MCP3426A6-E/MS - 16-Bit Dual-Channel Delta-Sigma ADC | Microchip
MPN: MCP3426A6-E/MS ✓ AktifMCP3426A6-E/MS Genel Bakış
A delta-sigma ADC is a voltage-regulating class of data-converter IC that continuously samples an analog input and uses digital noise shaping and decimation to produce a high-resolution result. Within the semiconductor hierarchy, the MCP3426A6-E/MS is a delta-sigma analog-to-digital converter, commonly called a delta-sigma ADC. Its continuous internal architecture and integrated reference favor accurate low-frequency measurements rather than high-bandwidth waveform capture.
The MCP3426 family provides two differential input channels, up to 16-bit resolution, and a precision 2.048 V reference. The A6 speed grade operates at 15 samples per second, providing a deliberate balance between conversion rate, noise performance, and power-efficient precision measurement. Differential inputs also allow direct sensing of small voltages across a sensor bridge, thermocouple, or current-shunt element while rejecting common-mode disturbance.
The integrated 2.048 V reference establishes a ±2.048 V differential input range and reduces the need for an external precision reference. The device supports both 3.3 V and 5 V operation, allowing integration into embedded instrumentation and industrial measurement systems. Its -40°C to +125°C operating range supports applications where temperature drift and long-term stability are important, provided the board design controls input noise, grounding, and reference-quality power.
Typical uses include bridge-based pressure and force sensing, current measurement with shunt resistors, industrial process monitoring, battery-cell voltage acquisition, and low-frequency instrumentation. Differential excitation can reject power-supply ripple and ground offsets when the sensor return is connected to the converter's negative input. The 15 sps conversion rate is most appropriate for slowly changing signals rather than audio-band or high-speed industrial waveform acquisition.
Design around the differential input architecture by keeping sensor traces away from switching nodes and placing input filtering close to the MSOP pins. Confirm the external resistor, capacitor, and common-mode input requirements from the manufacturer datasheet. For a new design, verify startup settling, conversion timing, digital interface levels, and package-specific layout before committing the PCB footprint.
Drop-in alternatifler için MCP3426A6-E/MS — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.
MCP3426A0-E/MS
✅ YerleştirmeFiyat için iletişime geçin
Veri Şablonunu Görüntüle →MCP3426A2T-E/MS
✅ Yerleştirme📋 Katalogda Olmayan Referans Alternatifi
MCP3426A6-E/MS Maksimum Değerlendirmeler & Elektriksel Özellikler
| ADC Type | 16-bit delta-sigma ADC |
| Number of Input Channels | 2 differential channels |
| Çözünürlük | Up to 16 bits |
| Conversion Rate | 15 samples/s |
| Input Architecture | Differential input |
| Internal Reference Voltage | 2.048 V |
| Differential Input Range | ±2.048 V |
| Besleme Gerilimi | 3.3 V or 5 V |
| İşletim Sıcaklığı Aralığı | -40°C to +125°C |
| Paket | 8-pin MSOP |
| Montaj Türü | Surface mount |
| Noise Class | Low-noise converter |
| Accuracy Class | High-accuracy converter |
| Converter Family | MCP3426 series |
| Automotive Classification | Automotive |
MCP3426A6-E/MS 8-pin msop Pin Yapısı Kılavuzu
MCP3426A6-E/MS (8-pin msop paket) için pin yapısı. Bu analog bileşen, giriş, çıkış ve güç besleme pinleri içerir. Ofset null, telafi ve etkinleştirme pin yapılandırmaları için üretici veri kitapçığını referans alın. Sinyal işleme ve güç amplifikasyon devreleri için mükemmel bir bileşendir.
Ayrıntılı pin çıkış verisi mevcut değil: MCP3426A6-E/MS.
Aşağıdaki veri sayfası tam pin konfigürasyonu için.
Tipik Uygulamalar
MCP3426A6-E/MS için uygundur 6 uygulamas: Bridge-Based Pressure Sensing, Shunt Current Measurement, Industrial Process Monitoring, Battery-Cell Voltage Acquisition, Precision Temperature Acquisition, Low-Noise Instrumentation.
Bridge-Based Pressure Sensing
The MCP3426A6-E/MS fits resistance-bridge sensors because its two differential channels support sensing of small excitation-induced voltage changes while rejecting much of the common-mode voltage present across the bridge. The 16-bit resolution, 2.048 V internal reference, and ±2.048 V differential range provide a precise conversion scale for pressure, load, and position elements. At 15 samples/s, the converter suits slow physical changes rather than dynamic vibration. Place input filtering close to the MSOP pins, reference the measurement to the bridge return, and verify excitation, common-mode limits, and sensor output amplitude against the manufacturer electrical tables.
Önerilen
Shunt Current Measurement
The MCP3426A6-E/MS can measure the differential voltage produced by a current shunt, providing a compact front end for power-supply, battery, and energy-monitoring systems. Differential input architecture reduces sensitivity to common-mode voltage, while the 2.048 V reference and 16-bit conversion establish the measurement scale. The 15 samples/s rate is appropriate for current changes that evolve over seconds rather than fast switching waveforms. Choose the shunt value so its worst-case signal remains inside the ±2.048 V input range, and route the Kelvin connection directly to the ADC to avoid copper-drop errors.
Önerilen
Industrial Process Monitoring
The MCP3426A6-E/MS is appropriate for slow industrial variables such as tank level, valve position, pressure, and temperature transducer outputs. Its two differential channels permit two related measurements without duplicating the converter, while the -40°C to +125°C operating range supports demanding ambient environments. The 16-bit delta-sigma architecture emphasizes precision over conversion speed, making 15 samples/s suitable for supervisory and control-loop acquisition. Add channel-specific input filters, maintain consistent grounding, and validate isolation or protection requirements separately because the ADC package itself does not replace industrial surge protection.
Önerilen
Battery-Cell Voltage Acquisition
The MCP3426A6-E/MS can digitize slow battery or energy-storage cell voltages when the sensing front end keeps the differential signal within ±2.048 V. The internal 2.048 V reference removes the need for a separate reference circuit, and the 16-bit resolution supports fine measurement granularity across multiple monitored cells. Its 15 samples/s rate is adequate for balancing systems, state-of-charge monitoring, and long-duration trend acquisition. The application still needs an appropriate divider or isolation network, and measurement accuracy depends on the reference behavior, input leakage, PCB leakage, and calibration strategy described in the manufacturer documentation.
Önerilen
Precision Temperature Acquisition
The MCP3426A6-E/MS suits thermocouple or resistance-based temperature measurement when the converted signal changes slowly and differential input conditioning is used. Its 16-bit resolution and 2.048 V reference support precision digitizing of low-level sensor voltages, while the 15 samples/s rate provides periodic updates for thermal control or logging. Cold-junction compensation, sensor-specific linearization, input protection, and open-circuit detection remain external functions that must be implemented according to the sensor interface requirements. The wide -40°C to +125°C device range supports industrial ambient conditions, but total error must include sensor and front-end contributions.
Önerilen
Low-Noise Instrumentation
The MCP3426A6-E/MS is appropriate for laboratory and field instrumentation that digitizes low-level differential signals at a controlled rate. Its delta-sigma conversion, 16-bit resolution, internal reference, and low-noise positioning favor accurate readings from strain gauges, current shunts, and resistive bridges. The 15 samples/s throughput is intentionally modest, so it should not be selected for sampling fast transients. For best results, use shielded sensor wiring, a clean analog ground, short input traces, and filtering selected for the required bandwidth rather than indiscriminately slowing the response.
Önerilen
Önerilen Ürünler Özeti
Mühendislik referans verileri: MCP3426A6-E/MS — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.
Seçim Kılavuzu
Alternatiflerle Karşılaştırma
| Parametre | Bu Ürün | MCP3426A0-E/MS | MCP3426A2T-E/MS |
|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 8-pin MSOP | 8-pin MSOP | 8-pin MSOP |
| ADC Architecture | 16-bit delta-sigma ADC | 16-bit delta-sigma ADC | 16-bit delta-sigma ADC |
| Input Channels | 2 differential channels | 2 differential channels | 2 differential channels |
| Speed-Grade Suffix | A6 | A0 | A2 |
Ana Farklılayıcılar
- Faster A6 conversion grade within the same MCP3426 family (karşılaştırma:MCP3426A0-E/MS)
- Two-channel differential conversion in an 8-pin MSOP (karşılaştırma:MCP3426A2T-E/MS)
- Integrated precision reference simplifies the measurement scale (karşılaştırma:MCP3426A0-E/MS)
Tasarım Notları
Route the two differential input channels as short, matched traces and place any input filtering capacitors close to the MSOP pins. Keep the sensor return and signal trace together to reduce differential pickup from common-mode sources. Route the digital interface away from the analog inputs, and keep switching-regulator traces and inductors out of the input path. The 2.048 V internal reference makes supply decoupling and analog-ground routing especially important for repeatable measurements.
Do not assume that the ±2.048 V differential range permits unrestricted input-pin voltages. Check absolute maximum input limits, common-mode range, allowable source impedance, and the effect of input overrange in the Microchip datasheet. For shunt and bridge circuits, ensure worst-case excitation, tolerance, and transient excursions remain within the converter's operating limits.
Choose input filters for the actual sensor bandwidth rather than using excessive capacitance that prevents the differential inputs from settling. Confirm settling requirements against the selected conversion mode and sample interval. For slow measurements, additional filtering can reduce high-frequency noise; for multiplexed or rapidly changing channels, verify the complete acquisition sequence instead of optimizing one channel in isolation.
Uyumluluk Bilgisi
The product listing identifies the device as automotive, but explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations were not identified. Confirm the applicable declarations using the manufacturer's product documentation before production release.