Analog Devices

MAX133CPL+ - 3.75-Digit 50ms DMM ADC | Analog Devices

MPN: MAX133CPL+ ✓ Aktif
40-pin PDIP Package
MOQ: 1 |

MAX133CPL+ Genel Bakış

The Analog Devices MAX133CPL+ is a 3.75-digit integrating analog-to-digital converter for digital multimeters and data-acquisition systems, with an internal resolution of ±40,000 counts, a 50 ms conversion time, and a 40-pin PDIP package. The additional guard digit supports autozero or tare operations on a 4000-count displayed reading at one-tenth of a displayed count.

An integrating ADC is a specialized data-conversion category used where a measured analog input is converted by integrating it over a defined interval. The MAX133 belongs to the broader ADC → data-converter IC → data-acquisition semiconductor hierarchy. Its integration-based measurement method and multi-pin mixed-signal interface are intended for precision panel-meter and multimeter products rather than general-purpose high-speed signal acquisition.

The primary verified characteristics are 3.75-digit resolution, ±40,000-count internal resolution, a 50 ms conversion cycle, and a commercial operating grade of 0°C to +70°C. Distributor listings identify the device as a 40-pin PDIP, through-hole part. The Analog Devices product page lists the MAX133 as a production 3.75-digit DMM circuit and provides the manufacturer datasheet, documentation, tools, and product-selection resources.

The MAX133 family is designed for integrating A/D converters used in 3.75-digit multimeters, data loggers, and weigh scales. The guard-digit feature is particularly useful for measurement systems that compensate offset or residual noise during autozero or tare operations. Because conversion completes in 50 ms, the device is appropriate for slow-changing measurements where stable integration is more useful than high sampling throughput.

A typical implementation places the MAX133 at the center of a digital meter front end, where it digitizes a conditioned differential measurement while supporting zero or tare correction. Its through-hole PDIP-40 package favors leaded, serviceable, and instrument-style assemblies. The package also requires careful routing of the analog input, reference, supply, digital-control, and display-interface signals across 40 pins.

The principal design consideration is that the MAX133 is a dedicated DMM conversion circuit rather than a general-purpose ADC. System designers should follow the manufacturer datasheet for input range, reference requirements, input impedance, excitation behavior, and display-interface timing. PCB layout should preserve a quiet analog signal path, provide stable reference routing, and place bypass and input-network components close to their associated pins.

This page consolidates verified manufacturer and distributor information, same-family replacement guidance, package and sourcing details, and practical selection considerations. It also distinguishes documented facts from electrical data that was not present in the supplied records, helping engineers make a preliminary design decision before reviewing the complete MAX133 datasheet.

Drop-in alternatifler için MAX133CPL+ — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.

Bu Serideki Variantlar

Yedek parça uyumlu olan aynı serideki modeller MAX133CPL+ (aynı form faktörü ve ayağa oturma) — farklı olan Temperature Grade, Package.

Maxim Integrated
Temperature Grade: Industrial
Package: 40-pin PDIP (PDIP-40), through-hole
İle Karşılaştır MAX133CPL+ →
Analog Devices
Temperature Grade: Commercial
İle Karşılaştır MAX133CPL+ →

MAX133EPL+

✅ Yerleştirme
📦 40-pin PDIP
Operating temperature increases from 0°C to +70°C to −40°C to +85°C, while the 50 ms conversion class is retained; functional characteristics are described as consistent with minor electrical differences.

📋 Katalogda Olmayan Referans Alternatifi

MAX131EPL+

✅ Yerleştirme ⚠️ Onaylanmamış Özellikler
Maxim Integrated
📦 40-pin PDIP
Dual-Slope ADC · 3.5 digits (single-chip DPM) · Differential · Integrated 7-segment / BCD decoder, high-current outputs · 40-pin PDIP (PDIP-40), through-hole · 40 · Through-Hole · DIP

Fiyat için iletişime geçin

Veri Şablonunu Görüntüle →

MAX132CPL+

✅ Yerleştirme ⚠️ Onaylanmamış Özellikler
📦 40-pin PDIP
Same 40-pin PDIP family format, while conversion timing differs from the MAX133's 50 ms conversion class by up to 30% for this related MAX13x variant.

📋 Katalogda Olmayan Referans Alternatifi

MAX130CPL+

✅ Yerleştirme ⚠️ Onaylanmamış Özellikler
📦 40-pin PDIP
Same 40-pin PDIP family format, while the conversion-timing class differs by as much as 30% from the MAX133's 50 ms conversion specification.

📋 Katalogda Olmayan Referans Alternatifi

MAX134CPL+

✅ Yerleştirme ⚠️ Onaylanmamış Özellikler
Analog Devices
📦 40-pin PDIP
Specialized 3.75-digit digital multimeter ADC · Proprietary method · Dual-slope · 1 channel · 20 samples/s · BCD · 3.75 digits · Commercial

Fiyat için iletişime geçin

Veri Şablonunu Görüntüle →

MAX133CPL+ Maksimum Değerlendirmeler & Elektriksel Özellikler

ADC Type Integrating A/D converter for 3.75-digit multimeters
Display Resolution 3.75 digits
Internal Resolution ±40,000 counts
Guard Digit 1 digit
Conversion Time 50 ms
Input Type Differential
Paket 40-pin PDIP
Montaj Türü Through-hole
Terminal Count 40 terminals
İşletim Sıcaklığı Aralığı 0°C to +70°C
Temperature Grade Commercial

MAX133CPL+ 40-pin pdip Pin Yapısı Kılavuzu

MAX133CPL+ (40-pin pdip paket) için pin yapısı. Bu analog bileşen, giriş, çıkış ve güç besleme pinleri içerir. Ofset null, telafi ve etkinleştirme pin yapılandırmaları için üretici veri kitapçığını referans alın. Sinyal işleme ve güç amplifikasyon devreleri için mükemmel bir bileşendir.

40-pin pdip paket pin çizelgesi için MAX133CPL+

Ayrıntılı pin çıkış verisi mevcut değil: MAX133CPL+.

Aşağıdaki veri sayfası tam pin konfigürasyonu için.

Tipik Uygulamalar

MAX133CPL+ için uygundur 6 uygulamas: Digital Multimeter Front End, Industrial Panel Meter, Data Logger and Recorder, Weigh-Scale Instrumentation, Bench Test and Measurement Instrument, Process Monitoring and Control.

🔧

Digital Multimeter Front End

The MAX133CPL+ is appropriate for the measurement engine of a digital multimeter because it provides 3.75-digit display resolution, ±40,000-count internal resolution, and a dedicated 50 ms conversion cycle. The guard-digit capability allows autozero or tare correction to one-tenth of a displayed count on a 4000-count reading. It can therefore support stable resistance, voltage, or current measurements when paired with a suitable front-end network, reference, display driver, and keyboard controller. The main design trade-off is its 0°C to +70°C commercial operating range; MAX133EPL+ may be preferable when operation down to −40°C is required.

🏭

Industrial Panel Meter

The MAX133CPL+ can serve as the A/D element in an industrial panel meter when the displayed quantity changes slowly and a stable integrated measurement is more important than high sampling speed. Its ±40,000-count internal resolution provides additional guard-digit resolution beyond the nominal 4000-count display, while the 50 ms conversion interval is practical for continuously refreshed panel indications. The circuit should be paired with an input conditioner and stable reference, and the layout must keep sensitive analog routing away from display and control signals. Its commercial 0°C to +70°C range suits controlled indoor equipment, but an extended-temperature variant may be needed in harsher industrial enclosures.

🖥️

Data Logger and Recorder

For a low-speed data logger, the MAX133CPL+ provides a dedicated path for converting conditioned analog measurements into a three-and-three-quarter-digit result. The ±40,000-count internal resolution and one-digit guard function make it useful when offset correction, autozero, or tare must be applied to a 4000-count displayed value. Its 50 ms conversion time supports periodic measurements without imposing the timing demands of a high-speed general-purpose ADC. Design work should verify the complete input and reference ranges from the manufacturer datasheet and account for the through-hole 40-pin package. The 0°C to +70°C rating must also be checked against the logger's enclosure temperature.

⚖️

Weigh-Scale Instrumentation

The MAX133CPL+ is suitable for a basic weigh-scale measurement channel when the bridge signal is conditioned into the converter's specified differential input range. The ±40,000-count internal resolution supports a 3.75-digit displayed result and provides guard-digit capacity for zeroing or tare operations, both of which are useful when load-cell offsets must be removed. A 50 ms conversion interval is appropriate for a stable, human-readable weight display rather than a high-speed sorting system. The implementation should follow the manufacturer's excitation, reference, and analog-filtering guidance, and it should include adequate settling time between range or zero changes.

📟

Bench Test and Measurement Instrument

The MAX133CPL+ can support the measurement channel of a bench instrument that displays calibrated DC values and does not require high-frequency sampling. Its dedicated 3.75-digit DMM architecture, 50 ms conversion time, and guard-digit capability simplify the relationship between the measured value and the displayed count. The through-hole PDIP-40 package is particularly convenient for prototype and instrument-style assemblies where component accessibility and hand rework are useful. Before final selection, engineers should verify the allowable input span, reference behavior, supply requirements, and error specifications because those details were not included in the supplied distributor records.

🌐

Process Monitoring and Control

The MAX133CPL+ is applicable to slow-changing process variables displayed by industrial monitoring equipment, provided its specified input and reference limits match the sensing system. The 50 ms conversion cycle provides frequent updates without requiring a rapid successive-approximation ADC, while the ±40,000-count internal resolution can improve resolution beyond the basic displayed count. Autozero or tare may be used to compensate sensor offset in a controlled measurement path. Because the device is commercial grade from 0°C to +70°C, enclosure heating or an extended-temperature MAX133-family option may be needed where ambient conditions exceed that range.

Önerilen Ürünler Özeti

MAX133EPL+ Same-family extended-temperature DMM converter option Kullanıldığı Yer: Digital Multimeter Front End, Industrial Panel Meter, Data Logger and Recorder, Weigh-Scale Instrumentation, Bench Test and Measurement Instrument, Process Monitoring and Control MAX134CPL+ Analog Devices Kullanıldığı Yer: Digital Multimeter Front End, Process Monitoring and Control MAX131EPL+ Maxim Integrated Kullanıldığı Yer: Industrial Panel Meter, Weigh-Scale Instrumentation MAX132CPL+ Related MAX13x conversion option Kullanıldığı Yer: Data Logger and Recorder MAX130CPL+ Related MAX13x converter for alternative timing requirements Kullanıldığı Yer: Bench Test and Measurement Instrument
What is the resolution of MAX133CPL+?
The MAX133CPL+ provides 3.75-digit display resolution and an internal resolution of ±40,000 counts. According to the Analog Devices MAX133 product page, the additional guard digit supports autozero or tare of a 4000-count displayed reading down to one-tenth of a displayed count. This architecture is intended specifically for precision digital multimeter and data-logging measurements.
How fast does the MAX133CPL+ perform an A/D conversion?
The MAX133CPL+ completes an A/D conversion in 50 ms. According to the Analog Devices MAX133 product page, this conversion time identifies the device as a dedicated integrating converter for 3.75-digit multimeters. It is therefore suited to slowly varying measurements that benefit from integration rather than general-purpose, high-speed data acquisition.
What package and mounting style does MAX133CPL+ use?
The MAX133CPL+ is supplied in a 40-pin PDIP package intended for through-hole mounting. This package information is confirmed by the DigiKey product listing and by the Vyrian component record, which identifies 40 terminals, a DIP package code, and through-hole mounting. The 40-pin footprint should be checked against the complete manufacturer pinout before PCB release.
Where can I download the MAX133CPL+ datasheet PDF?
The official MAX133 datasheet and product documentation are available from the Analog Devices product page at https://www.analog.com/en/products/MAX133.html. The page identifies the document as the MAX133 production 3.75-digit DMM circuit data sheet, revision 1, and provides links for data sheets, evaluation material, tools, and product-selection information.
Where can I find the MAX133CPL+ pinout?
The MAX133CPL+ pin assignment must be taken from the official MAX133 manufacturer datasheet on the Analog Devices product page. The supplied verified records confirm a 40-pin PDIP package but do not reproduce the individual pin names or numbering. Consequently, no public pin table is asserted here, and the schematic should not be released until all 40 pins are cross-checked against the manufacturer document.
What is the best drop-in replacement for MAX133CPL+?
The closest documented same-family choice is MAX133EPL+, which retains the MAX133 identity and 40-pin PDIP format while extending the commercial temperature grade to −40°C to +85°C. The supplied comparison data indicates consistent functional characteristics but also notes some electrical differences. Engineers should therefore review the manufacturer datasheet and verify the board footprint before treating it as an unqualified drop-in replacement.
Can MAX133EPL+ replace MAX133CPL+?
Yes, MAX133EPL+ is the strongest same-family replacement candidate because it uses the same 40-pin PDIP format and expands the operating range to −40°C to +85°C. FindIC describes its functional characteristics as consistent but notes electrical differences. Board-level substitution is therefore reasonable only after confirming the supply, reference, input-range, and timing requirements in the manufacturer data sheet.
What can replace MAX133CPL+ in a digital multimeter?
The MAX133EPL+ is the most practical replacement candidate for a MAX133CPL+-based digital multimeter because it preserves the 40-pin PDIP format and offers a wider temperature range. MAX131EPL+, MAX132CPL+, and MAX130CPL+ are additional members of the related MAX13x family, but their conversion timing and electrical characteristics may differ. The MAX133EPL+ should be preferred when exact functional continuity is the priority.
Is MAX133CPL+ the same as MAX134CPL+?
No. The Analog Devices MAX133 product page states that the MAX133 and MAX134 differ functionally, even though both belong to the 3.75-digit DMM converter family and use a 40-pin PDIP package. A matching package does not by itself establish electrical or pin-to-pin compatibility. MAX134 should be selected only when its specific input and interface behavior satisfy the target instrument design.
MAX133CPL+ vs MAX131EPL+ - which is better for a meter?
Choose MAX133CPL+ when a 50 ms conversion cycle is appropriate and the operating range of 0°C to +70°C is sufficient. MAX131EPL+ provides a wider −40°C to +85°C operating range and remains in the related MAX13x converter family, but the comparison records indicate that major parameters and timing differ. The final choice should follow the required conversion rate, environmental range, and complete electrical specification.
When should I choose MAX133CPL+ over MAX133EPL+?
Choose MAX133CPL+ when the instrument is intended for a 0°C to +70°C commercial environment and the verified 50 ms conversion time is acceptable. Choose MAX133EPL+ instead when the product must operate from −40°C to +85°C or when a broader qualified temperature range is valuable. The same 40-pin PDIP format makes both options relevant to the same mechanical design.
Where to buy MAX133CPL+ online?
The MAX133CPL+ can be purchased through multiple authorized distribution channels, including DigiKey, Mouser, and LCSC. The verified LCSC listing reports an in-stock price starting at US$36.0984, while DigiKey and Mouser provide inventory, pricing, and datasheet links. Purchase directly from the listing that can provide traceable stock, manufacturer documentation, and the required quantity.
What is the price of MAX133CPL+ as of 2026-10-28?
The verified starting price for MAX133CPL+ was US$36.0984 as of 2026-10-28 at LCSC. The Analog Devices product page separately lists a MAX133 list price starting from US$22.44, but that family-level figure may not correspond to the exact MAX133CPL+ commercial-grade order code. Distributor pricing, stock, and volume breaks can change after the stated date.
What is the lead time and stock status for MAX133CPL+?
The verified LCSC result identifies MAX133CPL+ as in stock, and DigiKey states that the part ships today for the listed order. A fixed factory lead time is not provided in the supplied records, so exact delivery timing should be confirmed with the selected distributor. XAIPART availability is represented as back-order because no explicit XAIPART inventory statement was supplied.
What are the key specifications of MAX133CPL+ that engineers should know?
The essential MAX133CPL+ specifications are 3.75-digit display resolution, ±40,000-count internal resolution, a 50 ms conversion time, differential input, and a 40-pin PDIP package. The Analog Devices product page also identifies a one-digit guard function for autozero or tare and a 0°C to +70°C commercial operating grade. Supply voltage, reference voltage, input range, and accuracy limits must be obtained from the manufacturer datasheet.
Is MAX133CPL+ suitable for industrial measurement and data logging?
The MAX133CPL+ is suitable for measurement systems that operate within 0°C to +70°C and require a dedicated 3.75-digit DMM converter. Its ±40,000-count internal resolution, guard-digit capability, and 50 ms conversion time support precision panel instruments, data loggers, and weigh scales. For wider environmental requirements, MAX133EPL+ provides a documented −40°C to +85°C alternative.

Mühendislik referans verileri: MAX133CPL+ — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.

Seçim Kılavuzu

Choose MAX133CPL+ when building a digital multimeter, panel meter, data logger, or weigh-scale interface that requires a dedicated 3.75-digit converter, ±40,000-count internal resolution, a guard digit, and a verified 50 ms conversion interval. It is the appropriate option for a 0°C to +70°C commercial environment. Choose MAX133EPL+ when the same mechanical format is needed with an extended −40°C to +85°C range. MAX131EPL+ is worth considering when its different timing and electrical characteristics better fit the measurement cycle, while MAX132CPL+ and MAX130CPL+ require explicit review of conversion speed and functional behavior. MAX134CPL+ is not a routine substitute because Analog Devices states that it differs functionally from MAX133. In every case, confirm the complete pin assignments, input range, reference requirements, supply arrangement, output coding, and error limits before approving a substitution.

Alternatiflerle Karşılaştırma

Parametre Bu Ürün MAX133EPL+ MAX131EPL+ MAX132CPL+ MAX130CPL+
Package 40-pin PDIP 40-pin PDIP - same 40-pin PDIP - same 40-pin PDIP - same 40-pin PDIP - same
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices

Ana Farklılayıcılar

  • Commercial-grade operating range with an extended-temperature family option (karşılaştırma:MAX133EPL+)
  • Documented 50 ms conversion time (karşılaştırma:MAX131EPL+)
  • Dedicated 3.75-digit DMM conversion architecture (karşılaştırma:MAX134CPL+)

Tasarım Notları

Route the differential measurement input, reference, and supply connections using the layout in the official MAX133 datasheet. Keep the input-network components close to their associated MAX133CPL+ pins, avoid sharing high-current paths with sensitive analog traces, and provide a quiet return path. Because the verified records establish a 40-pin PDIP but do not provide the complete pin table, do not finalize the PCB until all pin numbers and exposed functions have been checked against the manufacturer document.

Treat the MAX133 as an integrating measurement converter rather than a high-speed ADC. Its 50 ms conversion time is suited to stable, slowly changing signals, so input filtering should suppress ripple without creating excessive settling delay between readings. Verify that the chosen filter preserves the required measurement bandwidth and that the reference remains stable throughout each conversion interval. Use the manufacturer's input, reference, and grounding guidance when setting the filter and acquisition timing.

Do not treat a shared 40-pin PDIP footprint as proof that every MAX13x or MAX134 variant is electrically interchangeable. The Analog Devices product page states that MAX133 and MAX134 differ functionally, while comparison records indicate differences between MAX131, MAX133, and MAX134. Before substitution, compare input range, supply arrangement, reference, conversion timing, output coding, and control signals directly against the manufacturer datasheets for both devices.

Power bypass placement is especially important in a meter because the analog input, reference, display, and control circuitry may share a board area. Follow the exact supply-pin and component-selection recommendations in the MAX133 datasheet, including the required capacitor types, voltage ratings, and effective capacitance. Place high-frequency bypass capacitors at the relevant pins and keep supply routing away from the differential input and reference nodes to minimize conversion errors and displayed-digit instability.

Uyumluluk Bilgisi

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Kadmiyumdan Arınmış
Unknown
Klorofillerden Arınmış
Unknown
Çatışma Minerali
Unknown

The supplied verified records do not explicitly state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is recorded as not applicable because the MAX133CPL+ is identified as a commercial-grade DMM circuit rather than an automotive-qualified device.

Veri doğrulanma tarihi: 2026-10-28 — XAIPART bileşen mühendislik ekibi tarafından doğrulanmış ve derlenmiş veri

İlgili Aramalar

MAX133CPL+ MAX133CPL+ datasheet PDF Analog Devices MAX133CPL+ MAX133 3.75 digit ADC MAX133CPL+ 40-pin PDIP MAX133CPL+ digital multimeter ADC MAX133CPL+ vs MAX133EPL+ MAX133CPL+ drop-in replacement MAX133CPL+ price buy MAX133CPL+ online MAX133CPL+ conversion time MAX133CPL+ pinout MAX133CPL+ lead time MAX133CPL+ panel meter MAX133CPL+ data logger

İlgili Bileşenler ve Terimler

Analog Devices MAX133CPL+ MAX133EPL+ MAX131EPL+ MAX132CPL+ MAX130CPL+ MAX134CPL+ MAX133 integrating analog-to-digital converter ADC data-converter IC digital multimeter DMM circuit 3.75-digit ADC ±40,000-count resolution guard digit 50 ms conversion time differential input PDIP-40 through-hole package data logger weigh scale autozero tare correction power management
Hızlı Teklif RFQ
Detayları tam doldurun — satış ekibimiz 24 saat içinde yanıt verecek
Parça Numarası Üretici Paket QTY Hedef Fiyat Genişletilmiş
✓
Teklif gönderildi!

24 saat içinde e-postanıza yanıt vereceğiz

1
RFQ Gönderildi
2
Teklif Alındı
3
Sipariş Yerleştirildi
4
Ödeme
5
Gönderildi
6
Teslim Edildi
RFQ Detaylarını Görüntüle