Silicon Laboratories

SI3012-KS - V.90 Global MC'97 Silicon DAA | Silicon Laboratories

MPN: SI3012-KS ✗ Tapus ng Buhay
5 V Vdss 16-pin SOIC Package
MOQ: 1 |

SI3012-KS Ulas

Silicon Laboratories SI3012-KS is a Global MC'97 silicon direct access arrangement for modem and telephone-line-interface applications, combining an AC'97 2.1-compliant primary or secondary codec with a global phone-line interface. The device provides 84 dB dynamic range across its transmit and receive paths, operates from a 5 V power supply, and is offered in a 16-pin SOIC package.

A direct access arrangement, or DAA, is the telephone-interface portion of a modem or communications system. It connects the host codec and modem data path to an analog telephone line while providing the signaling, isolation, and transmit/receive functions needed for global line-interface operation. In the component hierarchy, the SI3012-KS is a communications interface IC rather than a general-purpose codec or memory device.

Verified feature data identifies AC'97 2.1 compliance, support for primary or secondary codec operation, and compatibility with FCC, CTR21, JATE, and other public telephone network requirements. Its 84 dB dynamic range provides the principal quantified signal-path performance figure, while the 5 V supply simplifies integration with conventional communications equipment.

The SI3012-KS is specifically associated with V.90 modem designs and is listed as a Modem V.90 device in 16-SOIC packaging. The product is marked not recommended for new designs, with Si3018 identified by the distributor listing as the recommended successor for new-product planning. This lifecycle distinction is important for maintenance and repair work involving existing V.90 equipment.

Typical uses include V.90 data-modem hardware, analog telephone-line interfaces, primary and secondary AC'97 codec connections, and legacy communications equipment requiring global telephone-network interface support. Its 5 V operating supply and 84 dB transmit/receive dynamic range fit established analog modem architectures, while the stated regulatory and PTT compatibility support deployment across multiple international line standards.

Designers should preserve the manufacturer's reference circuit and verify the external isolation, line-interface, and codec connections against the SI3012-KS datasheet. Because the SI3012-KS is not recommended for new designs, new products should evaluate the Si3018 instead of assuming functional interchangeability. The available search data does not provide a verified pinout, detailed timing specification, or manufacturer pricing, so those values should be confirmed before schematic capture or procurement.

This page distinguishes the SI3012-KS communications DAA from the similarly named Sanken SI-3012KS low-dropout regulator, consolidates verified lifecycle and feature information, and identifies the documented successor path for engineers evaluating legacy V.90 modem designs.

Mga alternatibo na pwedeng ilagay na SI3012-KS — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.

Wala ng magagamit na drop-in alternatibo para sa produkto na ito.

Hilingin ang Alternatibo

SI3012-KS Mga Spesipikasyon

Product Type Global MC'97 silicon direct access arrangement
Application Classification V.90 modem
AC'97 Interface Compliance AC'97 2.1 compliant
Codec Role Primary or secondary codec
Line Interface Global phone-line interface
Dynamic Range 84 dB across TX/RX paths
Power Supply Voltage 5 V
Isolation Voltage Greater than 3000 V
Regulatory Compatibility FCC, CTR21, JATE, and other PTTs
Packhaging 16-pin SOIC
Uri ng Pagpapasok Surface Mount
Lifecycle Recommendation Not recommended for new designs; Si3018 identified as successor
Manufacturer Silicon Laboratories

Gabay sa Pin Configuration ng SI3012-KS 16-pin soic

Pin configuration para sa SI3012-KS (16-pin soic package). Ang pagnunumero ng pin, mga function, at connection diagram ay tinukoy sa datasheet ng manufacturer. Sumangguni dito para sa eksaktong footprint at mga alituntunin sa soldering.

Pinout diagram ng 16-pin soic package para sa SI3012-KS

Wala ng detalyadong pinout data na magagamit para sa SI3012-KS.

Sumangguni sa datasheet para sa buong pin configuration.

Tipikal na mga Gamit

SI3012-KS ay nararapat para sa 6 aplikasyons: V.90 Modem Line Interface, Global Analog Telephone-Line Interface, Primary AC'97 Codec Connection, Secondary AC'97 Codec Connection, Legacy Communication Equipment Maintenance, Telephone Network Isolation Stage.

🌐

V.90 Modem Line Interface

The SI3012-KS fits established V.90 modem hardware because it combines an AC'97 2.1-compliant primary or secondary codec connection with a global phone-line interface. Its 5 V supply matches conventional modem electronics, while the 84 dB dynamic range across the TX and RX paths provides the documented signal-chain performance. In a new design, the non-recommended-for-new-designs status of the SI3012-KS should override otherwise attractive legacy compatibility, so engineers should evaluate the Si3018 as the named successor. For repair and product-maintenance work, preserving the existing 16-SOIC layout may justify continued use of the SI3012-KS after confirming distributor availability and regulatory requirements.

📞

Global Analog Telephone-Line Interface

The SI3012-KS is applicable to global analog telephone-line equipment because its verified feature set identifies compliance with FCC, CTR21, JATE, and other public telephone network requirements. The device combines the codec-side interface with the line-side DAA functions needed by a modem, rather than requiring a codec alone. Its greater than 3000 V isolation rating is the key quantified electrical feature for reviewing telephone-line separation, while the 5 V supply simplifies integration with the surrounding modem electronics. Each country or network still requires confirmation of applicable approvals and line-interface details before production release.

🔧

Primary AC'97 Codec Connection

The SI3012-KS can be used in modem architectures requiring a primary AC'97 codec connection, as explicitly stated in the verified feature listing. This role places the DAA on the host-side digital codec path while retaining its global telephone-line interface. The 2.1-compliant interface, 5 V operating supply, and 84 dB transmit/receive dynamic range provide the main design checkpoints. Because the available data does not expose complete timing tables or pin assignments, an engineer must reproduce the manufacturer reference circuit and verify signal and isolation requirements in the original datasheet before layout release.

🎧

Secondary AC'97 Codec Connection

The SI3012-KS supports secondary as well as primary codec operation, allowing it to fit systems in which the modem data path is attached differently from a primary host codec. This flexibility makes the part useful when maintaining established AC'97-based modem designs. Its 84 dB TX/RX dynamic range and 5 V power supply are the primary quantified fit criteria, while global line-interface and greater than 3000 V isolation support remain essential. For new equipment, engineers should evaluate the Si3018 because the verified distributor data marks the SI3012-KS as not recommended for new designs.

🏭

Legacy Communication Equipment Maintenance

The SI3012-KS is most defensible in maintenance, repair, and continuation-of-production programs for existing V.90 modem equipment. Its 16-SOIC package and established V.90 association make it potentially useful where the surrounding board and firmware cannot be redesigned. The documented 5 V supply, 84 dB TX/RX dynamic range, AC'97 2.1 interface, and global line-interface capabilities provide a basis for identifying the correct legacy part. Procurement should account for its NRND status, and the SI3012-KS must be distinguished from the unrelated Sanken SI-3012KS regulator when searching distributor databases.

🔒

Telephone Network Isolation Stage

The SI3012-KS can participate in a telephone-network isolation stage because the verified documentation specifies greater than 3000 V isolation for the Global MC'97 silicon DAA. Isolation is central to separating the line-connected communications circuitry from the host system, and the 5 V supply permits integration with conventional modem electronics. The value must still be evaluated using the manufacturer's complete application circuit, creepage, clearance, and component requirements rather than treated as a standalone guarantee. The FCC, CTR21, JATE, and other PTT compatibility listed for the device supports international legacy deployments subject to local approval.

What is the Silicon Laboratories SI3012-KS?
The Silicon Laboratories SI3012-KS is a Global MC'97 silicon direct access arrangement for V.90 modem and telephone-line-interface equipment. According to the manufacturer datasheet listing, it includes an AC'97 2.1-compliant primary or secondary codec, a global phone-line interface, 84 dB dynamic range across the transmit and receive paths, a 5 V power supply, and greater than 3000 V isolation.
What are the key specifications of SI3012-KS that engineers should know?
The SI3012-KS is a 5 V, 16-SOIC Global MC'97 silicon DAA with AC'97 2.1 interface compliance. The verified data identifies support for primary or secondary codec operation, 84 dB TX/RX dynamic range, greater than 3000 V isolation, and compatibility with FCC, CTR21, JATE, and other public telephone network requirements. It is also associated with V.90 modem applications and is not recommended for new designs.
Where can I download the SI3012-KS datasheet PDF?
The SI3012-KS datasheet can be accessed through the listed Silicon Laboratories document viewer at https://www.datasheetq.com/en/pdf-view/SI3012-KS-Silabs. The associated search result describes a 64-page document and identifies the device as a Global MC'97 silicon DAA. The manufacturer document should be consulted for the authoritative pin assignments, application circuit, timing values, and electrical limits.
Where can I find the SI3012-KS pinout?
The SI3012-KS pinout is located in the manufacturer's Global MC'97 Silicon DAA datasheet, available through the listed Silicon Laboratories document viewer. The verified catalog data identifies a 16-pin SOIC package but does not expose individual pin names or numbers, so a complete pin list cannot be reproduced reliably. Do not substitute a similarly named Sanken SI-3012KS pinout because that is a different linear-regulator product.
Is SI3012-KS in stock or recommended for new designs?
The SI3012-KS is not recommended for new designs, and the Mouser listing directs buyers to the Si3018 datasheet for inventory and pricing information. The supplied web results do not provide a stable, part-specific stock count. Accordingly, availability should be confirmed directly with an authorized distributor, while new designs should evaluate Si3018 as the documented successor.
What is the price of SI3012-KS?
A verified numeric price for the SI3012-KS is not present in the supplied distributor data, so no market price can be stated reliably. The available DigiKey and Mouser pages are appropriate sources for quote and inventory confirmation as of 2026-10-28. The quantity tiers on this page use zero only as a machine-readable placeholder for unavailable quote data and must not be treated as a sell price.
Where can I buy SI3012-KS online?
SI3012-KS is listed by DigiKey and Mouser, and Octopart provides a cross-distributor view of availability, pricing, and technical specifications. As of 2026-10-28, the verified data does not disclose an exact unit price or guaranteed stock quantity. Buyers should use the listed distributor pages, confirm the 16-SOIC package, and request current lifecycle and delivery information before placing an order.
What is the lead time for SI3012-KS?
The current lead time for SI3012-KS is not stated in the supplied web data and must be confirmed with the distributor at the time of quotation. Because the product is not recommended for new designs and the Si3018 is named as its successor, long-lead maintenance demand may affect availability. The Octopart listing is a useful starting point for comparing multiple distributors, but it does not establish a guaranteed lead time.
What is the difference between SI3012-KS and the Sanken SI-3012KS?
The Silicon Laboratories SI3012-KS is a Global MC'97 silicon DAA for V.90 modems, while the Sanken SI-3012KS is a low-dropout linear regulator IC. The verified Sanken listing describes a 5 V power-supply-related regulator with low dropout, low quiescent current, and overcurrent and thermal protection. These are entirely different functional devices despite similar character sequences and must never be treated as interchangeable.
SI3012-KS vs Si3018 - which is better for a new modem design?
The Si3018 is the better-supported choice for a new modem design because the verified Mouser listing identifies it as the recommended successor to the non-recommended-for-new-designs SI3012-KS. The SI3012-KS remains relevant for maintaining existing V.90 equipment, but designers should verify pin compatibility, AC'97 behavior, isolation requirements, and electrical characteristics before attempting a substitution.
When should I choose SI3012-KS over a newer DAA?
Choose SI3012-KS primarily when maintaining or repairing an existing design that already uses this exact 16-SOIC DAA and cannot change its board layout or surrounding circuitry. For new V.90 modem products, choose the Si3018 because the SI3012-KS is explicitly marked not recommended for new designs. A legacy replacement should still be checked against the original schematic, firmware assumptions, and isolation requirements.
Is SI3012-KS suitable for global telephone-line equipment?
Yes, SI3012-KS is described as a Global MC'97 silicon DAA with a global phone-line interface and compatibility with FCC, CTR21, JATE, and other public telephone network requirements. Its 5 V supply, 84 dB TX/RX dynamic range, and greater than 3000 V isolation align with established global modem-line equipment. Local approvals and network-interface rules must still be confirmed for each deployment region.
What can replace SI3012-KS?
The Si3018 is the documented successor path identified in the verified distributor listing, but the supplied data does not establish that it is a pin-for-pin drop-in replacement for SI3012-KS. No other verified drop-in substitute was found in the cross-reference results. Therefore, Si3018 should be treated as a design migration candidate until its package, pinout, interface timing, isolation, and regulatory characteristics are compared directly.
Can an AC'97 modem codec replace SI3012-KS?
No, a general-purpose AC'97 modem codec is not automatically a replacement for the SI3012-KS because the SI3012-KS combines codec interfacing with a global phone-line direct access arrangement. A valid substitute must preserve the required line interface, isolation, codec role, supply requirements, and package-level connections. The supplied cross-reference results do not identify such a drop-in part.
Does SI3012-KS use a 5 V supply and provide 84 dB dynamic range?
Yes, the verified SI3012-KS feature listing specifies a 5 V power supply and 84 dB dynamic range for the transmit and receive paths. The same source identifies AC'97 2.1 compliance, primary or secondary codec operation, and greater than 3000 V isolation. These figures describe the communications DAA and should not be confused with specifications for the similarly named Sanken low-dropout regulator.

Impormasyon ng Talumpati sa Engineering for SI3012-KS — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.

Paunawang Hanapin

Choose the SI3012-KS only for an existing V.90 modem or Global MC'97 DAA design where preserving the 16-SOIC implementation is valuable and the distributor can confirm availability. Its 5 V supply, 84 dB TX/RX dynamic range, AC'97 2.1 support, and greater than 3000 V isolation are appropriate for legacy maintenance. Do not choose it for a new product because the verified distributor listing marks it not recommended for new designs and identifies the Si3018 as the successor. Treat the Si3018 as a migration candidate rather than an automatic drop-in replacement until package, pinout, timing, isolation, codec role, and regulatory differences are verified. Also reject the similarly named Sanken SI-3012KS because it is a low-dropout regulator, not a modem DAA.

Pangunahing mga Pagkakaiba

  • Complete legacy telephone-interface function (kumpara saGeneral-purpose AC'97 codec)
  • International line-interface coverage (kumpara saRegion-specific telephone interface)
  • Established 5 V V.90 integration (kumpara saSi3018)

Talaan ng Disenyo

Do not confuse Silicon Laboratories SI3012-KS with the Sanken SI-3012KS. The former is a 16-SOIC Global MC'97 silicon DAA for V.90 modem equipment, while the latter is an 8-pin low-dropout linear regulator. Their similar character sequences create a serious procurement and schematic-substitution risk, so use the full manufacturer name, package, and function together when searching or requesting parts.

Treat the SI3012-KS as a line-interface device rather than a generic codec. Preserve the manufacturer reference schematic for telephone-line isolation, codec-side routing, and supply decoupling, and verify the applicable creepage, clearance, and isolation requirements for the target country. The available verified excerpt confirms greater than 3000 V isolation but does not provide a complete PCB layout or safety table, so those details must be taken directly from the manufacturer documentation.

The SI3012-KS operates from 5 V. Confirm the complete modem-board power tree and the voltage tolerances of every external line-interface component before substituting it into an existing design. The search excerpt provides no current consumption, tolerance, or sequencing limits, so a power budget cannot be calculated reliably from the available data. Use the manufacturer electrical-characteristics table and original board schematic for those checks.

Use the documented 84 dB dynamic range as the principal TX/RX signal-chain performance target when assessing an existing design. AC'97 2.1 compliance identifies the digital codec interface version but does not provide bus timing, clocking, or impedance guidance in the supplied excerpts. Preserve established routing, grounding, isolation, and codec clock arrangements when repairing the design, and consult the full datasheet before altering edge rates or trace topology.

Impormasyon ng Pagsunod sa Kautusan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Walang Lead
Unknown
Walang Halogen
Unknown
Mga Conflict Mineral
Unknown

The verified feature data identifies FCC, CTR21, JATE, and other PTT compatibility, but no explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals declarations were supplied. AEC-Q100 is not applicable because this is a communications DAA rather than an automotive-qualified device.

Data napatotohanan sa: 2026-10-28 — impormasyon na pinatunayan at pinapatakbo ng pangkat ng engineering ng XAIPART's component engineering team

Kaugnay na Hanapin

SI3012-KS SI3012-KS datasheet PDF Silicon Laboratories SI3012-KS Global MC'97 silicon DAA 16-SOIC V.90 modem DAA SI3012-KS AC'97 2.1 codec interface SI3012-KS global phone line interface SI3012-KS vs Si3018 SI3012-KS drop-in replacement SI3012-KS price and availability where to find SI3012-KS pinout what can replace SI3012-KS

Mga kaugnay na Mga Komponente at mga Tuntunin

Silicon Laboratories SI3012-KS Si3018 Global MC'97 silicon DAA direct access arrangement V.90 modem AC'97 2.1 primary codec secondary codec global phone-line interface 84 dB dynamic range 5 V power supply greater than 3000 V isolation 16-pin SOIC surface mount FCC CTR21 JATE public telephone network Sanken SI-3012KS low-dropout linear regulator legacy communications equipment telephone-line isolation
Mabilis na Tanggap na RFQ
Ihanda ang buong detalye — ang aming pangkalakal na koponan ay tutugon sa loob ng 24 oras
Numero ng Parte Mga Tagagawa Pakete QTY Target na Halaga Pinalawak
✓
Quote na inilabas!

Ating tumugon sa iyong email sa loob ng 24 oras

1
RFQ Naisumite
2
Received na ang Kwaliksik
3
Nai-order
4
Pagbabayad
5
Inihanda
6
Naihanda
Tingnan ang Detalye ng RFQ