MPX2202GP vs MPX2202DP Karşılaştırma
Ayrıntılı yan yana karşılaştırma MPX2202GP tarafından NXP Semiconductors ve MPX2202DP tarafından NXP SemiconductorsAnahtar özellikleri, elektriksel parametreleri, ambalajı, yaşam döngüsü durumu, fiyatlandırma ve mevcudiyeti karşılaştırarak tasarım gereksinimleriniz için en iyi bileşeni belirleyin.
Özellik Karşılaştırması
| Parametre | MPX2202GP | MPX2202DP |
|---|---|---|
| Marka | NXP Semiconductors | NXP Semiconductors |
| Kategori | Pressure Sensors | Pressure Sensors |
| Yaşam Döngüsü Durumu | Aktif | Aktif |
| Pressure Type | Vented Gauge | Differential (dual port, tube inlet) |
| Operating Pressure Range | 0 kPa to 200 kPa (0 to 29.01 PSI) | — |
| Maximum Overload Pressure | [DATA_NEEDED: maximum overload pressure] | — |
| Çıkış Gerilimi | 0 mV to 40 mV (at 10 V excitation) | — |
| Besleme Gerilimi | 10 V DC nominal | 10 V typical |
| Besleme Akımı | [DATA_NEEDED: supply current] | — |
| İşletim Sıcaklığı | -40 C to +125 C [DATA_NEEDED: confirm from datasheet curves] | -40 C to +125 C [DATA_NEEDED: confirm exact op-temp range from datasheet] |
| Port Size | Male, 0.19 in (4.93 mm) Tube | — |
| Paket / Kas | 4-SIP Top Port Module | 4-SIP Module (Case 867C) |
| Termination Style | Through-Hole (PCB) | — |
| Accuracy | [DATA_NEEDED: linearity / accuracy specification] | — |
| Media Compatibility | Dry air or non-corrosive gases (per datasheet) | — |
| Compensation | On-chip temperature compensated and calibrated | — |
| Montaj Türü | Through Hole | Through-hole (4-SIP tube inlet) |
| RoHS Durumu | [DATA_NEEDED: RoHS compliance] | RoHS compliant |
| Pressure Range | — | 0 to 200 kPa (0 to 29.01 PSI) |
| Full-Scale Span | — | 40 mV typical at 10 V supply |
| Offset | — | 0 mV typical |
| Linearity | — | 1.0% typical |
| Pressure Hysteresis | — | 2.0% maximum |
| Temperature Compensated Range | — | 0 C to 85 C |
| Port Type | — | Dual tube, male, 0.19" (4.93 mm) tube |
| Çıkış Türü | — | Analog differential voltage |
| Technology | — | Silicon piezoresistive, on-chip temperature compensated and calibrated |