Analog Devices

AD604ARZ - Dual 40MHz Ultralow Noise VGA | Analog Devices

MPN: AD604ARZ ✓ فعال
5 V Vdss 24-lead SOIC, 7.50 mm width Package
MOQ: 1 |

AD604ARZ جائزہ

Analog Devices AD604ARZ is a dual-channel, ultralow-noise variable gain amplifier designed for time-based gain control. Each channel provides a 40 MHz bandwidth and uses a linear-in-decibel gain-control architecture, making the device suitable for ultrasound receivers and other wideband signal chains that require precise, continuously adjustable gain. The device is offered in a 24-lead SOIC package and operates from a 5 V supply over a -40°C to +85°C temperature range.

A variable gain amplifier, or VGA, is a signal-conditioning amplifier whose gain changes under electronic control. A VGA belongs to the broader amplifier hierarchy and provides a practical compromise between signal amplification and controlled attenuation. The AD604ARZ uses separate gain-control paths for its two channels, allowing each receiver channel to be adjusted independently while preserving a consistent linear-in-dB response over the operating bandwidth.

The AD604 family is differentiated by its combination of wide bandwidth, low noise, and accurate variable gain. The manufacturer identifies the AD604 as an ultralow-noise, highly accurate dual-channel VGA optimized for ultrasound applications. Its 40 MHz bandwidth supports demanding analog signal paths, while the two-circuit configuration helps reduce system complexity when two independently controlled receiver channels are required.

Each amplifier channel contains an input stage, gain-control element, output stage, and gain-control pin. The gain-control interface allows an external controller to establish the desired attenuation level. Because the response is linear in decibels, a change in control voltage produces a proportional change in gain expressed in dB, which simplifies calibration across different signal levels and operating conditions.

Typical uses include ultrasound imaging receivers, medical diagnostic systems, communications equipment, instrumentation, and other wideband analog front ends that benefit from time-based gain adjustment. In an ultrasound system, the variable gain stage can accommodate the large dynamic range between near-surface and deep-tissue echoes while preserving the bandwidth needed for time-of-flight measurement.

When designing around the AD604ARZ, treat the gain-control network, power-supply bypassing, and analog signal routing as separate high-priority concerns. The dual-channel architecture simplifies systems requiring independent channel control, but successful implementation still depends on careful grounding, low-noise supply routing, and appropriate gain-control voltage ranges for the intended instrumentation.

This product record combines the manufacturer’s functional description with package, channel, bandwidth, supply, temperature, and environmental information. It also identifies the limited drop-in-replacement landscape, distinguishes tape-and-reel order codes from genuine electrical alternatives, and provides application and design guidance focused on using this dual 40 MHz VGA correctly.

کے لیے ڈراپ اِن متبادل AD604ARZ — یکساں پیکیج، پن سے پن مطابقت پذیر۔ مختلف پیکیج والے پرزے جن کے لیے PCB دوبارہ کام درکار ہو، شامل نہیں ہیں۔

اس پروڈکٹ کے لیے کوئی ڈراپ اِن متبادل دستیاب نہیں۔

متبادل کی درخواست کریں

AD604ARZ زیادہ سے زیادہ ریٹنگز اور برقی خصوصیات

Product Type Dual-channel variable gain amplifier
Number of Amplifier Circuits 2 circuits
Gain Control Characteristics Linear in dB
Bandwidth 40 MHz
سپلائی وولٹیج 5 V
آپریٹنگ درجہ حرارت رینج -40°C to +85°C
پیکیج 24-lead SOIC, 7.50 mm width
ماؤنٹنگ ٹائپ Surface mount
RoHS Compliance Compliant
REACH Compliance Compliant
Conflict Minerals Status DRC conflict-free undeterminable

AD604ARZ 24-lead soic, 7.50 mm width پن کنفیگریشن گائیڈ

AD604ARZ (24-lead soic, 7.50 mm width پیکیج) کے لیے پن کنفیگریشن۔ اس اینالاگ کمپوننٹ میں اِن پٹ، آؤٹ پٹ اور پاور سپلائی پنز شامل ہیں۔ آفسیٹ نل، کمپنسیشن اور اِن ایبل پن کنفیگریشنز کے لیے مینوفیکچرر کے ڈیٹا شیٹ سے رجوع کریں۔ سگنل کنڈیشننگ اور ایمپلیفائر سرکٹس کے لیے مثالی۔

AD604ARZ کے لیے 24-lead soic, 7.50 mm width پیکیج پن آؤٹ ڈایاگرام

کے لیے تفصیلی پن آؤٹ ڈیٹا دستیاب نہیں AD604ARZ.

رجوع کریں ڈیٹا شیٹ مکمل پن کنفیگریشن کے لیے۔

عام استعمالات

AD604ARZ کے لیے موزوں ہے 6 ایپلیکیشنs: Ultrasound Imaging Receiver, Medical Diagnostic Signal Chain, Communications Receiver Front End, Precision Instrumentation Amplification, Industrial Signal Conditioning, Test and Measurement Front End.

💊

Ultrasound Imaging Receiver

The AD604ARZ fits dual-channel ultrasound receiver front ends that require rapid, electronically controlled attenuation of echo signals. Its two amplifier circuits allow adjacent receive channels to be adjusted independently, while the 40 MHz bandwidth supports broad-band echo signals and linear-in-dB control simplifies gain calibration across different signal amplitudes. In a typical time-gain-control architecture, each channel accepts the transducer or receiver-chain signal and applies a control voltage representing the required attenuation. The dual structure reduces the number of separate VGA packages required for a two-channel receiver, although PCB layout must preserve independent channel isolation. Confirm the AD604 gain-control range, allowable input level, and output swing in the manufacturer data sheet before setting the receiver front end.

💊

Medical Diagnostic Signal Chain

The AD604ARZ is suitable for medical diagnostic and monitoring equipment that must process wideband analog signals with controllable attenuation. Its dual-channel arrangement supports paired acquisition paths, while the 40 MHz bandwidth and linear-in-dB response help preserve consistent signal relationships as gain is changed. In a diagnostic front end, the device can sit between a transducer or sensor interface and a downstream converter, with software or a control DAC adjusting gain as the signal amplitude varies. Because medical equipment also depends on stable references and low-noise supply rails, the gain-control source and analog ground return require careful layout. Verify medical-system requirements separately from device qualification; the available catalog information does not establish an AEC-Q100 automotive or medical certification status for this order code.

🌐

Communications Receiver Front End

The AD604ARZ can provide variable attenuation ahead of a communications receiver when received signal strength changes over a broad range. Its 40 MHz bandwidth accommodates high-speed analog channels, and the dual-circuit configuration is useful for I/Q, antenna, or redundant receiver paths that require coordinated gain control. Place the VGA where the signal level is predictable but variable, allowing downstream converters and data-recovery circuits to operate within a narrower input range. The linear-in-dB control law also makes calibration more intuitive when gain is represented as a logarithmic system parameter. Design the control input as a low-noise analog node, maintain symmetry between channels where phase matching matters, and verify gain accuracy and output compliance using the manufacturer’s test conditions.

🔧

Precision Instrumentation Amplification

The AD604ARZ is appropriate for wideband instrumentation requiring adjustable gain or attenuation rather than a fixed-gain amplifier. Its dual-channel structure supports two measurement paths with independent control, and its 40 MHz bandwidth provides headroom for fast sensor signals and laboratory waveforms. The device can be placed before a downstream buffer or converter when the source amplitude requires programmable range compression. Because instrumentation accuracy is influenced by the gain-control reference, grounding, and power supply, use a stable control source and decouple the 5 V rail close to the device. The linear-in-dB response simplifies control calibration, but absolute gain accuracy must be established using the manufacturer’s gain-control and frequency conditions rather than inferred from bandwidth alone.

🏭

Industrial Signal Conditioning

The AD604ARZ can serve as a programmable analog conditioning element in industrial systems that combine wideband sensing with changing signal amplitude. The 40 MHz bandwidth and dual-channel organization allow the device to handle two related sensor or test channels, while linear-in-dB gain control supports readable attenuation setpoints across a broad operating range. In a factory data-acquisition path, the VGA can control the level presented to a downstream converter, reducing the likelihood that unusually large or small input signals occupy the converter’s useful range. Keep control circuitry and analog traces separated from sensitive inputs, provide a low-impedance gain-control drive, and follow the manufacturer’s decoupling recommendations. Industrial temperature requirements should be checked against the stated -40°C to +85°C operating range and the complete system thermal profile.

🔧

Test and Measurement Front End

The AD604ARZ is well suited to bench and automated test systems that must present changing source amplitudes to downstream measurement equipment. Its two channels allow simultaneous treatment of a reference and measurement path, and the 40 MHz bandwidth supports fast pulse, waveform, and communication measurements. A controller or DAC can command attenuation to keep the measured signal within the optimal range of a downstream scope, analyzer, or ADC. The logarithmic control relationship simplifies automated range selection and test-sequence setup. For best performance, terminate the gain-control input as specified by the manufacturer, place supply and decoupling networks close to the device, and maintain short analog paths with a continuous ground reference. Check the exact input range, gain span, and settling behavior before defining the automation limits.

تجویز کردہ پروڈکٹس کا خلاصہ

AD604ARZ-RL Tape-and-reel order form of the same AD604ARZ device استعمال ہوتا ہے: Ultrasound Imaging Receiver, Medical Diagnostic Signal Chain, Communications Receiver Front End, Precision Instrumentation Amplification, Industrial Signal Conditioning, Test and Measurement Front End AD604AR Analog Devices استعمال ہوتا ہے: Ultrasound Imaging Receiver, Medical Diagnostic Signal Chain, Communications Receiver Front End, Precision Instrumentation Amplification, Industrial Signal Conditioning, Test and Measurement Front End
What is the AD604ARZ?
The AD604ARZ is a dual-channel variable gain amplifier with a 40 MHz bandwidth and a linear-in-dB gain-control response. Analog Devices describes the AD604 family as an ultralow-noise, highly accurate VGA intended primarily for ultrasound systems, although its wide bandwidth also supports other time-based variable-gain signal chains. The AD604ARZ is packaged in a 24-lead SOIC.
Where can I download the AD604ARZ datasheet PDF?
The official AD604ARZ documentation is available through the Analog Devices AD604 product page at https://www.analog.com/en/products/ad604.html. The manufacturer page provides the AD604 data sheet, product selection information, and supporting product resources. Use the ordering information and pin-description table in that documentation when assigning PCB nets and confirming the 24-lead SOIC footprint.
Where can I find the AD604ARZ pinout?
The AD604ARZ pinout is documented in the manufacturer’s AD604 data sheet linked from the official product page. The device uses a 24-lead SOIC package, and the pin-description table should be used to identify each amplifier input, output, gain-control terminal, power pin, and ground connection. Do not infer terminal assignments from package position alone.
What are the key specifications of AD604ARZ that engineers should know?
The principal AD604ARZ specifications are two independently usable amplifier circuits, a 40 MHz bandwidth, linear-in-dB gain control, a 5 V supply, and a -40°C to +85°C operating range. The device is offered in a 24-lead SOIC package. These characteristics place it in the variable gain amplifier category and make it particularly relevant to wideband ultrasound and instrumentation front ends.
Is the AD604ARZ suitable for ultrasound receivers?
Yes, the AD604ARZ is suitable for ultrasound receivers because the AD604 family is optimized for time-based variable gain control in ultrasound applications. Its dual-channel architecture supports two receiver channels, while the 40 MHz bandwidth accommodates wideband echo signals. The linear-in-dB control characteristic also simplifies the relationship between a control voltage and the requested gain change.
What is the difference between AD604ARZ and AD604ARZ-RL?
AD604ARZ-RL is a tape-and-reel order code for the AD604ARZ rather than a different electrical amplifier design. The device designation remains the AD604ARZ family, while the -RL suffix identifies the shipping format. Because order-code packaging does not create a distinct drop-in electrical alternative, the original AD604ARZ and its reel form should be treated as the same functional product.
AD604ARZ vs AD604AR - which is better for a new design?
AD604ARZ is the 24-lead SOIC order code identified as the production device in the AD604 product information. AD604AR appears in comparison listings, but the verified material does not establish that it uses the identical package or pin arrangement. For a new design, use AD604ARZ and confirm the required footprint against its manufacturer pin-description table before considering AD604AR.
When should I choose AD604ARZ over another variable gain amplifier?
Choose the AD604ARZ when the design requires two channels of wideband variable gain, a 40 MHz signal path, linear-in-dB control, and a 24-lead SOIC implementation. It is especially relevant to ultrasound receivers and instrumentation requiring time-based gain adjustment. Select another amplifier when its gain-control range, noise performance, supply voltage, or package offers a closer fit to the system requirements.
What can replace the AD604ARZ?
No independently verified cross-manufacturer drop-in replacement for the AD604ARZ was established with a confirmed identical footprint and pin assignment. AD604ARZ-RL is the same electrical device in tape-and-reel packaging, while AD604AR and other family references require package and pin verification. Do not treat a functional VGA as a drop-in replacement unless its complete data sheet confirms mechanical and electrical compatibility.
Is the AD604ARZ the same as AD604ARZ-RL?
The AD604ARZ and AD604ARZ-RL have the same core AD604ARZ amplifier designation, with -RL identifying the tape-and-reel shipping format. They should not be presented as different electrical alternatives. For procurement, use the exact order code required by the assembly process and confirm reel orientation, quantity, and packing documentation before release to manufacturing.
Where can I buy AD604ARZ and request current lead time?
Use the Request a Quote form on this page to request AD604ARZ availability, current lead time, and order quantities from XAIPART. The product is listed in production by Analog Devices, but manufacturing schedule and inventory can change. Provide the required quantity, reel or tray preference, and target ship date so the request can be evaluated as a complete sourcing inquiry.
How much does the AD604ARZ cost?
Current AD604ARZ pricing is not published as a fixed figure on this page because commercial terms depend on quantity, order code, and supply status. Submit the required quantity and packaging preference through the Request a Quote form on this page. That request provides the appropriate commercial path for current pricing and lead-time confirmation without presenting a stale list figure.
Is the AD604ARZ in stock?
Current AD604ARZ inventory is not represented as a guaranteed stock quantity on this page. Use the Request a Quote form on this page to ask for an availability check and current lead time, including the desired quantity and AD604ARZ order code. This approach distinguishes a confirmed allocation for your build from a general distributor inventory statement that may change without notice.
How should the AD604ARZ gain-control network be designed?
Drive each gain-control input from a source that stays within the manufacturer’s permitted control-voltage range while keeping noise away from the sensitive analog path. Route the control signal away from input and output traces, and use a quiet reference or DAC output with suitable impedance and decoupling. The exact control-voltage range and recommended resistor values must be taken from the AD604 manufacturer data sheet.
What compliance documents are available for the AD604ARZ?
The product catalog information identifies the AD604ARZ as EU RoHS compliant and REACH compliant. Its conflict-minerals status is recorded as DRC conflict-free undeterminable, so it should not be represented as a definitive declaration of all required reporting obligations. Automotive qualification and detailed material declarations should be confirmed with Analog Devices for the exact order code.

کے لیے انجینئرنگ ریفرنس ڈیٹا AD604ARZ — موازنہ، ڈیزائن رہنمائی، اور تعمیل کی معلومات۔

انتخاب کی گائیڈ

Choose the AD604ARZ for a dual-channel, wideband signal path that needs electronically controlled attenuation, particularly when the application resembles an ultrasound time-gain-control system. Its 40 MHz bandwidth, linear-in-dB response, two amplifier circuits, 5 V operation, and 24-lead SOIC package form the primary selection criteria. Choose AD604ARZ-RL when reel packaging is required for high-volume assembly rather than a different electrical specification. Consider AD604AR only after confirming that its package and pinout match the intended PCB. For a third-party replacement, require evidence of an identical footprint, compatible pin functions, equivalent gain-control voltage range, and compatible bandwidth, noise, supply, and output specifications. Do not select a functional VGA solely by its gain range because gain-control polarity, calibration method, and package geometry can prevent drop-in operation.

متبادلات کے ساتھ موازنہ

پیرامیٹر یہ پروڈکٹ
Product Type Dual-channel variable gain amplifier
Brand Analog Devices
Package 24-lead SOIC
Amplifier Circuits 2 circuits
Bandwidth 40 MHz
Gain Control Linear in dB
Supply Voltage 5 V
Operating Temperature -40°C to +85°C
RoHS Status Compliant
REACH Status Compliant

اہم امتیازی خصوصیات

  • Dual-channel variable gain amplifier in one package (بمقابلہAD604AR)
  • Linear-in-decibel gain-control behavior (بمقابلہAD604AR)
  • Production status in the 24-lead SOIC format (بمقابلہAD604ARZ-RL)

ڈیزائن نوٹس

Keep the two amplifier channels physically separated far enough to minimize shared coupling through supply and ground paths. Route each input directly to its corresponding device pin without long parallel runs, and place the gain-control traces away from high-level output and clock-like switching nodes. Use a continuous ground reference beneath the analog section because gain-control and output accuracy can be affected when return currents encounter common-impedance paths.

Follow the manufacturer’s recommended supply-bypass configuration and place the decoupling network close to the 5 V and ground pins. The bypass capacitor must provide a low-inductive return path rather than relying on a distant bulk capacitor. Check the power-consumption requirement under both channels at maximum activity, because operating two amplifier circuits can increase total supply demand relative to a single-channel implementation.

Treat each gain-control input as a sensitive analog-control node. Drive it from a low-noise source with the output impedance required by the AD604 data sheet, and isolate the control trace from clocks, converters, and relay drivers. Include the gain-setting network where it can be trimmed or calibrated, and verify settling time at the highest gain-control bandwidth used by the system.

Do not assume that AD604ARZ-RL is a different electrical amplifier; the -RL suffix identifies the reel shipping option. Likewise, do not substitute AD604AR or a third-party VGA without checking the complete footprint, pin names, pin functions, supply requirements, and gain-control transfer function. A functional match in bandwidth or noise is not enough to establish drop-in compatibility for an existing PCB.

تعمیل کی معلومات

RoHS
Compliant
REACH
Compliant
AEC-Q100
Unknown
لیڈ فری
Unknown
ہیلوجن فری
Unknown
کنفلیکٹ منرلز
Unknown

Catalog information identifies EU RoHS and REACH compliance. The conflict-minerals field is recorded as DRC conflict-free undeterminable and is therefore treated as unknown. Lead-free, halogen-free, and AEC-Q100 status were not established.

ڈیٹا کی تصدیق کی تاریخ: 2026-11-18 — ڈیٹا XAIPART کی کمپوننٹ انجینئرنگ ٹیم کے ذریعے تصدیق شدہ اور ترتیب شدہ

متعلقہ تلاشیں

AD604ARZ datasheet AD604ARZ datasheet pdf AD604ARZ pinout AD604ARZ footprint AD604ARZ equivalent AD604ARZ replacement AD604ARZ cross reference AD604ARZ vs AD604AR AD604ARZ ultrasound amplifier AD604ARZ price AD604ARZ stock Analog Devices AD604ARZ AD604 40MHz VGA AD604ARZ 24-SOIC AD604ARZ application circuit

متعلقہ اجزاء اور اصطلاحات

Analog Devices AD604ARZ AD604 AD604AR AD604ARZ-RL variable gain amplifier VGA ultralow noise amplifier linear-in-dB gain control time-based variable gain control ultrasound imaging medical diagnostic equipment communications receiver instrumentation amplifier test and measurement 5 V power supply 40 MHz bandwidth -40°C to +85°C 24-lead SOIC SOIC package surface-mount package RoHS REACH analog signal conditioning gain-control input
فوری کوٹ RFQ
مکمل تفصیلات بھریں — ہماری سیلز ٹیم 24 گھنٹوں میں جواب دے گی
پارٹ نمبر مینوفیکچرر پیکج QTY ہدف قیمت کل رقم
✓
کوٹ جمع ہو گیا!

ہم 24 گھنٹوں کے اندر آپ کے ای میل کا جواب دیں گے

1
RFQ جمع ہو گیا
2
کوٹ موصول ہو گیا
3
آرڈر دے دیا گیا
4
ادائیگی
5
بھیج دیا گیا
6
ڈیلیور شدہ