NXP Semiconductors

MC145017P - Low-Power Ionization Smoke Detector IC | NXP

MPN: MC145017P ✗ Tapus ng Buhay
12 µA Vdss 16-DIP (0.300 inch, 7.62 mm pitch) Package
MOQ: 1 |

MC145017P Ulas

NXP Semiconductors MC145017P is a low-power CMOS ionization smoke detector IC with a temporal-pattern horn driver, a 12 µA supply current, and a 16-pin PDIP package. Designed for use with an external ionization chamber, the device detects smoke, evaluates the chamber signal, and activates an external piezoelectric transducer through its internal horn-driver circuitry. Its operating-temperature range is -10°C to 60°C.

An ionization smoke detector is a safety appliance that uses a radiation-based sensing chamber to identify airborne smoke particles. The MC145017 belongs to the sensor and detector interface hierarchy: it accepts an analog signal from the ionization chamber, applies internal detection logic, and controls a piezoelectric alarm. This architecture allows the sensitive ionization chamber, resistive components, and acoustic transducer to remain separate from the monolithic CMOS control circuit.

The principal features of the MC145017P include very low 12 µA supply current, CMOS construction, an ionization-sensor input, a voltage output, and a temporal-pattern horn driver for an external piezoelectric transducer. Low supply current is important in battery-operated alarm systems because the detector electronics and sensing chamber must maintain useful standby and alarm performance without imposing excessive load on the backup battery.

The MC145017 is designed to operate with an ionization chamber and a small number of external components. According to the NXP MC145017 datasheet, the associated circuit is intended for smoke-detector systems designed to comply with UL217 and UL268 specifications. The temporal horn pattern provides an intermittent alarm signal, while the low-power CMOS control section supports battery-powered installations where standby current is a primary design constraint.

Typical applications include residential ionization smoke alarms, commercial smoke-detector modules, and legacy alarm-system replacements that retain the MC145017P pinout. Because the part is listed as obsolete, engineers should treat it primarily as a maintenance component for equipment already built around this device. New smoke-alarm designs should also evaluate current-generation detector ICs against applicable safety requirements rather than assuming an obsolete part can be introduced into a newly certified product.

Circuit design requires careful treatment of the ionization-chamber interface, alarm-driver output, supply decoupling, and test points. Keep sensitive input routing away from the piezoelectric drive path, provide the external components specified by the manufacturer, and verify startup, smoke-entry, alarm-sound, and battery-fallback behavior in the complete detector assembly. The 16-pin PDIP package also requires adequate hole spacing and through-hole assembly clearance on the PCB.

This page consolidates the MC145017P electrical characteristics, package information, application context, and selection considerations into an engineering-focused guide. It also documents the absence of a verified pin-compatible substitute set and highlights the product's obsolete lifecycle status, helping engineers distinguish usable legacy replacements from components that merely perform a similar smoke-detection function.

Mga alternatibo na pwedeng ilagay na MC145017P — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.

Wala ng magagamit na drop-in alternatibo para sa produkto na ito.

Hilingin ang Alternatibo

MC145017P Mga Spesipikasyon

Product Type Low-power CMOS ionization smoke detector IC with temporal-pattern horn driver
Sensor Input Type Ionization
Type ng Output Voltage
Kuru-kuryente ng Pagbibigay 12 µA
Temperature na Operasyon -10°C to 60°C
Packhaging 16-DIP (0.300 inch, 7.62 mm pitch)
Terminal Count 16 terminals
Style ng Pagpapasok Through-hole
Packaging Tube
Process Technology CMOS
Power Classification Low-power device
Alarm Output External piezoelectric transducer driven by internal horn drivers
Alarm Pattern Temporal pattern
Required Sensor External ionization chamber
Designed Smoke-System Compatibility UL217 and UL268 specifications

Gabay sa Pin Configuration ng MC145017P 16-dip (0.300 inch, 7.62 mm pitch)

Pin configuration para sa MC145017P (16-dip (0.300 inch, 7.62 mm pitch) package). Ang pagnunumero ng pin, mga function, at connection diagram ay tinukoy sa datasheet ng manufacturer. Sumangguni dito para sa eksaktong footprint at mga alituntunin sa soldering.

Pinout diagram ng 16-dip (0.300 inch, 7.62 mm pitch) package para sa MC145017P

Wala ng detalyadong pinout data na magagamit para sa MC145017P.

Sumangguni sa datasheet para sa buong pin configuration.

Tipikal na mga Gamit

MC145017P ay nararapat para sa 6 aplikasyons: Residential Ionization Smoke Alarm, Commercial Smoke Detector Module, Legacy Alarm-System Maintenance, Battery-Powered Fire-Safety Sensor, Remote Residential Alarm Sensor, Industrial Enclosure Smoke Sensor.

🏠

Residential Ionization Smoke Alarm

The MC145017P fits a legacy residential ionization smoke alarm because it combines an ionization-chamber interface, low-power CMOS control logic, and a temporal horn driver in one 16-DIP device. Its 12 µA supply current helps preserve battery life during standby, while the internal alarm drivers energize an external piezoelectric transducer when smoke is detected. Installation in a certified product requires the prescribed chamber, resistor network, test arrangement, and sound-output hardware. Because the MC145017P is obsolete, this application is most appropriate for repairing an existing alarm that already uses its exact pinout rather than launching a newly certified consumer product.

🏭

Commercial Smoke Detector Module

The MC145017P can serve as the central detector in a legacy commercial alarm module that uses an ionization chamber and a piezoelectric horn. The 16-pin PDIP construction simplifies through-hole assembly and repair in equipment designed around the original footprint. Its 12 µA supply current supports low standby demand, while the temporal alarm pattern supplies the required intermittent horn signal. The external chamber and acoustic hardware must be arranged to meet the intended UL217 or UL268 system specification. Since the part is obsolete, current commercial designs should verify regulatory and lifecycle requirements before adopting this architecture.

🔧

Legacy Alarm-System Maintenance

The MC145017P is most practical as a maintenance component for installed smoke-alarm equipment that already uses its 16-DIP footprint, chamber interface, and temporal horn-driver configuration. A failed IC can be restored without redesigning the enclosure, PCB, or piezoelectric transducer arrangement when a genuine replacement and exact pinout are confirmed. Its low 12 µA supply current is useful when assessing battery endurance in the restored unit. Before installation, verify device markings, pin orientation, supply behavior, chamber calibration, alarm-sound output, and system test results; component interchange without those checks can compromise the safety function.

🔋

Battery-Powered Fire-Safety Sensor

The MC145017P is suited to battery-powered ionization fire-sensing equipment where standby consumption is important. Its specified 12 µA supply current helps minimize continuous demand from the control electronics, allowing more capacity to remain available for sensing, self-test, and alarm operation. The device accepts the external ionization-chamber signal and controls an external piezoelectric transducer with a temporal pattern. Designers must still account for the chamber current, quiescent paths, battery leakage, and horn-driver load when calculating service life. For new safety products, a supported detector IC with verified certification is generally preferable to this obsolete component.

🏠

Remote Residential Alarm Sensor

The MC145017P can support a remote residential alarm sensor that uses an ionization chamber to detect smoke and a piezoelectric element for local sound. The device's low-power CMOS operation and 12 µA supply-current rating are useful when the sensor must operate for long periods from a limited energy source. Its temporal horn-driver function separates acoustic actuation from the chamber-sensing function, while the DIP package permits straightforward replacement in through-hole legacy hardware. The complete sensor must still be tested for chamber response, false-alarm behavior, test-button operation, sound output, and backup-power capability before deployment.

🏭

Industrial Enclosure Smoke Sensor

The MC145017P may be used in a legacy industrial enclosure smoke sensor that requires ionization sensing and a local piezoelectric alarm. The 16-DIP package and external-component architecture allow the chamber and transducer to be placed according to airflow, insulation, and acoustic requirements while the control IC remains on a through-hole PCB. The 12 µA supply current supports low standby demand, but the -10°C to 60°C operating range must be checked against enclosure temperatures. Validate chamber geometry, contamination tolerance, alarm pattern, and applicable industrial safety requirements. For new installations, confirm the obsolete part's availability and consider a currently supported detector platform.

What is the MC145017P?
The MC145017P is a low-power CMOS ionization smoke detector IC with a temporal-pattern horn driver, packaged in a 16-pin PDIP. According to the NXP MC145017 datasheet, it works with an external ionization chamber and drives an external piezoelectric transducer when smoke is detected. The device combines chamber-signal evaluation, alarm-control logic, and a sound-driver function in one through-hole IC, making it a legacy choice for self-contained residential and commercial smoke-detector assemblies.
What is the supply current of the MC145017P?
The MC145017P has a specified supply current of 12 µA. This low operating current is a defining benefit of the MC145017 in battery-powered smoke alarms because standby demand directly affects battery life and backup-power capacity. The NXP MC145017 datasheet identifies the device as a low-power CMOS smoke detector, so engineers should include the complete chamber, divider network, and peripheral circuitry when calculating worst-case alarm-system current rather than evaluating the IC alone.
What package and temperature range does the MC145017P use?
The MC145017P is supplied in a 16-DIP through-hole package with 0.300-inch, 7.62 mm lead pitch and is specified for -10°C to 60°C operation. NXP lists the part as obsolete, so its package and temperature limits should be checked against the original equipment design during maintenance. The DIP outline requires adequate drilling clearance, while the 70°C total operating-temperature span requires attention in unheated or temperature-variable installations.
How does the MC145017P detect smoke?
The MC145017P detects smoke through an external ionization chamber whose signal is processed by the IC's internal detection logic. When the chamber condition indicates smoke, the device activates its temporal-pattern horn-driver circuitry for an external piezoelectric transducer. The NXP MC145017 datasheet states that the IC requires the chamber and only a small number of additional external components, allowing the sensing and acoustic elements to be arranged according to the detector's mechanical requirements.
Where can I download the MC145017P datasheet PDF?
The official MC145017 datasheet PDF is available from NXP at https://www.nxp.com/docs/en/data-sheet/MC145017.pdf. It describes the low-power CMOS architecture, ionization-chamber interface, external-component requirements, and temporal horn-driver operation. Use the manufacturer's document for final pin assignments, electrical limits, application circuitry, and safety-related implementation details because the MC145017P is obsolete and older third-party copies may not reflect the latest NXP publication.
Where can I find the MC145017P pinout?
The MC145017P pinout is identified in the official NXP MC145017 datasheet at https://www.nxp.com/docs/en/data-sheet/MC145017.pdf. Use the package pin-description table and typical-application schematic when assigning PCB nets, especially for the ionization-chamber input, supply, test points, and piezoelectric alarm outputs. The component has 16 pins in a PDIP outline, and pin functions should not be inferred from similarly named Motorola interface ICs because they serve different functions.
Is the MC145017P still active?
No. The MC145017P is listed as obsolete by NXP, so it is primarily appropriate for maintenance of equipment already designed around this device rather than new platform creation. According to the NXP product information and distributor records, the part remains identifiable in a 16-DIP package with a -10°C to 60°C operating range. For a new smoke alarm, evaluate current detector ICs and complete the applicable certification process before freezing the design.
What can replace the MC145017P?
No verified pin-to-pin drop-in replacement for the MC145017P was identified in the available cross-reference results. A practical replacement must match the 16-pin PDIP footprint, ionization-chamber interface, supply limits, 12 µA-class operating requirement, and temporal piezoelectric horn-driving behavior. Similar smoke-detector or timer ICs are not automatically interchangeable, so use the NXP datasheet as the acceptance baseline and request a manufacturer-confirmed substitute before changing an existing alarm PCB.
Is the MC145017P the same as the MC14538BDTR2G?
No. The MC14538BDTR2G and MC145017P are not interchangeable drop-in parts because the MC14538BDTR2G uses a surface-mount package while the MC145017P uses a 16-DIP package, and their functional roles differ. The MC145017P is a dedicated ionization smoke detector with a horn driver, whereas the MC14538BDTR2G belongs to a different interface-timing family. PCB and alarm behavior both change if they are substituted.
MC145017P versus another ionization smoke detector IC: which is better?
The MC145017P is preferable only when maintaining equipment that requires its exact 16-DIP pinout, ionization-chamber interface, 12 µA supply current, and temporal horn-driver behavior. A modern detector IC may offer better lifecycle support or certification positioning, but it is not a drop-in choice unless its package, electrical limits, chamber interface, test architecture, and alarm output are explicitly verified. For new designs, compare current components against the required UL217 or UL268 system specification.
When should I choose the MC145017P over a newer smoke detector IC?
Choose the MC145017P when repairing an existing alarm that uses its exact 16-DIP pinout and circuitry, and only when a genuine, manufacturer-authorized supply is available for that obsolete part. Its 12 µA supply current and temporal-pattern horn driver may simplify restoration of the original design. For a newly designed detector, favor a currently supported component because compatibility certification, software timing, chamber calibration, and regulatory validation generally matter more than reproducing a legacy board.
Is the MC145017P suitable for a residential smoke alarm?
The MC145017P is technically designed for ionization smoke-detector systems and can drive an external piezoelectric transducer through a temporal alarm pattern. Its suitability for a specific residential product also depends on the complete chamber circuit, battery design, alarm sound level, test functions, failure monitoring, and certification of the assembled detector. Because the IC is obsolete, engineers should preserve it for legacy service work and use a currently supported, certified detector platform for new residential products.
How much heat does the MC145017P dissipate?
The MC145017P's power dissipation cannot be calculated reliably from the identified 12 µA supply-current figure alone because the operating supply voltage and internal switching activity are not stated in the product snippets. Use the NXP MC145017 datasheet for supply-voltage limits, quiescent-current conditions, and horn-drive output characteristics. At the IC level, a first-order estimate is P = VIN × ICURRENT, but the complete alarm driver and chamber network must also be included for total standby and alarm energy.
Can a photoelectric smoke detector replace the MC145017P?
A photoelectric smoke detector is not a direct replacement for the MC145017P because the sensing principle and external interface differ. The MC145017P requires an ionization chamber and specifically controls a piezoelectric alarm through its temporal horn-driver function. A photoelectric implementation may use a different IC, sensor arrangement, PCB, and system-test method. Use it only as a platform-level redesign, not as a drop-in substitution for an existing MC145017P board.
What are the key specifications of MC145017P that engineers should know?
The key MC145017P specifications are 12 µA supply current, a -10°C to 60°C operating range, a 16-pin PDIP package, ionization-sensor input, voltage output, CMOS construction, and temporal-pattern horn driving for an external piezoelectric transducer. According to the NXP MC145017 datasheet, the circuit is intended for smoke-detector systems designed around UL217 and UL268 specifications. The obsolete lifecycle status is also critical because replacement sourcing and new-product qualification may be difficult.
Where can I buy MC145017P and what is its price?
Use the Request a Quote form on this page to request current MC145017P availability, pricing, minimum order quantity, and lead time. The component is obsolete, so its commercial status may vary by package suffix and inventory lot. Do not use a historical distributor amount as a present quotation; request the exact 16-PDIP MPN MC145017P and confirm date code, condition, and traceability when placing the order.
Is MC145017P in stock and what is the lead time?
Current stock and lead time for the obsolete MC145017P should be requested through the Request a Quote form on this page. The product listing identifies the device as obsolete, so no production lifecycle guarantee should be assumed even if a historical listing states immediate shipment. A sourcing request should specify the required quantity, tube packaging, acceptable date codes, and whether traceability documentation is mandatory for the smoke-alarm assembly.

Impormasyon ng Talumpati sa Engineering for MC145017P — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.

Paunawang Hanapin

Select the MC145017P only when repairing or reproducing an existing design that uses its exact 16-DIP footprint, ionization-chamber interface, supply requirements, test functions, and temporal piezoelectric horn-driver behavior. Its 12 µA supply current and integrated smoke-detection control are valuable in battery-powered legacy alarms, while the obsolete lifecycle status makes procurement and long-term availability the dominant constraints. Do not select the MC14536BCP or MC14538BDTR2G as replacements because they provide different functions and packages. For a newly designed residential or commercial alarm, compare currently supported detector ICs, evaluate chamber technology, complete acoustic and self-test validation, and confirm compliance with the required UL217 or UL268 system specification. A legacy-only repair should also verify date code, condition, and traceability through the Request a Quote form.

Ikabit sa Mga Alternatibo

Parametro Ito ang Producto
Manufacturer NXP Semiconductors
Package 16-DIP (0.300 inch, 7.62 mm pitch)
Mounting Style Through-hole
Product Function Ionization smoke detector IC with temporal-pattern horn driver
Sensor Input Ionization
Output Type Voltage
Supply Current 12 µA
Operating Temperature -10°C to 60°C
Process Technology CMOS
Lifecycle Status Obsolete

Pangunahing mga Pagkakaiba

  • Integrated ionization sensing and temporal alarm control (kumpara saMC14538BDTR2G)
  • Low standby supply current (kumpara saGeneric legacy smoke-detector interface)
  • Established legacy package and system orientation (kumpara saMC14536BCP)

Talaan ng Disenyo

Route the ionization-chamber signal with short traces, a guarded area, and minimal loop area to reduce susceptibility to EMI and leakage. Keep these sensitive nodes away from the piezoelectric horn-driver traces and switching or power-conversion paths. Use a stable reference ground for the chamber network and follow the grounding arrangement in the manufacturer application schematic. After layout, verify both normal chamber operation and immunity to nearby alarm-drive and supply transients.

Estimate battery endurance from the complete alarm circuit rather than the MC145017P supply current alone. The IC contributes 12 µA, while the chamber, bias network, leakage paths, test circuitry, and piezoelectric transducer can change the system load. Start with Pstandby = VIN × Istandby and divide usable battery energy by measured standby and alarm power. Include battery self-discharge, temperature capacity loss, and end-of-life voltage when establishing the service interval.

Do not substitute the MC145017P with a generic timer, oscillator, or smoke-detector IC merely because its alarm function appears similar. A valid repair part must preserve the 16-DIP pinout, ionization-chamber interface, supply limits, 12 µA-class operating behavior, test circuitry, and temporal piezoelectric drive. Verify device orientation and markings before energizing the board, then perform chamber, self-test, alarm-sound, and power-failure checks on the assembled detector.

The IC package is not the primary thermal concern in a low-power smoke detector, but the piezoelectric transducer and power source may impose separate limits. Check the manufacturer's horn-driver output characteristics before adding series resistance or changing the transducer. If the operating environment exceeds the MC145017P range of -10°C to 60°C, relocate or protect the assembly rather than assuming the through-hole package provides environmental tolerance.

Impormasyon ng Pagsunod sa Kautusan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Walang Lead
Unknown
Walang Halogen
Unknown
Mga Conflict Mineral
Unknown

The NXP MC145017 datasheet states that the circuit is designed for smoke-detector systems that comply with UL217 and UL268 specifications. This system-design reference does not establish the MC145017P's own RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification status.

Data napatotohanan sa: 2026-11-05 — impormasyon na pinatunayan at pinapatakbo ng pangkat ng engineering ng XAIPART's component engineering team

Kaugnay na Hanapin

MC145017P datasheet MC145017P pinout MC145017P datasheet pdf MC145017P equivalent MC145017P replacement MC145017P cross reference MC145017P schematic MC145017P application circuit MC145017P 16-DIP pinout MC145017P price MC145017P stock NXP MC145017P

Mga kaugnay na Mga Komponente at mga Tuntunin

NXP Semiconductors MC145017P MC145017 MC14538BDTR2G MC14536BCP ionization smoke detector smoke detector IC sensor and detector interface ionization chamber temporal-pattern horn driver piezoelectric transducer CMOS low-power semiconductor 16-DIP through-hole package voltage output supply current battery-operated alarm UL217 UL268 residential smoke alarm commercial smoke detector legacy alarm-system maintenance obsolete component fire-safety sensor
Mabilis na Tanggap na RFQ
Ihanda ang buong detalye — ang aming pangkalakal na koponan ay tutugon sa loob ng 24 oras
Numero ng Parte Mga Tagagawa Pakete QTY Target na Halaga Pinalawak
✓
Quote na inilabas!

Ating tumugon sa iyong email sa loob ng 24 oras

1
RFQ Naisumite
2
Received na ang Kwaliksik
3
Nai-order
4
Pagbabayad
5
Inihanda
6
Naihanda
Tingnan ang Detalye ng RFQ