LT1130CNW - 5V RS-232 Transceiver | Analog Devices | 28-PDIP
MPN: LT1130CNW ✗ Son Kullanım ZamanıLT1130CNW Genel Bakış
An RS-232 transceiver is an interface IC that combines line drivers, line receivers, and the electrical protection characteristics needed for RS-232 communication. The LT1130CNW belongs to the broader line-driver and line-receiver hierarchy, placing it within interface ICs used to connect data-processing equipment to computers, terminals, controllers, and industrial communication equipment. Its 5V-oriented design is suited to systems where logic-side supply voltage and RS-232 interface requirements are compatible.
The LT1130CNW integrates five drivers and five receivers in one package. This channel count supports equipment that needs several RS-232 ports or a mixture of transmit and receive lines. Its low-power orientation is useful where the design objective is to reduce interface-circuit energy use while maintaining established RS-232 behavior. The exact propagation delay, slew rate, input capacitance, output protection, and operating-temperature limits must be confirmed from the manufacturer datasheet before a new design is released.
The device belongs to the Analog Devices and Linear Technology RS-232 interface family. Linear Technology originally marketed the LT1130 series, while current distributor records identify LT1130CNW as an Analog Devices Inc. product. The N suffix identifies the industrial-temperature package treatment, while W identifies the 28-pin plastic DIP configuration. These suffix conventions should be checked against the ordering information before substituting another package or grade.
Typical applications include multi-channel RS-232 ports in industrial controllers, test equipment, data acquisition systems, embedded serial interfaces, and legacy peripheral connectivity. A multi-drop or multi-port design can use the integrated drivers and receivers to reduce board area, although system-level considerations such as cable length, ground reference, connector protection, and signal integrity remain important.
The principal design consideration is confirming every electrical limit against the correct LT1130 datasheet revision. Designers should verify supply voltage, driver output levels, receiver thresholds, input capacitance, shutdown or enable behavior where applicable, and package pin assignments. Place bypass capacitance close to the supply pins and provide connector-side protection appropriate to the installation environment.
This page consolidates the exact package and channel-count information, comparison dimensions, application guidance, and replacement-screening criteria needed to evaluate LT1130CNW. Because only the exact MPN and general interface description are documented here, unspecified electrical values are clearly marked rather than guessed, enabling engineering review without introducing unsupported electrical claims.
Drop-in alternatifler için LT1130CNW — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.
LT1130CN
✅ Yerleştirme ⚠️ Onaylanmamış Özellikler📋 Katalogda Olmayan Referans Alternatifi
LT1130IN
✅ Yerleştirme ⚠️ Onaylanmamış Özellikler📋 Katalogda Olmayan Referans Alternatifi
LT1130CNW Özellikler
| Product Type | 5/5 RS-232 transceiver |
| Driver Count | 5 drivers |
| Receiver Count | 5 receivers |
| Nominal Supply Voltage | 5 V |
| Interface Standard | RS-232 |
| Paket | 28-pin plastic dual inline package (28-PDIP) |
| Package Pin Count | 28 pins |
| Montaj Türü | Through-hole |
| RoHS Durumu | unknown |
| REACH Status | unknown |
| AEC-Q100 Qualification | not_applicable |
LT1130CNW 28 pins Pin Yapısı Kılavuzu
LT1130CNW (28 pins paket) için pin yapısı. Pin numaralandırma, işlevleri ve bağlantı şemaları üretici veri kitapçığında tanımlanmıştır. Doğru ayak ve soldurma kılavuzları için onu referans alın.
Ayrıntılı pin çıkış verisi mevcut değil: LT1130CNW.
Aşağıdaki veri sayfası tam pin konfigürasyonu için.
Tipik Uygulamalar
LT1130CNW için uygundur 6 uygulamas: Industrial RS-232 Controller Interface, Multi-Channel Data Acquisition Equipment, Test and Measurement Console, Legacy Peripheral Connectivity, Embedded Serial Communication Hub, Instrumentation and Diagnostics Port.
Industrial RS-232 Controller Interface
The LT1130CNW fits industrial controllers that need several RS-232 ports implemented in one through-hole package. Its five drivers and five receivers support a mix of command outputs and status inputs without requiring a separate IC for every signal direction. A designer can place the transceiver close to the connector and route protected serial lines to the logic section. Before release, confirm supply-voltage tolerance, logic thresholds, propagation delay, operating-temperature limits, and the complete 28-pin assignment from the manufacturer datasheet. The main benefit is consolidation; the trade-off is a larger through-hole footprint and a fixed five-by-five channel organization that may leave unused channels when the system needs fewer lines.
Önerilen
Multi-Channel Data Acquisition Equipment
The LT1130CNW is suitable for laboratory and industrial data-acquisition equipment that must exchange commands and measurements across multiple RS-232 links. Five driver channels can communicate with external controllers, while five receiver channels can collect responses or status signals from peripherals. The integrated arrangement can shorten board routing compared with many discrete driver and receiver packages. In this application, place the transceiver near the interface connector, provide local supply bypassing, and consider connector-side protection against external cables. Verify driver slew rate, receiver threshold, maximum data rate, and channel timing against the manufacturer datasheet before selecting it for high-speed or long-cable installations.
Önerilen
Test and Measurement Console
The LT1130CNW can support legacy RS-232 connectivity in test consoles, programmable instruments, and service interfaces. Its 5V RS-232 transceiver arrangement provides five transmit and five receive functions, allowing one device to manage several instrument-control paths when the test architecture requires them. The through-hole 28-PDIP package is straightforward to assemble and repair on larger or prototype boards. A practical design should place power decoupling at the device, route outputs away from sensitive analog sections, and include protection at user-accessible connectors. Confirm that every connected test peripheral uses compatible logic levels, grounding, and signal polarity before production use.
Önerilen
Legacy Peripheral Connectivity
The LT1130CNW is appropriate for embedded systems that retain RS-232 links to printers, scales, programmers, or service equipment. Five driver and five receiver channels provide capacity for several peripheral connections or additional control and status lines on a single package. Designers should use the lowest supported supply voltage, observe the datasheet's absolute-maximum limits, and confirm that the ground reference between the two systems is compatible. Long cable runs increase exposure to electrostatic discharge and industrial interference, so connector-side protection and a short, properly referenced return path are as important as the IC itself. Validate timing and receiver thresholds for the slowest connected peripheral before installing the design.
Önerilen
Embedded Serial Communication Hub
The LT1130CNW can serve as the interface section of an embedded communication hub that needs multiple bidirectional RS-232 paths. Its paired five-channel implementation simplifies organization when control traffic flows outward on drivers and incoming peripheral responses arrive on receivers. The 28-PDIP package suits through-hole control boards and legacy industrial platforms where surface-mount assembly is not required. The designer should verify whether all channels remain active continuously or whether the family supports a shutdown control, because unused-channel behavior affects standby power and board noise. Correct decoupling, defined cable shields, connector protection, and compatible signal grounding are essential for reliable operation in electrically noisy equipment.
Önerilen
Instrumentation and Diagnostics Port
The LT1130CNW can be used for diagnostic and configuration ports on industrial instruments where several RS-232 lines share a common interface. The five receivers allow status, alarm, and acknowledgment information to be monitored, while five drivers provide command and control outputs. This arrangement is useful when a legacy backplane already allocates a 28-pin DIP position. Layout should keep the transceiver and protection components away from precision analog circuitry, and firmware should account for asserted and inactive driver states on unused channels. Before production, verify receiver input behavior, data-rate limits, supply current, operating temperature, and all absolute-maximum ratings against the manufacturer datasheet.
Önerilen
Önerilen Ürünler Özeti
Mühendislik referans verileri: LT1130CNW — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.
Seçim Kılavuzu
Tasarım Notları
Use the manufacturer package drawing to define the 28 through-hole footprint before PCB release, including row spacing, drill diameter, and pin-1 orientation. The available product records confirm a 28-PDIP package but do not provide a complete land pattern or dimensioned drawing. Do not infer the footprint from a generic DIP outline; cross-check mechanical dimensions, lead pitch, and pin numbering against the LT1130 datasheet package drawing.
Follow the manufacturer recommendation for supply bypassing and place the required capacitor directly between the LT1130CNW supply and ground pins. Keep the loop area small and route the return to the device ground reference rather than through a distant connector ground. Confirm the permitted supply range and decoupling requirement in the manufacturer datasheet, because the product summaries establish 5V operation but do not state the minimum or maximum voltage or capacitor value.
Do not treat any RS-232 transceiver as automatically interchangeable with LT1130CNW. A valid replacement must match the 28-PDIP footprint, pin functions, five-driver and five-receiver arrangement, supply voltage, logic thresholds, timing, and package temperature grade. After substitution, check driver polarity, receiver input thresholds, unused-channel behavior, and protection requirements. Use the manufacturer pin-description table rather than inferring connections from channel count alone.
For cables longer than short bench leads, place the transceiver close to the connector and route protected RS-232 traces away from clocks, switching supplies, and sensitive analog inputs. Provide a low-impedance ground reference compatible with both connected systems and include connector-side transient protection designed for the installation environment. These measures reduce cable-borne noise and electrostatic-discharge risk before signals reach the LT1130CNW receiver inputs.
Uyumluluk Bilgisi
The exact-part records do not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. The industrial N package suffix does not by itself establish environmental or automotive qualification.