NVIDIA

MSN3700-CS2FC - 32x100GbE Spectrum-2 Switch | NVIDIA Mellanox

Артикул: MSN3700-CS2FC ✓ Активен
В наличии Отправка в течение 1–3 рабочих дней
100-264 V AC Vdss 1GbE to 100GbE (splittable to 128 x 10/25GbE) Speed
От $1 USD / шт.
MOQ: 1 |
Цена обновлена: 2026-10-18
Оптовые цены
Кол-во Цена за ед. Итого
1 $1 $1,00
ℹ️ Все цены указаны в USD

MSN3700-CS2FC Обзор

The NVIDIA Mellanox MSN3700-CS2FC is a 1U rack-mountable data center Ethernet switch built on the Spectrum-2 ASIC, delivering 32x 100GbE QSFP28 ports with 6.4 Tbps switching capacity, a forwarding rate of 4.76 Bpps, and a cut-through latency of 425 ns in a short-depth chassis with P2C (back-to-front) airflow and dual AC power supplies.

A data center spine/leaf switch is the core building block of cloud-scale layer-2 and layer-3 network fabrics. In the network hierarchy, a spine switch aggregates leaf switches to form non-blocking Clos topologies; the Spectrum-2 platform belongs to the broader family of Open Ethernet switching systems designed for software-defined networking (SDN) and runs the ONIE-installed Cumulus Linux network operating system on an x86 management CPU.

Key features include fully splittable QSFP28 ports supporting speeds from 1GbE to 100GbE, expandable to 128x 10/25GbE ports with splitter cables, dual redundant AC power supplies rated 100-264 V, and L3 managed switching with advanced SDN capabilities. The Spectrum-2 ASIC provides consistent low latency and deep buffering for East-West traffic.

The MSN3700-CS2FC combines the Spectrum-2 silicon with an open ecosystem: ONIE boot loader, Cumulus Linux, and standard x86 CPUs allow full automation through DevOps tooling. Back-to-front (P2C) airflow suits hot-aisle exhaust data center layouts, and the standard-depth chassis fits shallow racks common in colocation facilities.

Typical applications include cloud-scale leaf/spine fabrics, hyperconverged storage networks, big data and analytics clusters, and high-density 25GbE server access using breakout cables. It is also deployed as a super-spine aggregation switch in web-scale IT.

Design consideration: verify airflow direction at ordering time; the -CS2FC (P2C/back-to-front) variant must not be mixed with front-to-back (C2P) units in the same rack without ducting planning.

This page synthesizes distributor pricing, drop-in platform alternatives, and practical deployment notes not found in the manufacturer datasheet, with pricing verified as of 2026-10-19.

Аналоги без доработки для MSN3700-CS2FC — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с MSN3700-CS2FC (тот же форм-фактор и посадочное место) — отличается по Airflow, Power Supplies, Form Factor, Management, ASIC.

NVIDIA
Airflow: Back-to-front (as listed by Insight/PartsSource for -CB2FC)
Power Supplies: 2 x AC (redundant)
Form Factor: 1U, rack-mountable, standard (short) depth
Сравнить с MSN3700-CS2FC →
NVIDIA
Airflow: P2C (port-to-cloud, front-to-back)
Power Supplies: 2 x AC (redundant)
Form Factor: 1U rack-mount, standard depth
Сравнить с MSN3700-CS2FC →
NVIDIA
Airflow: C2P (front-to-back)
Power Supplies: 2 x AC PSU (redundant)
Form Factor: 1U rack-mountable, standard depth
Сравнить с MSN3700-CS2FC →
NVIDIA
Airflow: C2P (Connector-to-Power)
Power Supplies: 2 x AC, redundant
Form Factor: 1U rack-mountable, standard depth
Сравнить с MSN3700-CS2FC →
NVIDIA
Airflow: P2C (port-to-connector)
Power Supplies: 2x AC PSU (redundant, hot-swappable)
Form Factor: 1U rack-mount
Сравнить с MSN3700-CS2FC →
NVIDIA
Airflow: C2P (connector-to-panel)
Power Supplies: 2 x AC (redundant, hot-swappable)
Form Factor: 1U rack-mount, standard depth
Сравнить с MSN3700-CS2FC →
NVIDIA
Airflow: Connector-to-Power (C2P)
Power Supplies: 2 x AC (redundant)
Form Factor: 1U rack-mount, standard depth
Сравнить с MSN3700-CS2FC →

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

MSN3700-CS2RC

✅ Прямая замена ⚠️ Характеристики не проверены
NVIDIA
📦 1U rack-mount chassis
NVIDIA Spectrum SN3000 (SN3700C) · NVIDIA Spectrum-2 · 32 x 100GbE QSFP28 · 1GbE to 100GbE per SN3000 series · 12.8 Tb/s · 8.33 Bpps · 425 ns · Layer 3 managed

✓ В наличии

Уточнить цену

Открыть даташит →

920-9N201-00F7-0C0

✅ Прямая замена
📦 1U rack-mount chassis
same hardware under newer NVIDIA OPN numbering instead of Mellanox-style OPN; per BrightStar Systems the two part numbers identify exactly the same unit

📋 Справочный аналог (нет в каталоге)

SSE-SN3700-CS2FC

✅ Прямая замена
📦 1U rack-mount chassis
Supermicro OEM version of the same Spectrum-2 32x100G platform, 6.4Tb/s, 1U; now EOL at Supermicro

📋 Справочный аналог (нет в каталоге)

MSN3700-VS2FC

✅ Прямая замена
NVIDIA
📦 1U rack-mount chassis
NVIDIA Spectrum SN3000 (SN3700) · NVIDIA Spectrum-2 · 32 QSFP56 ports · Up to 200GbE per port (series supports 1GbE to 400GbE) · 12.8 Tb/s · 1U rack-mount · Standard depth · 2x AC PSU (redundant, hot-swappable)

✓ В наличии

$9100 / шт.

Открыть даташит →

SSE-SN3700-CS2RC

✅ Прямая замена
📦 1U rack-mount chassis
Supermicro OEM of the same platform with reverse airflow; EOL, sold via secondary market

📋 Справочный аналог (нет в каталоге)

MSN3700-CS2FC Максимальные параметры и электрические характеристики

Product Type 1U managed L3 Ethernet switch
ASIC Mellanox Spectrum-2
Port Configuration 32 x 100GbE QSFP28
Switching Capacity 6.4 Tbps
Forwarding Rate 4.76 Bpps
Latency 425 ns
Port Speed Range 1GbE to 100GbE (splittable to 128 x 10/25GbE)
Form Factor 1U rack-mountable
Management L3 managed, x86 CPU, ONIE, Cumulus Linux
Airflow P2C (back-to-front)
Power Supplies 2 x AC, redundant (100-264 V)
Диапазон входного напряжения 100-264 V AC
Depth Standard depth
Mounting Rack-mountable (rail kit included)
Series SN3000 (Spectrum-2)

Руководство по цоколевке MSN3700-CS2FC в корпусе standard

Цоколевка для MSN3700-CS2FC (корпус standard). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.

Схема цоколевки корпуса standard для MSN3700-CS2FC

Нет подробных данных о распиновке для MSN3700-CS2FC.

Обратитесь к даташиту для полной конфигурации выводов.

Типичное применение

MSN3700-CS2FC подходит для 6 применениеs: Cloud-Scale Leaf/Spine Fabrics, Hyperconverged Storage Networks, Big Data and Analytics Clusters, High-Density 25GbE Server Access, Super-Spine Aggregation, SDN and Network Automation Deployments.

🌐

Cloud-Scale Leaf/Spine Fabrics

The MSN3700-CS2FC is purpose-built as a spine switch in Clos topologies for cloud and web-scale data centers. Its 32 x 100GbE QSFP28 uplinks with 6.4 Tbps of non-blocking capacity allow a single spine to connect up to 32 leaf switches at 100G, or more at lower speeds, while the 425 ns cut-through latency keeps fabric hop latency predictable. Because every port is splittable down to 10/25GbE, the same chassis can serve as a high-density leaf connecting 128 servers at 25G via breakout cables. Cumulus Linux on the x86 CPU enables full fabric automation through standard DevOps tooling, and the dual redundant AC supplies maintain uptime during PSU failures. Standard-depth 1U design fits dense colocation racks with P2C back-to-front airflow matching hot-aisle exhaust layouts.

🖥️

Hyperconverged Storage Networks

Hyperconverged infrastructure (HCI) clusters generate heavy East-West replication and rebalancing traffic that demands high bisection bandwidth and consistent latency. The MSN3700-CS2FC addresses this with 6.4 Tbps of switching capacity and a 4.76 Bpps forwarding rate on the Spectrum-2 ASIC, ensuring storage replication traffic does not queue behind compute traffic in shallow-buffer designs. Its 100GbE ports can directly attach NVMe-oF storage arrays or split to 25GbE for host connectivity, supporting flexible blocking ratios. Deep buffering and consistent low latency protect iSCSI, NVMe/TCP, and distributed-storage protocols from microbursts. Cumulus Linux telemetry provides visibility into congestion, and dual AC power supplies plus front/serviceable airflow options make it deployable in both new and legacy facility power layouts with 100-264 V input ranges.

📊

Big Data and Analytics Clusters

Distributed analytics frameworks such as Spark, Hadoop, and AI training jobs are dominated by all-to-all shuffle traffic that stresses spine fabrics. The MSN3700-CS2FC provides the 6.4 Tbps bisection bandwidth and 4.76 Bpps packet rate needed to keep shuffle phases from stalling job completion, while the 425 ns per-hop latency of the Spectrum-2 ASIC minimizes RPC tail latency across the cluster. Ports spanning 1GbE to 100GbE let operators connect management, compute, and high-speed data interfaces on one fabric with varied oversubscription. The Open Ethernet software stack (ONIE plus Cumulus Linux) supports telemetry-driven traffic engineering and integration with container networking. Standard-depth 1U chassis and P2C airflow make it straightforward to add spine capacity incrementally in existing 19-inch racks without airflow redesign.

🖥️

High-Density 25GbE Server Access

When deployed as a leaf switch with QSFP28 breakout cables, the MSN3700-CS2FC becomes a 128-port 25GbE server access switch in 1U, giving full-rack connectivity at any speed per Insight documentation. This eliminates the need for separate 25G TOR switches in dense virtualization clusters. Each 100G QSFP28 uplink can break out to four 25GbE SFP28 host connections using passive DAC or AOC cables, keeping cable costs low inside the rack while 100G leaves the rack toward the spine. The Spectrum-2 ASIC's consistent 425 ns latency and deep buffering handle East-West VM migration and storage traffic simultaneously. Dual redundant AC supplies and Cumulus Linux automation make large fleets of leaf switches manageable with identical, scriptable configurations.

🌐

Super-Spine Aggregation

In multi-pod and multi-site cloud architectures, the SN3000 series scales upward to super-spine roles, and the MSN3700-CS2FC serves as a 100G aggregation point interconnecting pod spines. Its 32 x 100GbE ports provide up to 3.2 Tbps of pod-to-pod bandwidth per switch, and the Layer-3 feature set of the Spectrum-2 platform supports routed fabrics with ECMP across many parallel links. The 425 ns latency adds negligible delay to inter-pod traffic even through multiple fabric hops. ONIE and Cumulus Linux enable zero-touch provisioning when new spines are racked, critical for rapid capacity expansion. Dual 100-264 V AC supplies tolerate varied facility power, and NetworkTigers notes the platform's compact 1U form keeps interconnect density high in super-spine rows where rack units are scarce.

🧩

SDN and Network Automation Deployments

Organizations building software-defined networks choose Open Ethernet hardware like the MSN3700-CS2FC because it decouples hardware from software: the ONIE installer bootstraps Cumulus Linux (or alternative NOS images) on the integrated x86 management CPU. The Spectrum-2 ASIC exposes programmatic control suitable for SDN controllers, with Layer-2 and Layer-3 features supporting advanced SDN capabilities described in the NVIDIA SN3000 datasheet. Operators gain Linux-native automation, streaming telemetry, and DevOps toolchains for configuration-as-code across the 32 x 100GbE ports. The 6.4 Tbps capacity and 4.76 Bpps rate ensure the hardware is not the bottleneck in automated fabrics. Dual AC power supplies, rack rails, and standard-depth chassis complete a deployment-ready package for enterprises transitioning from vendor-locked CLI management to automated, API-driven network operations.

Сводка рекомендуемых товаров

MFM1T02A-T 100G QSFP28 transceiver for spine uplinks Используется в: Cloud-Scale Leaf/Spine Fabrics, Super-Spine Aggregation MFS1S00-V003E 100G QSFP28 breakout cable for 25G leaf downlinks Используется в: Cloud-Scale Leaf/Spine Fabrics, High-Density 25GbE Server Access MCX623106AN-CDAT ConnectX-6 100GbE NIC for storage hosts Используется в: Hyperconverged Storage Networks, SDN and Network Automation Deployments MFM1T02A-W 100G QSFP28 SR4 optical transceiver Используется в: Hyperconverged Storage Networks MCX653106A-HDAT ConnectX-6 Dx 200G-capable NIC for compute nodes Используется в: Big Data and Analytics Clusters MC3309136-003 100GbE QSFP28 passive DAC for in-rack links Используется в: Big Data and Analytics Clusters MCX512A-ACAT ConnectX-5 25GbE server NIC Используется в: High-Density 25GbE Server Access MSN3700-CS2RC NVIDIA Используется в: Super-Spine Aggregation, SDN and Network Automation Deployments
What is the port configuration of MSN3700-CS2FC?
The MSN3700-CS2FC provides 32 x 100GbE QSFP28 ports in a 1U chassis with 6.4 Tbps switching capacity. According to the NVIDIA SN3000 series datasheet, every QSFP28 port is fully splittable, so the same box can serve as a 32-port 100G spine or as a high-density leaf supporting up to 128 x 10/25GbE server connections using breakout cables.
What is the latency and throughput of the MSN3700-CS2FC?
The MSN3700-CS2FC delivers 6.4 Tbps of switching capacity with a forwarding rate of 4.76 Bpps and a cut-through latency of 425 ns. According to NetworkTigers product listings, this low consistent latency makes it suitable for leaf/spine fabrics supporting financial trading, high-performance storage, and large East-West analytics clusters where predictable microsecond-level latency matters more than raw port count.
What is the price of MSN3700-CS2FC?
Pricing for the MSN3700-CS2FC varies significantly by channel: new factory-sealed units from resellers such as ServerSupply are quote-based, while refurbished/refurb-in-stock units from NetworkTigers and Core 4 Solutions are typically far below list price. Exact unit pricing was not published in the verified data as of 2026-10-19; contact XAIPART for a same-day quote including lead time.
Where to buy MSN3700-CS2FC online?
The MSN3700-CS2FC is available from secondary-networking resellers and distributors including Router-Switch.com, ServerSupply, NetworkTigers, BrightStar Systems, and Core 4 Solutions, in both new factory-sealed and refurbished condition. XAIPART also supplies this unit; request a quote for current stock and lead time as of 2026-10-19. New sealed units often carry a 2-3 day ETA per ServerSupply listings.
What is the difference between MSN3700-CS2FC and MSN3700-VS2FC?
The MSN3700-CS2FC uses 32 QSFP28 ports at up to 100GbE, while the MSN3700-VS2FC uses 32 QSFP56 ports supporting up to 200GbE per port. According to Router-Switch, the -VS2FC provides roughly double per-port bandwidth on the same Spectrum-2 generation platform. Both are 1U rack switches, but the QSFP56 variant is not cable-compatible with existing QSFP28 DAC/AOC infrastructure without adapters.
What is the best drop-in replacement for MSN3700-CS2FC?
The closest same-platform replacement is the MSN3700-CS2RC, which is electrically and mechanically identical but differs in airflow direction. Supermicro SSE-SN3700-CS2RC/CS2FC units are OEM versions of the same Spectrum-2 32x100G platform. However, NVIDIA has issued EOL notifications for parts of the SN3000 line, so confirm current production status and suggested replacements in NVIDIA's EOL notice LCR-000875 before ordering.
Can MSN3700-CS2FC be used as a leaf switch?
Yes, the MSN3700-CS2FC works both as a 100G spine and as a high-density 10/25GbE leaf switch. According to Insight product documentation, its ports span 1GbE to 100GbE and fully split to 128 x 10/25GbE ports using breakout cables, allowing full-rack server connectivity at any speed with a variety of oversubscription (blocking) ratios in a single 1U box.
What is the airflow direction of MSN3700-CS2FC?
The MSN3700-CS2FC uses P2C (back-to-front) airflow, meaning air enters at the power/connector side and exhausts out the port side, also described as back-to-front airflow in ServerSupply and NetworkTigers listings. This matches hot-aisle exhaust rack designs. NVIDIA ordering documentation explicitly warns to pay attention to airflow direction when ordering, because the -RC suffix variant reverses the direction.
What operating system does the MSN3700-CS2FC run?
The MSN3700-CS2FC ships as an Open Ethernet switch with ONIE boot loader and Cumulus Linux pre-installed, running on an x86 management CPU. According to LSOLink and AICPLight product data, the ONIE environment also allows installation of alternative NOS platforms, giving operators full Linux-based automation, telemetry, and SDN controller integration for cloud-scale deployments.
Is MSN3700-CS2FC still in production or EOL?
The broader SN3000 platform remains documented as active by NVIDIA, but NVIDIA Networking has published EOL notifications (LCR-000875) covering specific Mellanox-era products with suggested replacements, and Supermicro lists the SSE-SN3700 series as discontinued/EOL. Lifecycle status should be confirmed per purchase order as of 2026-10-19; the secondary market for new-sealed and refurbished MSN3700 units is well stocked.
What is the power configuration of the MSN3700-CS2FC?
The MSN3700-CS2FC includes two AC power supplies with 100-264 V input for redundant operation, per ServerSupply specifications. Dual supplies enable N+1 redundancy so a single PSU failure does not interrupt the fabric. The 1U standard-depth chassis with rack rail kit is included, and the switch is rack-mountable in EIA-standard 19-inch racks.
MSN3700-CS2FC vs MSN3700-CS2RC - which should I choose?
Choose the -CS2FC for back-to-front (P2C) airflow racks and the -CS2RC for front-to-back airflow racks; the hardware is otherwise the same Spectrum-2 32x100GbE platform. According to NVIDIA ordering documentation, airflow direction is the key ordering decision, and mixing airflow directions in one rack without ducting causes thermal recirculation. Select based on your facility's cold-aisle/hot-aisle containment design.
Where to download MSN3700-CS2FC datasheet PDF?
The official datasheet is the NVIDIA Spectrum SN3000 Series Switches PDF available on nvidia.com, which covers the MSN3700-CS2FC platform specifications including port configuration, throughput, and software features. The hardware installation details are in the NVIDIA Spectrum-2 SN3000 1U/2U Hardware User Manual on docs.nvidia.com. Both documents are free downloads without registration, as of 2026-10-19.
What can replace MSN3700-CS2FC if it is out of stock?
Primary replacements are same-platform units: MSN3700-CS2RC (same switch, reverse airflow), the Supermicro SSE-SN3700-CS2FC OEM variant, or the NVIDIA OPN 920-9N201-00F7-0C0 which BrightStar Systems confirms is the identical hardware under the newer NVIDIA numbering. For higher bandwidth needs, SN4000 series switches are NVIDIA's suggested upgrade path in the EOL notice. Refurbished channels such as NetworkTigers stock MSN3700 units with 365-day warranty.
What are the key specifications of MSN3700-CS2FC that engineers should know?
The MSN3700-CS2FC is a 1U Spectrum-2 switch with 32 x 100GbE QSFP28 ports, 6.4 Tbps capacity, 4.76 Bpps forwarding, and 425 ns latency. It runs Cumulus Linux on an x86 CPU with ONIE, has dual redundant AC supplies (100-264 V), P2C back-to-front airflow, and standard depth. Ports split to 128 x 10/25GbE. These facts come from the NVIDIA SN3000 datasheet and distributor listings.

Справочные инженерные данные для MSN3700-CS2FC — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the MSN3700-CS2FC when you need a 32-port 100GbE spine or 128-port 25G-capable leaf in 1U with P2C (back-to-front) airflow, Cumulus Linux automation, and dual redundant AC supplies. Choose the MSN3700-CS2RC instead if your racks use front-to-back airflow - the hardware is otherwise identical. Choose the NVIDIA OPN 920-9N201-00F7-0C0 when procurement requires the newer NVIDIA part number; it is the same physical unit. The Supermicro SSE-SN3700 variants are functionally equivalent but EOL at Supermicro, so favor them only for matched-fleet expansion via the secondary market. If you need more than 100G per port, step up to the MSN3700-VS2FC (32 x 200G QSFP56), accepting new cable infrastructure. Trade-off to weigh honestly: parts of the SN3000 line carry NVIDIA EOL notifications, so for new long-life deployments evaluate the SN4000 series; for capacity expansion of existing Mellanox fabrics, the MSN3700-CS2FC remains the pragmatic, well-stocked choice as of 2026-10-19.

Сравнение с аналогами

Параметр Этот товар MSN3700-CS2RC 920-9N201-00F7-0C0 SSE-SN3700-CS2FC MSN3700-VS2FC
Package / Form Factor 1U rack-mount 1U rack-mount - same 1U rack-mount - same 1U rack-mount - same 1U rack-mount - same
Brand NVIDIA (Mellanox) NVIDIA NVIDIA Supermicro NVIDIA
Port Configuration 32 x 100GbE QSFP28 32 x 100GbE QSFP28 32 x 100GbE QSFP28 32 x 100GbE QSFP28 32 x 200GbE QSFP56
Lifecycle Status Active / secondary market Active / secondary market Active (NVIDIA OPN) EOL at Supermicro Active
Operating System Cumulus Linux / ONIE Cumulus Linux / ONIE Cumulus Linux / ONIE Cumulus Linux / ONIE Cumulus Linux / ONIE

Ключевые отличия

  • Dual identity Mellanox/NVIDIA OPN with active secondary supply chain (против SSE-SN3700-CS2FC)
  • Consistent 425 ns cut-through latency (против MSN3700-VS2FC)
  • Fully splittable ports up to 128 x 10/25GbE (против MSN3700-CS2RC)

Заметки по проектированию

Airflow direction is the single most common ordering mistake on the SN3000 platform. NVIDIA's own ordering documentation warns to pay attention to airflow direction at ordering time: -CS2FC is P2C (back-to-front), while -CS2RC is front-to-back. Mixing directions in one rack without blanking panels and ducting causes hot-air recirculation that can raise switch intake temperatures well above specification. Verify your rack's cold-aisle/hot-aisle containment before ordering spares so replacements match installed units.

The MSN3700-CS2FC uses two AC power supplies rated 100-264 V. For full N+1 redundancy, connect each PSU to a separate power feed or A/B branch circuits; on a single feed, the redundancy is nominal only. Confirm facility voltage stays within the 100-264 V window - low 100 V-class circuits under load can approach the lower limit. Per ServerSupply and LSOLink listings, the rail kit is included and the chassis is standard depth, which simplifies deployment in shallow colocation cabinets.

Plan for platform lifecycle: NVIDIA has issued EOL notifications (LCR-000875) covering Mellanox-era products with suggested replacements, and Supermicro has discontinued the SSE-SN3700 series. Before standardizing on this platform for new builds, confirm the production status of your specific OPN and evaluate the SN4000 series as the forward path. The secondary market (NetworkTigers, Core 4 Solutions, BrightStar) currently offers new-sealed and refurbished MSN3700 units, with the NVIDIA OPN 920-9N201-00F7-0C0 identifying identical hardware.

Информация о соответствии

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

Compliance data was not present in the provided web data for this complete switch system. Refer to the NVIDIA SN3000 series datasheet and regulatory documentation for declarations.

Данные проверены: 2026-10-19 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

MSN3700-CS2FC MSN3700-CS2FC datasheet Mellanox MSN3700-CS2FC price 32 port 100GbE QSFP28 switch Spectrum-2 SN3700C 1U spine switch MSN3700-CS2FC vs MSN3700-VS2FC MSN3700-CS2FC drop-in replacement MSN3700-CS2FC Cumulus Linux switch buy MSN3700-CS2FC in stock what is the latency of MSN3700-CS2FC MSN3700-CS2FC airflow direction P2C Mellanox Spectrum-2 leaf spine data center switch

Связанные компоненты & термины

NVIDIA Mellanox MSN3700-CS2FC 920-9N201-00F7-0C0 MSN3700-VS2FC MSN3700-CS2RC SSE-SN3700-CS2FC Supermicro Spectrum-2 ASIC SN3000 series SN4000 series Ethernet switch leaf/spine switch QSFP28 QSFP56 100GbE Cumulus Linux ONIE Open Ethernet P2C airflow layer-2/layer-3 switching SDN data center fabric hyperconverged storage
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ