Belden

OZD PROFI 12M G11 - PROFIBUS Fiber Optic Repeater | Hirschmann

Артикул: OZD PROFI 12M G11 ✓ Активен
В наличии Отправка в течение 1–3 рабочих дней
24 V DC Vdss IEC 61784 ED.1:2002 CPF3/1, EN 50170 part 1 Rds(on)
От $1180 USD / шт.
MOQ: 1 |
Цена обновлена: 2026-10-19
Оптовые цены
Кол-во Цена за ед. Итого
1 $1450 $1.450,00
10 $1380 $13.800,00
25 $1320 $33.000,00
50 $1250 $62.500,00
100 $1180 $118.000,00
ℹ️ Все цены указаны в USD

OZD PROFI 12M G11 Обзор

The Hirschmann OZD PROFI 12M G11 (order number 942 148-001, formerly 943 727-221) is a PROFIBUS fiber-optic repeater that converts electrical RS-485 PROFIBUS signals into optical signals over quartz glass fiber and back, while also functioning as a repeater to extend bus segment length. It provides 1 optical port (2 x BFOC 2.5 ST-style sockets) and 1 electrical port (Sub-D 9-pin female, EN 50170 part 1 pin assignment) and supports PROFIBUS DP-V0, DP-V1, DP-V2 and FMS signal types. The G11 standard variant is qualified for hazardous-area deployment in Ex-zone 2 (Class I, Division 2).

A PROFIBUS fiber-optic repeater is an industrial networking device that bridges copper-based RS-485 fieldbus segments with optical fiber segments. Repeaters sit at the physical layer of the OSI model, regenerating and retiming signals to extend bus reach beyond the copper segment limit (typically 1200 m at 9.6 kBit/s down to 100 m at 12 Mbit/s) and to provide galvanic isolation between segments, which eliminates ground-loop-induced communication errors and adds immunity to electromagnetic interference (EMI) on factory floors.

Key features include a 24 V DC supply input, multimode 860 nm optical wavelength, IP40 protection rating, and rail-mount DIN-style housing. The repeater function is enabled by default and is user-configurable via DIP switches, including signal regeneration, segment termination, and functional compatibility with earlier OZD Profi generations. The unit is part of the OZD Profi 12M family from Belden/Hirschmann, the de-facto standard for PROFIBUS optical networking in process automation.

The OZD PROFI 12M G11 is designed for use in optical PROFIBUS field bus networks according to IEC 61784 ED.1:2002 CPF3/1. Internally it implements a transparent RS-485 to optical media converter that does not introduce measurable jitter at PROFIBUS data rates up to 12 Mbit/s. The two ST (BFOC 2.5) optical sockets allow daisy-chained or redundant ring topologies by simply connecting TX of one segment to RX of the next.

Typical applications include PROFIBUS DP segment extension in factory automation, optical isolation between welding robots and PLC cabinets, hazardous-area PROFIBUS networks in chemical and petrochemical plants, and redundant fiber backbone rings in power plants and water/wastewater facilities. The Ex-zone 2 (Class I Div 2) approval makes it particularly attractive for Zone-classified process-industry installations.

When designing with this device, remember that each repeater counts toward the maximum number of repeaters allowed per PROFIBUS segment (typically 9 between any two masters). Always enable bus termination on the end segments only, and verify fiber budget against the 860 nm attenuation specification of your multimode cable.

This page synthesizes distributor pricing, drop-in same-family variants, and practical design notes for engineers specifying PROFIBUS optical repeaters, complementing the manufacturer datasheet with peer-cited alternatives.

Аналоги без доработки для OZD PROFI 12M G11 — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

OZD Profi 12M G11 PRO

✅ Прямая замена
📦 Same DIN-rail housing, identical Sub-D 9 + 2x BFOC 2.5 ports
943 905-221 vs 942 148-001, newer PRO generation, same electrical/optical connectors and 24 V DC supply, DIP-switch controlled backward compatibility

📋 Справочный аналог (нет в каталоге)

OZD Profi 12M G11-1300

✅ Прямая замена
📦 Same DIN-rail housing, identical Sub-D 9 + 2x BFOC 2.5 ports
942 148-004 vs 942 148-001, 1300 nm vs 860 nm optical wavelength for long-haul fiber, same 24 V DC supply and connectors

📋 Справочный аналог (нет в каталоге)

OZD Profi 12M G12

✅ Прямая замена
📦 Same DIN-rail housing, identical Sub-D 9 + 2x BFOC 2.5 ports
Standard 0-60C climate range vs G11, same electrical/optical interface, same 24 V DC supply

📋 Справочный аналог (нет в каталоге)

OZD Profi 12M G12-EEC

✅ Прямая замена
📦 Same DIN-rail housing, identical Sub-D 9 + 2x BFOC 2.5 ports
Extended -20C to +60C climate range vs standard G11 (0-60C), same electrical/optical interface and 24 V DC supply

📋 Справочный аналог (нет в каталоге)

OZD Profi 12M G11-1300 PRO

✅ Прямая замена
📦 Same DIN-rail housing, identical Sub-D 9 + 2x BFOC 2.5 ports
PRO generation with 1300 nm optical window, same Sub-D 9 + BFOC 2.5 connectors, extended backward compatibility DIP

📋 Справочный аналог (нет в каталоге)

OZD PROFI 12M G11 Характеристики (опубликованы производителем)

Product Type PROFIBUS Fiber-Optic Repeater / Electrical-to-Optical Converter
Manufacturer Order Number 942 148-001 (formerly 943 727-221)
Бренд Hirschmann (Belden)
Supported Protocols PROFIBUS DP-V0, DP-V1, DP-V2, FMS
Standards Compliance IEC 61784 ED.1:2002 CPF3/1, EN 50170 part 1
Optical Ports 2 x BFOC 2.5 (STR) sockets, ST-compatible
Electrical Ports 1 x Sub-D 9-pin female, EN 50170 pin-out
Optical Wavelength 860 nm
Fiber Type Quartz glass multimode fiber
Напряжение питания 24 V DC
Protection Rating IP40
Maximum PROFIBUS Data Rate 12 Mbit/s
Hazardous Area Approval Ex-zone 2 (Class I, Division 2)
Repeater Function Yes (user-configurable via DIP switch)
Housing / Mounting DIN-rail mount industrial housing

Конфигурация выводов OZD PROFI 12M G11

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Контакт 1 NC — Not connected (per EN 50170 PROFIBUS DB9 pinout)
Контакт 2 NC — Not connected (per EN 50170 PROFIBUS DB9 pinout)
Контакт 3 RxD/TxD-P (Data B) — PROFIBUS RS-485 data line B (positive)
Контакт 4 RTS — Request To Send (direction control, PROFIBUS master)
Контакт 5 DGND — Data ground reference for PROFIBUS bus
Контакт 6 VP (+5V) — Termination supply voltage for bus terminator
Контакт 7 NC — Not connected (per EN 50170 PROFIBUS DB9 pinout)
Контакт 8 RxD/TxD-N (Data A) — PROFIBUS RS-485 data line A (negative)
Контакт 9 NC — Not connected (per EN 50170 PROFIBUS DB9 pinout)

Мощностные и тепловые характеристики

Входная мощность 24 V DC

Параметры входной мощности и тепловые параметры для OZD PROFI 12M G11, опубликованные производителем.

Типичное применение

OZD PROFI 12M G11 подходит для 6 применениеs: Factory Automation PROFIBUS Backbone, Hazardous-Area (Ex-zone 2) PROFIBUS Networks, Power Plant & Substation PROFIBUS Ring, Water/Wastewater Treatment Plant Networking, Robot Cell PROFIBUS Isolation, Long-Haul Plant PROFIBUS Backbone (G11-1300 variant).

🏭

Factory Automation PROFIBUS Backbone

The OZD PROFI 12M G11 is the de-facto PROFIBUS optical backbone component in discrete and process factories because it supports DP-V0/V1/V2 at 12 Mbit/s and converts RS-485 segments to 860 nm multimode fiber, immune to VFD and welding-rod EMI. Place one G11 at each cabinet exit to extend bus reach beyond the copper-segment limit and to provide galvanic isolation between machines. Compared to a copper-only segment, the G11 typically lifts PROFIBUS availability from days to years in noisy environments and adds zero measurable jitter at rated data rates per IEC 61784 CPF3/1.

⚡

Hazardous-Area (Ex-zone 2) PROFIBUS Networks

The G11 variant carries Ex-zone 2 / Class I Div 2 approval, allowing direct installation in cabinet rooms adjacent to classified process areas in chemical, petrochemical and pharmaceutical plants. It converts the safe-area copper PROFIBUS trunk into a fiber segment that crosses into Zone 2 hazardous areas, eliminating ground loops and providing inherent electrical isolation. Use one G11 per Zone-2 cabinet and pair with an IS barrier when extending into Zone 1 or Zone 0 field segments, per the Hirschmann installation manual and IEC 60079 series guidance.

🌐

Power Plant & Substation PROFIBUS Ring

In power-generation and T&D substations the G11 enables redundant fiber-optic PROFIBUS rings connecting generator controllers, turbine governors and protection relays across hundreds of meters. Two BFOC 2.5 sockets per unit support daisy-chain or counter-rotating ring topologies without external fiber patch panels. The IP40 industrial housing and 24 V DC supply integrate directly into substation DC battery systems, and the multimode fiber rejects the strong EMI fields typical of HV switchyards - a critical advantage over copper repeaters per IEC 61850-3 environments.

💧

Water/Wastewater Treatment Plant Networking

The OZD PROFI 12M G11 lets municipalities build long-distance PROFIBUS DP networks across treatment-plant tank farms, pump stations and remote wells where copper runs would exceed segment length or be exposed to moisture-induced ground faults. The multimode fiber with 860 nm optics tolerates the wet, corrosive environment and supports full 12 Mbit/s PROFIBUS DP-V2 to remote PLCs and VFDs. Compared to wireless alternatives, the G11 fiber link provides deterministic sub-millisecond latency required by closed-loop chemical-dosing control.

🤖

Robot Cell PROFIBUS Isolation

Welding robots and large servo drives generate extreme EMI that corrupts copper PROFIBUS cables inside a robot cell. The G11 placed at the cell boundary converts the noise-free copper trunk to a fiber segment that crosses the cell, providing complete galvanic isolation and EMI immunity. The two ST-style BFOC 2.5 optical sockets allow simple in-cell and out-of-cell connections with standard patch cords. Compared to copper through the cell, the fiber-optic approach eliminates intermittent CRC errors and reduces PROFIBUS fault diagnosis time by orders of magnitude.

✈️

Long-Haul Plant PROFIBUS Backbone (G11-1300 variant)

When the PROFIBUS backbone must run multi-kilometer distances between buildings or across large industrial campuses, the G11-1300 same-family variant (1300 nm wavelength, order number 942 148-004) provides the higher optical budget required for long-haul links. It is fully drop-in compatible with the G11 at the same Sub-D 9 electrical port and BFOC 2.5 optical sockets, allowing mixed copper/short-fiber/long-fiber segments within a single PROFIBUS network. The 1300 nm window also improves tolerance to fiber aging and reduces modal noise on legacy multimode plants.

Сводка рекомендуемых товаров

6GK1500-0EA02 Siemens PROFIBUS OLM/G12 comparable optical link module Используется в: Factory Automation PROFIBUS Backbone RS-FIBER-POF-PROFI Plastic-fiber alternative for short runs Используется в: Factory Automation PROFIBUS Backbone Pepperl+Fuchs KFD2-SR2-Ex2 IS barrier for downstream Zone 1 segments Используется в: Hazardous-Area (Ex-zone 2) PROFIBUS Networks Phoenix Contact FL ISOLATOR Galvanic isolation accessory Используется в: Hazardous-Area (Ex-zone 2) PROFIBUS Networks Siemens SIMATIC ET 200SP PROFIBUS DP slave for substation I/O Используется в: Power Plant & Substation PROFIBUS Ring ABB REF615 IED with PROFIBUS DP option Используется в: Power Plant & Substation PROFIBUS Ring Schneider Electric M340 BMXP342020 PLC with integrated PROFIBUS DP master Используется в: Water/Wastewater Treatment Plant Networking Phoenix Contact PSI-MODEM-PROFI PROFIBUS-to-fiber gateway Используется в: Water/Wastewater Treatment Plant Networking FANUC R-30iB PROFIBUS board Robot controller PROFIBUS slave option Используется в: Robot Cell PROFIBUS Isolation Siemens SINUMERIK PROFIBUS option board CNC PROFIBUS DP slave Используется в: Robot Cell PROFIBUS Isolation OZD Profi 12M G11-1300 Same-family drop-in with 1300 nm optics Используется в: Long-Haul Plant PROFIBUS Backbone (G11-1300 variant) Belden GBR8503 fiber cable Multimode 50/125 um fiber for 1300 nm Используется в: Long-Haul Plant PROFIBUS Backbone (G11-1300 variant)
What does the OZD PROFI 12M G11 do in a PROFIBUS network?
The OZD PROFI 12M G11 is a PROFIBUS fiber-optic repeater that converts electrical RS-485 PROFIBUS signals into optical signals on multimode quartz glass fiber and back again, while also regenerating and retiming signals as a bus repeater. According to the Hirschmann datasheet, it supports PROFIBUS DP-V0, DP-V1, DP-V2 and FMS at data rates up to 12 Mbit/s and complies with IEC 61784 ED.1:2002 CPF3/1.
What is the price of OZD PROFI 12M G11?
As of 2026-10-20, list pricing for the OZD PROFI 12M G11 from authorized Hirschmann/Belden distributors is approximately USD 1450 at qty 1, USD 1380 at qty 10, USD 1320 at qty 25, USD 1250 at qty 50, and USD 1180 at qty 100. Pricing varies by distributor and region; request a formal quote from XAIPART for current bulk pricing.
Where can I buy the OZD PROFI 12M G11 online?
The OZD PROFI 12M G11 is available from authorized industrial-networking distributors including Mouser, RS Online (us.rs-online.com part 70055978), Radwell, Industrial Networking Inc., and Adatronix, plus direct from Belden/Hirschmann channel partners. XAIPART stocks the 942 148-001 variant with typical lead time of 5-10 business days.
What is the lead time for OZD PROFI 12M G11?
Standard lead time for the OZD PROFI 12M G11 (order number 942 148-001) is typically 5-10 business days from authorized Belden/Hirschmann distributors when not in stock at the channel. For Zone 2-certified (Ex) variants or large-quantity orders, expect 4-6 weeks. Check real-time stock on Mouser or Octopart for immediate availability.
Is the OZD PROFI 12M G11 in stock?
Stock status varies by distributor and region; as of 2026-10-20 the part appears in industrial-channel inventory at Mouser, RS Online and several authorized Belden partners. For guaranteed availability and Zone-2 certification documentation, request a stock check via XAIPART or contact your local Hirschmann distributor.
What is the difference between OZD PROFI 12M G11 and G11 PRO?
The OZD PROFI 12M G11 (order number 942 148-001) is the standard PROFIBUS fiber-optic repeater, while the G11 PRO (order number 943 905-221) is the newer PRO-generation variant with enhanced functional compatibility for mixed operation with previous OZD generations. According to Belden/Hirschmann documentation, both share the same 2 x BFOC 2.5 optical interface and Sub-D 9-pin electrical port, and the G11 PRO replaces the original 943 727-221.
What is the difference between OZD PROFI 12M G11 and G12?
The OZD PROFI 12M G11 and G12 differ primarily in their specified climatic ambient conditions. According to the Hirschmann user manual, the G11 is the standard PROFIBUS optical repeater, while the G12 supports the standard 0°C to +60°C range and the G12-EEC extends operation to -20°C to +60°C for outdoor or unconditioned-cabinet installations.
What is the difference between OZD PROFI 12M G11 and G11-1300?
The OZD PROFI 12M G11 uses 860 nm optical wavelength for multimode quartz-glass fiber at standard segment lengths, while the G11-1300 variant uses the 1300 nm wavelength window for longer-haul or single-mode-capable links. According to Belden catalog data, the G11-1300 is qualified for Ex-zone 2 (Class I, Div 2) just like the standard G11, but supports greater optical budget.
When should I choose OZD PROFI 12M G11 over the G11 PRO?
Choose the OZD PROFI 12M G11 (942 148-001) for new installations that use only current-generation OZD Profi 12M repeaters and do not need mixed backward compatibility. Choose the G11 PRO (943 905-221) when the network must interoperate with older OZD Profi generations and you need the functional compatibility DIP switch (S8=0) feature, per the Hirschmann installation guide.
What is the best drop-in replacement for OZD PROFI 12M G11?
The closest drop-in same-family replacement for the OZD PROFI 12M G11 is the G11 PRO variant (943 905-221) which uses the same Sub-D 9-pin electrical and BFOC 2.5 optical connectors and the same 24 V DC supply. For long-haul links, the OZD Profi 12M G11-1300 (942 148-004) is the same-family drop-in with a 1300 nm optical window for higher fiber budget.
Where to download OZD PROFI 12M G11 datasheet PDF?
The official OZD PROFI 12M G11 datasheet (techdata PDF) can be downloaded from the Belden catalog at https://catalog.belden.com/techdata/EN/OZDProfi12MG11PRO_techdata.pdf. The full installation manual is available at https://www.doc.hirschmann.com/pdf/IG_OZD_Profi_12M_06_0423_en_2023-04-04.pdf. Both documents include pinout, DIP-switch settings, and approvals.
What is the OZD PROFI 12M G11 pinout?
The OZD PROFI 12M G11 electrical port uses a Sub-D 9-pin female connector with pin assignment per EN 50170 part 1 for PROFIBUS DP. Pin 3 is Data B (RxD/TxD-P), pin 8 is Data A (RxD/TxD-N), pin 5 is DGND, pin 6 is VP (+5 V termination), and pin 4/9 are RTS/Reserved, exactly matching the standard PROFIBUS DB9 pinout for RS-485 segments.
Is the OZD PROFI 12M G11 suitable for hazardous areas?
Yes, the OZD PROFI 12M G11 is approved for use in Ex-zone 2 (Class I, Division 2) hazardous locations according to the Hirschmann datasheet. For Zone 1 or Zone 0 installations, use an intrinsically safe barrier between the G11 and any field equipment installed in the classified zone.
What is the difference between OZD PROFI 12M G11 and a regular PROFIBUS repeater?
The OZD PROFI 12M G11 is both a PROFIBUS RS-485 repeater (regenerating electrical signals to extend copper segments) AND an electrical-to-optical media converter. According to IEC 61784 CPF3/1, this dual function lets one device serve as both a copper-segment repeater and the gateway to a fiber-optic segment, saving cost and panel space compared to separate units.
Can the OZD PROFI 12M G11 be used with single-mode fiber?
The OZD PROFI 12M G11 uses 860 nm wavelength on multimode quartz-glass fiber (BFOC 2.5 ST sockets) for typical industrial PROFIBUS links. For single-mode or long-haul applications, use the OZD Profi 12M G11-1300 variant (942 148-004) which operates at 1300 nm and supports higher optical budget per Belden catalog specifications.

Справочные инженерные данные для OZD PROFI 12M G11 — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the OZD PROFI 12M G11 (942 148-001) for a new PROFIBUS fiber backbone in a standard factory or process environment using all current-generation OZD Profi 12M units and 860 nm multimode fiber. Choose the G11 PRO (943 905-221) if the network must interoperate with older OZD generations and you need the S8 backward-compatibility DIP. Choose the G11-1300 (942 148-004) for long-haul or higher-loss fiber runs at 1300 nm. Choose the G12-EEC if the repeater will sit in an outdoor or unconditioned cabinet requiring -20C to +60C operation. All variants share the same DIN-rail housing, Sub-D 9 electrical port and 2 x BFOC 2.5 optical connectors, so cabinet layout and PROFIBUS wiring are fully reusable across the family.

Сравнение с аналогами

Параметр Этот товар OZD Profi 12M G11 PRO OZD Profi 12M G11-1300 OZD Profi 12M G12 OZD Profi 12M G12-EEC
Brand Belden / Hirschmann Belden / Hirschmann Belden / Hirschmann Belden / Hirschmann Belden / Hirschmann
Package / Housing DIN-rail industrial housing; Sub-D 9 + 2x BFOC 2.5 (ST) ports Same DIN-rail housing, same connectors Same DIN-rail housing, same connectors Same DIN-rail housing, same connectors Same DIN-rail housing, same connectors
Optical Wavelength 860 nm 860 nm 1300 nm 860 nm 860 nm
PROFIBUS Data Rate Up to 12 Mbit/s Up to 12 Mbit/s Up to 12 Mbit/s Up to 12 Mbit/s Up to 12 Mbit/s
Supply Voltage 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC
Repeater Function Yes (user-configurable DIP) Yes (with backward-compatibility DIP S8) Yes (long-haul) Yes Yes

Ключевые отличия

  • Backward-compatible PRO generation with explicit mixed-generation DIP (против OZD Profi 12M G11 PRO)
  • Long-haul 1300 nm optical window for higher-loss fiber runs (против OZD Profi 12M G11-1300)
  • Extended -20C to +60C temperature range for outdoor/unconditioned cabinets (против OZD Profi 12M G12-EEC)

Заметки по проектированию

Mount the OZD PROFI 12M G11 vertically on a 35 mm DIN rail inside a grounded metal cabinet, leaving at least 30 mm clearance above and below for fiber bend radius (minimum 30 mm for ST/BFOC 2.5 patch cords). Route the 24 V DC supply from a dedicated, fused circuit and keep PROFIBUS cable separated from power wiring by at least 100 mm to preserve the IP40 rating and minimize conducted noise coupling. The two BFOC 2.5 sockets are NOT redundant by default - confirm ring topology is implemented externally via fiber patch cords before relying on it for redundancy.

PROFIBUS DP at 12 Mbit/s requires that each copper segment be terminated at both physical ends with the standard 220 ohm / 390 ohm termination network per EN 50170. When inserting a G11, only terminate the two copper segments directly attached to its Sub-D 9 port - never terminate on the fiber side. Enable the G11's built-in repeater function via DIP switch only when the copper segment length would otherwise exceed the PROFIBUS baud-rate-dependent limit (e.g. 100 m at 12 Mbit/s down to 1200 m at 9.6 kbit/s).

Estimated: do not exceed 9 repeaters between any two PROFIBUS DP masters per the PROFIBUS specification. Mixing OZD Profi 12M...b (current generation) with OZD Profi 12M...c (previous) requires setting DIP switch S8=0 to disable functional compatibility per the Hirschmann installation guide. Avoid using single-mode fiber with the standard 860 nm G11 - the optical budget will not be met; use the G11-1300 variant instead. Verify Zone-2 approval certificate validity for the specific manufacturing date before installing in a classified area.

Информация о соответствии

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Без свинца
Yes
Без галогенов
Unknown
Конфликтные минералы
Compliant

Ex-zone 2 / Class I Div 2 hazardous-area approval per Hirschmann datasheet. PROFIBUS compliance per IEC 61784 ED.1:2002 CPF3/1 and EN 50170. RoHS and lead-free compliant per Belden product page.

Данные проверены: 2026-10-20 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

OZD PROFI 12M G11 OZD PROFI 12M G11 datasheet Hirschmann OZD PROFI 12M G11 price PROFIBUS fiber optic repeater 12 Mbit/s PROFIBUS DP to fiber converter Ex-zone 2 OZD Profi 12M G11 vs G11 PRO 942 148-001 PROFIBUS repeater Belden Hirschmann PROFIBUS optical link module OZD PROFI 12M G11 pinout DB9 PROFIBUS multimode fiber repeater 860 nm what is a PROFIBUS fiber optic repeater OZD Profi 12M G11-1300 long haul

Связанные компоненты & термины

Hirschmann Belden OZD PROFI 12M G11 942 148-001 OZD Profi 12M G11 PRO OZD Profi 12M G11-1300 OZD Profi 12M G12 OZD Profi 12M G12-EEC PROFIBUS PROFIBUS DP DP-V0 DP-V1 DP-V2 FMS IEC 61784 CPF3/1 EN 50170 RS-485 BFOC 2.5 ST connector Sub-D 9-pin multimode fiber quartz glass fiber 860 nm wavelength 1300 nm wavelength Ex-zone 2 Class I Division 2 fiber-optic repeater electrical-to-optical converter bus repeater DIN-rail mount IP40 24 V DC
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ