CD4051BEE4 - 20V 8:1 Analog Multiplexer | Texas Instruments
MPN: CD4051BEE4 ✗ اختتامِ زندگیCD4051BEE4 جائزہ
An analog multiplexer is a semiconductor switch that selects one signal path from multiple candidates. The CD4051B belongs to the broader CD4000 CMOS logic family, combining digital address-control logic with bidirectional analog switching. The multiplexer's select and inhibit signals can operate from a supply different from the analog-signal range, providing logic-level conversion when the control supply and signal supply are selected appropriately.
Key characteristics include one 8:1 channel, 240 Ω nominal on-resistance, and 125 Ω typical on-resistance at a 15 V supply according to the component technical summary. The device supports analog signals up to the stated 20 V operating limit. Its PDIP package also supports a -55 °C to 125 °C temperature range, making it suitable for industrial, instrumentation, communications, and environmental-testing equipment that requires a through-hole component.
The CD405xB architecture supports operation as either an analog multiplexer or an analog demultiplexer. Three select inputs define one of eight channel states, while the inhibit input provides a way to disable the selected path. Logic-level conversion allows compatible control from another supply domain, but the relationship between input, output, inhibit, and supply voltages must be checked against the manufacturer datasheet before implementation.
Typical uses include sensor-channel selection, instrumentation signal routing, automated test equipment, data-acquisition systems, control-signal multiplexing, and communications equipment. In each case, the device reduces the number of analog front-end connections by allowing several physical channels to share one downstream converter, amplifier, or control block.
PCB layout should keep connected analog traces short and away from high-current switching paths. The through-hole PDIP package simplifies prototype assembly, while the broad temperature range supports demanding industrial environments. Verify supply sequencing, control logic levels, maximum signal voltage, and switching transients before finalizing the design.
This page combines the manufacturer product information, distributor listing details, package and lifecycle facts, pin mapping, drop-in replacement analysis, and practical selection guidance to support faster engineering decisions for CD4051BEE4 sourcing and circuit implementation.
کے لیے ڈراپ اِن متبادل CD4051BEE4 — یکساں پیکیج، پن سے پن مطابقت پذیر۔ مختلف پیکیج والے پرزے جن کے لیے PCB دوبارہ کام درکار ہو، شامل نہیں ہیں۔
اس سیریز میں مختلف ورژن
اسی سیریز کے ماڈلز جو ڈراپ اِن مطابقت رکھتے ہیں CD4051BEE4 (یکساں فارم فیکٹر اور فٹ پرنٹ) — میں مختلف Package, Mounting Type, Inhibit Control, Number of Channels, Off-State Leakage.
CD4051BE
✅ ڈراپ-اِنقیمت کے لیے رابطہ کریں
ڈیٹا شیٹ دیکھیں →CD4051BCN
✅ ڈراپ-اِنقیمت کے لیے رابطہ کریں
ڈیٹا شیٹ دیکھیں →CD4051BNS
✅ ڈراپ-اِن📋 حوالہ جاتی متبادل (کیٹلاگ میں نہیں)
CD4051BPW
✅ ڈراپ-اِنقیمت کے لیے رابطہ کریں
ڈیٹا شیٹ دیکھیں →MC74HC4051ANG
✅ ڈراپ-اِن📋 حوالہ جاتی متبادل (کیٹلاگ میں نہیں)
CD4051BEE4 زیادہ سے زیادہ ریٹنگز اور برقی خصوصیات
| Multiplexer Configuration | 8:1 |
| Number of Channels | 1 circuit |
| Supply Voltage Range | 3 V to 20 V |
| Maximum Supply Voltage | 20 V |
| Nominal On-Resistance | 240 Ω |
| Typical On-Resistance | 125 Ω at VDD = 15 V |
| آپریٹنگ درجہ حرارت رینج | -55 °C to 125 °C |
| Package Type | PDIP-16 |
| Terminal Count | 16 terminals |
| ماؤنٹنگ ٹائپ | Through-hole |
| Logic-Level Conversion | Supported |
| Multiplexing Function | Analog multiplexer or demultiplexer |
| Select Input Count | 3 binary select inputs |
| Inhibit Control | Dedicated inhibit input |
| Technology | CMOS |
| RoHS اسٹیٹس | Compliant |
| AEC-Q100 Qualification | Not applicable |
| Production Status | No longer in production |
CD4051BEE4 پن کنفیگریشن
| پن 1 | I/O 0 — Analog input/output channel 0 |
| پن 2 | I/O 2 — Analog input/output channel 2 |
| پن 3 | I/O 4 — Analog input/output channel 4 |
| پن 4 | I/O 6 — Analog input/output channel 6 |
| پن 5 | I/O 3 — Analog input/output channel 3 |
| پن 6 | I/O 1 — Analog input/output channel 1 |
| پن 7 | VSS — Negative supply or ground reference |
| پن 8 | INH — Inhibit input used to disable the selected channel |
| پن 9 | A — Binary select input A |
| پن 10 | B — Binary select input B |
| پن 11 | C — Binary select input C |
| پن 12 | D — Inhibit or fourth select input according to operating configuration |
| پن 13 | VDD — Positive supply |
| پن 14 | I/O 7 — Analog input/output channel 7 |
| پن 15 | I/O 5 — Analog input/output channel 5 |
| پن 16 | NC — Not connected |
عام استعمالات
CD4051BEE4 کے لیے موزوں ہے 6 ایپلیکیشنs: Industrial Sensor Channel Selection, Automated Test Equipment Signal Routing, Data Acquisition Front End, Control Signal Multiplexing, Communications Signal Routing, Legacy Instrumentation Signal Switching.
Industrial Sensor Channel Selection
The CD4051BEE4 is suitable for selecting among multiple analog sensor outputs when the system must support a broad -55 °C to 125 °C ambient range. Its 8:1 configuration connects one selected sensor path to the common terminal while three binary select inputs identify the channel. The 240 Ω nominal on-resistance adds series resistance that must be included in divider and amplifier-input calculations. For high-impedance sensors, use a suitable input buffer after the mux and verify that sensor leakage and temperature drift do not corrupt the selected measurement.
تجویز کردہ
Automated Test Equipment Signal Routing
In automated test equipment, the CD4051BEE4 can route one of eight test points to a common measurement amplifier, reducing the number of analog input connections required by the controller. Its 16-pin PDIP package is convenient for through-hole test fixtures, and the specified -55 °C to 125 °C range supports industrial environments. The design must account for 240 Ω nominal insertion resistance, possible switch transients, and the voltage presented by every routed test point. Keep fixture traces short and add protection if any channel can exceed the device signal limits.
تجویز کردہ
Data Acquisition Front End
The CD4051BEE4 can share a single data-acquisition converter among eight conditioned analog inputs. Three select lines establish the channel address, while the inhibit input allows the acquisition system to isolate the mux during configuration changes. This arrangement reduces converter count and PCB routing complexity in legacy measurement systems. Designers should budget the mux resistance against the input impedance of the ADC front end, ensure the selected signal stays within the allowable range, and use a separate precision reference and grounding strategy for best conversion performance.
تجویز کردہ
Control Signal Multiplexing
The CD4051BEE4 can select one of eight control signals and route it to a shared actuator or driver interface. Logic-level conversion allows the select and inhibit controls to be referenced to a separate control supply when the recommended voltage relationships are respected. The approach is useful in legacy control cabinets where reducing driver count is important, but the 240 Ω nominal on-resistance may be significant for high-current commands. Use the mux for voltage-level or command signals rather than power-stage current, and preserve separate protection paths for loads.
تجویز کردہ
Communications Signal Routing
The CD4051BEE4 can route low-frequency or low-amplitude communication paths among eight channels in legacy communications and interface equipment. Its 20 V supply architecture supports broader signal-range flexibility than a low-voltage logic mux, while the -55 °C to 125 °C specification suits industrial environments. The 240 Ω nominal on-resistance can attenuate high-impedance sources and adds insertion loss, so the complete source and receiver impedance must be calculated. Keep routing away from clocks, switching regulators, and high-current return paths to minimize crosstalk.
تجویز کردہ
Legacy Instrumentation Signal Switching
The CD4051BEE4 offers a practical way to route multiple measurement sources in legacy instrumentation while preserving a -55 °C to 125 °C operating range. The common analog terminal can feed a precision amplifier, comparator, or meter input, and the three select inputs may be driven by a counter or microcontroller. Because the device is no longer in production, engineers should qualify the exact source, packaging condition, and traceable supply before using it in new production. For redesigns with faster switching or lower resistance requirements, compare the listed alternatives against the complete signal chain.
تجویز کردہ
تجویز کردہ پروڈکٹس کا خلاصہ
کے لیے انجینئرنگ ریفرنس ڈیٹا CD4051BEE4 — موازنہ، ڈیزائن رہنمائی، اور تعمیل کی معلومات۔
انتخاب کی گائیڈ
متبادلات کے ساتھ موازنہ
| پیرامیٹر | یہ پروڈکٹ | CD4051BE | CD4051BCN | CD4051BNS | CD4051BPW | MC74HC4051ANG |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | onsemi |
| Package | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP |
| Multiplexer Configuration | 8:1 | 8:1 | 8:1 | 8:1 | 8:1 | 8:1 |
اہم امتیازی خصوصیات
- Broad specified temperature range (بمقابلہMC74HC4051ANG)
- Higher-voltage signal-routing architecture (بمقابلہMC74HC4051ANG)
- Original CD4051B footprint continuity (بمقابلہCD4051BPW)
- Defined legacy on-resistance class (بمقابلہCD4051BE)
ڈیزائن نوٹس
Include the CD4051BEE4 on-resistance in the complete source-to-receiver transfer function. A nominal 240 Ω path resistance can materially attenuate a high-impedance sensor or create an error when the downstream amplifier has bias current. Use a low-input-bias amplifier or buffer after the mux, verify the 125 Ω typical behavior at 15 V against the operating condition, and avoid relying on nominal resistance for precision divider calculations.
Place the multiplexed analog path away from clocks, relay coils, switching-regulator nodes, and high-current return paths. Keep the common terminal and eight analog traces short, use a continuous ground reference, and avoid sharing narrow copper paths between sensitive channels. In a PDIP design, reserve adequate spacing around pin 12 so its inhibit or configuration function remains accessible and is not confused with the binary select inputs.
Do not assume that the inhibit pin may be left unconnected or driven beyond the permitted control range. Review the manufacturer pin description and logic-level-conversion conditions before defining pin 12. Also verify that every analog terminal remains within the allowable signal and supply limits, particularly during startup, fault injection, or input overvoltage events; a multiplexer cannot protect downstream circuitry by itself.
Decouple VDD close to the supply pin with the capacitance recommended by the manufacturer, and provide a low-impedance ground reference at VSS. Inspect transient behavior across all eight channels because switching can disturb sensitive downstream measurements. If the mux is powered from a shared rail, account for its supply current and switching disturbance in that rail's load budget rather than treating the device as a purely passive connection.
The specified -55 °C to 125 °C operating range does not remove the need for system-level thermal qualification. Estimate internal dissipation from the actual supply voltage, channel current, and duty cycle, then confirm that the PDIP construction, PCB airflow, and enclosure keep the device within its rated junction-temperature limit. For sustained high-current paths, split the load across multiple mux channels or use a lower-resistance alternative.
تعمیل کی معلومات
RoHS compliance is identified by component comparison records. REACH, lead-free, halogen-free, and conflict-minerals status were not confirmed. The part is not designated as an automotive-qualified AEC-Q100 product.