AD693AD - 4-20mA Signal Conditioner | Analog Devices

MPN: AD693AD ✓ Nakahanda
12 V to 36 V Vdss 0-20 mA or 4-20 mA, depending on configuration Id 20-lead ceramic DIP Package
MOQ: 1 |

AD693AD Ulas

The Analog Devices AD693AD is a monolithic loop-powered 4-20 mA sensor signal conditioner with an instrumentation-amplifier front end, on-chip voltage reference, and auxiliary amplifier. It accepts low-level transducer inputs, supports precalibrated 30 mV and 60 mV input spans, and drives a standard two-wire current loop. The device is supplied in a 20-lead ceramic DIP package and operates from a 12 V to 36 V loop supply.

A 4-20 mA current-loop transmitter is a signal-conditioning device that converts a low-voltage sensor or transducer signal into a standardized current carried over a two-wire cable. The current format allows sensing and power to share the same conductors, making the AD693AD relevant to industrial instrumentation, process measurement, and remote sensor interfaces. Its loop-powered architecture separates the available loop power from the low-level signal being conditioned.

The AD693AD integrates a five-amplifier instrumentation-amplifier front end, an on-chip reference, and an auxiliary amplifier. Precalibrated input spans include 30 mV and 60 mV, with spans between those values also characterized when operated as a loop-powered transmitter. Precalibrated output configurations include 4-20 mA unipolar, 0-20 mA unipolar, and an 8 mA bipolar output, giving designers several standardized current-output choices.

The AD693AD is designed for transducer interfaces that require low-level amplification and current-loop output in one compact circuit. Its stated input offset voltage is 200 microvolts, while the loop-powered architecture supports equipment located far from the control or monitoring electronics. The integrated reference and auxiliary amplifier reduce the number of external signal-conditioning functions required for compatible sensor designs.

Typical applications include resistive temperature detector interfaces, process-control transmitters, industrial pressure and temperature instrumentation, and remote two-wire sensor loops. The manufacturer specifically identifies a precalibrated 100 ohm RTD interface, while the broader low-level input capability supports transducers whose output can be accommodated by the configured input span.

For a new design, confirm the selected input span, output range, external resistor values, pin assignment, and compensation requirements in the AD693 datasheet before layout. Because the device powers itself from the loop, verify that the available loop voltage remains within the stated 12 V to 36 V operating range after accounting for cable and load effects.

This product record consolidates the AD693AD functional description, package information, current-loop configurations, engineering use cases, and substitution limitations. The comparison also distinguishes verified characteristics from parameters that require confirmation in the manufacturer datasheet, helping engineers plan a sensor-transmitter design without assuming unverified electrical details.

Mga alternatibo na pwedeng ilagay na AD693AD — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.

Variante sa Seri na ito

Katulad na modelo sa serye na katugma sa pagpasok AD693AD (parehas na form factor at footprint) — pagkakaiba sa Package, Product Type, Mounting Type, RTD Interface, Auxiliary Amplifier.

Analog Devices
Package: 20-CLCC (9 x 9 mm)
Product Type: Loop-powered 4-20 mA sensor transmitter
Mounting Type: Surface mount
Ikabit sa AD693AD →
Analog Devices
Package: 20-pin CDIP
Product Type: Loop-powered 4-20 mA sensor transmitter and signal-conditioning IC
RTD Interface: 100 Ω RTD
Ikabit sa AD693AD →

Wala ng magagamit na drop-in alternatibo para sa produkto na ito.

Hilingin ang Alternatibo

AD693AD Mga Spesipikasyon

Product Type Monolithic 4-20 mA loop-powered sensor signal conditioner
Input Signal Type Voltage
Output Signal Type Current
Output Current Range 0-20 mA or 4-20 mA, depending on configuration
Supply Voltage Range 12 V to 36 V
Precalibrated Input Spans 30 mV and 60 mV
Offset Voltage 200 uV
Amplifier Configuration 5-amplifier instrumentation-amplifier front end
Integrated Reference On-chip voltage reference
Auxiliary Amplifier Integrated auxiliary amplifier
Powering Method Loop-powered from a two-wire current loop
RTD Interface Precalibrated 100 ohm RTD interface
Packhaging 20-lead ceramic DIP
Bilang ng Pin 20 pins
Uri ng Pagpapasok Through-hole

Gabay sa Pin Configuration ng AD693AD 20-lead ceramic dip

Pin configuration para sa AD693AD (20-lead ceramic dip package). Ang pagnunumero ng pin, mga function, at connection diagram ay tinukoy sa datasheet ng manufacturer. Sumangguni dito para sa eksaktong footprint at mga alituntunin sa soldering.

Pinout diagram ng 20-lead ceramic dip package para sa AD693AD

Wala ng detalyadong pinout data na magagamit para sa AD693AD.

Sumangguni sa datasheet para sa buong pin configuration.

Tipikal na mga Gamit

AD693AD ay nararapat para sa 6 aplikasyons: Industrial Pressure Transmitter, Resistance Temperature Detector Interface, Two-Wire Process Measurement Loop, Remote Temperature Monitoring, Industrial Current-Loop Signal Interface, Sensor Conditioner for Control Cabinets.

🏭

Industrial Pressure Transmitter

The AD693AD fits a remote pressure-transmitter design when the sensor produces a low-level voltage within the device's 30 mV or 60 mV precalibrated input spans. Its instrumentation-amplifier front end conditions the transducer output and converts it into a standard 4-20 mA or 0-20 mA loop current. Loop-powered operation lets the transmitter electronics draw power through the same two conductors that carry the measurement signal. The design must provide at least 12 V and no more than 36 V at the device under worst-case cable and load conditions, while the pressure sensor output must be matched to the selected AD693 input configuration.

🌡️

Resistance Temperature Detector Interface

The AD693AD is identified as supporting a precalibrated 100 ohm RTD interface, making it applicable to temperature measurement loops where the RTD signal must be transmitted remotely. Its 30 mV and 60 mV input-span options provide predefined gain choices for compatible low-level temperature signals. The resulting standard 4-20 mA output can connect to a controller, indicator, or data-acquisition system over a two-wire loop. Before finalizing the circuit, verify the RTD measurement range, excitation requirements, lead resistance, and calibration method against the Analog Devices AD693 datasheet.

📡

Two-Wire Process Measurement Loop

The AD693AD is well suited to process-measurement systems that combine a low-level transducer, remote electronics, and a standardized current output in one two-wire connection. Its monolithic design integrates the instrumentation-amplifier front end, voltage reference, and auxiliary amplifier, reducing the number of separate signal-conditioning blocks. Loop power supplies the circuit through the same conductors used for the 4-20 mA measurement signal. The engineering task is to confirm that the transducer's full-scale output fits a precalibrated input span and that the worst-case loop voltage remains inside the 12 V to 36 V operating range.

📈

Remote Temperature Monitoring

For remote temperature monitoring, the AD693AD can create a standardized current-loop signal from a compatible 100 ohm RTD or other low-level temperature sensor. Its stated 200 uV offset voltage, selectable 30 mV and 60 mV precalibrated spans, and 4-20 mA unipolar output support sensitive measurement-interface designs. The loop-powered arrangement is especially useful where running separate power and signal cables would be inconvenient. Field performance still depends on the selected sensor, input configuration, calibration range, cable resistance, and receiver instrumentation, all of which should be evaluated as part of the complete transmitter design.

🔧

Industrial Current-Loop Signal Interface

The AD693AD provides a dedicated interface between a low-level sensor output and a two-wire industrial current loop. It can produce a precalibrated 4-20 mA unipolar signal, a 0-20 mA unipolar signal, or an 8 mA bipolar signal, allowing compatibility with different process-input receivers. Because the device includes a 5-amplifier instrumentation front end, a voltage reference, and an auxiliary amplifier, the transmitter can be consolidated into a focused signal-conditioning circuit. Select the output configuration, external gain network, and loop-supply limits directly from the manufacturer documentation rather than inferring them from the generic current-loop function.

🏗️

Sensor Conditioner for Control Cabinets

The AD693AD can serve as the sensing element of a compact process-control transmitter mounted near a remote transducer. Its loop-powered architecture avoids a separate field-side power connection, while the integrated reference and auxiliary amplifier support the signal-conditioning function required for a stable current output. A 20-lead ceramic DIP package is appropriate for through-hole assembly and serviceable industrial electronics. Designers should still account for the 12 V minimum loop voltage, verify the transducer's output span, and use the AD693 pin and calibration information to avoid configuration errors during installation.

What is the AD693AD?
The AD693AD is a monolithic signal-conditioning IC from Analog Devices that accepts low-level transducer inputs and controls a standard 4-20 mA, two-wire current loop. According to the AD693 datasheet, the circuit combines an instrumentation-amplifier front end, an on-chip voltage reference, and an auxiliary amplifier. It is packaged as a 20-lead ceramic DIP and is intended for loop-powered sensor-transmitter equipment.
What is the operating voltage of AD693AD?
The AD693AD operates from a 12 V to 36 V loop supply. This supply is associated with the two-wire current loop rather than a separate low-voltage logic rail. The Analog Devices AD693 datasheet characterizes operation as a loop-powered transmitter, so the engineer should confirm that the voltage remaining at the device after cable and load effects stays within the specified 12 V to 36 V range.
What input spans are supported by the AD693AD?
The AD693AD includes precalibrated 30 mV and 60 mV input spans. The Analog Devices datasheet also states that specifications apply to those preset spans and to spans between them when the device operates as a loop-powered transmitter. This makes the device applicable to low-level transducer outputs, although the exact gain configuration and external network should be selected from the manufacturer documentation.
Which output-current configurations are available on the AD693AD?
The AD693AD supports precalibrated 4-20 mA unipolar, 0-20 mA unipolar, and 8 mA bipolar output configurations. These are standard industrial current-loop outputs designed to place the conditioned transducer signal into a two-wire transmitter loop. The Analog Devices AD693 datasheet remains the controlling reference for pin connections, calibration, and the external components required for each configuration.
Where can I download the AD693AD datasheet PDF?
The official AD693AD datasheet PDF is available from Analog Devices at https://www.analog.com/media/en/technical-documentation/data-sheets/AD693.pdf. It contains the electrical characteristics, pin descriptions, application information, and configuration details needed for a loop-powered sensor transmitter. Use the package-specific AD693AD ordering information together with the AD693 datasheet when checking the 20-lead ceramic DIP variant.
Where can I find the AD693AD pinout?
The AD693AD pin assignment is located in the pin-description section of the official AD693 datasheet. The component is a 20-lead ceramic DIP, so the PCB footprint must provide all 20 through-hole connections in the same physical arrangement as the manufacturer drawing. Assign tracks only after cross-checking every numbered terminal against the datasheet because the package drawing and the selected output configuration determine the functional connections.
Is the AD693AD suitable for RTD sensors?
Yes, the AD693AD is suitable for a precalibrated 100 ohm RTD interface. The Analog Devices documentation identifies this RTD capability among the features of the loop-powered transmitter, while the device also accepts low-level inputs from other transducers. Final suitability depends on the RTD measurement range, required accuracy, excitation behavior, and selected input configuration, which should be checked in the AD693 datasheet.
How does the AD693AD support a two-wire sensor loop?
The AD693AD derives operating power from the two-wire loop while separately conditioning the transducer signal for current-loop output. This arrangement allows a remote sensor and transmitter electronics to share two conductors, reducing field wiring requirements. According to the Analog Devices product description, the monolithic circuit includes the front end, voltage reference, and auxiliary amplifier needed for compatible low-level sensor interfaces.
Can an AD693AD be used for industrial pressure measurement?
The AD693AD can be used for a compatible low-level industrial pressure-transducer output when its input span, offset, and loop-supply requirements are satisfied. The device accepts low-level transducer inputs and provides a standardized 4-20 mA output, making it useful for remote process measurement. The transducer's full-scale millivolt output must be matched to the selected AD693 input span before the circuit is approved.
What is the best drop-in replacement for the AD693AD?
No verified drop-in replacement for the AD693AD was identified in the available cross-reference information. A valid replacement must match the 20-lead ceramic DIP footprint, remain pin-to-pin compatible, and preserve the 12 V to 36 V loop supply plus required input and output ranges. Treat any similarly described current-loop transmitter as a new design until its pinout and electrical characteristics have been checked directly against the AD693 datasheet.
What can replace the AD693AD?
The only defensible replacement candidates are devices documented as pin-to-pin compatible with the AD693AD in the same 20-lead ceramic DIP package. No such candidate is established by the available technical records, so the AD693AD should remain the qualified baseline rather than being replaced from a generic function description. Request a specific candidate and compare its loop voltage, input spans, output currents, and pin assignments before making a substitution.
When should I choose the AD693AD over a discrete transmitter design?
Choose the AD693AD when the design needs a compact, precalibrated 4-20 mA transmitter built around low-level transducer signals and a 12 V to 36 V loop supply. Its integrated instrumentation-amplifier front end, voltage reference, auxiliary amplifier, 30 mV and 60 mV input spans, and 100 ohm RTD interface can reduce discrete design effort. A discrete approach may be preferable only when the product requires functions or calibration behavior outside the AD693 specification.
Is the AD693AD suitable for process-control instrumentation?
Yes, the AD693AD is suitable for process-control instrumentation when the transducer output falls within its supported input spans and the field supply meets the 12 V to 36 V loop requirement. It generates a standard 4-20 mA current output for controllers, recorders, or remote monitoring systems. Confirm the specific transducer output, calibration range, loop resistance, and grounding arrangement in the manufacturer datasheet.
What are the key specifications of AD693AD that engineers should know?
The key AD693AD specifications are its loop-powered operation, 12 V to 36 V supply range, 30 mV and 60 mV precalibrated input spans, 4-20 mA unipolar output, 0-20 mA unipolar output, 8 mA bipolar output, and 200 uV offset voltage. The Analog Devices AD693 datasheet also identifies a 5-amplifier front end, integrated voltage reference, auxiliary amplifier, and precalibrated 100 ohm RTD interface.
Is the AD693AD the same as a generic 4-20 mA transmitter?
No, the AD693AD is more specific than a generic 4-20 mA transmitter. It is a particular Analog Devices monolithic IC with a 5-amplifier instrumentation front end, 30 mV and 60 mV precalibrated input spans, a 200 uV stated offset voltage, and operation from a 12 V to 36 V loop supply. Substitute devices must reproduce the required electrical performance and the exact 20-lead ceramic DIP pinout.
Where can I buy AD693AD online and what is the current lead time?
Use the Request a Quote form on this page to ask for AD693AD availability, current lead time, and a quotation for the required quantity and package variant. The AD693AD is identified as an Analog Devices 20-lead ceramic DIP loop-powered signal conditioner. XAIPART will return the current commercial terms through the quote process rather than publishing a static price or unconfirmed stock statement.

Impormasyon ng Talumpati sa Engineering for AD693AD — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.

Paunawang Hanapin

Choose the AD693AD when the design requires a compact, precalibrated, loop-powered transmitter for a compatible low-level transducer or 100 ohm RTD. It is particularly useful when the field must use a two-wire connection, the available loop voltage is between 12 V and 36 V, and the receiver expects 4-20 mA, 0-20 mA, or 8 mA bipolar current. Its monolithic integration can simplify a transmitter assembly compared with a discrete amplifier, reference, and current-output design. Do not select it when the transducer output falls outside the 30 mV or 60 mV spans, when another package or pin arrangement is required, or when a candidate replacement has not been verified against the 20-lead ceramic DIP footprint. Because no confirmed drop-in substitute was identified, the AD693AD should remain the baseline for new and existing designs pending a component-specific compatibility review.

Ikabit sa Mga Alternatibo

Parametro Ito ang Producto
Product Type Monolithic loop-powered 4-20 mA sensor signal conditioner
Brand Analog Devices
Package 20-lead ceramic DIP
Supply Voltage Range 12 V to 36 V
Precalibrated Input Spans 30 mV and 60 mV
Offset Voltage 200 uV
Output Configurations 4-20 mA unipolar, 0-20 mA unipolar, and 8 mA bipolar
Front-End Architecture 5-amplifier instrumentation-amplifier front end

Pangunahing mga Pagkakaiba

  • Combines signal conditioning and loop-current output in one monolithic IC (kumpara saNo verified drop-in alternative was identified)
  • Provides multiple precalibrated low-level input choices (kumpara saNo verified drop-in alternative was identified)
  • Supports field-powered remote instrumentation (kumpara saNo verified drop-in alternative was identified)

Talaan ng Disenyo

Design the field-side power budget around the specified 12 V to 36 V loop-supply range. Confirm the minimum voltage at the AD693AD under the maximum specified cable resistance and receiver burden rather than only at the power source. Use the manufacturer datasheet to determine startup, quiescent-current, and loop-current requirements; these values were not established for this record and should not be inferred from the supply-range description.

Follow the AD693 pin description and application diagrams when assigning the 20-lead ceramic DIP footprint. Keep sensitive input and feedback-network connections away from noisy current-loop and power paths, and use the manufacturer reference layout for grounding and decoupling. Because a complete public pin list was not established, cross-check every connection against the official datasheet before fabrication rather than relying only on the physical 20-pin package dimensions.

Match the transducer's full-scale millivolt output to the selected 30 mV or 60 mV input span and verify whether the receiver expects 4-20 mA unipolar, 0-20 mA unipolar, or 8 mA bipolar current. Do not assume that every current-loop transmitter with a similar function has identical calibration, compensation, or pin behavior. Validate the complete span and zero adjustment using the calibration procedure in the Analog Devices AD693 datasheet.

Impormasyon ng Pagsunod sa Kautusan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Walang Lead
Unknown
Walang Halogen
Unknown
Mga Conflict Mineral
Unknown

Compliance attributes were not identified in the available manufacturer and distributor product information.

Data napatotohanan sa: 2026-11-03 — impormasyon na pinatunayan at pinapatakbo ng pangkat ng engineering ng XAIPART's component engineering team

Kaugnay na Hanapin

AD693AD datasheet AD693AD datasheet pdf AD693AD pinout AD693AD specifications AD693AD equivalent AD693AD replacement AD693AD cross reference Analog Devices AD693AD AD693AD 20-CDIP AD693AD 4-20mA transmitter AD693AD price AD693AD stock

Mga kaugnay na Mga Komponente at mga Tuntunin

Analog Devices AD693 AD693AD signal conditioner sensor interface 4-20 mA current loop two-wire transmitter loop-powered instrumentation instrumentation amplifier 5-amplifier front end on-chip voltage reference auxiliary amplifier 30 mV input span 60 mV input span 200 uV offset voltage 12 V to 36 V loop supply 100 ohm RTD interface 20-lead ceramic DIP process-control transmitter industrial pressure transducer remote temperature monitoring current-loop signal conditioning
Mabilis na Tanggap na RFQ
Ihanda ang buong detalye — ang aming pangkalakal na koponan ay tutugon sa loob ng 24 oras
Numero ng Parte Mga Tagagawa Pakete QTY Target na Halaga Pinalawak
✓
Quote na inilabas!

Ating tumugon sa iyong email sa loob ng 24 oras

1
RFQ Naisumite
2
Received na ang Kwaliksik
3
Nai-order
4
Pagbabayad
5
Inihanda
6
Naihanda
Tingnan ang Detalye ng RFQ