TJA1050T/H/V - 1 Mbaud 5V CAN Transceiver | NXP
MPN: TJA1050T/H/V ✗ Tapus ng BuhayTJA1050T/H/V Ulas
A CAN transceiver is a physical-layer interface within the Controller Area Network communication hierarchy. It translates logic-level TXD and RXD signals into the dominant and recessive voltage states carried by CANH and CANL. The differential bus arrangement supports noise rejection and allows multiple nodes to communicate over a shared two-wire network in automotive, industrial, and control systems.
Key features of the TJA1050T/H/V include a 1 Mbaud maximum signaling rate, a nominal 5 V supply, operation from a 4.75 V to 5.25 V supply range, and an 8-pin SOIC package. Silent mode disables the transmitter while retaining receiver operation, while the TXD dominant timeout prevents the bus from remaining permanently dominant if TXD is held low by a controller or software failure.
The device supports differential transmit and receive communication and is intended to connect a CAN controller to a physical CAN bus. Its bus pins are protected against electrical stress, and an unpowered node does not disturb the bus lines. The TJA1050 also provides improved electromagnetic-emission behavior compared with earlier CAN transceiver generations, an important consideration in compact embedded equipment.
Typical uses include automotive body and powertrain control modules, industrial automation equipment, machine controllers, robotics, elevator systems, and service-bus networks. The 1 Mbaud capability supports both conventional automotive CAN traffic and faster industrial CAN systems, although the complete bus must be designed for the intended bit rate, termination, topology, and electromagnetic environment.
When laying out the PCB, place the transceiver close to the CANH and CANL connector or transceiver connector, provide the specified bus termination only at the two physical ends of the bus, and keep the CAN pair routed together with continuous reference to the ground plane. Decoupling capacitors should be placed close to VCC and GND, while protection components should be selected to preserve differential bus behavior.
This product page combines the manufacturer specification, ordering information, lifecycle status, alternative ordering codes, and practical replacement guidance. It also distinguishes genuine same-package drop-in choices from newer transceivers that require different voltage, pin, standby, or common-mode implementation decisions.
Mga alternatibo na pwedeng ilagay na TJA1050T/H/V — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.
TJA1050T/CM,118
✅ Drop-In📋 Alternatibo na Reference (hindi sa katalogo)
TJA1050T/VM,118
✅ Drop-In📋 Alternatibo na Reference (hindi sa katalogo)
TJA1050T/118,112
✅ Drop-In📋 Alternatibo na Reference (hindi sa katalogo)
TJA1050T/V,112
✅ Drop-In📋 Alternatibo na Reference (hindi sa katalogo)
TJA1050T/H/V,118
✅ Drop-In📋 Alternatibo na Reference (hindi sa katalogo)
TJA1050T/H/V Mga Spesipikasyon
| Product Type | High-speed CAN transceiver |
| CAN Bus Data Rate | Up to 1 Mbaud |
| Nominal Supply Voltage | 5 V |
| Supply Voltage na Operasyon | 4.75 V to 5.25 V |
| Supply Pin Count | 1 VCC pin |
| Ground Pin Count | 1 GND pin |
| Differential Transmit Capability | Yes |
| Differential Receive Capability | Yes |
| Transmitter Silent Mode | Yes |
| TXD Dominant Timeout | Yes |
| Unpowered Node Bus Disturbance | No disturbance of the bus lines |
| Bus Pin Protection | Protected |
| Packhaging | 8-pin SOIC |
| Uri ng Pagpapasok | Surface mount |
| Electromagnetic Emission Performance | Improved relative to earlier CAN transceiver generations |
| Tindminan RoHS | unknown |
| REACH Status | unknown |
Pin Configuration ng TJA1050T/H/V
| Pin 1 | TXD — Transmit data input from the CAN controller |
| Pin 2 | GND — Ground connection |
| Pin 3 | VREF — Voltage reference output used for common-mode control |
| Pin 4 | RXD — Receive data output to the CAN controller |
| Pin 5 | VCC — 5 V supply connection |
| Pin 6 | CANL — CAN low bus terminal |
| Pin 7 | CANH — CAN high bus terminal |
| Pin 8 | S — Silent-mode input |
Tipikal na mga Gamit
TJA1050T/H/V ay nararapat para sa 6 aplikasyons: Automotive Body Control Module, Industrial Automation Controller, Robotics Motor Network, Machine Tool Communication, Elevator and Building Control, Legacy CAN Test and Service Tool.
Automotive Body Control Module
The TJA1050T/H/V fits an automotive body control module that connects a CAN controller to door, lighting, climate, or seat-control nodes. Its 1 Mbaud capability accommodates conventional high-speed CAN networks, while differential transmission and reception support reliable signaling over a shared two-wire bus. The TXD dominant timeout can prevent a controller failure from holding the network dominant indefinitely. Because the device is legacy and listed as end of life, an existing module can retain its 8-pin SOIC layout, but a new platform should also evaluate current-generation transceivers with suitable low-power and fault-protection features.
Inirekomenda
Industrial Automation Controller
The TJA1050T/H/V can connect an industrial controller to remote actuators, sensors, drives, or operator panels over a CAN bus. A nominal 5 V supply and operation up to 1 Mbaud suit embedded 5 V control platforms, while the differential physical layer helps reject common-mode noise found around motors and switching equipment. The 8-pin SOIC footprint simplifies use in compact control boards. Design the bus according to the manufacturer's application guidance, including termination at the two ends, controlled stub lengths, and placement of the transceiver near the bus connector.
Inirekomenda
Robotics Motor Network
The TJA1050T/H/V is suitable for CAN-based robot coordination when motors and actuators communicate through a common bus. The 1 Mbaud rate allows higher bus activity than lower-speed serial links, and the differential CAN interface supports communication between distributed modules. Silent mode provides a way to disable transmission during selected test or shutdown states without removing the physical interface. The bus layout should keep CANH and CANL paired, use a continuous ground reference, and separate high-current motor paths from the transceiver and controller traces.
Inirekomenda
Machine Tool Communication
A machine-tool controller can use the TJA1050T/H/V to communicate with distributed I/O, servo drives, safety-related monitoring modules, and service interfaces. The 5 V operating range is compatible with conventional embedded CAN controller platforms, and the 8-pin SOIC package supports compact, surface-mounted assemblies. The differential bus reduces susceptibility to common-mode industrial noise, but correct termination and topology remain essential at 1 Mbaud. For new machine platforms with long lifecycle requirements, evaluate the obsolete status alongside newer CAN transceivers that may offer enhanced bus-fault handling.
Inirekomenda
Elevator and Building Control
The TJA1050T/H/V can serve as the physical-layer interface in elevator controllers, door systems, and building-control nodes that exchange commands over CAN. Its 1 Mbaud capability supports compact control networks with several communicating units, while differential signaling helps maintain reliable operation around relays, lighting electronics, and motor equipment. The transmitter silent mode is useful when a node must monitor without asserting the bus. Keep the CAN pair away from high-energy switching traces and verify that cable length and node spacing remain appropriate for the selected signaling rate.
Inirekomenda
Legacy CAN Test and Service Tool
The TJA1050T/H/V can be retained in a diagnostic fixture or service tool designed for an existing 5 V CAN controller and SO-8 layout. Its differential receiver supports bus monitoring, while silent mode permits a tester to observe traffic without driving the network. The TXD dominant timeout protects the bus if the test host fails during transmission. Since this is an end-of-life device, service equipment should use controlled procurement and verify the exact ordering attributes before assembly. New test tools should assess contemporary CAN transceivers with programmable standby or diagnostic functions.
Inirekomenda
Buod ng mga Inirekomendang Produkto
Impormasyon ng Talumpati sa Engineering for TJA1050T/H/V — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.
Paunawang Hanapin
Ikabit sa Mga Alternatibo
| Parametro | Ito ang Producto | TJA1050T/CM,118 | TJA1050T/VM,118 | TJA1050T/118,112 | TJA1050T/V,112 | TJA1050T/H/V,118 |
|---|---|---|---|---|---|---|
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC |
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors |
| Product Type | High-speed CAN transceiver | High-speed CAN transceiver | High-speed CAN transceiver | High-speed CAN transceiver | High-speed CAN transceiver | High-speed CAN transceiver |
| Maximum Data Rate | 1 Mbaud | 1 Mbaud | 1 Mbaud | 1 Mbaud | 1 Mbaud | 1 Mbaud |
| Nominal Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V | 5 V |
| Operating Supply Range | 4.75 V to 5.25 V | 4.75 V to 5.25 V | 4.75 V to 5.25 V | 4.75 V to 5.25 V | 4.75 V to 5.25 V | 4.75 V to 5.25 V |
| Transmitter Silent Mode | Yes | Yes | Yes | Yes | Yes | Yes |
| TXD Dominant Timeout | Yes | Yes | Yes | Yes | Yes | Yes |
| Lifecycle Status | End of life | End of life | End of life | End of life | End of life | End of life |
Pangunahing mga Pagkakaiba
- Maintains a 1 Mbaud CAN interface in the original 8-pin SOIC footprint (kumpara saTJA1051T/3)
- Preserves the established TJA1050 family behavior for controlled legacy maintenance (kumpara saTJA1057T,118)
- Supports deterministic protection against a permanently dominant TXD state (kumpara saSN65HVD1050A-Q1)
Talaan ng Disenyo
Route CANH and CANL as a close, continuous differential pair over a solid ground reference. Keep the transceiver near the bus connector or transceiver connector to minimize the unprotected stub, and avoid introducing test pads or routing discontinuities in the pair. At 1 Mbaud, trace geometry, external components, and connector transitions can materially affect signal integrity, so review the complete bus path rather than treating the PCB route as an isolated item.
Decouple the 5 V VCC pin close to the device with the capacitance specified by the NXP application guidance, and provide a low-impedance return to the ground plane. The transceiver's operating range is 4.75 V to 5.25 V, so verify supply tolerance, startup sequencing, and controller I/O levels across the complete board. Avoid placing switching-regulator high-current paths between the decoupling capacitor and VCC pin.
Do not use a 120 ohm termination resistor at every node; install the standard bus termination only at the two physical ends of the CAN bus. Also avoid leaving the VREF and silent-mode pins in electrically undefined states. Follow the manufacturer pin-description table for their configured levels. Incorrect termination or an undefined control input can cause reflections, unintended dominant states, or inconsistent behavior when the transmitter is disabled.
For industrial or automotive equipment, isolate the CAN bus from sources of electromagnetic interference and confirm the transceiver's common-mode behavior under the actual installation conditions. The differential interface improves noise rejection, but it does not remove the need for controlled topology, suitable cable routing, and common-mode margin. Review protection-component capacitance because excessive filtering at the connector can degrade edge quality at 1 Mbaud.
Impormasyon ng Pagsunod sa Kautusan
The manufacturer product information identifies the TJA1050 as end of life, but the available product pages do not state the requested compliance classifications.