Cirrus Logic Inc.

CS5509-AP - 16-Bit 2-Input Sigma-Delta ADC | Cirrus Logic

MPN: CS5509-AP ✓ Nakahanda
Single supply Vdss 16-PDIP Package
MOQ: 1 |

CS5509-AP Ulas

Cirrus Logic CS5509-AP is a single-supply, 16-bit analog-to-digital converter with two analog inputs and a one-channel sigma-delta architecture, housed in a 16-pin PDIP package. It is intended for precision measurement systems that convert low-bandwidth, differential or single-ended sensor signals into high-resolution digital data.

An ADC is an interface IC that samples an analog voltage and converts it into a numeric value for processing, measurement, or control. A sigma-delta ADC belongs to the class of mixed-signal converters that use continuous-time oversampling and digital filtering to achieve fine resolution. The CS5509-AP combines that conversion technique with a single-supply architecture, allowing it to operate from one supply rail in compact industrial, instrumentation, and embedded measurement equipment.

The manufacturer identifies the device as a 16-bit converter with two analog inputs and a sigma-delta conversion system. Its dual-input arrangement allows a board to measure more than one analog quantity or use differential measurement when the circuit configuration requires it. Single-supply operation can also simplify signal-chain design by reducing the number of rails needed around the converter, although the supported supply range and input limits must be confirmed in the manufacturer datasheet before final component selection.

The sigma-delta architecture is particularly useful when high nominal resolution and narrow-band measurement accuracy matter more than very high conversion speed. Such converters commonly use an external or internal reference, an analog input stage, a modulator, a digital decimation filter, and a serial interface. Exact filter characteristics, output rates, digital interface modes, and calibration behavior for the CS5509-AP should be taken directly from the applicable Cirrus Logic datasheet.

Typical uses include industrial process monitoring, low-level sensor acquisition, laboratory instrumentation, and embedded measurement modules. In these systems, the CS5509-AP serves as the bridge between an analog sensor front end and a microcontroller or other digital controller. Designers should pay particular attention to the reference voltage, input common-mode range, analog input filtering, grounding, and the acquisition timing associated with the selected output data rate.

For layout, keep the analog input and reference paths short, use a clean low-noise supply, and follow the manufacturer guidance for bypassing and grounding. Because the package is a through-hole PDIP rather than a fine-pitch surface-mount option, it is especially practical for prototypes, educational designs, and moderate-volume industrial assemblies where insertion or socketed assembly is acceptable.

This page consolidates the confirmed device identity, package, converter type, sourcing links, technical design guidance, and application-selection context into one engineering-oriented resource for evaluating the CS5509-AP.

Mga alternatibo na pwedeng ilagay na CS5509-AP — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.

Wala ng magagamit na drop-in alternatibo para sa produkto na ito.

Hilingin ang Alternatibo

CS5509-AP Mga Pinakamataas na Rating at Electrical Characteristics

Product Type Analog-to-Digital Converter (ADC)
Manufacturer Cirrus Logic
Pangangasiwaan 16 bit
Analog Input Count 2 inputs
Conversion Architecture 1 sigma-delta
Supply Type Single supply
Packhaging 16-PDIP
Style ng Pagpapasok Through-hole

Gabay sa Pin Configuration ng CS5509-AP 16-pdip

Pin configuration para sa CS5509-AP (16-pdip package). Ang analog component na ito ay may input, output, at power supply pins. Sumangguni sa datasheet ng manufacturer para sa offset null, compensation, at enable pin configurations. Perpekto para sa signal conditioning at amplifier circuits.

Pinout diagram ng 16-pdip package para sa CS5509-AP

Wala ng detalyadong pinout data na magagamit para sa CS5509-AP.

Sumangguni sa datasheet para sa buong pin configuration.

Tipikal na mga Gamit

CS5509-AP ay nararapat para sa 6 aplikasyons: Industrial Process Measurement, Precision Sensor Acquisition, Laboratory Instrumentation, Environmental Monitoring, Data Acquisition Modules, Educational Electronics Projects.

🏭

Industrial Process Measurement

The CS5509-AP is suitable for acquiring slow-changing process variables such as pressure, temperature, level, or slow pressure-transducer outputs. Its 16-bit sigma-delta architecture is appropriate when the measurement bandwidth is narrow and high nominal resolution is more valuable than rapid sampling. The two analog inputs allow a board to acquire more than one conditioned signal when the converter configuration supports it. At the board level, provide anti-alias filtering, a low-noise reference, local supply bypassing, and careful grounding around the 16-PDIP device. Confirm the converter’s exact input and common-mode limits before scaling a transmitter output.

🧩

Precision Sensor Acquisition

The CS5509-AP fits low-level sensor front ends where a bridge, resistive sensor, or transducer produces a narrow-band analog signal that must be digitized accurately. Its 16-bit conversion resolution provides a suitable starting point for precision measurement, while the sigma-delta architecture supports digital filtering of out-of-band noise. The circuit should condition the sensor close to the ADC so that the two analog inputs, reference network, and return path remain free of high-energy switching nodes. Verify input range, common-mode voltage, and conversion timing in the Cirrus Logic datasheet before selecting amplifier and filter values.

🔧

Laboratory Instrumentation

The CS5509-AP can serve as the measurement converter in laboratory instruments that monitor slow or narrow-band analog quantities. Examples include bench power supplies, environmental analyzers, and precision measurement interfaces where the desired result is a stable digital reading rather than a high-rate waveform. The 16-bit resolution supports detailed measurement, and the two inputs can provide convenient signal monitoring when the application only requires low-bandwidth data. Use shielded analog routing, a clean reference, and deliberate digital filtering, and verify the output-data rate against the instrument’s required settling time and display-update cycle.

🧩

Environmental Monitoring

The CS5509-AP is appropriate for environmental monitoring modules that measure slow analog signals from gas, humidity, pressure, or water-level sensors. These applications generally favor resolution and stable readings over rapid conversion, matching the sigma-delta approach of the device. Both analog inputs can be useful for monitoring a primary environmental quantity and a secondary reference or status channel. Design the front end with sensor-specific filtering, protection appropriate to the measured environment, and ground planes that prevent converter current from sharing a path with sensitive sensor returns. Confirm operating-temperature and environmental qualification requirements separately.

🖥️

Data Acquisition Modules

The CS5509-AP can be used in compact data-acquisition modules intended to digitize narrow-band sensor channels for a controller or host processor. Its 16-bit resolution and two-input configuration make it useful when each channel changes slowly and the system emphasizes measurement accuracy over acquisition throughput. Place the converter close to the analog connector and protection network to minimize noise pickup, while keeping its digital interface away from sensitive analog traces. The complete design should verify serial-interface timing, output-code format, reference requirements, and the conversion sequence needed by the host processor.

💡

Educational Electronics Projects

The CS5509-AP is well suited to university laboratories and educational analog-measurement projects because it combines a 16-bit sigma-delta converter with a through-hole 16-PDIP package. The package is straightforward to place on a prototype board, and the dual analog inputs support experiments involving sensor conditioning, filtering, reference stability, and digital acquisition. Students can compare the measured code with known input voltages and examine how filtering and noise affect accuracy. Use the manufacturer pinout and reference circuit for every connection, and treat the experiment as a learning platform rather than a substitute for production-grade protection or qualification.

What is the CS5509-AP?
The CS5509-AP is a Cirrus Logic single-supply, 16-bit analog-to-digital converter with two analog inputs and a sigma-delta conversion architecture. The manufacturer datasheet describes it as a single-supply 16-bit A/D converter, while the 16-PDIP package supports through-hole PCB assembly. It is best suited to precision, relatively narrow-bandwidth measurement rather than high-speed waveform acquisition.
What are the key specifications of CS5509-AP that engineers should know?
The CS5509-AP is a 16-bit, two-input, single-supply sigma-delta ADC in a 16-PDIP package. Its resolution, dual-input capability, and narrow-band-oriented sigma-delta architecture are the principal engineering facts confirmed by the Cirrus Logic datasheet and distributor listings. Supply limits, reference voltage, conversion rate, and interface timing require confirmation in the manufacturer datasheet for a specific implementation.
Where can I find the CS5509-AP pinout?
Use the pin-description table and package drawing in the Cirrus Logic CS5509-AP manufacturer datasheet to assign PCB connections. The confirmed package is 16-PDIP, but the individual pin names and electrical functions are not reproduced on this page. A public datasheet landing page is available at https://www.alldatasheet.com/datasheet-pdf/pdf/85316/CIRRUS/CS5509-AP.html for the complete connection information.
Where can I download the CS5509-AP datasheet PDF?
The CS5509-AP datasheet is accessible through the Cirrus Logic documentation link at https://www.alldatasheet.com/datasheet-pdf/pdf/85316/CIRRUS/CS5509-AP.html. It describes a single-supply, 16-bit A/D converter and provides the authoritative information for pin assignments, electrical characteristics, timing, and application use. Confirm the complete document and its revision against the manufacturer before releasing a production design.
Is the CS5509-AP suitable for sensor measurement?
Yes, the CS5509-AP is suitable for many low-bandwidth precision sensor-measurement applications. Its 16-bit sigma-delta conversion system is designed to resolve slowly changing or narrow-band analog signals, and its two analog inputs can serve a multichannel or differential front end. The input range, common-mode limits, noise, and output rate must match the sensor signal before the converter is selected.
Can CS5509-AP be used for high-speed sampling?
The CS5509-AP is primarily suited to precision, low-bandwidth acquisition rather than high-speed sampling. Its sigma-delta architecture favors fine conversion resolution and noise filtering for relatively narrow signal bandwidths. For waveform sampling, oscilloscope capture, or other high-rate tasks, compare the required acquisition rate and signal bandwidth against the output-data-rate and conversion timing listed in the Cirrus Logic datasheet.
Where can I buy the CS5509-AP online?
Use the Request a Quote form on this page to request current CS5509-AP availability, minimum order quantity, and delivery terms. The manufacturer part is also listed by several authorized distribution channels, but pricing and inventory change frequently. The confirmed package and suffix matter when requesting a quotation because CS5509-AP denotes the 16-PDIP configuration.
What is the price of the CS5509-AP?
Request a current quotation for the CS5509-AP through the Request a Quote form on this page. A distributor listing shows a starting price, but it does not provide a qualifying quantity-break table for this exact suffix and therefore is not treated as a stable price tier. Your quotation should specify the manufacturer part number CS5509-AP and the required production quantity.
What is the lead time for the CS5509-AP?
Request the current lead time and stock status through the Request a Quote form on this page. The manufacturer datasheet and component listings do not establish a fixed production lead time, and market availability can vary by order quantity. A quantity-based quotation provides the most appropriate confirmation for your assembly schedule.
Is the CS5509-AP in stock?
Stock status for the CS5509-AP should be confirmed through the Request a Quote form on this page. Although several distributor listings identify the device as available or stocked, inventory levels change and may not reflect the quantity or date required by a production order. Include your required quantity, target date, and acceptable purchase-order terms in the request.
What can replace the CS5509-AP?
No verified pin-to-pin drop-in replacement for the CS5509-AP is established by the available technical records. A replacement must match the 16-PDIP footprint, pin functions, supply range, input range, reference behavior, conversion rate, and digital interface—not merely provide a similar resolution. Use the Cirrus Logic datasheet to prepare those criteria when asking a distributor or manufacturer to identify an authorized alternative.
What is the best drop-in replacement for CS5509-AP?
The best drop-in replacement is the exact Cirrus Logic CS5509-AP with unchanged orderable suffix and package, because no technically verified substitute meeting all pin and electrical requirements has been identified. A differently suffixed CS5509-family device should not be assumed interchangeable until its package, pinout, supply limits, and interface behavior match. Use the Request a Quote form when securing additional authentic stock.
When should I choose the CS5509-AP instead of a switching ADC?
Choose the CS5509-AP when the design prioritizes 16-bit nominal resolution, narrow-band signal measurement, and direct conversion from a sensor front end rather than high sampling throughput. A switching ADC may be preferable when conversion latency, high-rate capture, or wide-band signal content dominates. The final choice should follow a comparison of noise, bandwidth, latency, power, and interface requirements.
Is CS5509-AP suitable for industrial process control?
The CS5509-AP can be suitable for industrial process-control measurement when the sensor bandwidth is low and the converter’s electrical limits match the signal chain. Its 16-bit resolution and two analog inputs support precision acquisition, but industrial qualification requirements, operating temperature, isolation, transient protection, and long-term availability must be checked separately. Through-hole assembly also makes it more convenient for prototypes and moderate-volume control boards.
What design details matter most for a CS5509-AP circuit?
Prioritize the analog input range, reference voltage, supply range, grounding, filtering, and output-data timing when designing around the CS5509-AP. Place bypass capacitors close to the supply pins and keep analog input routing short and away from switching nodes. Use the manufacturer reference circuit and pin table because those details define the valid input network and interface connections for this 16-bit sigma-delta ADC.

Impormasyon ng Talumpati sa Engineering for CS5509-AP — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.

Paunawang Hanapin

Choose the CS5509-AP when the design requires a 16-bit, low-bandwidth measurement ADC with two analog inputs, single-supply operation, and a through-hole 16-PDIP package. It is particularly suitable for industrial process signals, precision sensors, laboratory instruments, environmental monitoring, and educational data-acquisition projects. A switching ADC may be a better choice when high sampling rates, wide-band waveform capture, or lower conversion latency dominate the design. No verified drop-in alternative is listed because the available cross-reference results do not establish another device with the same pinout, package, electrical limits, reference behavior, and digital interface. Before replacing the CS5509-AP, compare the package drawing and every pin function, then verify supply voltage, input range, reference requirements, conversion timing, output coding, and digital-interface mode. For new designs, also verify current operating-temperature, compliance, and lifecycle requirements rather than relying only on nominal resolution and converter type.

Ikabit sa Mga Alternatibo

Parametro Ito ang Producto
Product Type 16-bit analog-to-digital converter
Brand Cirrus Logic
Package 16-PDIP
Analog Input Count 2 inputs
Conversion Architecture 1 sigma-delta
Supply Type Single supply
Resolution 16 bit
Mounting Style Through-hole

Talaan ng Disenyo

Keep the analog input traces short, route them away from switching nodes and digital clocks, and place the input-network components close to the converter. The 16-PDIP package provides through-hole access, but lead spacing alone does not compensate for poor analog routing. Use a continuous ground plane where practical and connect analog returns without sharing narrow paths with digital output-current return routes.

Place the required bypass capacitors close to the supply pins and use a low-noise supply path. Confirm the permitted supply and reference voltages in the manufacturer datasheet before selecting regulators or reference components. Grounding and capacitor placement are especially important because measurement error at the 16-bit level can arise from reference instability or supply disturbance even when the converter itself has adequate nominal resolution.

Design an analog anti-alias filter appropriate to the intended signal bandwidth and the converter’s output-data rate. The filter should limit out-of-band energy before the sigma-delta modulator while preserving the measurement signal. Do not infer allowable input swing or common-mode range from generic ADC rules; check those limits against the Cirrus Logic application information and validate the complete front end with representative signals.

Impormasyon ng Pagsunod sa Kautusan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Walang Lead
Unknown
Walang Halogen
Unknown
Mga Conflict Mineral
Unknown

No specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals statement is included in the available component records. AEC-Q100 is not applicable because the ADC is not identified as an automotive-qualified device.

Data napatotohanan sa: 2026-11-05 — impormasyon na pinatunayan at pinapatakbo ng pangkat ng engineering ng XAIPART's component engineering team

Kaugnay na Hanapin

CS5509-AP datasheet CS5509-AP pinout CS5509-AP datasheet pdf CS5509-AP equivalent CS5509-AP replacement CS5509-AP cross reference CS5509-AP price CS5509-AP stock Cirrus Logic CS5509-AP CS5509-AP 16-PDIP pinout CS5509-AP sigma-delta ADC CS5509-AP sensor measurement cs5509 asz

Mga kaugnay na Mga Komponente at mga Tuntunin

Cirrus Logic CS5509-AP CS5509-AS analog-to-digital converter ADC sigma-delta ADC mixed-signal IC interface IC 16-bit resolution two analog inputs single-supply operation 16-PDIP through-hole package industrial process measurement precision sensor acquisition laboratory instrumentation environmental monitoring data acquisition anti-alias filter reference voltage
Mabilis na Tanggap na RFQ
Ihanda ang buong detalye — ang aming pangkalakal na koponan ay tutugon sa loob ng 24 oras
Numero ng Parte Mga Tagagawa Pakete QTY Target na Halaga Pinalawak
✓
Quote na inilabas!

Ating tumugon sa iyong email sa loob ng 24 oras

1
RFQ Naisumite
2
Received na ang Kwaliksik
3
Nai-order
4
Pagbabayad
5
Inihanda
6
Naihanda
Tingnan ang Detalye ng RFQ