MAX358CPE+ - 8:1 Fault-Protected Analog Multiplexer | Maxim
Артикул: MAX358CPE+ ✓ АктивенMAX358CPE+ Обзор
An analog multiplexer is an analog switch that connects one of several input channels to a common output, allowing a controller to sample or control multiple signals with fewer external pins. The MAX358 family uses series N-channel, P-channel, and N-channel transistor structures to improve fault protection. This topology is intended to limit damage when an input exceeds the normal supply range, making the device useful in instrumentation and test systems where accidental signal overvoltage is possible.
The MAX358CPE+ provides one 8:1 single-ended multiplexer, an on-resistance of 1.8 kOhm, and operation across positive and negative supply rails. The 16-pin DIP package supports conventional through-hole PCB assembly. The manufacturer identifies the MAX358 as a production device and describes it as a fault-protected analog multiplexer. Its principal benefits are channel consolidation, selectable signal routing, and added protection against excessive input voltage.
The MAX358 is useful in automated test equipment, data acquisition systems, industrial measurement systems, instrument switching, and laboratory signal selection. A system can route one of eight external inputs to a shared amplifier, converter, or measurement channel while keeping the physical interface compact. For designs requiring differential signal routing, the MAX359 is the more appropriate family member, whereas MAX358 is intended for single-ended signals.
The principal design consideration is ensuring that the selected channel, supply rails, signal levels, and fault conditions remain within the device's specified operating envelope. Input and control traces should be arranged to minimize coupling between adjacent channels, and the multiplexing system should include appropriate protection when signals can exceed the expected range. The manufacturer datasheet should be used for the complete electrical characteristics, pin configuration, and application limits.
This page consolidates the device identity, manufacturer resource, distributor references, technical use cases, and design considerations for engineers evaluating the MAX358CPE+. It distinguishes the single-ended MAX358 from differential multiplexers and emphasizes the importance of matching package, channel architecture, voltage range, and fault-protection requirements during replacement.
Аналоги без доработки для MAX358CPE+ — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с MAX358CPE+ (тот же форм-фактор и посадочное место) — отличается по Package, Mounting Type, Fault Protection, Multiplexer Configuration.
MAX358CPE
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
MAX328EPE+
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
MAX358CPE+ Характеристики
| Multiplexer Configuration | 8:1 single-ended |
| Number of Channels | 8 channels |
| On-State Resistance | 1.8 kOhm |
| Supply Voltage Range | +/-4.5 V to +/-18 V |
| Корпус | 16-pin DIP |
| Тип монтажа | Through-hole |
| Signal Type | Single-ended analog |
| Fault Protection | Fault-protected analog multiplexer |
| Power-Off Isolation | Supported |
| Рабочая температура | 0 C to +75 C |
| Manufacturer | Maxim Integrated |
| Product Status | Production |
Руководство по цоколевке MAX358CPE+ в корпусе 16-pin dip
Цоколевка для MAX358CPE+ (корпус 16-pin dip). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.
Нет подробных данных о распиновке для MAX358CPE+.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
MAX358CPE+ подходит для 6 применениеs: Automated Test Equipment, Data Acquisition Systems, Industrial Sensor Interface, Instrument Signal Routing, Battery-Powered Monitoring, Communication Interface Protection.
Automated Test Equipment
The MAX358CPE+ is well suited to automated test equipment that connects one of eight single-ended test points to a shared measurement amplifier or converter. Its 8:1 architecture reduces the number of external routing connections while preserving selectable access to multiple sources. The 1.8 kOhm on-state resistance introduces signal loading that must be included in the input-impedance budget of the selected channel. Fault protection adds value in systems where a test channel may accidentally encounter an excessive voltage, while power-off isolation helps prevent unwanted signal coupling during inactive states. Engineers should verify channel switching timing, control logic levels, source impedance, and the complete operating-voltage limits in the manufacturer datasheet.
Рекомендуется
Data Acquisition Systems
A data acquisition system can use the MAX358CPE+ to route eight single-ended sensor or voltage inputs to one common processing channel. This arrangement is useful when channel count is higher than the available converter inputs and each channel has a similar impedance range. The 8:1 single-ended topology simplifies addressing logic while the 1.8 kOhm on resistance imposes a fixed load that can affect high-impedance sensors. The designer should add suitable input buffering, maintain consistent grounding, and confirm that source settling occurs before conversion. Fault protection and power-off isolation are especially useful when externally connected signals can exceed the expected measurement range or when inactive channels share the same wiring environment.
Рекомендуется
Industrial Sensor Interface
The MAX358CPE+ can consolidate several single-ended industrial sensor outputs before they reach a shared amplifier or control input. Its fault-protected topology is advantageous when field wiring can present transients or accidental overvoltage, while the ±4.5 V to ±18 V dual-supply range supports higher-level analog systems. Because the on-state resistance is 1.8 kOhm, sensors with high source impedance may require a buffer at the selected channel. Layout should keep the analog trace short, provide a low-impedance ground reference, and separate address and enable lines from sensitive inputs. The system integrator should validate the complete signal range, fault condition, and operating temperature against the production datasheet.
Рекомендуется
Instrument Signal Routing
Instrument signal routing is a direct use for the MAX358CPE+ because laboratory and bench instruments often need to select among several external inputs without duplicating complete front-end circuits. One of eight single-ended sources can be connected to a common measurement or display path, reducing connector count and board complexity. The 1.8 kOhm series resistance should be checked against the source impedance and amplifier input requirements, particularly for high-impedance probes. Control traces and analog inputs should be routed away from fast digital signals to minimize switching crosstalk. The fault-protected architecture provides additional resilience, but normal input amplitudes must remain within the device's specified operating conditions and all unused external inputs should be managed appropriately.
Рекомендуется
Battery-Powered Monitoring
In a battery-powered monitoring system, the MAX358CPE+ can select among multiple analog sensing inputs while keeping the external interface compact. The device's single-ended 8:1 arrangement is appropriate when voltage dividers, thermistors, or other grounded sensors must be routed to one amplifier or ADC. The ±4.5 V to ±18 V supply requirement means the power architecture must supply both rails and maintain sufficient headroom across temperature and battery condition. Because the multiplexer itself consumes power, the designer should compare its operating current with the overall sleep-mode budget. External signal conditioning, input filtering, and high-impedance buffering may be needed to preserve measurement accuracy during channel transitions.
Рекомендуется
Communication Interface Protection
The MAX358CPE+ can serve as a protected analog routing element in communication equipment that accepts externally wired, single-ended signals. Its fault-protected structure is useful when an external line presents a voltage beyond the expected signal range, and power-off isolation reduces unintended coupling when the device is unpowered. The 8:1 configuration allows several auxiliary or status inputs to share a protected interface path. However, the 1.8 kOhm on resistance is relatively high for high-speed signal paths, so bandwidth and attenuation must be evaluated before using the mux for communications. Designers should also place appropriate protection networks at exposed connectors and ensure that control inputs remain within valid logic levels during power transitions.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для MAX358CPE+ — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | MAX358CPE | MAX328EPE+ |
|---|---|---|---|
| Package | 16-pin DIP | 16-pin DIP - same | 16-pin DIP - same |
| Brand | Maxim Integrated | Maxim Integrated - same | Maxim Integrated - same |
| Multiplexer Configuration | 8:1 single-ended | 8:1 single-ended | 8:1 single-ended fault-protected multiplexer |
| Fault Protection | Yes | Yes | Yes |
Ключевые отличия
- Direct MAX358 ordering-match option (против MAX358CPE)
- Single-ended channel concentration (против MAX328EPE+)
- Production family positioning (против MAX358CPE)
Заметки по проектированию
Treat the 1.8 kOhm on-state resistance as part of the source-load network. Calculate the resulting attenuation with the source impedance, the selected channel's impedance, and the downstream amplifier input impedance. High-impedance probes may require a buffer immediately after the multiplexer. Also include capacitance and bandwidth requirements when determining whether a discrete multiplexer is appropriate for a fast signal.
Place the multiplexer close to the connector or sensor interface being routed to minimize trace capacitance and susceptibility to injected noise. Keep channel traces away from high-current switching nodes, and connect the device ground pins to a low-impedance ground plane using short paths. Address and enable traces should be controlled-driver compatible and physically separated from sensitive analog traces where practical.
Do not confuse MAX358CPE+ with MAX359CPE+: the former is an 8-channel single-ended mux, while the latter is a four-channel differential mux. Also avoid treating the MAX358CWE+ surface-mount variant as a physical substitute for a 16-pin DIP board. Verify enable logic, supply polarity, and all pin names against the manufacturer pin table before assembling the PCB.
Estimated: with a 36 V total positive-to-negative supply span and 1.8 kOhm on resistance, the theoretical conducting-path dissipation is 0.72 W if the full rail span appears across the channel. Real signal-path dissipation is lower because the drop equals the switched signal voltage. Use actual maximum signal amplitude and load current for the thermal budget, and provide normal copper heat dissipation around the through-hole package.
Информация о соответствии
No explicit environmental-compliance statement was identified for the exact MAX358CPE+ ordering code. AEC-Q100 is not applicable because the device is a commercial analog interface IC rather than an automotive-qualified product; confirm current compliance documentation with the manufacturer before use in restricted designs.