IO-LINK-MASTER02-USB Обзор

The Pepperl+Fuchs IO-LINK-MASTER02-USB is a single-channel IO-Link master gateway that bridges a PC USB port to one IO-Link sensor or actuator, supplied as a compact aluminum-housed module measuring 54 x 41 x 24 mm with an M12 A-coded 5-pin IO-Link port and a Mini-B USB 2.0 connector. It enables parameterization, cyclic process-data exchange and diagnostic readout of IO-Link V1.0 / V1.1 devices from a Windows host using the free Pepperl+Fuchs FDT/DTM tools. The unit operates from a standard USB supply (5 V) for low-current sensors, and an external DC power inlet is provided for devices that exceed the USB 200 mA budget, making it a true bench-and-engineering tool.

An IO-Link master is the boundary device in an IO-Link communication system, sitting between the higher-level host (PLC, SCADA, or engineering PC) and the point-to-point IO-Link sensor. Within the hierarchy it belongs to: IO-Link master -> industrial communication gateway -> field-level network component -> industrial automation infrastructure. By exposing the IO-Link stack over USB, this master lets engineers configure and diagnose sensors without standing up a full PLC and PROFINET/EtherNet/IP infrastructure.

Key features include a 5-pin M12 A-coded sensor port per the IEC 61131-9 IO-Link standard, four front-panel status LEDs for power, USB link, IO-Link activity and fault, and an IP20 enclosure rated for cabinet and desktop use. The Mini-B USB 2.0 connector is forward-compatible with any standard USB-A to Mini-B cable shipped in the box, simplifying connection to a laptop. An optional 24 V DC auxiliary supply jack is provided for high-current 4-wire IO-Link devices that cannot be powered from the USB rail alone.

Typical applications include bench-level IO-Link sensor commissioning, firmware updates via FDT/DTM, factory-floor diagnostics on a maintenance laptop, training and demos for IO-Link technology, and pre-installation validation of sensor parameters before deployment on a production IO-Link master. It is widely used in industrial automation labs, sensor R&D, and field service toolkits.

When designing with this master, remember that the USB port provides limited current (typically 200 mA budget); sensors drawing more than that require the external 24 V supply. Always install the matching P+F FDT frame application before connecting sensors to ensure IODD interpreter files load correctly.

Аналоги без доработки для IO-LINK-MASTER02-USB — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

IO-LINK-MASTER01-USB

✅ Прямая замена ⚠️ Характеристики не проверены
📦 Aluminum desktop housing, M12 A-coded 5-pin IO-Link port, USB Mini-B
Same Pepperl+Fuchs USB-IO-Link master family and footprint; older firmware revision but identical electrical interface and software stack

📋 Справочный аналог (нет в каталоге)

IOL-COM/USB

✅ Прямая замена
📦 Desktop IO-Link master with M12 A-coded 5-pin IO-Link port, USB interface
Cross-brand functional equivalent: single-channel USB-to-IO-Link gateway; same M12 A-coded pinout and IO-Link V1.0/V1.1 support; differs in host software (Turck TBEN/DTM vs P+F FDT/DTM)

📋 Справочный аналог (нет в каталоге)

IOLA2US-01101

✅ Прямая замена
📦 SiLink2 Master desktop housing, M12 A-coded IO-Link port, USB
Cross-brand functional equivalent (SICK SiLink2): single-channel USB IO-Link master with M12 5-pin port; uses SOPAS configuration software instead of P+F FDT/DTM; same IO-Link V1.0/V1.1 electrical interface

📋 Справочный аналог (нет в каталоге)

11048016

✅ Прямая замена
📦 USB IO-Link Master desktop housing, M12 A-coded 5-pin, USB
Cross-brand functional equivalent (Baumer USB IO-Link Master): single-channel USB-to-IO-Link gateway with M12 A-coded port and bundled multi-region power supply (EU/KOR/USA/AUS/UK); uses Baumer-specific configuration software

📋 Справочный аналог (нет в каталоге)

USB IO-Link Configuration Tool

✅ Прямая замена
📦 Desktop USB IO-Link master, M12 5-pin plug, USB 2.0
Cross-brand functional equivalent (Telco): single-channel USB IO-Link master with M12 5-pin plug, four status LEDs, optional power pack; optimized for Telco IO-Link sensor line; same electrical pinout

📋 Справочный аналог (нет в каталоге)

TMG USB IO-Link Master V2 - EMC

✅ Прямая замена
📦 Desktop USB IO-Link master housing, M12 connector, USB
Cross-brand functional equivalent (TMG): single-channel USB IO-Link master V2 supporting IO-Link V1.0/V1.1; Pin 2 usable as signal/trigger output for error indication; EMC-focused variant

📋 Справочный аналог (нет в каталоге)

IO-LINK-MASTER02-USB Характеристики (опубликованы производителем)

Product Type IO-Link Master (USB to IO-Link gateway)
Number of IO-Link Channels 1 (single-channel master)
Host Interface USB 2.0 Mini-B plug-in connector
IO-Link Port Connector M12 x 1, 5-pin socket, A-coded
Supported IO-Link Versions V1.0 and V1.1
Supply Voltage - USB (sensor power) 5 V DC via USB
Supply Voltage - Auxiliary (jack) 24 V DC (separate power supply, for high-current sensors)
Auxiliary Power Connector 2.1 mm DC barrel jack
Status Indicators 4 x LED (power, USB, IO-Link activity, fault)
Housing Material Aluminum
Mass approx. 100 g
Dimensions (W x H x D) 41 mm x 24 mm x 54 mm
Degree of Protection IP20 (when properly connected)
Тип монтажа Desktop / portable
Configuration Software Pepperl+Fuchs FDT/DTM tools (free download)
Функция Process data exchange, parameterization, diagnostics for IO-Link devices

Интерфейсы и разъемы IO-LINK-MASTER02-USB

IO-LINK-MASTER02-USB имеет следующие интерфейсы и разъемы, опубликованные производителем: USB, Входная мощность. Цоколевка разъемов расширения, нумерация контактов разъемов и электрические пределы определены в документации производителя.

USB 5 V DC via USB
Входная мощность 24 V DC (separate power supply, for high-current sensors)

Обратитесь к документации производителя для полной распиновки разъёма расширения и нумерации контактов соединителя.

Мощностные и тепловые характеристики

Входная мощность 5 V DC via USB

Параметры входной мощности и тепловые параметры для IO-LINK-MASTER02-USB, опубликованные производителем.

Типичное применение

IO-LINK-MASTER02-USB подходит для 6 применениеs: IO-Link Sensor Commissioning on the Bench, Field Service and Maintenance Diagnostics, IO-Link Training and Demonstration, IO-Link Device Firmware Updates (FDT/DTM), Pre-Installation Sensor Validation, IO-Link Wireless Module Development (R&D).

🔧

IO-Link Sensor Commissioning on the Bench

The IO-LINK-MASTER02-USB is purpose-built for engineering-laptop commissioning of IO-Link V1.0/V1.1 sensors before they are deployed on a production IO-Link master. With its single 5-pin M12 A-coded port and USB 2.0 Mini-B host connection, engineers plug a sensor directly into the M12 socket, launch the free Pepperl+Fuchs FDT/DTM tools, and gain read/write access to all IODD-defined parameters, process data variables and diagnostic events. Compared to deploying a multi-port Ethernet IO-Link master + PLC stack for a single sensor bring-up, the IO-LINK-MASTER02-USB reduces setup time from hours to minutes and avoids allocating an IP address. The 4 status LEDs give instant visual feedback on power, USB link, IO-Link communication and fault state, which speeds up cable and wiring verification.

🏭

Field Service and Maintenance Diagnostics

Maintenance technicians carry the IO-LINK-MASTER02-USB as a portable diagnostic tool to interrogate suspect IO-Link sensors on the plant floor without disconnecting them from the network. Connected to a service laptop over USB and powered from the laptop's 5 V rail, it reads live process data, error codes and historical diagnostic logs from a single sensor via the M12 A-coded port. The auxiliary 24 V DC barrel-jack input allows powering 4-wire actuators when the USB 200 mA budget is insufficient. This makes the IO-LINK-MASTER02-USB a fast triage tool before swapping a sensor or escalating to a full PLC-based investigation, and the IP20 aluminum housing (100 g, 54x41x24 mm) fits a tool bag.

🎧

IO-Link Training and Demonstration

Training centers and sensor vendors use the IO-LINK-MASTER02-USB to teach IO-Link concepts because it isolates the IO-Link protocol from PLC, PROFINET and EtherNet/IP complexity. With one M12 A-coded port, one USB cable and free P+F FDT/DTM software, students see process data, IODD parameter structure and V1.1 data-storage behavior in real time on a single screen. The aluminum housing's compact 54 x 41 x 24 mm footprint and 100 g mass make it easy to ship between training rooms, and the 4 LEDs let instructors point to protocol state changes visually. The optional 24 V auxiliary jack lets the same unit demonstrate both USB-powered and externally-powered sensor topologies.

💡

IO-Link Device Firmware Updates (FDT/DTM)

When a sensor vendor releases new firmware for an IO-Link device, the IO-LINK-MASTER02-USB provides a controlled environment to apply the update via the FDT/DTM workflow. Engineers connect the target sensor, launch the matching IODD interpreter in the P+F FDT frame, and the master carries the firmware image to the device over the C/Q line on Pin 4 of the M12 A-coded port. The auxiliary 24 V supply keeps the sensor powered during the update so the USB rail is not overloaded, and the 4 LEDs give a clear visual cue that IO-Link activity and any fault state are being managed. This avoids having to schedule a full PLC firmware-update window for one device.

🔧

Pre-Installation Sensor Validation

Before mounting a new IO-Link sensor on a machine, quality engineers validate it on the bench with the IO-LINK-MASTER02-USB to confirm parameter ranges, scaling behavior and diagnostic event generation. The 5-pin M12 A-coded IO-Link port and USB 2.0 Mini-B host interface let a laptop act as a virtual PLC, and the P+F FDT/DTM tools surface every IODD-defined parameter. The auxiliary 24 V DC input lets engineers simulate real-world supply conditions rather than the USB 5 V rail, which is critical for sensors whose accuracy depends on a stable 24 V supply. Identifying out-of-box failures at the bench reduces line-stop risk after installation.

📱

IO-Link Wireless Module Development (R&D)

Sensor R&D teams use the IO-LINK-MASTER02-USB as a known-good USB-IO-Link reference while developing wireless IO-Link sensor prototypes. The master's M12 A-coded 5-pin port and standard IEC 61131-9 IO-Link electrical interface provide a reference C/Q waveform on Pin 4 that engineers can probe and compare against their wireless gateway implementation. With V1.0/V1.1 support, the P+F FDT/DTM stack exercises legacy and modern data-storage profiles that the prototype must also implement, and the 4 LEDs are useful for protocol-state bring-up debugging. The 100 g mass and Mini-B USB connector make it easy to embed on a lab bench next to oscilloscope probes.

Сводка рекомендуемых товаров

IO-LINK-MASTER01-USB Same-brand legacy variant for bench commissioning Используется в: IO-Link Sensor Commissioning on the Bench, IO-Link Training and Demonstration, IO-Link Wireless Module Development (R&D) IOL-COM/USB Cross-brand single-channel USB IO-Link master alternative Используется в: IO-Link Sensor Commissioning on the Bench, IO-Link Device Firmware Updates (FDT/DTM) IOLA2US-01101 Cross-brand field-service USB IO-Link master Используется в: Field Service and Maintenance Diagnostics, Pre-Installation Sensor Validation 11048016 Cross-brand Baumer USB IO-Link service tool Используется в: Field Service and Maintenance Diagnostics, Pre-Installation Sensor Validation USB IO-Link Configuration Tool Cross-brand Telco USB IO-Link master for training Используется в: IO-Link Training and Demonstration, IO-Link Wireless Module Development (R&D) TMG USB IO-Link Master V2 - EMC Cross-brand EMC-tested firmware-update master Используется в: IO-Link Device Firmware Updates (FDT/DTM)
What is the IO-LINK-MASTER02-USB used for?
The IO-LINK-MASTER02-USB is a single-channel USB-to-IO-Link master gateway that lets a PC or laptop communicate directly with one IO-Link sensor or actuator. According to the Pepperl+Fuchs datasheet (document 304074), it is intended for sensor parameterization, cyclic process-data readout and diagnostics during commissioning, lab testing and field service - eliminating the need for a full PLC + PROFINET/EtherNet-IP infrastructure during sensor bring-up.
How many IO-Link channels does the IO-LINK-MASTER02-USB support?
The IO-LINK-MASTER02-USB supports exactly one IO-Link channel via a single 5-pin M12 A-coded socket. Per the manufacturer datasheet, it is a single-channel device intended for point-to-point engineering work; if you need to connect up to eight IO-Link devices simultaneously, Pepperl+Fuchs offers the multi-port Ethernet/IP-IO-Link master family (ICE1, ICE2) for that use case.
Where can I buy the IO-LINK-MASTER02-USB and what is the price?
The IO-LINK-MASTER02-USB is in stock and ships same-day from DigiKey (DigiKey part number 22976206) as of 2026-10-20. Typical 1-piece street pricing is around USD 220 with quantity breaks dropping to roughly USD 159 at 100 pieces per distributor listings on Octopart. Authorized stocking distributors include DigiKey, Mouser and specialty automation vendors such as Neff Automation and Applied Industrial Automation.
What is the lead time for the IO-LINK-MASTER02-USB?
Stock lead time for the IO-LINK-MASTER02-USB from major distributors is typically 2-5 business days as of 2026-10-20. DigiKey lists it as 'ships today' for orders placed before the cutoff, while specialty automation distributors may quote 1-2 weeks. Factory-direct orders from Pepperl+Fuchs for large quantities can run 4-6 weeks; check with the distributor at order entry for current lead times.
Can the IO-LINK-MASTER02-USB power an IO-Link sensor directly from USB?
Yes - for low-current IO-Link sensors the IO-LINK-MASTER02-USB supplies 5 V DC over the USB port through the M12 connector. For sensors that draw more than the USB 200 mA budget or that require 24 V actuator power, the unit provides a 2.1 mm auxiliary DC jack for a separate 24 V supply, so the master is not limited to USB-power-only sensors.
IO-LINK-MASTER02-USB vs Turck IOL-COM/USB - which is better for bench testing?
For bench testing a single sensor on Windows, the IO-LINK-MASTER02-USB and the Turck IOL-COM/USB are functionally close, both exposing one IO-Link V1.0/V1.1 channel over USB with vendor FDT/DTM software. Choose the IO-LINK-MASTER02-USB if you standardize on Pepperl+Fuchs IODD libraries and want a 5-pin M12 A-coded port; choose Turck if your sensor fleet is predominantly Turck or you need their TBEN I/O-block ecosystem.
IO-LINK-MASTER02-USB vs Baumer USB IO-Link Master - how do they differ?
Both the IO-LINK-MASTER02-USB and the Baumer USB IO-Link Master (article no. 11048016) provide a single-channel USB-to-IO-Link bridge with M12 connector and free vendor configuration software. They differ in the bundled power supply kit (Baumer ships EU/KOR/USA/AUS/UK adapters) and the IODD interpreter library. Functionally they are drop-in equivalents for bench commissioning - select by sensor brand preference and IODD coverage.
Is the IO-LINK-MASTER02-USB a drop-in replacement for the SICK SiLink2 Master (IOLA2US-01101)?
No - the IO-LINK-MASTER02-USB is not a drop-in replacement for the SICK SiLink2 Master IOLA2US-01101. Both are single-channel USB IO-Link masters, but the SiLink2 ships with SICK-specific SOPAS configuration software and IODD handling, while the IO-LINK-MASTER02-USB uses Pepperl+Fuchs FDT/DTM. The M12 pinout and electrical interface are compatible, but the host software, drivers and IODD parsing differ - so the sensor configuration files are not interchangeable.
When should I choose the IO-LINK-MASTER02-USB over a multi-port Ethernet IO-Link master?
Choose the IO-LINK-MASTER02-USB when you need a portable, laptop-driven engineering tool to commission, parameterize, or diagnose one IO-Link device at a time - typical use cases are sensor bring-up, firmware updates, and field service. Choose a multi-port Ethernet IO-Link master (e.g., Pepperl+Fuchs ICE1/ICE2, Balluff BNI EIP, IFM AL13xx) when you need to run a real-time PLC network with 4-8 IO-Link channels simultaneously on PROFINET, EtherNet/IP or EtherCAT.
Is the IO-LINK-MASTER02-USB suitable for factory-floor production use?
The IO-LINK-MASTER02-USB is rated IP20 (desktop/cabinet) and is intended as an engineering and service tool, not as a permanently installed production-line IO-Link master. Per the datasheet, its primary use is commissioning and diagnostics. For 24/7 production deployment you need an IP67 field-block IO-Link master such as the Pepperl+Fuchs ICE1 series or equivalent.
What is the difference between the IO-LINK-MASTER02-USB and the Telco USB IO-Link Configuration Tool?
The IO-LINK-MASTER02-USB (Pepperl+Fuchs) and the Telco USB IO-Link Configuration Tool are both single-channel USB IO-Link masters with M12 5-pin ports, four status LEDs, and free vendor software. They differ in mechanical housing and vendor-specific IODD libraries - the Pepperl+Fuchs version integrates with P+F FDT/DTM, while Telco's tool is optimized for the Telco sensor line. They are not drop-in equivalents because the host software stack and bundled IODDs differ.
Where can I download the IO-LINK-MASTER02-USB datasheet PDF?
The official IO-LINK-MASTER02-USB datasheet PDF is hosted on Pepperl+Fuchs's webcat at files.pepperl-fuchs.com/webcat/navi/productInfo/pds/304074_eng.pdf (document 304074). A mirrored copy is also available on Alldatasheet (alldatasheet.com/datasheet-pdf/pdf/1548706/PF/IO-LINK-MASTER02-USB.html) and on distributor product pages such as DigiKey 22976206.
Where can I find the pinout for the IO-LINK-MASTER02-USB M12 IO-Link port?
The M12 5-pin A-coded port on the IO-LINK-MASTER02-USB follows the IEC 61131-9 IO-Link standard pinout: Pin 1 = L+ (24 V supply, when auxiliary power is connected), Pin 2 = not connected / DI, Pin 3 = L- (GND), Pin 4 = C/Q (IO-Link data line), Pin 5 = not connected. The full pinout diagram appears in section 'Mechanical specifications' of the manufacturer datasheet 304074.
What are the key specifications of the IO-LINK-MASTER02-USB that engineers should know?
The IO-LINK-MASTER02-USB is a single-channel USB 2.0 Mini-B to IO-Link gateway in a 54 x 41 x 24 mm aluminum IP20 housing, weighing about 100 g, with a 5-pin M12 A-coded IO-Link port, four status LEDs, and optional 24 V auxiliary power via a 2.1 mm DC jack for sensors that exceed the USB current budget. It supports IO-Link V1.0 and V1.1 devices and uses Pepperl+Fuchs FDT/DTM tools for parameterization and diagnostics on Windows hosts.
Does the IO-LINK-MASTER02-USB support IO-Link V1.1 features like data storage and device replacement?
Yes - the IO-LINK-MASTER02-USB supports IO-Link V1.0 and V1.1 per the manufacturer datasheet. V1.1 features such as automatic data-storage upload on parameterization errors and 'plug-and-play' device replacement are visible through the free Pepperl+Fuchs FDT/DTM software stack, as long as the connected IO-Link device itself implements the V1.1 data-storage profile.

Справочные инженерные данные для IO-LINK-MASTER02-USB — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the IO-LINK-MASTER02-USB when you need a Pepperl+Fuchs-supported, single-channel USB-to-IO-Link master for bench commissioning, firmware updates, training or field-service diagnostics on a Windows host. Its 5-pin M12 A-coded port, four status LEDs and auxiliary 24 V DC barrel jack cover the majority of single-sensor engineering tasks without requiring a full PLC infrastructure. Choose the same-brand IO-LINK-MASTER01-USB if you need a legacy firmware variant with identical electrical behavior. Switch to the cross-brand Turck IOL-COM/USB, SICK SiLink2 (IOLA2US-01101), Baumer 11048016, Telco USB IO-Link Configuration Tool or TMG USB IO-Link Master V2 - EMC when your sensor fleet is dominated by a different vendor or when you need their specific configuration-software stack. None of these cross-brand alternatives are firmware-compatible drop-ins - the FDT/DTM, SOPAS, or vendor suite must match the master - so plan for IODD file migration if you swap brands.

Сравнение с аналогами

Параметр Этот товар IO-LINK-MASTER01-USB IOL-COM/USB IOLA2US-01101 11048016 USB IO-Link Configuration Tool
Brand Pepperl+Fuchs Pepperl+Fuchs Turck SICK Baumer Telco Sensors
Package / Form Factor Aluminum desktop housing, 54 x 41 x 24 mm, 100 g Same aluminum desktop form factor Turck desktop housing, comparable footprint SICK SiLink2 desktop housing Baumer desktop housing Telco desktop housing
Number of IO-Link Channels 1 1 1 1 1 1
IO-Link Port Connector M12 x 1, 5-pin, A-coded M12 x 1, 5-pin, A-coded M12 A-coded 5-pin M12 A-coded M12 A-coded 5-pin M12 5-pin plug
Host Interface USB 2.0 Mini-B USB 2.0 Mini-B USB USB USB USB 2.0
IO-Link Version Support V1.0 and V1.1 V1.0 and V1.1 V1.0 / V1.1 V1.0 / V1.1 V1.0 / V1.1 V1.0 / V1.1
Auxiliary Power Input 24 V DC via 2.1 mm barrel jack 24 V DC barrel jack External supply option External supply option Multi-region PSU included (EU/KOR/USA/AUS/UK) Optional power pack
Configuration Software Pepperl+Fuchs FDT/DTM tools (free) P+F FDT/DTM tools Turck TBEN/DTM tools SICK SOPAS Baumer Sensor Suite Telco configuration tool
Status LEDs 4 (power, USB, IO-Link activity, fault) 4 LEDs Multiple LEDs Multiple LEDs Multiple LEDs 4 status LEDs
Degree of Protection IP20 IP20 IP20 IP20 IP20 IP20

Ключевые отличия

  • Bundled vendor FDT/DTM stack with deep IODD library (против IOL-COM/USB (Turck))
  • Auxiliary 24 V DC barrel jack for high-current sensors (против IOLA2US-01101 (SICK SiLink2))
  • Four labeled status LEDs for fast protocol-state debugging (против USB IO-Link Configuration Tool (Telco))
  • Compact 100 g aluminum housing for portable field service (против TMG USB IO-Link Master V2 - EMC)

Заметки по проектированию

The IO-LINK-MASTER02-USB can power a connected IO-Link sensor directly from the USB 5 V rail, but the USB 2.0 specification limits port current to 500 mA total and typical IO-Link sensor budgets on USB masters are 200 mA. For 4-wire IO-Link sensors or any device drawing more than 200 mA, connect a 24 V DC source to the 2.1 mm auxiliary barrel jack - per the P+F datasheet document 304074, the auxiliary input is the only way to deliver full IO-Link L+ current to the sensor's Pin 1.

Do not skip installing the Pepperl+Fuchs FDT frame application before plugging in the master. Without the FDT frame, the IODD interpreter files for individual sensors will not load and the user will see 'no IODD found' errors even when the sensor is electrically connected. Always connect the M12 A-coded cable, then launch the FDT frame, then attach the sensor-specific DTM package.

Although the IO-LINK-MASTER02-USB is a desktop device and not a PCB component, respect the M12 A-coded cable bend radius (typically > 10x cable diameter) and keep the Mini-B USB cable away from sources of EMI such as VFD motor cables - the IO-Link C/Q line on Pin 4 operates at 24 V pulse-modulated data rates up to 230.4 kbps (COM3) and can pick up noise on long parallel cable runs.

The IO-Link C/Q data line on Pin 4 of the M12 A-coded port is a half-duplex 24 V push-pull signal; cable capacitance degrades rise time. Per IEC 61131-9, standard IO-Link cable lengths are limited to 20 m. Do not substitute a generic 5-pin M12 sensor cable for an IO-Link-rated cable - non-IO-Link cables may not meet the 3 nF/m capacitance spec and can cause COM-port fallback to COM1 (4.8 kbps).

Информация о соответствии

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

Compliance statements (RoHS, REACH, lead-free, halogen-free, conflict minerals) were not present in the verified web data and are marked unknown. AEC-Q100 is not applicable for an industrial IO-Link master module. IP20 rating per IEC 60529 is confirmed from the manufacturer datasheet.

Данные проверены: 2026-10-20 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

IO-LINK-MASTER02-USB IO-LINK-MASTER02-USB datasheet Pepperl+Fuchs IO-LINK-MASTER02-USB USB IO-Link master single channel M12 IO-Link USB gateway FDT DTM IO-LINK-MASTER02-USB vs IOL-COM/USB IO-LINK-MASTER02-USB drop-in replacement buy IO-LINK-MASTER02-USB price how to commission IO-Link sensor with USB master USB IO-Link master M12 A-coded pinout IO-Link master for laptop diagnostics Pepperl+Fuchs FDT frame download IO-LINK-MASTER02-USB 24V auxiliary power

Связанные компоненты & термины

Pepperl+Fuchs IO-LINK-MASTER02-USB IO-LINK-MASTER01-USB IOL-COM/USB IOLA2US-01101 SiLink2 Master Baumer USB IO-Link Master 11048016 Telco USB IO-Link Configuration Tool TMG USB IO-Link Master V2 - EMC IO-Link IO-Link master industrial communication gateway IEC 61131-9 FDT/DTM IODD M12 A-coded connector USB 2.0 Mini-B PROFINET EtherNet/IP IP20 aluminum housing 24 V DC sensor supply single-channel IO-Link
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ