Analog Devices

AD7730LBR - 24-Bit Low-Power Bridge ADC | Analog Devices

MPN: AD7730LBR ✓ Nakahanda
24-lead SOIC Package
MOQ: 1 |

AD7730LBR Ulas

The Analog Devices AD7730LBR is a low-power, 24-bit sigma-delta analog front end for bridge transducers, weighing systems, and pressure measurement. It provides one differential analog input channel, 600 samples per second operation, and a 24-lead SOIC package while consuming approximately 125 mW. The device is designed to accept low-level differential signals directly from load cells and other bridge-based sensors.

An analog front end for bridge transducers combines analog input conditioning, a sigma-delta converter, and digital filtering into one integrated circuit. The AD7730L belongs to the ADC, analog front end, and power management IC hierarchy. Its purpose is to convert small differential sensor voltages into high-resolution digital words while limiting external signal-conditioning components and minimizing power consumption in portable or distributed measurement systems.

The AD7730LBR provides programmable input ranges covering unipolar signals from 0 mV to ±10 mV, ±20 mV, ±40 mV, and ±80 mV, along with corresponding bipolar ranges. Programmable gain allows one converter design to serve transducers with different full-scale sensitivities. Its 24-bit resolution and digital filtering are useful when extracting low-level measurements that would otherwise be obscured by noise, offset drift, or gain drift.

Analog Devices specifies self-calibration and system-calibration options for the AD7730L family. Offset drift is less than 5 nV/°C and gain drift is less than 3 ppm/°C, supporting stable measurements when temperature changes. The low-power AD7730L consumes approximately one-third the power of the AD7730 according to the manufacturer product information, making it suitable for systems where converter power is a meaningful part of the overall budget.

Typical applications include digital weigh scales, industrial force transducers, pressure transmitters, laboratory measurement equipment, and portable weighing instruments. The 24-lead SOIC package supports conventional surface-mount assembly and provides a practical option for compact industrial and instrumentation electronics. The AD7730LBR ordering suffix identifies the tape-and-reel SOIC configuration; consult the manufacturer ordering table before finalizing procurement.

When designing the analog path, keep the bridge excitation and converter reference stable, route the differential input with closely matched geometry, and place input filtering close to the device. Allow the selected input range, gain, conversion rate, and digital filter settings to fit the mechanical bandwidth and required settling time. Calibrate offset and gain after installation because sensor orientation, loading, and temperature can affect the final system accuracy.

This product page combines the manufacturer device information with practical selection guidance, interface considerations, and a verified same-family drop-in comparison. It also highlights the distinction between the AD7730L low-power grade and the AD7730BRZ, helping engineers confirm temperature range, supply demand, and functional fit before committing to a PCB or production BOM.

Mga alternatibo na pwedeng ilagay na AD7730LBR — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.

Variante sa Seri na ito

Katulad na modelo sa serye na katugma sa pagpasok AD7730LBR (parehas na form factor at footprint) — pagkakaiba sa Gain Drift, Input Range, Offset Drift, Operating Temperature Range, Package.

Analog Devices
Gain Drift: < 2 ppm/°C
Input Range: Bipolar differential (bridge sensor level)
Offset Drift: < 5 nV/°C
Ikabit sa AD7730LBR →

AD7730BRZ

✅ Drop-In
Analog Devices
📦 24-lead SOIC
24-bit · Sigma-Delta · 1 differential bridge input · 1.2 kSPS · 5 V (typ) · 3 V to 5.25 V · 125 mW (typ) · < 5 nV/°C

Magkontak para sa presyo

Tingnan ang Datasheet →

AD7730LBR Mga Pinakamataas na Rating at Electrical Characteristics

Converter Type Sigma-delta ADC
Pangangasiwaan 24 bit
Analog Input Channels 1 channel
Input Architecture Differential
Conversion Rate 600 samples per second
Power Consumption 125 mW
Packhaging 24-lead SOIC
Input Range 0 mV to ±10 mV, ±20 mV, ±40 mV, and ±80 mV
Bipolar Input Ranges ±10 mV, ±20 mV, ±40 mV, and ±80 mV
Offset Drift Less than 5 nV/°C
Gain Drift Less than 3 ppm/°C
Calibration Features Self-calibration and system calibration
Hanay ng Temperature na Operasyon -40°C to +85°C
Temperature Grade Industrial
Output Interface Serial

Gabay sa Pin Configuration ng AD7730LBR 24-lead soic

Pin configuration para sa AD7730LBR (24-lead soic package). Ang analog component na ito ay may input, output, at power supply pins. Sumangguni sa datasheet ng manufacturer para sa offset null, compensation, at enable pin configurations. Perpekto para sa signal conditioning at amplifier circuits.

Pinout diagram ng 24-lead soic package para sa AD7730LBR

Wala ng detalyadong pinout data na magagamit para sa AD7730LBR.

Sumangguni sa datasheet para sa buong pin configuration.

Tipikal na mga Gamit

AD7730LBR ay nararapat para sa 6 aplikasyons: Digital Weigh Scales, Load-Cell Pressure Transmitters, Industrial Force and Torque Measurement, Portable Weighing Instruments, Laboratory Precision Balances, Process Pressure Monitoring.

⚡

Digital Weigh Scales

The AD7730LBR fits digital weigh scales because its 24-bit sigma-delta conversion preserves fine resolution from low-level load-cell signals while the approximately 125 mW operating power helps limit system consumption. Its differential input and programmable ranges through ±80 mV allow the same converter family to cover multiple bridge sensitivities. The device also supports self-calibration and system calibration, while offset drift below 5 nV/°C and gain drift below 3 ppm/°C support stable readings as the structure warms or ambient temperature changes. In a production instrument, the bridge excitation should remain low-noise and stable, and the digital-filter settling time should be included in the weighing cycle.

🏭

Load-Cell Pressure Transmitters

The AD7730LBR is appropriate for pressure transmitters that use a resistive bridge and require direct differential measurement. Its 24-bit resolution can resolve small millivolt-level changes, while selectable unipolar and bipolar ranges allow the interface to match transducer sensitivity. The low-power AD7730L construction is useful in transmitters with limited thermal budget, and its specified gain drift below 3 ppm/°C supports measurement stability. The bridge excitation, reference voltage, sensor wiring, and converter input must share a careful grounding strategy so injected excitation noise does not obscure the small differential signal.

🏭

Industrial Force and Torque Measurement

Force cells and torque transducers commonly produce small differential outputs, making the AD7730LBR’s 24-bit input converter useful for industrial force-measurement equipment. Programmable input spans extending to ±80 mV provide design flexibility across different bridge sensitivities, and the 600 samples-per-second class of operation can support controlled static-force measurements. The converter’s low power also reduces the thermal burden in compact instrumentation. Calibration should be performed with the final mechanics and load path because deflection, mounting stress, and sensor self-heating can influence the end-to-end result beyond the converter specification.

📱

Portable Weighing Instruments

The AD7730LBR suits portable scales where converter power contributes directly to battery life. Its approximately 125 mW operating power and lower-power AD7730L architecture support an instrument that must maintain 24-bit measurement resolution without the demand of the standard AD7730. The differential input reduces sensitivity to common-mode voltage, while programmable ranges permit adaptation to different load cells. In a portable product, include the converter, display, excitation regulator, and wireless interface in the complete power budget, and verify that the selected digital filter settles within the desired measurement response time.

🔬

Laboratory Precision Balances

The AD7730LBR can serve as the measurement front end in laboratory balances that require repeatable readings from a low-level bridge sensor. Its 24-bit resolution, selectable input ranges, and calibration functions provide a strong base for high-resolution force or mass measurement. The low-power architecture is beneficial when the balance includes multiple measurement channels or extensive display and communications electronics. Layout quality is especially important: keep the bridge excitation return and differential input route compact, maintain symmetry between input conductors, and isolate switching regulators to prevent converter noise from appearing as unstable balance readings.

🔧

Process Pressure Monitoring

The AD7730LBR is suitable for process-pressure monitoring equipment that incorporates a bridge-based pressure sensor and requires a compact, low-power measurement channel. Programmable input ranges support different transducer sensitivities, while the 24-bit conversion architecture helps preserve small pressure-related changes in the sensor output. The specified offset and gain drift limits reduce temperature sensitivity in industrial cabinets. The complete instrument should still include sensor excitation regulation, electrical isolation where required, surge protection, and calibration procedures because the converter alone does not address those protection and safety functions.

What is the AD7730LBR?
The AD7730LBR is a low-power, 24-bit sigma-delta analog front end for bridge transducers and precision measurement systems. According to the Analog Devices AD7730/AD7730L datasheet, it combines a differential analog input with digital conversion and filtering, operates at up to 600 samples per second, and is packaged in a 24-lead SOIC. It is particularly suited to weigh scales, load cells, pressure sensors, and other systems that produce small differential output voltages.
What are the key specifications of AD7730LBR that engineers should know?
The AD7730LBR combines 24-bit resolution, one differential input channel, a 600 samples-per-second conversion rate, approximately 125 mW power consumption, and a 24-lead SOIC package. According to Analog Devices product information, it supports programmable unipolar and bipolar input ranges extending to ±80 mV. Offset drift is specified below 5 nV/°C, gain drift below 3 ppm/°C, and self-calibration and system-calibration functions are available.
Where can I download the AD7730LBR datasheet PDF?
The official AD7730/AD7730L datasheet PDF is available from Analog Devices at the manufacturer documentation link on this page. It is the appropriate document for confirming pin assignments, input-range tables, calibration procedures, digital-interface timing, and recommended application circuits. The AD7730L product page also provides a separate overview of the low-power converter family. Use the ordering table in the manufacturer documentation to verify the exact AD7730LBR package and temperature-grade configuration.
Where can I find the AD7730LBR pinout?
The AD7730LBR pinout is shown in the pin-configuration and pin-description sections of the Analog Devices AD7730/AD7730L datasheet. The converter uses a 24-lead SOIC package, and the same data sheet also defines the serial interface, analog inputs, reference input, supply pins, and control connections. Use that table when assigning PCB nets because the exposed package configuration and function names must be checked against the exact datasheet revision before layout release.
Is AD7730LBR suitable for load-cell and weigh-scale applications?
Yes, the AD7730LBR is specifically designed for bridge-transducer measurements such as load cells and weighing systems. Its 24-bit resolution captures low-level differential signals, while programmable input ranges cover unipolar and bipolar spans through ±80 mV. The manufacturer lists self-calibration and system-calibration support, offset drift below 5 nV/°C, and gain drift below 3 ppm/°C, making it appropriate for stable high-resolution industrial measurements.
What is the difference between AD7730LBR and AD7730BRZ?
The AD7730LBR is the low-power AD7730L variant, while AD7730BRZ is the standard AD7730 family member. Analog Devices describes AD7730L as consuming approximately one-third the power of AD7730. The cross-reference information also identifies a broader temperature range for AD7730LBR, from -40°C to +85°C, compared with 0°C to +70°C for AD7730BRZ. Both use the same 24-lead SOIC architecture, but final qualification should include power, timing, and temperature verification.
When should I choose AD7730LBR over AD7730BRZ?
Choose AD7730LBR when converter power is a primary constraint or when operation across -40°C to +85°C is required. The AD7730L family consumes approximately one-third the power of AD7730, making it attractive for portable scales, distributed sensors, and lower-power industrial instruments. Choose AD7730BRZ when the standard AD7730 performance and its 0°C to +70°C specified range are sufficient and the lower-power AD7730L is unnecessary.
Is AD7730LBR suitable for industrial pressure measurement?
The AD7730LBR is suitable for industrial pressure measurement when the bridge transducer output remains within the selected input range. Its programmable spans extend to ±80 mV, and the low-noise 24-bit conversion architecture is appropriate for extracting small changes from resistive-bridge sensors. Offset drift below 5 nV/°C and gain drift below 3 ppm/°C help preserve accuracy as temperature varies. Mechanical pressure range, excitation voltage, safety requirements, and system calibration should still be evaluated at the complete instrument level.
What can replace AD7730LBR?
AD7730BRZ is the closest verified same-family drop-in candidate for AD7730LBR because it uses the same 24-lead SOIC package and pin arrangement. The principal differences are power consumption and temperature grade: AD7730LBR is the approximately one-third-power variant and supports -40°C to +85°C, whereas AD7730BRZ supports 0°C to +70°C. No cross-brand pin-to-pin replacement was confirmed, so board changes should not be assumed without manufacturer documentation.
Can AD7730BRZ replace AD7730LBR without PCB changes?
AD7730BRZ can serve as a pin-compatible 24-lead SOIC substitute for AD7730LBR, subject to system-level verification. The confirmed differences are that AD7730LBR is the low-power version, consuming approximately one-third the AD7730 power, while AD7730BRZ has a 0°C to +70°C specified range rather than -40°C to +85°C. Check startup behavior, conversion timing, calibration method, supply current, and the operating-temperature envelope before approving the substitution.
Is there a verified cross-brand drop-in equivalent for AD7730LBR?
No verified cross-brand, pin-to-pin drop-in equivalent for AD7730LBR was identified. Other high-resolution converters proposed for bridge measurement may use different packages, interfaces, reference arrangements, excitation limits, or gain structures, so they cannot be treated as drop-in replacements without a full PCB and specification review. The documented AD7730BRZ option remains the closest same-package candidate. Request engineering confirmation through the Request a Quote form if a second-source arrangement must preserve the existing land pattern.
Where can I buy AD7730LBR and what is its current lead time?
Use the Request a Quote form on this page to request AD7730LBR availability, current lead time, and order confirmation. Quote requests can also specify the required quantity and reel format, allowing procurement to match the exact AD7730LBR ordering code. Do not treat an unconfirmed distributor listing as a stock guarantee; the manufacturer product page identifies the AD7730L family as production, while allocation and delivery timing should be confirmed for the current order.
What is the price of AD7730LBR?
The current AD7730LBR price should be obtained through the Request a Quote form on this page because commercial terms can change with quantity, date, and packaging configuration. The form is the appropriate route for a quotation tied to the exact AD7730LBR ordering code rather than a family-level starting price. Specify reel quantity, delivery destination, and required production quantity so the returned commercial offer reflects the actual sourcing requirement.
Is AD7730LBR in stock?
AD7730LBR inventory should be confirmed through the Request a Quote form on this page for the quantity and delivery date needed. Analog Devices identifies the AD7730L as a production device, but production status does not by itself guarantee current stock at every quantity or packaging format. A quotation response can confirm available inventory, expected lead time, and shipment planning information for the exact MPN before you place the order.
How should AD7730LBR be designed for low-noise bridge measurements?
Use a stable bridge excitation and reference, route the differential input as a short matched pair, and place input filtering close to the AD7730LBR. Select the narrowest input range that accommodates the transducer’s full-scale output without clipping, then use self-calibration and system calibration to remove offset and gain errors. Because the converter is delta-sigma based, digital-filter settling time must be included in the measurement cycle. Keep switching converters and high-current paths physically separated from the bridge and analog input traces.

Impormasyon ng Talumpati sa Engineering for AD7730LBR — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.

Paunawang Hanapin

Choose AD7730LBR when the design uses a bridge transducer and benefits from 24-bit resolution, 600 samples-per-second conversion, calibration functions, low power consumption, or operation across -40°C to +85°C. It is especially appropriate for portable scales and compact industrial pressure or force instruments where converter power contributes to the overall thermal budget. Choose AD7730BRZ when the same 24-lead SOIC pin arrangement is useful but the standard AD7730 power consumption is acceptable and the required operating range remains within 0°C to +70°C. The two parts can share a PCB footprint, but the power and temperature differences must be included in qualification. No verified cross-brand drop-in option was identified, so changing manufacturers may require a different package, interface, or application-circuit review rather than a simple substitution.

Ikabit sa Mga Alternatibo

Parametro Ito ang Producto AD7730BRZ
Package 24-lead SOIC 24-lead SOIC
Brand Analog Devices Analog Devices
Converter Architecture 24-bit sigma-delta ADC 24-bit sigma-delta ADC
Analog Input Channels 1 channel 1 channel
Input Type Differential Differential
Conversion Rate 600 samples per second 600 samples per second
Power Class Low-power AD7730L, approximately one-third AD7730 power Standard AD7730 power class
Operating Temperature Range -40°C to +85°C 0°C to +70°C
Calibration Support Self-calibration and system calibration Self-calibration and system calibration
Output Interface Serial Serial

Pangunahing mga Pagkakaiba

  • Lower power for portable and distributed measurement (kumpara saAD7730BRZ)
  • Wider specified temperature coverage (kumpara saAD7730BRZ)
  • Direct bridge-transducer measurement architecture (kumpara saAD7730BRZ)

Talaan ng Disenyo

Route the differential bridge input as a short, symmetric pair directly to the converter pins. Keep the bridge excitation and reference routing physically separate from the input path, use a continuous ground reference beneath the analog section, and place optional input filtering close to AD7730LBR pins. These steps reduce conversion of switching and excitation noise into differential error and help preserve the benefit of the 24-bit conversion architecture.

Use the manufacturer-recommended supply and reference arrangement, and verify that the bridge excitation remains stable over the required measurement range. Because AD7730L is designed to operate at approximately one-third the power of AD7730, its lower consumption should be included in the complete thermal and battery budget rather than estimated from the ADC alone. Confirm the selected input range cannot clip the largest expected transducer output, including tolerance, temperature drift, and calibration margin.

Do not treat 24-bit resolution as useful accuracy unless noise, reference stability, mechanical error, and calibration are controlled. Include digital-filter settling time in every measurement cycle, perform self-calibration and system calibration after installation, and avoid selecting the AD7730BRZ substitute when the system must operate below 0°C or above 70°C. AD7730BRZ also changes the converter from the low-power AD7730L class to the standard AD7730 power class.

Impormasyon ng Pagsunod sa Kautusan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Walang Lead
Unknown
Walang Halogen
Unknown
Mga Conflict Mineral
Unknown

No explicit environmental or automotive qualification statements were identified for AD7730LBR in the manufacturer pages and product information available for this record.

Data napatotohanan sa: 2026-11-26 — impormasyon na pinatunayan at pinapatakbo ng pangkat ng engineering ng XAIPART's component engineering team

Kaugnay na Hanapin

AD7730LBR AD7730LBR datasheet AD7730LBR datasheet pdf AD7730LBR pinout AD7730LBR equivalent AD7730LBR replacement AD7730LBR cross reference AD7730LBR vs AD7730BRZ AD7730LBR price AD7730LBR stock Analog Devices AD7730LBR AD7730L 24-SOIC pinout

Mga kaugnay na Mga Komponente at mga Tuntunin

Analog Devices AD7730LBR AD7730L AD7730BRZ 24-bit ADC sigma-delta converter analog front end bridge transducer load cell pressure sensor weigh scale differential input programmable gain self-calibration system calibration offset drift gain drift 24-lead SOIC SOIC family surface-mount package industrial instrumentation power management IC 600 samples per second
Mabilis na Tanggap na RFQ
Ihanda ang buong detalye — ang aming pangkalakal na koponan ay tutugon sa loob ng 24 oras
Numero ng Parte Mga Tagagawa Pakete QTY Target na Halaga Pinalawak
✓
Quote na inilabas!

Ating tumugon sa iyong email sa loob ng 24 oras

1
RFQ Naisumite
2
Received na ang Kwaliksik
3
Nai-order
4
Pagbabayad
5
Inihanda
6
Naihanda
Tingnan ang Detalye ng RFQ