SN65HVD253D - Industrial CAN Transceiver | Texas Instruments
Артикул: SN65HVD253D ✓ АктивенSN65HVD253D Обзор
A CAN transceiver is an interface circuit that converts logic-level signals from a CAN controller into a balanced differential bus signal and converts the received differential signal back into a logic-level output. In the product hierarchy, the SN65HVD253D is a CAN transceiver, a bus interface IC, an interface integrated circuit, and ultimately a semiconductor. It is designed for industrial equipment using a CAN network, where robust differential signaling helps carry data reliably across equipment and wiring.
Key features include a single 5 V transceiver arrangement, differential transmit and receive capability, compatibility with ISO 11898-2:2003, and DeviceNet-compatible operation. The 8-SOIC outline is suitable for conventional surface-mount PCB assembly. The SN65HVD253D also supports a listen-only loopback arrangement through its AB pin, allowing the local CAN controller to synchronize with the bit rate observed on the bus. Detailed bus timing, common-mode range, and electrical limits are defined by the manufacturer datasheet.
Technically, the transceiver places a physical-layer interface between a CAN controller and the network. The transmitter drives the CANH and CANL conductors differentially, while the receiver interprets the polarity and magnitude of the differential bus voltage. The AB function changes the local behavior from normal bus participation to receive-only synchronization operation. This makes the device particularly useful when a controller must determine the active network baud rate before transmitting or during diagnostic procedures.
Typical applications include DeviceNet equipment, industrial sensors, factory automation controllers, motor-control systems, and other CAN-based industrial nodes. In a controller-to-transceiver arrangement, the CAN controller connects to the logic-side pins while the SN65HVD253D connects through CANH and CANL to the network. This partition keeps the controller sensitive to digital supply conditions and lets the transceiver interface with the bus voltage environment.
PCB design should preserve the transceiver’s isolation from noisy power and signal paths. Place the device close to the CAN bus connector or termination network when practical, route CANH and CANL as a tight differential pair, and provide a solid ground reference. Use the manufacturer’s recommended bus termination and protection components, and verify that the selected protection device has low capacitance and suitable CAN common-mode behavior.
This page combines the exact orderable part information, technical interface features, application guidance, package considerations, and structured comparisons for the SN65HVD253D. It also highlights the functional differences among same-family transceivers so engineers can distinguish a physical pin-compatible option from a device whose sleep, reference, or loopback behavior changes the board-level function.
Аналоги без доработки для SN65HVD253D — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с SN65HVD253D (тот же форм-фактор и посадочное место) — отличается по Supply Voltage, Mounting Type, Package, RoHS Status, Operating Temperature.
SN65HVD252D
✅ Прямая замена ⚠️ Характеристики не проверены📋 Справочный аналог (нет в каталоге)
SN65HVD254D
✅ Прямая замена ⚠️ Характеристики не проверены📋 Справочный аналог (нет в каталоге)
SN65HVD255DR
✅ Прямая замена ⚠️ Характеристики не проверены✓ В наличии
$1.12 / шт.
Открыть даташит →SN65HVD256D
✅ Прямая замена ⚠️ Характеристики не проверены📋 Справочный аналог (нет в каталоге)
SN65HVD230DR
✅ Прямая замена ⚠️ Характеристики не провереныУточнить цену
Открыть даташит →SN65HVD253D Характеристики
| Product Type | 1/1 CAN transceiver (unitless) |
| Напряжение питания | 5 V |
| Корпус | 8-SOIC, 0.154 in (3.90 mm) body width |
| CAN Compatibility | ISO 11898-2:2003 |
| DeviceNet Compatibility | Meets or exceeds DeviceNet transceiver specifications |
| Transmitter Count | 1 transmitter (unitless) |
| Receiver Count | 1 receiver (unitless) |
| Bus Interface | Differential CANH and CANL (unitless) |
| AB Interface Function | Listen-only loopback for baud-rate synchronization (unitless) |
| Тип монтажа | Surface mount (unitless) |
| Статус RoHS | unknown |
| REACH Status | unknown |
| AEC-Q100 Qualification | unknown |
| Lead-Free Status | unknown |
Руководство по цоколевке SN65HVD253D в корпусе 8-soic, 0.154 in (3.90 mm) body width
Цоколевка для SN65HVD253D (корпус 8-soic, 0.154 in (3.90 mm) body width). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.
Нет подробных данных о распиновке для SN65HVD253D.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
SN65HVD253D подходит для 6 применениеs: DeviceNet Industrial Sensors, Factory Automation Controller, Motor Control and Drive Systems, Industrial Communication Gateways, Automated Test Equipment, Industrial Diagnostics and Service Tools.
DeviceNet Industrial Sensors
The SN65HVD253D fits DeviceNet sensor and actuator nodes because the SN65HVD252 and SN65HVD253 family meets or exceeds DeviceNet transceiver specifications. Place it between the CAN controller and the CANH/CANL bus so logic-side signaling remains separate from the physical network. Its ISO 11898-2:2003 compatibility supports standard industrial CAN communication, while the 8-SOIC package simplifies assembly on controller boards. The AB listen-only function can help a node observe the active bus rate before normal participation, which is useful during startup, diagnostics, or configuration when the controller must synchronize with existing network traffic.
Рекомендуется
Factory Automation Controller
The SN65HVD253D is suitable for a factory automation controller that communicates over a multi-node CAN network. Its single transmitter and single receiver provide the physical interface between the controller logic and the differential CAN bus, while the 5 V supply matches the stated device family operating class. ISO 11898-2:2003 compatibility supports the network rules used by industrial automation equipment. The AB listen-only loopback provides a way for the controller to synchronize its baud rate with traffic already present on the bus, reducing the chance of inconsistent timing during initialization.
Рекомендуется
Motor Control and Drive Systems
The SN65HVD253D can be used in motor-control and drive electronics where a controller communicates with drives over a CAN network. Differential CANH and CANL signaling supports a bus interface that is appropriate for industrial equipment with multiple nodes and wiring between modules. The 8-SOIC package keeps the physical-layer device compact while remaining straightforward to assemble and inspect. When a drive needs to determine the network bit rate before transmitting, the AB listen-only loopback allows the local controller to synchronize with the bus rather than relying on a potentially mismatched preset rate.
Рекомендуется
Industrial Communication Gateways
The SN65HVD253D is appropriate for industrial communication gateways that bridge a CAN network to another control or data domain. The transceiver isolates the controller’s digital interface from the physical CAN bus and provides one transmit and one receive path in an 8-SOIC package. Compatibility with ISO 11898-2:2003 gives designers a defined baseline for standard CAN physical-layer operation, while DeviceNet-compatible performance supports use in industrial equipment. The AB function can assist gateways joining an active bus by allowing the host controller to observe and synchronize with the network bit rate.
Рекомендуется
Automated Test Equipment
The SN65HVD253D can support automated test equipment that communicates over CAN with industrial devices under test. Its differential bus interface is suited to shared test systems where reliable signaling is needed across wired equipment connections, and its 8-SOIC package allows placement close to the CAN connector or termination. The listen-only loopback is useful when the test controller must acquire the bus rate before taking control of the network. Because the device is listed as an industrial CAN transceiver and supports ISO 11898-2:2003, it provides a standard physical-layer foundation for automated equipment diagnostics.
Рекомендуется
Industrial Diagnostics and Service Tools
The SN65HVD253D is useful in portable industrial diagnostics and service tools that connect to equipment operating on a CAN bus. Its 5 V transceiver arrangement and 8-SOIC package support compact circuit-board implementations, while the differential bus interface links the tool to the equipment network. The AB listen-only mode is particularly valuable during passive diagnostics because it lets the local controller synchronize with the network’s baud rate before deciding whether and when to transmit. This behavior helps service equipment participate more reliably in systems where multiple products may use different communication settings.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для SN65HVD253D — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | SN65HVD252D | SN65HVD254D | SN65HVD255D | SN65HVD256D | SN65HVD230D |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC |
Ключевые отличия
- Dedicated listen-only bus synchronization function (против SN65HVD252D)
- DeviceNet-oriented family positioning (против SN65HVD230D)
- Standardized industrial CAN compatibility (против SN65HVD255D)
- Compact integrated bus interface (против SN65HVD256D)
Заметки по проектированию
Route CANH and CANL as a tightly coupled differential pair and keep the route away from switching nodes, high-current return paths, and unrelated clock signals. Connect the transceiver ground to the controller ground through a low-impedance plane path rather than relying on the bus shield or connector return. Place the device and its bus-side protection components near the CAN connector when practical, while following the manufacturer’s recommended component arrangement.
Do not approve a replacement solely because it fits the 8-SOIC outline. SN65HVD252D uses pin 5 as a VCC/2 reference, whereas SN65HVD253D uses AB for listen-only loopback. Also verify supply voltage, logic thresholds, propagation delay, bus common-mode range, and timeout behavior for any proposed substitute. A footprint match is necessary for PCB reuse, but it does not establish functional drop-in compatibility.
Decouple the transceiver supply locally and follow the manufacturer’s specified capacitor network and placement. Keep the 5 V supply return path continuous and separate noisy switching-current routing from the CAN interface area. If the surrounding equipment uses high-current actuators, validate the CAN bus reference potential under worst-case loading; an acceptable logic-side supply does not guarantee acceptable bus common-mode conditions.
Use the AB listen-only function only within the behavior specified by the manufacturer. It allows the local controller to synchronize with the bus bit rate, but it should not be treated as general-purpose transmit disable unless the application confirms that interpretation. During diagnostics, preserve the controller’s configured baud rate and termination assumptions so that observing the bus does not introduce an unintended node state.
Информация о соответствии
The manufacturer description confirms ISO 11898-2:2003 compatibility and DeviceNet transceiver performance, but the supplied product information does not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status.