CD4026AF/3 - 4-Bit Decade Counter | Texas Instruments
MPN: CD4026AF/3 ✓ NakahandaCD4026AF/3 Ulas
A decade counter is a sequential digital-logic component that advances through ten states for every ten input-clock cycles. Positioned within the hierarchy of counters, counters, dividers, CMOS logic ICs, and semiconductors, the CD4026AF/3 is intended for frequency division, event counting, and display sequencing. Its 10 decoded outputs allow one output to be active for each of the ten count states.
The principal system features are the 16-pin DIP package, decade-counting function, 10 decoded outputs, and carry output. The DIP-16 package supports through-hole PCB assembly and conventional socket-based prototyping. Because the CD4026AF/3 is a static CMOS counter, its clock, reset, inhibit, carry, and decoded-output functions provide a compact way to implement decimal sequencing without assembling a counter from individual gates.
The CD4026 family is used where a counter must divide an input frequency by ten or translate a count into a one-of-ten output pattern. The carry terminal allows additional counting stages to be cascaded when more than ten states are required. Designers should also account for propagation delay when the counter output must align with high-speed clocks, and should verify the operating voltage, timing limits, and output-drive requirements against the manufacturer datasheet before finalizing a design.
Typical uses include digital frequency dividers, decade sequencing circuits, seven-segment display drivers, pulse counters, clock dividers, and industrial control panels. The ten decoded outputs are especially useful for driving a display decoder when a system requires decimal count information rather than a conventional four-bit binary bus.
For a new PCB, place the CD4026AF/3 according to the manufacturer pinout and route all unused inputs to a defined logic level. Add supply decoupling close to the device, use a consistent reset strategy, and confirm that the clock source satisfies the device's maximum transition requirements. A socket can simplify prototype replacement, but production assemblies normally use the DIP device directly.
This page combines the manufacturer and distributor product information with practical pin-assignment, cascading, display-decoding, and counter-design guidance. It also separates confirmed product attributes from parameters that require confirmation in the manufacturer datasheet, helping engineers move from component selection to PCB implementation with fewer unresolved design questions.
Mga alternatibo na pwedeng ilagay na CD4026AF/3 — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.
Variante sa Seri na ito
Katulad na modelo sa serye na katugma sa pagpasok CD4026AF/3 (parehas na form factor at footprint) — pagkakaiba sa Mounting Type, Counter Architecture, Package, RoHS Status.
CD4026AF
✅ Drop-In ⚠️ Mga Talaan Hindi Naiwerikmo📋 Alternatibo na Reference (hindi sa katalogo)
CD4026AE
✅ Drop-In ⚠️ Mga Talaan Hindi Naiwerikmo📋 Alternatibo na Reference (hindi sa katalogo)
CD4026BE
✅ Drop-In ⚠️ Mga Talaan Hindi NaiwerikmoMagkontak para sa presyo
Tingnan ang Datasheet →CD4026BF
✅ Drop-In ⚠️ Mga Talaan Hindi NaiwerikmoMagkontak para sa presyo
Tingnan ang Datasheet →CD4026BM
✅ Drop-In ⚠️ Mga Talaan Hindi Naiwerikmo📋 Alternatibo na Reference (hindi sa katalogo)
CD4026AF/3 Mga Pinakamataas na Rating at Electrical Characteristics
| Logic Type | 4-bit decade counter and divider |
| Counting Sequence | 0 to 9 |
| Decoded Outputs | 10 outputs |
| Packhaging | DIP-16 |
| Bilang ng Pin | 16 pins |
| Uri ng Pagpapasok | Through-hole |
| Reset Function | Static operation with reset function |
| Tindminan RoHS | Compliant |
Pin Configuration ng CD4026AF/3
| Pin 1 | CLK — Clock input |
| Pin 2 | CLK INH — Clock inhibit input |
| Pin 3 | RESET — Reset input |
| Pin 4 | Q0 — Decoded output 0 |
| Pin 5 | Q1 — Decoded output 1 |
| Pin 6 | Q2 — Decoded output 2 |
| Pin 7 | Q4 — Decoded output 4 |
| Pin 8 | VDD — Positive supply |
| Pin 9 | Q3 — Decoded output 3 |
| Pin 10 | Q5 — Decoded output 5 |
| Pin 11 | Q6 — Decoded output 6 |
| Pin 12 | Q7 — Decoded output 7 |
| Pin 13 | Q8 — Decoded output 8 |
| Pin 14 | Q9 — Decoded output 9 |
| Pin 15 | VSS — Ground |
| Pin 16 | CARRY — Carry output for cascading |
Tipikal na mga Gamit
CD4026AF/3 ay nararapat para sa 6 aplikasyons: Digital Frequency Divider, Seven-Segment Display Sequencing, Industrial Pulse Counter, Sequential Control Logic, Timing and Clock Generation, Educational and Prototype Logic.
Digital Frequency Divider
The CD4026AF/3 is appropriate when an input clock must be divided into a decimal-rate output. Its decade-counter function advances through 10 count states, while the carry output provides a convenient divide-by-10 signal for a following stage. This arrangement can support timing dividers, pulse-rate reduction, and periodic event generation in equipment operating from a common clock. Because the device is packaged in a 16-pin DIP format, it is especially convenient for through-hole prototypes and repairable industrial assemblies. Confirm the maximum operating clock frequency, propagation delay, and supply-voltage range in the manufacturer datasheet before setting the input frequency. Place a local supply-decoupling capacitor close to the device, provide a defined reset state at startup, and leave the clock-inhibit input at a valid inactive level so the counter advances deterministically.
Inirekomenda
Seven-Segment Display Sequencing
The CD4026AF/3 fits decimal display sequencing because its 10 decoded outputs identify the 10 count states. Those outputs can feed a compatible seven-segment decoder, allowing a counter and display subsystem to show changing decimal values without decoding a conventional four-bit binary bus. The DIP-16 package supports socketed prototyping and straightforward through-hole assembly. The display decoder must have compatible logic polarity, and the counter outputs must not be asked to source the LED segment current directly; use a suitable display driver where required. Timing between the clock edge and decoded output must be checked against the decoder's input setup and hold requirements. Resetting the counter to a defined state during startup prevents an unpredictable initial display, and supply bypassing close to the IC helps prevent display-current transients from disturbing the counting logic.
Inirekomenda
Industrial Pulse Counter
The CD4026AF/3 can count recurring input pulses and expose the count through its decoded outputs, making it suitable for event-counting modules, production equipment, and simple process-cycle indicators. A decade count provides a natural interface for selecting one of ten machine states without requiring a microcontroller to decode every transition. The device's 16-pin DIP package is practical for legacy control boards, test fixtures, and field-serviceable equipment. Use filtering or conditioning ahead of the clock input when contacts, relays, or long cables can introduce bounce or unwanted transitions. The clock-inhibit function can be used to pause counting during an invalid event, while reset establishes a repeatable starting state. Verify input rise and fall times, supply range, and environmental ratings before deploying the counter in industrial machinery.
Inirekomenda
Sequential Control Logic
The CD4026AF/3 can implement one-of-ten sequencing in legacy automation and control circuits. Each decoded output represents one step in the sequence, allowing lamps, relays, or control inputs to be selected after successive clock pulses. A cascaded arrangement can extend the sequence beyond 10 stages by feeding the carry output into another counter. The DIP-16 package is useful when a through-hole footprint already exists or when socketed maintenance is preferred. Design reset and inhibit controls to fail in a defined state, and ensure that connected relay or lamp interfaces include suitable drive components because the counter is a logic device rather than a power-output stage. Validate timing margins against the slowest sequence transition and use local decoupling to keep supply disturbances from producing false count changes.
Inirekomenda
Timing and Clock Generation
The CD4026AF/3 can act as a decimal divider within a larger timing chain, with the carry output providing a lower-frequency reference for another logic block. It is useful in legacy timing modules, test equipment, and control systems that need a divide-by-10 stage without a programmable clock generator. Because the counter operates synchronously with its clock family, stage-to-stage timing depends on the propagation delay of the counter and the receiving device. Verify maximum clock frequency and setup-time requirements in the manufacturer datasheet, particularly when operating near the upper timing limit. Keep clock traces short and use a stable ground reference to minimize susceptibility to noise-induced false transitions. A pull resistor or defined driver state may be needed on unused control inputs to prevent floating-node behavior.
Inirekomenda
Educational and Prototype Logic
The CD4026AF/3 is a practical component for breadboard and through-hole educational designs that demonstrate decade counting, decoded outputs, reset behavior, and carry cascading. Its DIP-16 package is easy to inspect, socket, and replace, while the ten decoded outputs make the internal count state visible without a logic analyzer. Students can use it to build digital clocks, step selectors, traffic-light sequences, and divide-by-ten demonstrations. For reliable prototype operation, power it from a regulated source, connect ground consistently, and add bypass capacitance near the supply pins. Avoid leaving the clock input floating and briefly exercise reset during startup so the displayed count begins at a known state. For timing demonstrations, keep the signal generator leads short and use a common ground to prevent false triggering caused by ground-loop or reference-voltage differences.
Inirekomenda
Buod ng mga Inirekomendang Produkto
Impormasyon ng Talumpati sa Engineering for CD4026AF/3 — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.
Paunawang Hanapin
Ikabit sa Mga Alternatibo
| Parametro | Ito ang Producto | CD4026AF | CD4026AE | CD4026BE | CD4026BF | CD4026BM |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | DIP-16 | DIP-16 | DIP-16 | DIP-16 | DIP-16 | DIP-16 |
| Counter Type | 4-bit decade counter | 4-bit decade counter | 4-bit decade counter | 4-bit decade counter | 4-bit decade counter | 4-bit decade counter |
| Decoded Outputs | 10 | 10 | 10 | 10 | 10 | 10 |
| Pin Count | 16 pins | 16 pins | 16 pins | 16 pins | 16 pins | 16 pins |
| Mounting Type | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole |
Pangunahing mga Pagkakaiba
- Provides decimal decoded outputs rather than only a binary count bus (kumpara saCD4026BE)
- Includes a carry output for modular counting (kumpara saCD4026AF)
- Supports a practical through-hole implementation (kumpara saCD4026AE)
- Combines counting, division, and one-of-ten selection (kumpara saCD4026BM)
Talaan ng Disenyo
Place the CD4026AF/3 in the same DIP-16 position used by the original design and route the clock, inhibit, reset, carry, and decoded-output signals according to the manufacturer pin-description table. Keep the clock trace short, provide a common ground reference, and place the supply-bypass capacitor close to the VDD and VSS pins. Avoid long parallel runs between adjacent decoded outputs because switching current in these lines can couple into the clock and produce an incorrect count.
Do not leave the clock, clock-inhibit, or reset inputs floating. Drive reset to a defined startup state so the count does not begin from an unknown value, and connect unused inputs to a valid inactive logic level. For switches or relay contacts feeding the clock, add debounce or conditioning so contact bounce is not interpreted as multiple counts. Also use a separate driver for lamps and displays rather than sourcing their current directly from the decoded outputs.
Verify the clock's rise and fall times, maximum operating frequency, and the decoded-output transition timing against the manufacturer datasheet. When cascading counters, check the carry pulse width and setup time at the next stage rather than assuming it remains valid at the highest clock rate. Keep the clock source referenced to the same ground as the counter and avoid routing it near relay-coil or switching-supply return paths.
The CD4026AF/3 is a CMOS logic IC, so supply decoupling and clean power are central to reliable counting. Place the manufacturer's recommended bypass capacitor adjacent to the supply pins, maintain a low-impedance ground connection, and account for transients generated by display or relay loads connected to the board. Confirm the allowed supply range and output current in the manufacturer datasheet before adding load-driving circuitry to the decoded or carry outputs.
Impormasyon ng Pagsunod sa Kautusan
RoHS-compliant status is identified in the JLCPCB product listing. No qualification, lead-free, halogen-free, REACH, or conflict-minerals statement is confirmed for the exact suffix.