ICS2305M-1T - 133MHz Zero-Delay PLL Buffer | Renesas
MPN: ICS2305M-1T ✓ AktifICS2305M-1T Genel Bakış
A zero-delay buffer is a clock-integrity device that compensates for propagation delay introduced by a clock network. It can include a phase-locked loop, commonly called PLL mode, while also providing a bypass path. PLL-based clock distribution helps align multiple output transitions and reduce output-to-output skew. The ICS2305M-1T therefore belongs to the hierarchy of clock buffer, clock distribution IC, timing control IC, and semiconductor.
The primary electrical feature is operation up to 133 MHz. CMOS and TTL-compatible outputs allow the buffer to interface with logic families whose input thresholds differ from the internal clock-driver supply. Low-skew operation is valuable when a system must deliver related clocks to multiple sequential circuits, including memory controllers, communication equipment, data converters, and embedded processors. The bypass function provides a practical option when the design does not require PLL correction.
The ICS2305M-1 uses a PLL-based zero-delay architecture to control clock-edge alignment. In PLL mode, the internal loop adjusts the output phase to compensate for clock-distribution delay; in bypass mode, the clock is conveyed without active PLL phase correction. This architecture makes the device useful when a design requires both frequency-domain distribution and tighter control of clock-to-clock phase relationships. Operating limits, supply voltage details, output count, and timing characteristics should be confirmed in the manufacturer datasheet before release.
Typical applications include processor clock distribution, peripheral clock fanout, communications-interface clocking, data-acquisition systems, and test-and-measurement equipment. In each case, the device can provide local buffering so that clock routing does not rely entirely on the source device's output capability. The 133 MHz ceiling makes it appropriate for systems operating at or below that clock rate rather than modern multi-gigahertz processor interfaces.
PCB implementation requires careful treatment of the clock input and every clock output as high-speed signals. Keep traces short, provide a continuous ground reference, route outputs away from noisy switching nodes, and place decoupling capacitance close to the supply pins. The 8-pin SOIC footprint simplifies assembly, but its exposed lead geometry and limited routing area demand controlled fanout to minimize trace-length mismatch and preserve low-skew performance.
This product record combines the exact ordering code, operating class, frequency, logic compatibility, bypass capability, package dimensions, and practical PCB guidance with a transparent comparison framework. It also distinguishes the tape-and-reel ordering variant from the broader ICS2305M-1 device and identifies replacement candidates only when pin, package, and functional compatibility can be established.
Drop-in alternatifler için ICS2305M-1T — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.
Bu ürüne yer değiştirme seçenekleri mevcut değil.
Alternatifleri Talep EdinICS2305M-1T Özellikler
| Product Type | Fanout Buffer (Distribution), Zero Delay Buffer IC |
| Maximum Frequency | 133 MHz |
| Number of Circuits | 1 circuit |
| PLL | Yes, with bypass |
| Input Type | Clock |
| Çıkış Türü | CMOS or TTL |
| Besleme Gerilimi | 3.3 V |
| Paket | 8-SOIC |
| Package Width | 3.90 mm |
| Package Length | 0.154 inch |
| Montaj Türü | Surface mount |
| Shipping Configuration | T tape-and-reel configuration |
ICS2305M-1T 0.154 inch Pin Yapısı Kılavuzu
ICS2305M-1T (0.154 inch paket) için pin yapısı. Pin numaralandırma, işlevleri ve bağlantı şemaları üretici veri kitapçığında tanımlanmıştır. Doğru ayak ve soldurma kılavuzları için onu referans alın.
Ayrıntılı pin çıkış verisi mevcut değil: ICS2305M-1T.
Aşağıdaki veri sayfası tam pin konfigürasyonu için.
Tipik Uygulamalar
ICS2305M-1T için uygundur 6 uygulamas: Processor Clock Fanout, Communications Clock Distribution, Data Converter Clocking, Industrial Control and Automation, Test and Measurement Equipment, Peripheral and Memory Clock Trees.
Processor Clock Fanout
The ICS2305M-1T can distribute a clock from a central oscillator or controller to several sequential loads when the operating rate is 133 MHz or lower. Its PLL-based zero-delay architecture is useful for controlling phase alignment across the local clock network, while bypass mode offers an alternative clock path when phase compensation is unnecessary. The 8-SOIC package allows placement close to the clock-consuming circuitry, reducing dependence on long system-level routing. Designers should use the manufacturer pin and timing tables to confirm output loading, bypass state, propagation behavior, and whether output-to-output skew meets the processor interface requirement.
Communications Clock Distribution
In communications equipment, the ICS2305M-1T can provide a local 133 MHz-class clock distribution stage for interface controllers, transceivers, and digital signal-processing sections. A PLL-based buffer can compensate for delay accumulated through board traces and connector paths, making it useful when closely related output edges are required. CMOS or TTL-compatible outputs broaden its usefulness across mixed logic interfaces. The implementation should keep clock traces short, provide a solid ground reference, isolate the device from high-current switching nodes, and confirm the usable frequency and skew behavior against the exact clocking architecture of the communications system.
Data Converter Clocking
The ICS2305M-1T is applicable where an ADC or DAC requires a clean, phase-consistent sampling or update clock. Its zero-delay PLL function can align a distributed clock relative to the source, reducing phase variation introduced by routing and loading. The 133 MHz maximum frequency covers common intermediate-rate conversion systems while keeping the implementation compatible with an 8-pin SOIC footprint. For best results, place the buffer near the converter clock input, use short symmetric routes, maintain a continuous reference plane, and verify setup and hold timing using the converter's own clock requirements.
Industrial Control and Automation
Industrial control systems often distribute a common clock among processors, data converters, communication links, and programmable logic. The ICS2305M-1T can act as a low-skew distribution buffer at clock rates up to 133 MHz, helping maintain controlled relationships among related signals. Its PLL-with-bypass architecture permits active phase correction or a simpler pass-through mode, depending on system requirements. Because industrial equipment may combine switching power stages with sensitive timing circuits, route the clock away from inductors, power switches, and high-current return paths, and validate timing margin across voltage and temperature conditions before production release.
Test and Measurement Equipment
The ICS2305M-1T can provide clock fanout inside test and measurement instruments that synchronize multiple acquisition, conversion, or processing sections. A zero-delay PLL buffer is useful when cable or board-routing delay would otherwise create inconsistent phase relationships between distributed clocks. At a maximum frequency of 133 MHz, the device fits instrumentation requiring deterministic local distribution rather than extremely high-speed serial clocking. Place the buffer close to the loads to limit propagation variation, preserve a continuous ground plane under the clock routes, and use the manufacturer timing information to establish allowable loading and edge-quality conditions.
Peripheral and Memory Clock Trees
The ICS2305M-1T can act as a local clock-tree element between a system timing source and peripheral, memory, or programmable-logic loads. Its one-circuit zero-delay distribution function supports clock routing up to 133 MHz, while CMOS or TTL-compatible outputs accommodate conventional digital logic interfaces. PLL mode may help compensate for trace and load-related phase error in compact boards where route lengths cannot be made perfectly equal. Engineers should assign outputs and bypass control strictly from the pin-description table, keep the footprint compact, and confirm output count and timing against the actual load count before schematic capture.
Mühendislik referans verileri: ICS2305M-1T — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.
Seçim Kılavuzu
Tasarım Notları
Treat the clock input and every clock output as controlled-impedance, high-speed signals. Use a continuous ground plane beneath the routes, minimize stubs and vias, and place the ICS2305M-1T close to the load being clocked. Match route lengths where output-to-output phase relationships are important, and separate clock traces from switching-node and high-current power paths.
Do not assume that any zero-delay buffer with an 8-SOIC package is interchangeable. Verify the clock-input pin, output pins, bypass-control pin, supply connections, ground connections, output polarity, and operating frequency. In particular, a generic buffer may differ in enable polarity, output count, phase behavior, or timing even when its package and headline frequency appear similar.
Place the manufacturer-recommended bypass capacitance as close as practical to the supply and ground pins. Keep the loop formed by the capacitor, supply trace, and ground return compact to limit inductive noise. Because the device contains a PLL, stable local supply and reference return paths are particularly important; avoid sharing narrow supply necks with unrelated switching loads.
Account for capacitive loading, output-edge degradation, and propagation-delay differences when selecting fanout ratios and branch topology. PCB pad and trace capacitance, connector loading, and receiver thresholds can affect usable skew even when the nominal frequency is below 133 MHz. Validate the completed routing with the intended load and evaluate bypass mode separately because it may not provide the same phase correction as PLL mode.
Uyumluluk Bilgisi
The device is a clock and timing IC; automotive qualification and environmental compliance declarations were not identified. Lead-free and halogen-free status remain unknown.