Texas Instruments

LM25056PSQ/NOPB - Single-Phase PMBus Power Meter | TI

Артикул: LM25056PSQ/NOPB ✓ Активен
В наличии Отправка в течение 1–3 рабочих дней
3 V to 17 V Vdss 24-WQFN (4 x 5 mm) Package
От $2.1626 USD / шт.
MOQ: 1 |
Цена обновлена: 2026-10-20
Оптовые цены
Кол-во Цена за ед. Итого
1 $2.1626 $2,16
10 $2.1626 $21,63
100 $2.1626 $216,26
500 $2.1626 $1.081,30
1.000 $2.1626 $2.162,60
ℹ️ Все цены указаны в USD

LM25056PSQ/NOPB Обзор

The Texas Instruments LM25056PSQ/NOPB is a single-phase system power measurement IC with a 3 V to 17 V input range, 0.5% metering accuracy, and a 24-WQFN 4 x 5 mm package. It combines analog and digital measurement circuitry with a PMBus-compliant SMBus/I2C interface for reporting power, voltage, current, and temperature in computing and storage systems.

A power measurement IC is a specialized power-management and system-monitoring component that converts real-time electrical operating conditions into digital measurements for a host controller. In the broader hierarchy, it belongs to power-management ICs, interface ICs, energy-metering ICs, and system-power monitors. This hierarchy makes it useful where a backplane power bus must be observed continuously rather than inferred only from system software.

The verified device data identifies a 3 V to 17 V input range and 0.5% accuracy. The PMBus-compliant interface supports digital communication with a system-management host, while continuous reporting of power, voltage, current, and temperature enables telemetry, fault monitoring, load analysis, and thermal management. The 24-WQFN package supports compact placement in single-phase power-system designs.

Technically, the device combines high-performance analog measurement paths with digital signal processing and an SMBus/I2C interface. This combination allows electrical operating data to be transferred to a host while the measurement circuitry handles the physical power bus. The published temperature range is -40°C to +125°C, supporting industrial and system-level applications where the power rail may experience a broad ambient range.

Typical applications include computing and storage blades connected to backplane power buses, server and blade systems, telecom and networking equipment, single-phase power supplies, and embedded system-management controllers. In these systems, the IC provides the measurement layer used to monitor power consumption and operating conditions remotely.

When designing around the LM25056PSQ/NOPB, design the PCB for the 24-WQFN footprint, provide the required input and current-measurement connections, and validate the PMBus address and communication settings in the host controller. Confirm the complete pin mapping and thermal layout against the manufacturer datasheet before releasing a production board. The package is surface mount and uses a WQFN family form factor.

Аналоги без доработки для LM25056PSQ/NOPB — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

LM25056APSQ/NOPB

✅ Прямая замена
📦 24-WQFN (4 x 5 mm)
Same LM25056 family and 24-WQFN package class; exact electrical differences are not quantified in the supplied cross-reference data

📋 Справочный аналог (нет в каталоге)

LM25056PSQ/NOPB Максимальные параметры и электрические характеристики

Product Type Single-phase system power measurement IC
Диапазон входного напряжения 3 V to 17 V
Metering Accuracy 0.5%
Communication Interface PMBus-compliant SMBus/I2C
Measured Quantities Power, voltage, current, and temperature
Диапазон рабочих температур -40°C to +125°C
Корпус 24-WQFN (4 x 5 mm)
Тип монтажа Surface mount
Manufacturer Texas Instruments
Функция Power and operating-condition measurement for system management
Target Application Computing and storage blades connected to backplane power buses
Статус RoHS RoHS3
Availability Signal Active
Carrier Option Custom reel may be available

Руководство по цоколевке LM25056PSQ/NOPB в корпусе 24-wqfn (4 x 5 mm)

Цоколевка для LM25056PSQ/NOPB (корпус 24-wqfn (4 x 5 mm)). Этот силовой прибор имеет выводы затвора, стока и истока. Для неполяризованных корпусов обратитесь к техническому описанию производителя для точной ориентации вывода 1 и деталей посадочного места. Типичные применения включают проектирование источников питания, управление двигателями и коммутацию нагрузки.

Схема цоколевки корпуса 24-wqfn (4 x 5 mm) для LM25056PSQ/NOPB

Нет подробных данных о распиновке для LM25056PSQ/NOPB.

Обратитесь к даташиту для полной конфигурации выводов.

Типичное применение

LM25056PSQ/NOPB подходит для 6 применениеs: Computing Blade Power Telemetry, Storage System Power Monitoring, Backplane Power-Bus Monitoring, Single-Phase Power-Supply Telemetry, Industrial System-Management Controller Interface, Network and Telecom Power Systems.

🖥️

Computing Blade Power Telemetry

The LM25056PSQ/NOPB fits computing blades because it continuously reports power, voltage, current, and temperature to a system-management host through its PMBus-compliant SMBus/I2C interface. Its 3 V to 17 V operating range and 0.5% specified accuracy support real-time monitoring of a single-phase backplane power bus. The device is placed in the power-system signal path rather than as a standalone voltage regulator, allowing the host to track operating conditions without repeatedly probing external rails. The exact current-sense components, thresholds, and PCB layout must follow the TI datasheet.

🖥️

Storage System Power Monitoring

Storage systems benefit from continuous visibility into power, voltage, current, and temperature, particularly when multiple drives or backplane modules share a power bus. LM25056PSQ/NOPB provides the measurement layer and digital reporting interface for a single-phase system. The 0.5% accuracy specification makes it suitable for validated power-accounting designs, while the 3 V to 17 V range covers the stated operating class. Designers should verify the exact current-sense range and power calculation behavior against the current Texas Instruments documentation before layout approval.

🌐

Backplane Power-Bus Monitoring

The LM25056PSQ/NOPB is intended for electrical systems connected to a backplane power bus, where operating data must be available to a management host. Its PMBus-compliant SMBus/I2C interface provides a digital path for real-time power, voltage, current, and temperature reporting. The single-phase architecture supports cost-conscious system monitoring without replacing the measurement function with software estimates. Placement near the power-path sensing network can reduce trace-related measurement error, but the final signal routing and grounding strategy must follow the manufacturer layout guidance.

⚡

Single-Phase Power-Supply Telemetry

LM25056PSQ/NOPB can be used in a single-phase power-supply module when the controller needs measured operating information rather than only set-point data. Reporting power, voltage, current, and temperature enables host-side load tracking, fault detection, and thermal management. The device's stated 3 V to 17 V operating range and 0.5% accuracy provide the core operating limits for system qualification. External current-sensing and filtering components remain application-specific, so engineers should not infer values not shown in the manufacturer datasheet.

🏭

Industrial System-Management Controller Interface

The LM25056PSQ/NOPB is appropriate for industrial equipment that needs remote measurement of power-system operating conditions. The PMBus-compliant SMBus/I2C interface lets a controller acquire power, voltage, current, and temperature data for logging, alarms, or maintenance decisions. The published -40°C to +125°C operating range supports a broad environmental envelope, although the complete electrical and timing limits must still be checked against the TI datasheet. Firmware must also be written for the device's actual command and address configuration.

🌐

Network and Telecom Power Systems

Network and telecom equipment often uses centralized management to monitor power subsystems distributed across racks or line cards. LM25056PSQ/NOPB supplies the measurement function for a single-phase rail and exposes operating information through PMBus-compliant SMBus/I2C communication. Its 0.5% specified accuracy and 3 V to 17 V operating range support systems requiring repeatable power telemetry. For production implementation, verify the current-sense topology, bus capacitance, pull-up requirements, and fault thresholds in the manufacturer documentation.

What is the operating voltage of LM25056PSQ/NOPB?
The LM25056PSQ/NOPB operates from 3 V to 17 V. According to the Texas Instruments product information, it is a single-phase system power measurement IC intended for power buses in computing and storage systems. The verified distributor listing identifies the device as a 24-WQFN 4 x 5 mm package with 0.5% accuracy. Confirm the power-bus working range and all absolute maximum limits in the manufacturer datasheet before final PCB design.
What does LM25056PSQ/NOPB measure?
The LM25056PSQ/NOPB measures power, voltage, current, and temperature and reports the data through a PMBus-compliant SMBus/I2C interface. Texas Instruments describes the device as combining high-performance analog and digital technology for electrical-system monitoring. This makes it suitable for computing and storage blades connected to a backplane power bus. The exact measurement ranges and accuracy for each individual channel are not present in the supplied data.
Where can I download the LM25056PSQ/NOPB datasheet?
The official Texas Instruments product page is https://www.ti.com/product/LM25056, and the search results also identify an LM25056PSQ datasheet mirror on Alldatasheet. Use the TI page as the authoritative source for the current datasheet, ordering information, and support documents. The supplied search result cites an LM25056PSQ datasheet but does not provide enough verified information to reproduce its document number or page count here.
What is the accuracy of LM25056PSQ/NOPB?
The LM25056PSQ/NOPB is specified at 0.5% accuracy by the supplied distributor and manufacturer-related search data. The product is a single-phase energy-metering IC with a 3 V to 17 V operating range and a 24-WQFN 4 x 5 mm package. Because the supplied snippets do not identify whether the 0.5% figure applies to a particular channel, design engineers should verify voltage, current, power, and temperature tolerances individually in the manufacturer datasheet.
Where can I buy LM25056PSQ/NOPB online?
LM25056PSQ/NOPB is listed online by DigiKey, Mouser, LCSC, and other distributors in the supplied search results. LCSC lists a starting price of $2.1626, while distributor pricing and inventory can change. Use the Texas Instruments product page for manufacturer status and approved sourcing information, then compare authorized distributor listings for package, lot traceability, and delivery requirements. Current pricing is referenced as of 2026-10-21.
What is the lead time for LM25056PSQ/NOPB?
The supplied verified data shows active distributor listings but does not provide a guaranteed lead time for LM25056PSQ/NOPB. The TI listing identifies the part as active, and distributor pages indicate that the component can be purchased, but neither source in the supplied data gives a universal lead-time figure. Request a quotation and confirmed date code from the selected authorized distributor before committing the production schedule. Pricing shown is as of 2026-10-21.
Is LM25056PSQ/NOPB in stock?
The supplied results indicate that LM25056PSQ/NOPB is offered through multiple distributors, including DigiKey, Mouser, and LCSC, but they do not provide a reliable, real-time stock quantity for this exact MPN. The TI product page marks the family listing as active. Stock should therefore be checked at the distributor level, including package and carrier options. Do not infer a guaranteed allocation from an active product status alone.
How does LM25056PSQ/NOPB compare with LM25056APSQ/NOPB?
Both LM25056PSQ/NOPB and LM25056APSQ/NOPB belong to the same Texas Instruments LM25056 power-measurement family, but the supplied search data does not provide a complete verified parameter table for the A variant. The part-number comparison result confirms that LM25056APSQ/NOPB is also a PMBus-compliant system power measurement IC. Pin compatibility, accuracy, memory, and threshold behavior must be checked against the current TI datasheets before substitution.
What is the best drop-in replacement for LM25056PSQ/NOPB?
No verified drop-in replacement can be identified from the supplied cross-reference results. The available TI search results confirm LM25056APSQ/NOPB and related family references, but they do not establish the exact package, pin compatibility, and identical electrical behavior required for a drop-in replacement. Treat the family comparison as a starting point and request manufacturer-approved cross-reference data. An unverified substitute could disrupt PMBus communication or power measurement.
Can LM25056APSQ/NOPB replace LM25056PSQ/NOPB?
LM25056APSQ/NOPB may be a related LM25056 family option, but it should not be called a drop-in replacement without a verified pin and parameter comparison. The supplied cross-reference data identifies the A variant as a related PMBus-compliant system power measurement IC, while the target is specified at 3 V to 17 V and 0.5% accuracy. Verify package drawings, exposed-pad connections, current-sense topology, default PMBus address, and measurement limits in both datasheets.
Is LM25056PSQ/NOPB suitable for server and storage power systems?
Yes, LM25056PSQ/NOPB is specifically suited to computing and storage blades connected to backplane power buses. Texas Instruments describes continuous reporting of power, voltage, current, and temperature to a system-management host through the SMBus/I2C interface. Its 3 V to 17 V input range and 0.5% accuracy make it relevant to single-phase power telemetry, provided the sensing network, communication settings, and PCB layout meet the datasheet requirements.
What are the key specifications of LM25056PSQ/NOPB engineers should know?
The key verified specifications are a 3 V to 17 V operating range, 0.5% accuracy, PMBus-compliant SMBus/I2C communication, continuous monitoring of power, voltage, current, and temperature, and a 24-WQFN 4 x 5 mm package. Texas Instruments identifies the device as a single-phase system power measurement IC. The package key is qfn-24 because the supplied package description identifies a 24-pin WQFN, but the complete pin names require the manufacturer datasheet.
What type of interface does LM25056PSQ/NOPB use?
LM25056PSQ/NOPB uses a PMBus-compliant SMBus/I2C interface. The interface allows a system-management host to receive operating measurements such as power, voltage, current, and temperature. According to the Texas Instruments product-page description, the IC continuously supplies real-time data from electrical systems. The supplied material does not specify the bus voltage, timing values, address options, or supported command set, so those details must be taken from the current datasheet.
What is the package of LM25056PSQ/NOPB?
LM25056PSQ/NOPB is supplied in a 24-WQFN package measuring 4 x 5 mm. The verified DigiKey result identifies the device as a 24-WQFN 4 x 5 mm single-phase meter IC. The selected package-diagram key is qfn-24 because it matches the verified 24-pin package family. Exact pin names and exposed-pad details are not included in the supplied snippets and remain pending datasheet verification.
How should LM25056PSQ/NOPB be used in a single-phase power bus?
Use LM25056PSQ/NOPB as the measurement and telemetry device for a single-phase power bus, with analog sensing connected to the power system and a host controller communicating through PMBus-compliant SMBus/I2C. The device is intended to report power, voltage, current, and temperature for computing and storage blades. Exact resistor, capacitor, current-sense, layout, and thermal requirements are not present in the supplied data and should be implemented from the TI datasheet and reference design.
What can replace LM25056PSQ/NOPB?
A verified drop-in replacement cannot be confirmed from the supplied evidence. LM25056APSQ/NOPB is identified as a related same-family part, but the available results do not prove that it matches the target's 24-WQFN footprint, pin mapping, electrical behavior, and default communication configuration. For production use, obtain an official TI cross-reference or compare the complete datasheets before naming a replacement. Functional similarity alone is not sufficient for a PCB-level substitution.

Справочные инженерные данные для LM25056PSQ/NOPB — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose LM25056PSQ/NOPB when designing a single-phase computing, storage, backplane, telecom, or industrial power-monitoring system that needs a PMBus-compliant SMBus/I2C path for power, voltage, current, and temperature data. The verified 3 V to 17 V operating range and 0.5% accuracy make it suitable for systems where the measurement network and operating limits match those specifications. LM25056APSQ/NOPB is a related same-family candidate, but it should be selected only after its datasheet confirms identical package pinout, current-sense requirements, address configuration, command behavior, and electrical limits. No unrelated power-monitor IC should be treated as a drop-in replacement merely because it uses SMBus. For a new design, prefer the target when its measurement architecture matches the power bus; for an existing board, perform a complete pin- and threshold-level review before substitution.

Сравнение с аналогами

Параметр Этот товар LM25056APSQ/NOPB
Package 24-WQFN (4 x 5 mm) 24-WQFN package class; exact package verification required
Brand Texas Instruments Texas Instruments
Product Type Single-phase system power measurement IC System power measurement IC
Communication Interface PMBus-compliant SMBus/I2C PMBus-compliant SMBus/I2C
Measured Quantities Power, voltage, current, and temperature Power, voltage, current, and temperature

Ключевые отличия

  • Dedicated single-phase power measurement role (против LM25056APSQ/NOPB)
  • Digital operating-condition telemetry (против LM25056APSQ/NOPB)
  • Compact system-monitoring integration (против LM25056APSQ/NOPB)

Заметки по проектированию

Route the power-measurement sensing connections as short and controlled as practical, following the manufacturer layout recommendation. Keep the analog measurement section physically separated from high-current switching paths and noisy digital return currents. Because the supplied snippets do not provide the complete pinout or reference layout, the production design must be checked against the current TI datasheet before copper, placement, and test-point decisions are released.

The PMBus-compliant SMBus/I2C interface must be laid out as a controlled communication network. Use the required pull-up arrangement, keep the bus routing short where practical, and ensure the host controller supports the device's configured address and command set. The supplied data confirms the interface type but does not specify voltage, timing, address options, or capacitance limits; obtain those values from the manufacturer datasheet before final schematic release.

The LM25056PSQ/NOPB is intended to measure a power system, not to replace the power-conversion stage. Validate the sensing network, input limits, grounding, and measurement range against the 3 V to 17 V operating class and the actual bus load. Do not infer current-range or dissipation values from the 0.5% accuracy statement alone; use the datasheet's absolute maximum ratings and recommended operating circuit.

Although the verified data identifies a 24-WQFN 4 x 5 mm package and a -40°C to +125°C temperature range, it does not provide a thermal-resistance value or power dissipation curve. Confirm the exposed-pad connection, copper area, airflow assumptions, and maximum junction temperature from the manufacturer documentation. Production thermal validation should include the highest expected ambient temperature and the worst-case measurement and communication activity.

Информация о соответствии

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

The supplied DiGi Electronics result states RoHS3. REACH, lead-free status, halogen-free status, AEC-Q100 qualification, and conflict-minerals status are not provided in the verified data and therefore remain unknown.

Данные проверены: 2026-10-21 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

LM25056PSQ/NOPB LM25056PSQ/NOPB datasheet Texas Instruments LM25056 LM25056 24-WQFN 4 x 5 mm LM25056 3 V to 17 V power measurement IC LM25056 PMBus SMBus I2C power telemetry LM25056 single phase energy metering IC LM25056PSQ/NOPB vs LM25056APSQ/NOPB LM25056PSQ/NOPB drop-in replacement LM25056PSQ/NOPB price LM25056PSQ/NOPB pinout 24-WQFN system power measurement IC PMBus single-phase power monitoring IC LM25056 power voltage current temperature measurement where to buy LM25056PSQ/NOPB

Связанные компоненты & термины

Texas Instruments LM25056PSQ/NOPB LM25056APSQ/NOPB system power measurement IC single-phase energy metering power-management IC system-monitoring IC PMBus SMBus I2C power telemetry power measurement voltage measurement current measurement temperature measurement backplane power bus computing blade storage system telecom power system industrial power monitoring 24-WQFN WQFN package family surface-mount package RoHS3 0.5% accuracy
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ