without consuming excessive standby power. The actual current depends on supply voltage, operating mode, reference use, output loading, and the selected gain. Sleep mode can reduce consumption further when the circuit does not need continuous measurements, but enable-state timing and recovery behavior should be verified in the datasheet.
What is the input offset voltage of INA125U?
The INA125U has a maximum input offset voltage of 250µV, according to the retrieved manufacturer documentation. Offset voltage is important in bridge and strain-gauge systems because it contributes directly to the measured signal error, especially when the sensor differential output is very small. Offset error also interacts with gain: the resulting output error can scale with the selected gain. For high-resolution measurements, use calibration, verify the gain resistor, maintain clean grounding, and account for offset drift and sensor-specific error sources.
What bandwidth does the INA125U provide?
The retrieved product data identifies a 150kHz bandwidth figure for the INA125U. Bandwidth determines how quickly the amplifier can respond to sensor or measurement-system changes and can limit usable gain at higher frequencies. The INA125’s gain is programmable from 4 V/V to 10,000 V/V, so the actual usable bandwidth at the selected gain must be checked in the manufacturer’s frequency-response information. Do not assume the 150kHz figure applies identically to every gain setting without checking the corresponding electrical characteristic.
Can INA125U replace a generic instrumentation amplifier?
The INA125U can be considered only after verifying package, pinout, supply, gain-setting, common-mode range, reference function, offset, bandwidth, and output-swing compatibility. A functional instrumentation amplifier with the same basic purpose is not automatically a drop-in replacement. The verified cross-reference results do not identify a specific alternate MPN with confirmed 16-pin SOIC pin-to-pin compatibility and quantified parameter matching. Engineers should therefore avoid assuming a substitute and should validate the original INA125U datasheet against the proposed replacement.
What is the best replacement for INA125U?
The verified web data does not identify a confirmed drop-in replacement for INA125U. The available cross-reference results point to generic equivalence tools and related INA125 variants, but they do not provide a substitute with verified 16-SOIC pin compatibility and quantified parameter differences. For a production redesign, compare the candidate’s exact pinout, gain equation, bridge excitation capability, precision reference, supply range, common-mode range, offset, drift, noise, and bandwidth. Treat the original INA125U as the reference device until those checks are complete.
Is INA125U in stock and what does it cost?
The verified distributor results identify INA125U as available from DigiKey and Mouser pages, but the supplied data does not include a numeric unit price or a current XAIPART stock quantity. The price therefore cannot be stated reliably here. Use the official Texas Instruments product page or the linked distributor listings to check current price, inventory, and lead time as of 2026-10-22. Commercial status should be confirmed at the distributor checkout or quotation stage because inventory can change independently of manufacturer lifecycle information.
What is the difference between INA125U and INA125UA/2K5?
The retrieved data identifies INA125UA/2K5 as another INA125-related ordering variant, while DigiKey identifies INA125U as a 16-SOIC part. The supplied results do not provide a complete verified parameter table or pin-compatibility statement for INA125UA/2K5, so a definitive drop-in conclusion cannot be made from the available evidence. Compare the exact package, pin names, gain-setting method, reference voltage, electrical limits, and ordering code in the manufacturer documentation before substitution.
When should I choose INA125U over another instrumentation amplifier?
Choose INA125U when your design specifically benefits from integrated bridge excitation, a precision 10V reference, a 4-to-10,000 gain range, and a single-resistor gain setting in a 16-SOIC package. It is a strong fit for bridge-based sensors where preserving a defined excitation and differential measurement path is important. Select another amplifier when its input common-mode range, supply level, offset, noise, bandwidth, package, or reference architecture better matches the actual system; function alone does not establish drop-in compatibility.
How should the INA125U reference and bridge excitation be designed?
The INA125U reference is specified as 10V, so the bridge excitation and sensor safe limits must be checked against that value before connecting it. The integrated reference can simplify the excitation definition, but the sensor’s resistance, power dissipation, allowable excitation voltage, and the amplifier’s common-mode range still determine whether the operating point is valid. Decouple the supply and reference paths according to the manufacturer layout guidance, keep the sensor return close to the input ground, and verify the output swing at the selected gain.
What are the key specifications engineers should know about INA125U?
The key INA125U specifications are a 2.7V-to-36V supply range, programmable gain from 4 V/V to 10,000 V/V, 460µA quiescent current, 250µV maximum input offset voltage, 2µV/°C maximum offset drift, a precision 10V reference, sleep mode, and a 16-pin SOIC package. The retrieved product data also identifies 150kHz bandwidth and 38nV/√Hz typical noise at 1kHz. These figures establish the core design envelope, but common-mode range, gain error, slew rate, and temperature limits remain data-needed in the supplied material.

Справочные инженерные данные для INA125U — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose INA125U when the design is centered on a resistive bridge sensor and needs integrated bridge excitation, a precision 10V reference, and a broad 4-to-10,000 gain range. It is particularly useful when low quiescent current, 250µV maximum offset, and the ability to set gain with one resistor materially simplify the front end. Do not choose it solely because another part is also called an instrumentation amplifier. Verify common-mode range, supply voltage, output swing, gain accuracy, temperature range, and package dimensions. For a proposed substitute, require an exact pinout comparison and recalculate the system’s gain, excitation, offset, noise, bandwidth, and protection requirements. The supplied web data does not establish five confirmed drop-in alternatives, so any alternate candidate requires independent manufacturer-datasheet validation.

Сравнение с аналогами

Параметр Этот товар INA125UA/2K5 INA125P INA333AIDGKR AD623ANZ ADG141
Package 16-pin SOIC 16-pin SOIC family variant; exact package confirmation required 16-pin SOIC; package family indicated by comparison result VQFN-16; not a physical SOIC replacement SOIC-8; not a physical 16-SOIC replacement SOIC-8; not a physical 16-SOIC replacement
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Analog Devices Analog Devices
Special Function Bridge excitation and sleep mode INA125-family variant; exact functions require confirmation INA125-family variant; exact functions require confirmation Instrumentation amplifier; reference and bridge functions require confirmation Instrumentation amplifier; reference function require confirmation Instrumentation amplifier; reference function require confirmation

Ключевые отличия

  • Integrated precision reference and bridge excitation (против AD623ANZ)
  • Broad programmable gain range (против ADG141)
  • Low quiescent current for portable systems (против INA125P)

Заметки по проектированию

The INA125U operates from 2.7V to 36V, but the bridge excitation and sensor safe power must remain within their own limits. Because the integrated reference is specified as 10V, do not assume that a 10V excitation is always safe for every load cell or pressure sensor. Check the sensor resistance and power dissipation before connecting the reference, and provide stable local supply bypassing. Estimated: power dissipated in a resistive bridge is VEXC²/Rbridge; for example, a 350Ω bridge at 10V would dissipate about 0.286W, so the sensor’s permitted dissipation must be verified before applying the reference.

Route the two bridge-sensor differential inputs as a matched, short pair and keep them away from switching-node copper and high-current return paths. Place input, supply, and reference bypass components close to their associated pins. The measured bridge node is sensitive to ground gradients, so a clean analog ground and a controlled star return can be more valuable than an elaborate filter. Verify the SOIC land pattern against the exact package drawing and confirm pin names from the manufacturer datasheet before release.

Do not select the gain resistor or output range from nominal gain alone. First confirm that the bridge output stays within the input common-mode range at the selected excitation, then confirm that the amplified signal does not clip the output. Offset voltage and drift also become more important as gain increases. The verified data supplies a 250µV maximum offset and 2µV/°C maximum drift, but it does not provide gain-error, common-mode-rejection, slew-rate, or complete temperature data; obtain those values before making precision claims.

The listed 150kHz bandwidth is a useful orientation point, but usable bandwidth can change with gain and internal compensation. For dynamic bridge measurements, verify the manufacturer’s frequency-response and settling requirements at the selected gain. Add calibration at system level, maintain consistent sensor and reference grounding, and avoid long unshielded sensor cables where noise or common-mode pickup can dominate the bridge signal. Sleep-mode timing should also be measured because startup delay can affect repeated low-energy measurements.

Информация о соответствии

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

The verified manufacturer and distributor results do not provide explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statements for INA125U. The component is not identified as an automotive-qualified part in the supplied data.

Данные проверены: 2026-10-22 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

INA125U datasheet Texas Instruments INA125U INA125U 16-SOIC instrumentation amplifier INA125U 2.7V to 36V INA125U precision 10V reference INA125U strain gauge amplifier INA125U load cell front end INA125U vs INA125P INA125U drop-in replacement buy INA125U online INA125U price and stock INA125U pinout INA125U low power bridge amplifier INA125U gain resistor formula INA125U common-mode range

Связанные компоненты & термины

Texas Instruments INA125U INA125 instrumentation amplifier differential amplifier bridge excitation precision voltage reference strain gauge load cell pressure transducer common-mode rejection input offset voltage offset drift quiescent current gain SOIC-16 surface mount sleep mode ADC industrial process control biomedical instrumentation RoHS REACH sensor signal chain
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ