DP83822HFRHBT - 10/100 Ethernet PHY, 16kV ESD | Texas Instruments
MPN: DP83822HFRHBT ✓ NakahandaDP83822HFRHBT Ulas
An Ethernet PHY (physical layer device) is the interface IC that sits between a media access controller (MAC) and the physical network medium. In the networking hierarchy, it converts digital MAC frames into analog signals suitable for transmission over twisted-pair copper or optical fiber, handling encoding, line drivers, equalization, and auto-negotiation. The DP83822H family extends the standard DP83822HF with extended temperature range and enhanced ESD robustness for harsh environments.
Key features include MAC interface flexibility through standard MII, RMII, and RGMII, support for 100BASE-TX and 10BASE-Te over standard twisted-pair cable plus fiber-mode operation via an external fiber transceiver, 16-kV system-level ESD protection, and Energy-Efficient Ethernet (EEE), Wake-on-LAN (WoL), and programmable energy-saving modes. Cable diagnostics and a 50-MHz clock output (RMII reference) simplify system design.
Technically, the DP83822H integrates the DSP-based transmit path and adaptive equalizer receiver path required by IEEE 802.3 10/100-Mbps operation, with onboard regulators allowing single-supply design. Its low power consumption suits passively cooled industrial equipment, and pin-to-pin compatibility with TLK105, TLK106, TLK105L, and TLK106L enables drop-in upgrades.
Typical applications include industrial Ethernet nodes and EtherCAT slaves, factory automation PLCs, building automation controllers, and grid infrastructure where extended temperature and ESD robustness are mandatory.
Design consideration: maintain a clean 3.3-V supply with proper magnetics module selection and follow the datasheet layout guidelines for the analog MDI pairs to guarantee IEEE 802.3 compliance and ESD performance.
This page synthesizes verified distributor data, drop-in alternatives within the DP83822/TLK families, and practical design guidance not consolidated in the manufacturer datasheet alone.
Mga alternatibo na pwedeng ilagay na DP83822HFRHBT — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.
Variante sa Seri na ito
Katulad na modelo sa serye na katugma sa pagpasok DP83822HFRHBT (parehas na form factor at footprint) — pagkakaiba sa Package, Cable Diagnostics, Clock Output, MAC Interface, Product Type.
DP83822IRHBT
✅ Drop-InMagkontak para sa presyo
Tingnan ang Datasheet →DP83822IFRHBT
✅ Drop-InMagkontak para sa presyo
Tingnan ang Datasheet →DP83822IRHBR
✅ Drop-InMagkontak para sa presyo
Tingnan ang Datasheet →TLK106
✅ Drop-In📋 Alternatibo na Reference (hindi sa katalogo)
TLK105L
✅ Drop-In📋 Alternatibo na Reference (hindi sa katalogo)
DP83822HFRHBT Mga Spesipikasyon
| Rate ng Data | 10/100 Mbps |
| Number of Ports | 1 |
| MAC Interface | MII, RMII, RGMII |
| Fiber Support | Yes (via external fiber transceiver) |
| ESD Protection | 16 kV |
| Volte ng Pagbibigay | 3.3 V single supply |
| Temperature na Operasyon | -40C to +125C |
| Packhaging | VQFN-32 (RHB), 5.00 mm x 5.00 mm |
| Uri ng Pagpapasok | Surface Mount |
| Energy-Efficient Ethernet (EEE) | Yes |
| Wake-on-LAN (WoL) | Yes |
| Cable Diagnostics | Yes |
| Clock Output | 50-MHz clock out (RMII reference) |
| Auto-Negotiation | Yes (IEEE 802.3) |
| Pin-Compatible Family | TLK105, TLK106, TLK105L, TLK106L, DP83822 series |
Gabay sa Pin Configuration ng DP83822HFRHBT vqfn-32 (rhb), 5.00 mm x 5.00 mm
Pin configuration para sa DP83822HFRHBT (vqfn-32 (rhb), 5.00 mm x 5.00 mm package). Ang pagnunumero ng pin, mga function, at connection diagram ay tinukoy sa datasheet ng manufacturer. Sumangguni dito para sa eksaktong footprint at mga alituntunin sa soldering.
Wala ng detalyadong pinout data na magagamit para sa DP83822HFRHBT.
Sumangguni sa datasheet para sa buong pin configuration.
Tipikal na mga Gamit
DP83822HFRHBT ay nararapat para sa 6 aplikasyons: Industrial Ethernet Nodes / EtherCAT Slaves, PLC and Motor Drive Communications, Grid Infrastructure and Smart Meters, Building Automation and HVAC Controllers, Test and Measurement Instruments, Networked Security and IP Cameras (Fiber Option).
Industrial Ethernet Nodes / EtherCAT Slaves
The DP83822HFRHBT's -40C to +125C extended temperature range and 16-kV ESD robustness directly address the harsh electrical environment of factory automation. TI's cost-optimized EtherCAT slave reference design (dual port, AMIC110-based) demonstrates the part in a high-EMC-immunity industrial Ethernet node. Connected to the MAC via RMII with the integrated 50-MHz clock output, the PHY needs no external oscillator, cutting BOM cost. EEE and programmable sleep modes reduce rail power in sealed, passively cooled control cabinets, while cable diagnostics speed field commissioning of long twisted-pair runs.
Inirekomenda
PLC and Motor Drive Communications
Programmable logic controllers and variable-frequency drives experience wide ambient swings, vibrational cable stress, and high ESD exposure. The DP83822HFRHBT fits because its extended temperature rating matches the -40C to +125C ambient envelope of drive cabinets, and its 16-kV ESD performance tolerates discharge events on shielded Ethernet runs near power electronics. With single 3.3-V supply operation and low active power, it integrates cleanly into existing 3.3-V control rails. MII/RGMII flexibility lets one PHY design serve both MCU-based (MII/RMII) and FPGA-based (RGMII) control platforms without MDI-side redesign.
Inirekomenda
Grid Infrastructure and Smart Meters
Reclosers, feeder monitors, and substation controllers demand components qualified for extended temperature and robust against surge and ESD on long outdoor cable runs. The DP83822HFRHBT's 16-kV ESD rating and -40C to +125C range align with these requirements, and fiber-mode operation via an external fiber transceiver provides galvanic isolation between field equipment and control-room networks - a key advantage of the HF variant. Wake-on-LAN and programmable energy-saving modes lower standby draw in battery-backed installations. Cable diagnostics assist remote fault location on buried or aerial copper spans.
Inirekomenda
Building Automation and HVAC Controllers
Building automation controllers (BACnet/IP, Modbus TCP) are often installed in mechanical rooms where ambient temperatures approach industrial ranges and Ethernet cabling picks up ESD from air-handling equipment. The DP83822HFRHBT provides the -40C to +125C margin and 16-kV ESD robustness needed for these environments while drawing low power in EEE mode during idle network periods - reducing thermal load in sealed wall-mount enclosures. Its RMII mode with integrated 50-MHz clock output simplifies connection to cost-sensitive MCU-based controller SoCs, and pin compatibility with the DP83822I family allows a common PCB for standard- and extended-temperature SKUs.
Inirekomenda
Test and Measurement Instruments
Bench and portable instruments (data loggers, oscilloscopes with LAN, networked sensors) require a low-power, IEEE 802.3-compliant 10/100 PHY with minimal external components. The DP83822HFRHBT suits this space: single 3.3-V supply, integrated 50-MHz RMII clock, and cable diagnostics that double as a field troubleshooting tool. Fiber support in the HF variant allows isolated LXI-style connections in electrically noisy measurement setups. The extended temperature range also covers automotive-grade test racks and outdoor telemetry units that see -40C to +85C or beyond, eliminating a second qualification effort across product lines.
Inirekomenda
Networked Security and IP Cameras (Fiber Option)
Outdoor and perimeter security equipment operates across wide temperature extremes and long cable runs susceptible to surge events. The DP83822HFRHBT's fiber-mode operation via an external fiber transceiver enables media-converter-free isolated links between cameras and network video recorders, while 16-kV ESD robustness withstands discharge on copper drops. Low power with EEE is valuable in PoE-splitter-fed cameras where power budgets are tight. The 5x5 mm VQFN-32 footprint fits compact camera module boards, and the -40C to +125C rating covers unheated enclosures in arctic to desert deployments.
Inirekomenda
Buod ng mga Inirekomendang Produkto
Impormasyon ng Talumpati sa Engineering for DP83822HFRHBT — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.
Paunawang Hanapin
Ikabit sa Mga Alternatibo
| Parametro | Ito ang Producto | DP83822IRHBT | DP83822IFRHBT | DP83822IRHBR | TLK106 |
|---|---|---|---|---|---|
| Package | VQFN-32 (RHB) 5x5 mm | VQFN-32 (RHB) - same | VQFN-32 (RHB) - same | VQFN-32 (RHB) - same | VQFN-32 (RHB) - same |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Data Rate | 10/100 Mbps | 10/100 Mbps | 10/100 Mbps | 10/100 Mbps | 10/100 Mbps |
| MAC Interface | MII, RMII, RGMII | MII, RMII, RGMII | MII, RMII, RGMII | MII, RMII, RGMII | MII, RMII |
| Fiber Support | Yes | No | Yes | No | No |
| Operating Temperature | -40C to +125C | -40C to +85C | -40C to +85C | -40C to +85C | 0C to +70C |
| EEE / WoL Power Saving | Yes | Yes | Yes | Yes | No |
| Cable Diagnostics | Yes | Yes | Yes | Yes | No |
| Role | Extended-temp fiber-capable flagship | Standard-temperature, copper-only | Standard-temperature, fiber-capable | Standard-temperature, full reel | Legacy predecessor |
Pangunahing mga Pagkakaiba
- Extended -40C to +125C temperature range (kumpara saDP83822IRHBT)
- Fiber mode support via external transceiver (kumpara saDP83822IRHBT)
- Modern feature set over legacy TLK106 (kumpara saTLK106)
Talaan ng Disenyo
Follow the TI DP83822 datasheet layout guidelines for the MDI differential pairs: maintain 100-ohm controlled impedance on TXOP/TXON and RXOP/RXON, keep the traces as short and matched as possible, and place the magnetics module (with integrated termination per the datasheet magnetics selection table) close to the PHY. Route the 50-MHz RMII clock output away from MDI pairs to prevent coupling into the analog front end and preserve IEEE 802.3 template margins.
The DP83822HFRHBT runs from a single 3.3-V supply with internal regulation of the core rails. Decouple the VDD pins with a network of 0.1-uF ceramics per the datasheet recommended bypass network, plus bulk capacitance near the device. Do not load internal regulated outputs externally beyond datasheet limits. To achieve full EEE savings, ensure firmware properly configures the EEE and sleep modes via the MDIO/Management interface after link-up.
Migrating from a TLK105/TLK106 design: although pin-to-pin compatible, the DP83822 adds strap options and register maps that differ - review the strap configuration table in the TI datasheet and update PHY initialization code. If your design was laid out for the DP83822I (-85C), substituting the HF variant is safe, but substituting the reverse into a 125C application is not: the I-version lacks the extended temperature range and must not be used above +85C.
Impormasyon ng Pagsunod sa Kautusan
Compliance status not stated in the retrieved web data; confirm RoHS/REACH status on the TI product page or distributor environmental data before ordering.