Detalyadong pagkakahiwalay na pagkakahambing ng MPXV7025DPT1 sa pamamagitan ng NXP Semiconductors at MPXV7025GC6U sa pamamagitan ng STMicroelectronics. Ikinahambing ang mga pangunahing paglalarawan, mga tama ng elektriko, paakay, kalagayan ng buhay, presyo, at pagkakaroon upang makita ang pinakamahusay na komponente para sa iyong mga kinakailangang pang disenyo.
NXP Semiconductors
MPXV7025DPT1 - ±25 kPa Differential Pressure Sensor | NXP
MPXV7025DPT1 ✓ NakahandaPagsanggunian na paghahambing
| Parametro | MPXV7025DPT1 | MPXV7025GC6U |
|---|---|---|
| Brand | NXP Semiconductors | STMicroelectronics |
| Kategorya | Pressure Sensors | Pressure Sensors |
| Katayuan ng Lifecycle | Aktibo | Aktibo |
| Operating Pressure | ±3.63 PSI (±25 kPa) | — |
| Pressure Type | Differential | Compound (Gauge/Vacuum) |
| Type ng Output | Analog Voltage (ratiometric) | Analog Voltage, Ratiometric |
| Hanay ng Output Volte | 0.2 V to 4.7 V | 0.2 V to 4.7 V |
| Volte ng Pagbibigay | 5.0 V typical | — |
| Sensitivity | Approximately 90 mV/kPa | 90 mV/kPa (nominal) |
| Port Size | Male, 0.13 in (3.302 mm) tube, dual | — |
| Port Style | Dual ports, same side | Top, Axial, Male 3.18 mm (0.13 in) Tube |
| Packhaging / Kaso | 8-BSOP (0.475 in / 12.06 mm width) | — |
| Uri ng Pagpapasok | Surface Mount | Surface Mount |
| Temperature na Operasyon | -40 °C to +125 °C | 0 °C to +85 °C |
| Type ng Sensor | Piezoresistive (MEMS silicon) | — |
| On-Chip Signal Conditioning | Yes (calibrated and temperature-compensated) | — |
| Tindminan RoHS | Compliant | Compliant |
| Lead-Free | Yes | — |
| Pressure Range | — | -25 kPa to +25 kPa (-3.63 to +3.63 PSI) |
| Supply Voltage (VCC) | — | 4.75 V to 5.25 V (5 V typical) |
| Kuru-kuryente ng Pagbibigay | — | [DATA_NEEDED: supply current] |
| Accuracy | — | ±5 % (after calibration) |
| Packhaging | — | 8-SMD, Gull Wing, Top Port (SOP 8) |
| Port Termination | — | Axial barbed tube port |
| Technology | — | Piezoresistive MEMS, on-chip signal conditioned, temperature compensated, calibrated |
| Level ng MSL | — | [DATA_NEEDED: MSL level] |