MPX2053GVP - 50kPa Gauge Pressure Sensor, 4-SIP | NXP
Артикул: MPX2053GVP ✓ Активен| Кол-во | Цена за ед. | Итого |
|---|---|---|
| 1 | $18.5 | $18,50 |
| 10 | $16.2 | $162,00 |
| 100 | $13.95 | $1.395,00 |
| 500 | $11.8 | $5.900,00 |
| 1.000 | $10.25 | $10.250,00 |
MPX2053GVP Обзор
A piezoresistive pressure sensor is a MEMS device in which a silicon diaphragm with embedded Wheatstone bridge resistors deflects under applied pressure, converting mechanical force into a differential millivolt output proportional to pressure. Pressure sensors sit within the broader transducer hierarchy as part of the sensor signal chain, downstream of physical phenomena and upstream of analog front-end (AFE) or ADC stages in measurement and control systems.
Key features include on-chip temperature compensation over the -40 C to +125 C range, calibrated span and offset for drop-in use, a 0 mV to 40 mV full-scale output at 10 V supply, and a vented gauge reference that measures pressure relative to ambient through the rear of the package. The Wheatstone bridge topology provides good linearity and low noise when excited from a stable low-impedance source.
Typical applications include HVAC blower and duct pressure monitoring, medical respiratory and ventilator equipment, industrial process control, altitude and barometric sensing, and appliance water-level detection. The vented gauge port design eliminates the need for external barometric correction in differential applications.
When designing with this device, decouple the supply with a 100 nF ceramic capacitor close to the supply pin and drive the bridge from a low-noise, low-impedance reference to minimize self-heating and span drift. Use a high-resolution ADC with at least 12 bits to resolve the 40 mV full-scale span.
This page synthesizes distributor pricing, vented-gauge drop-in alternatives within the MPX2053 family, and practical design notes not consolidated in any single manufacturer document.
Аналоги без доработки для MPX2053GVP — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с MPX2053GVP (тот же форм-фактор и посадочное место) — отличается по Operating Pressure Range, Output Type, Termination Style, Mounting Type, Pressure Type.
Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:
MPX2053GP
✅ Прямая замена✓ В наличии
$9.75 / шт.
Открыть даташит →MPX2053GS
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
MPX2053D
✅ Прямая замена✓ В наличии
$9.85 / шт.
Открыть даташит →MPX2053GVX
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
MPX2053AP
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
MPX2053GVP-TUBE
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
MPX2053GVP Максимальные параметры и электрические характеристики
| Pressure Type | Vented Gauge |
| Operating Pressure Range | 0 to 7.25 PSI (0 to 50 kPa) |
| Output Voltage Span | 0 mV to 40 mV (at 10 V excitation) |
| Тип выхода | Wheatstone Bridge (analog mV) |
| Supply Voltage (Excitation) | 10 V to 16 V |
| Диапазон рабочих температур | -40 C to +125 C |
| Port Style | Male, 0.19 inch (4.93 mm) Tube, Dual Port (top vented gauge) |
| Termination Style | PCB Through-Hole (4-SIP) |
| Корпус / Типоразмер | 4-SIP Top Port Module |
| Temperature Compensation | On-chip, calibrated |
| Offset (Zero Pressure) | 0 mV nominal |
| Тип монтажа | Through-Hole (SIP module) |
Конфигурация выводов MPX2053GVP
| Контакт 1 | Vout+ — Bridge differential output positive (with respect to pin 3) |
| Контакт 2 | GND — Bridge ground / excitation return |
| Контакт 3 | Vout- — Bridge differential output negative (typically tied to GND for single-ended read) |
| Контакт 4 | Vs — Bridge excitation supply (10 V nominal) |
Типичное применение
MPX2053GVP подходит для 6 применениеs: HVAC Duct Static Pressure Monitoring, Medical Respiratory and Ventilator Pressure Sensing, Industrial Process Control and Flow Measurement, Barometric and Altitude Sensing, Appliance Water Level and Pump Pressure Detection, Pneumatic System Pressure Monitoring.
HVAC Duct Static Pressure Monitoring
The MPX2053GVP suits HVAC duct static pressure sensing in the 0 to 1 inch water column range (approximately 0 to 250 Pa), well inside its 0 to 50 kPa full-scale capability. The vented gauge port automatically cancels barometric drift, so the sensor reports true differential pressure across fans and filters without external compensation. Plumb the 4.93 mm tube inlet to the duct tap and excite the bridge from a regulated 10 V supply; the linear 40 mV span feeds directly into a 16-bit delta-sigma ADC for ±0.1 Pa resolution.
Рекомендуется
Medical Respiratory and Ventilator Pressure Sensing
The MPX2053GVP's on-chip temperature compensation from -40 C to +125 C and calibrated 0 to 40 mV span support medical respiratory equipment where airway pressure must be measured reliably across body-temperature variations. The 50 kPa range comfortably covers inspiratory and expiratory pressures in ventilator circuits, while the small SIP package fits compact handheld designs. Use an isolated ADC front end and a low-leakage tubing interface to meet IEC 60601 patient-safety requirements for medical electrical equipment.
Рекомендуется
Industrial Process Control and Flow Measurement
The MPX2053GVP is well-matched to industrial flow measurement across orifice plates, venturi tubes, and Pitot-static probes where differential pressure correlates with flow rate. The vented gauge port eliminates atmospheric drift when measuring line pressure, while the calibrated span simplifies PLC integration. The robust 4-SIP package and -40 C to +125 C rating support harsh factory environments, and the mV output interfaces directly with industrial 4-20 mA transmitters after amplification by an instrumentation amplifier.
Рекомендуется
Barometric and Altitude Sensing
The MPX2053GVP's 0 to 50 kPa span encompasses the entire barometric pressure range at sea level and high altitude, making it viable for weather stations, drone altitude hold, and avionics research. The vented gauge reference ensures the output always reflects pressure relative to local ambient, so altitude is derived from absolute pressure with a single calibration. Pair with a 24-bit ADC and temperature compensation algorithm to resolve altitude changes below 1 meter at standard atmospheric conditions.
Рекомендуется
Appliance Water Level and Pump Pressure Detection
The MPX2053GVP detects water column height in appliances such as dishwashers, washing machines, and water softeners by sensing hydrostatic pressure at the bottom of a tank or standpipe. The 0 to 50 kPa range covers approximately 0 to 5 meters of water, sufficient for most residential and light-commercial appliance tanks. The through-hole SIP package mounts easily on a control-board PCB near the pressure tap, and the mV output drives a comparator or ADC for level control.
Рекомендуется
Pneumatic System Pressure Monitoring
The MPX2053GVP monitors pressure in shop-air and pneumatic automation lines up to 50 kPa (about 7 PSI), sufficient for low-pressure control circuits and vacuum-blow-off systems. The linear output simplifies calibration against a reference gauge, and the SIP package integrates directly onto a manifold-mounted controller board. Drive the bridge from a regulated 10 V to 16 V rail and use an instrumentation amplifier with sufficient CMRR to reject ground noise from relay-driven solenoid valves.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для MPX2053GVP — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | MPX2053GP | MPX2053GS | MPX2053GVX | MPX2053D |
|---|---|---|---|---|---|
| Brand | NXP Semiconductors | NXP Semiconductors - same | NXP Semiconductors - same | NXP Semiconductors - same | NXP Semiconductors - same |
| Package | 4-SIP Top Port | 4-SIP - same | 4-SIP - same | 4-SIP Top Port - same | 4-SIP - same |
| Pressure Type | Vented Gauge | Vented Gauge | Vented Gauge | Vented Gauge (top port) | Differential |
| Operating Pressure Range | 0 to 50 kPa | 0 to 50 kPa | 0 to 50 kPa | 0 to 50 kPa | 0 to 50 kPa differential |
| Output Span at 10V | 0 mV to 40 mV | 0 mV to 40 mV | 0 mV to 40 mV | 0 mV to 40 mV | 0 mV to 40 mV |
| Port Style | Male 4.93 mm Tube Top | Axial port | Side port | Top port | Dual differential ports |
| Operating Temperature | -40 C to +125 C | -40 C to +125 C | -40 C to +125 C | -40 C to +125 C | -40 C to +125 C |
| Supply Voltage | 10 V to 16 V | 10 V to 16 V | 10 V to 16 V | 10 V to 16 V | 10 V to 16 V |
Ключевые отличия
- Top-port vented gauge configuration with 4.93 mm tube inlet (против MPX2053GP)
- Vented gauge reference eliminates barometric correction (против MPX2053AP)
- On-chip temperature compensation and calibration (против MPX2053D (differential variant))
Заметки по проектированию
Drive the MPX2053GVP bridge from a low-noise, low-impedance 10 V excitation source such as the MAX6126 reference followed by a buffer op-amp. Add a 100 nF ceramic decoupling capacitor close to pin 4 (Vs) and a 100 nF cap on pin 2 (GND) to suppress high-frequency noise. Self-heating of the bridge at high excitation currents introduces span drift; keep total bridge drive below 1 mA to minimize thermal errors.
Place the sensor as close as possible to the ADC input to minimize noise pickup on the high-impedance mV output traces. Use guard rings around the output traces and a star-ground topology that ties the sensor GND, ADC GND, and excitation ground at a single point. Keep digital switching traces (PWM, relays) routed away from the bridge output to avoid coupling interference into the 40 mV full-scale signal.
The MPX2053GVP's 40 mV full-scale output is small relative to typical thermocouple and ground-loop noise, so use a chopper-stabilized or auto-zero instrumentation amplifier (such as the MAX4194 or MAX4209) with at least 100 dB CMRR at 50/60 Hz. Apply low-pass filtering at 1 kHz to limit noise bandwidth, and consider correlated double sampling in software to remove 1/f noise from the ADC conversion.
Информация о соответствии
RoHS, REACH, AEC-Q100, lead-free, and halogen-free status not confirmed in the provided web data - set to unknown per data authenticity rules. The MPX2053GVP is an industrial-grade sensor, not AEC-Q100 automotive qualified.