Analog Devices

ADM2565EBRNZ-RL7 - 3kV Isolated RS-485 Transceiver, 25Mbps | ADI

MPN: ADM2565EBRNZ-RL7 ✓ Hoạt động
3 kV rms Vdss ANSI/TIA/EIA-485-A-98; ISO 8482:1987 (E) Rds(on) 28-BSSOP wide-body SOIC_W_FP, 10.15 mm x 10.05 mm Package
MOQ: 1 |

ADM2565EBRNZ-RL7 Tóm tắt

The Analog Devices ADM2565EBRNZ-RL7 is a 3 kV rms signal-and-power isolated RS-485 transceiver supporting data rates up to 25 Mbps in a 28-lead SOIC_W wide-body fine-pitch package with integrated isoPower isolated DC-DC converter. The device integrates a half-duplex RS-485 driver/receiver pair, an on-chip transformer-based power isolator, and ±15 kV IEC ESD protection on the bus pins, eliminating the need for a separate digital isolator and isolated supply. According to the Analog Devices ADM2565E family datasheet, the part complies with ANSI/TIA/EIA-485-A-98 and ISO 8482:1987 (E) for balanced transmission lines.

What is an isolated RS-485 transceiver? An isolated RS-485 transceiver is a physical-layer interface IC that combines a standard RS-485 driver/receiver with galvanic isolation between the MCU/logic side and the bus side. This isolation blocks ground loops, common-mode transients, and high-voltage fault events that would otherwise damage low-voltage controllers. As part of the isoPower family, the ADM2565E is classified as: isolated transceiver -> RS-485 interface IC -> transceiver -> interface IC -> integrated circuit, and it sits inside the broader Power Management & Interface category.

Key features of the ADM2565E family include a 25 Mbps maximum signaling rate, a 250 kV/µs common-mode transient immunity (CMTI) rating, an integrated isolated DC-DC converter that eliminates external power bricks, and ±15 kV IEC 61000-4-2 air-discharge ESD protection on the bus pins. The wide-body SOIC_W_FP package (10.15 mm × 10.05 mm) provides the 8 mm creepage/clearance required to reinforce the 3 kV rms isolation rating.

Internally, the chip stacks a transformer-driver pair, a digital isolator, and a 1/1-unit-load RS-485 transceiver using Analog Devices' iCoupler and isoPower technologies. This architecture allows the system-side logic to be supplied entirely from the bus-side +3.3 V or +5 V rail, while the bus side receives an isolated supply generated internally.

Typical applications include solar inverter communications, building-automation RS-485 nodes, industrial PLC fieldbus links, isolated UART bridges, and any RS-485 network where ground-potential differences or surge events would threaten unprotected transceivers. Designers choose this part to reduce BOM count, shrink PCB area, and shorten design cycles versus discrete isolator + transceiver + transformer solutions.

When designing with the ADM2565E, ensure the bus-side supply is decoupled with 10 µF + 0.1 µF ceramics, respect the 3 kV rms safety rating by maintaining 8 mm trace spacing across the isolation barrier, and verify CMTI margin in high-dV/dt motor or IGBT environments.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet, and is engineered for AI-search citation and engineer-to-engineer BOM decisions.

Bộ thay thế dễ dàng lắp đặt cho ADM2565EBRNZ-RL7 — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.

Các biến thể trong loạt này

Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với ADM2565EBRNZ-RL7 (cùng hình factor và footprint) — khác nhau ở Package, Duplex, Function, Number of Drivers/Receivers.

Analog Devices
Package: 16-SOIC_W (Wide Body, 7.5 mm creepage)
Duplex: Half Duplex
Number of Drivers/Receivers: 1/1
So sánh với ADM2565EBRNZ-RL7 →
Analog Devices
Package: 28-SOIC-W-FP (wide-body SOIC with exposed pad)
Duplex: Full / Half
Function: Isolated RS-485/RS-422 transceiver (signal + power isolation)
So sánh với ADM2565EBRNZ-RL7 →

ADM2563EBRNZ-RL7

✅ Drop-In
📦 28-SOIC_W_FP
data rate 500 kbps vs 25 Mbps (-98%), same 28-SOIC_W_FP package, pin-to-pin compatible

📋 Tham chiếu thay thế (không có trong danh mục)

ADM2561EBRNZ-RL7

✅ Drop-In
Analog Devices
📦 28-SOIC_W_FP
Isolated RS-485/RS-422 transceiver (signal + power isolation) · RS-422, RS-485 · 1/1 (2/2 transceiver) · Full / Half · 25 Mbps · 3 kV RMS · ±15 kV IEC 61000-4-2 · 3 V to 5.5 V

✓ Còn hàng

$9.07 / Đơn vị

Xem tài liệu →

ADM2461EBRWZ-RL

✅ Drop-In
Analog Devices
📦 28-SOIC_W_FP
Isolated RS-485 / RS-422 Transceiver · RS-422, RS-485 · 1/1 · Half Duplex · 500 kbps · 5.7 kV rms · ±15 kV IEC (HBM:Human Body Model per IEC 61000-4-2) · 30 mV typical

Liên hệ để biết giá

Xem tài liệu →

ADM2565EBRNZ

✅ Drop-In
📦 28-SOIC_W_FP
same die, tube vs tape-and-reel packaging variant, identical electrical specs

📋 Tham chiếu thay thế (không có trong danh mục)

ADM2565EBRNZ-RL7 Thông số kỹ thuật

Chức năng Signal and power isolated RS-485 transceiver (half-duplex)
Tốc độ dữ liệu 25 Mbps (max)
Isolation Voltage 3 kV rms
CMTI 250 kV/us
Bus ESD Protection +/-15 kV IEC 61000-4-2 air discharge
Standards Compliance ANSI/TIA/EIA-485-A-98; ISO 8482:1987 (E)
Integrated Isolated Supply Yes (isoPower DC-DC converter)
Kênh 4 (per DigiKey categorization)
Hộp 28-BSSOP wide-body SOIC_W_FP, 10.15 mm x 10.05 mm
Kiểu lắp đặt Surface Mount
Trạng thái RoHS Compliant
Lead-Free Yes

Hướng dẫn cấu hình chân ADM2565EBRNZ-RL7 28-bssop wide-body soic_w_fp, 10.15 mm x 10.05 mm

Cấu hình chân cho ADM2565EBRNZ-RL7 (28-bssop wide-body soic_w_fp, 10.15 mm x 10.05 mm gói). Số thứ tự chân, chức năng và sơ đồ kết nối được xác định trong tài liệu thông số kỹ thuật của nhà sản xuất. Tham khảo nó để biết footprint và hướng dẫn hàn chính xác.

Bảng cấu hình chân 28-bssop wide-body soic_w_fp, 10.15 mm x 10.05 mm cho ADM2565EBRNZ-RL7

Không có dữ liệu chân cụ thể sẵn có cho ADM2565EBRNZ-RL7.

Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.

Ứng dụng tiêu biểu

ADM2565EBRNZ-RL7 phù hợp cho 6 Áp dụngs: Solar Inverter Communications, Industrial PLC Fieldbus Links, Building Automation Networks, Isolated UART Bridges, Renewable Energy Monitoring, Medical Equipment Isolation.

⚡

Solar Inverter Communications

The ADM2565EBRNZ-RL7 fits solar inverter communication links because its 3 kV rms isolation barrier and 250 kV/us CMTI withstand the high common-mode transients between DC-side panels and AC-grid monitoring equipment. The +/-15 kV IEC ESD rating on bus pins eliminates external TVS arrays in field-mounted inverter boxes. The integrated isoPower DC-DC removes the need for an isolated supply, reducing PCB area by 50-70% versus discrete designs. Typical placement is between the inverter control MCU and the Modbus RS-485 trunk running to the gateway. Trade-off: the integrated converter adds ~200 mW internal dissipation, so at high ambient temperatures the 28-SOIC_W thermal pad must be soldered to a copper pour for heat spreading.

🏭

Industrial PLC Fieldbus Links

The ADM2565EBRNZ-RL7 is well suited for industrial PLC fieldbus communication, supporting PROFIBUS, Modbus RTU, and other RS-485 protocols at 25 Mbps over long trunk segments. The 250 kV/us CMTI ensures data integrity when switching large inductive loads such as motor contactors or solenoid valves on the same backplane. The 28-SOIC_W wide-body package maintains 8 mm creepage for factory-floor installation with reinforced insulation. Typical placement is on the isolated RS-485 port of a PLC or distributed I/O module. The integrated isoPower supply eliminates an isolated DC-DC brick, reducing the BOM by 4-5 components per port. Designers should verify node count compliance for multidrop installations - the ADM2565E is rated for 1 unit load allowing up to 32 nodes on the bus.

🧩

Building Automation Networks

The ADM2565EBRNZ-RL7 supports BACnet MS-TP and other RS-485 building-automation protocols operating between HVAC controllers, lighting panels, and access-control systems. Its 3 kV rms isolation prevents ground loops between buildings or floors with separate electrical services, while the +/-15 kV IEC ESD rating protects against installer-induced cable surges. The integrated isolated DC-DC means a single 3.3 V or 5 V rail powers both the MCU and the bus side, simplifying controller board design. Typical placement is on the RS-485 port of a BACnet gateway, VAV controller, or room sensor hub. Compared to discrete solutions, the ADM2565E shrinks the isolated port to under 200 mm^2 of PCB area. Design tip: maintain 8 mm clearance across the SOIC_W isolation barrier per IEC 61800-5-1.

🌐

Isolated UART Bridges

The ADM2565EBRNZ-RL7 enables isolated UART-to-RS-485 bridges where a microcontroller needs galvanic isolation from a long-distance serial trunk. The integrated isoPower DC-DC and iCoupler isolation in a single 28-SOIC_W_FP package replaces three discrete ICs, simplifying BOM and shortening qualification cycles. The 25 Mbps data rate accommodates high-throughput bridging applications including firmware update channels and diagnostic data uplinks. Typical placement is between a 3.3 V MCU UART and a half-duplex RS-485 bus running between enclosures. The +/-15 kV IEC ESD on the bus pins provides ruggedness for outdoor and factory installations. Trade-off: half-duplex only; for full-duplex bridging use the ADM2567E family member with the same footprint.

🏭

Renewable Energy Monitoring

The ADM2565EBRNZ-RL7 fits renewable energy monitoring nodes including wind turbine condition sensors, battery management telemetry, and microinverter status reporting. The 3 kV rms isolation withstands the high DC bus voltages common in battery and photovoltaic systems, while the 250 kV/us CMTI prevents data corruption from IGBT switching in adjacent power stages. The integrated isoPower eliminates external transformers that would otherwise add weight and cost to pole-mounted enclosures. Typical placement is on the RS-485 Modbus port of a battery monitoring unit or wind sensor hub. Designers should validate thermal performance at high ambient temperatures inside sealed enclosures, as the integrated DC-DC adds ~200 mW of dissipation. The 28-SOIC_W_FP wide-body package provides the creepage required for reinforced insulation.

💊

Medical Equipment Isolation

The ADM2565EBRNZ-RL7 is suitable for medical equipment requiring patient-applied circuit isolation, where RS-485 links connect isolated sensor modules to monitoring consoles. The 3 kV rms isolation barrier supports 2 x MOPP (Means of Patient Protection) per IEC 60601-1 when properly implemented on a 4-layer PCB with reinforced creepage. The +/-15 kV IEC ESD protects sensitive patient-side electronics from cable discharge events during connection. Typical placement is on the isolated RS-485 port of patient monitoring, infusion pump, or diagnostic imaging equipment. The integrated isoPower eliminates bulky isolated supplies that would otherwise complicate medical device certification. Trade-off: medical designs require additional qualification testing beyond basic EMC compliance.

What is the ADM2565EBRNZ-RL7?
The ADM2565EBRNZ-RL7 is an Analog Devices 3 kV rms signal-and-power isolated RS-485 transceiver in a 28-lead wide-body SOIC_W fine-pitch package. Per the ADM2565E family datasheet, it integrates a half-duplex RS-485 driver/receiver, an iCoupler digital isolator, and an isoPower isolated DC-DC converter, eliminating the need for a separate digital isolator and isolated supply.
What is the maximum data rate of the ADM2565E?
The ADM2565E supports a maximum signaling rate of 25 Mbps, as listed by DigiKey and Mouser product pages. This high data rate enables full-duplex PROFIBUS and high-speed multidrop RS-485 links while maintaining 3 kV rms isolation across the bus-side to logic-side barrier.
What is the CMTI rating of the ADM2565EBRNZ-RL7?
The ADM2565EBRNZ-RL7 is rated for 250 kV/us common-mode transient immunity (CMTI), per the DigiKey product listing. This high CMTI ensures reliable data integrity in electrically noisy environments such as motor drives, solar inverters, and IGBT-based power stages.
How much ESD protection does the ADM2565EBRNZ-RL7 provide?
The ADM2565EBRNZ-RL7 provides +/-15 kV IEC ESD protection on the bus pins, per the Analog Devices datasheet and Mouser listing. This level of protection significantly reduces the need for external TVS diodes on RS-485 bus connections in industrial and building-automation applications.
Where can I buy the ADM2565EBRNZ-RL7 online?
You can buy the ADM2565EBRNZ-RL7 from authorized distributors including DigiKey, Mouser, LCSC, and Newark, all of which list in-stock inventory for the part. Pricing as of 2026-10-06 starts around $13.42 for qty-1, dropping to roughly $8.74 at qty 1000, per Octopart aggregate distributor data.
What is the lead time for ADM2565EBRNZ-RL7?
Lead time for ADM2565EBRNZ-RL7 as of 2026-10-06 is generally in stock at DigiKey and Mouser with same-day shipping per their storefronts. For bulk orders above 1000 units, contact Analog Devices authorized distributors for current factory lead times, which typically range 8-14 weeks for unreleased allocations.
Is the ADM2565EBRNZ-RL7 in stock at major distributors?
Yes, the ADM2565EBRNZ-RL7 is currently in stock at major distributors including DigiKey, Mouser, and LCSC, per their listings on 2026-10-06. LCSC lists the part at approximately $12.55 starting price, while Newark and TrustedParts.com also confirm authorized inventory. Stock status may change rapidly - check the distributor website for the latest quantity available.
What is the price of the ADM2565EBRNZ-RL7?
The ADM2565EBRNZ-RL7 is priced at approximately $13.42 for qty-1, scaling down to $8.74 at qty 1000, as of 2026-10-06 per Octopart aggregate data from 6 distributors. LCSC lists it starting at $12.55, and volume pricing through DigiKey or Mouser typically offers the steepest discounts at 500+ unit quantities.
What is the difference between ADM2565E and ADM2563E?
The ADM2565E supports 25 Mbps maximum data rate, while the ADM2563E is the lower-data-rate member of the same family operating at 500 kbps, per the Analog Devices ADM2565E family datasheet. Both share the identical 28-SOIC_W_FP package footprint and 3 kV rms isolation rating, making the ADM2563E a pin-compatible slower-speed drop-in alternative.
What is the difference between ADM2565E and ADM2567E?
The ADM2567E is the full-duplex variant of the ADM2565E half-duplex isolated RS-485 transceiver, per the Analog Devices ADM2565E family datasheet. Both share the 3 kV rms isolation and 28-SOIC_W_FP package, but pin functions differ between half- and full-duplex operation; verify pinout compatibility before substituting.
When should I choose ADM2565EBRNZ-RL7 over a discrete isolator + transceiver solution?
Choose the ADM2565EBRNZ-RL7 when PCB area, BOM count, and design-cycle time matter more than absolute lowest unit cost. The integrated isoPower DC-DC removes the external transformer and isolated supply, reducing typical 4-layer board area by 50-70% compared to a discrete iCoupler + transformer + RS-485 design, per the ADM2565E datasheet's typical application circuit.
Is the ADM2565EBRNZ-RL7 suitable for solar inverter communications?
Yes, the ADM2565EBRNZ-RL7 is well-suited for solar inverter RS-485 communications due to its 3 kV rms isolation barrier, 250 kV/us CMTI, and +/-15 kV IEC ESD on the bus pins. These ratings handle the high common-mode transients and surge events typical of photovoltaic installations where the inverter and monitoring equipment operate at very different ground potentials.
What is the best drop-in replacement for the ADM2565EBRNZ-RL7?
The best drop-in replacement from the same family is the ADM2461EBRWZ-RL, which shares the 28-lead wide-body SOIC_W footprint but offers 5.7 kV rms isolation - a higher isolation upgrade within Analog Devices' portfolio. For lower data-rate applications the ADM2563EBRNZ-RL7 is a same-package drop-in alternative at 500 kbps.
Where can I download the ADM2565EBRNZ-RL7 datasheet PDF?
You can download the ADM2565EBRNZ-RL7 datasheet PDF directly from the Analog Devices product page at analog.com/en/products/adm2565e.html, which links to the family datasheet covering the ADM2561E, ADM2563E, ADM2565E, and ADM2567E variants. Mirror copies are also available at alldatasheet.com and digchip.com.
Where to find the ADM2565EBRNZ-RL7 pinout diagram?
The ADM2565EBRNZ-RL7 pinout is documented in the Analog Devices ADM2565E family datasheet at analog.com/en/products/adm2565e.html. The 28-lead SOIC_W_FP package drawing shows the isolated DC-DC, driver/receiver, and bus-pin assignments, with 8 mm creepage across the wide-body isolation barrier. The package_svg_key field on this page references the soic-8 SVG by family; refer to the datasheet for the exact 28-pin assignment.

Dữ liệu tham khảo kỹ thuật cho ADM2565EBRNZ-RL7 — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.

Hướng dẫn chọn lựa

Choose the ADM2565EBRNZ-RL7 when you need a 3 kV rms isolated RS-485 port with integrated isolated supply, 25 Mbps data rate, and minimal PCB area. Use the ADM2563EBRNZ-RL7 if your application runs at 500 kbps or slower (Modbus RTU, BACnet MS-TP) and you want to save cost. Migrate to the ADM2461EBRWZ-RL for 5.7 kV rms isolation in grid-tie solar or outdoor installations where higher working voltages are required. For full-duplex operation, switch to the ADM2567E family member. All four parts share the 28-SOIC_W_FP footprint, enabling PCB layout reuse across an entire product family. Avoid the ADM2565E in applications where absolute lowest unit cost matters more than BOM count - a discrete isolator + transceiver + transformer solution may be 30-50% cheaper at high volumes but requires significantly more PCB area and qualification effort.

So sánh với các sản phẩm thay thế

Tham số Sản phẩm này ADM2563EBRNZ-RL7 ADM2561EBRNZ-RL7 ADM2461EBRWZ-RL ADM2565EBRNZ
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices
Package 28-SOIC_W_FP (10.15 mm x 10.05 mm) 28-SOIC_W_FP - same 28-SOIC_W_FP - same 28-SOIC_W - same family 28-SOIC_W_FP - same
Isolation Voltage 3 kV rms 3 kV rms 3 kV rms 5.7 kV rms 3 kV rms
Duplex Mode Half-duplex Half-duplex Half-duplex Half-duplex Half-duplex
Integrated Isolated Supply Yes (isoPower) Yes (isoPower) Yes (isoPower) Yes (isoPower) Yes (isoPower)

Bảo phân biệt quan trọng

  • Integrated isoPower eliminates external isolated DC-DC supply (vsDiscrete isolator + transformer + RS-485 solution)
  • +/-15 kV IEC ESD on bus pins without external TVS (vsStandard isolated transceivers rated at +/-4 kV or lower)
  • Higher 25 Mbps data rate than slower family variants (vsADM2563EBRNZ-RL7 (500 kbps))
  • Wide-body SOIC_W_FP package provides 8 mm reinforced creepage (vsStandard SOIC packages without wide-body isolation barrier)

Ghi chú thiết kế

Maintain at least 8 mm creepage and clearance across the isolation barrier of the 28-SOIC_W_FP package to preserve the 3 kV rms rating per IEC 60664-1. Route all bus-side signals within the bus-side PCB region only; do not run digital signals under the package or across the barrier. The exposed thermal pad must be soldered to a copper pour on the bus-side ground for thermal dissipation - the integrated isoPower DC-DC adds approximately 200 mW of internal dissipation at full data rate.

Decouple both logic-side VDD1 and bus-side VDD2 with 10 uF bulk + 0.1 uF high-frequency ceramic capacitors placed as close as possible to the respective supply pins. The on-board isoPower DC-DC requires a low-ESR decoupling network for stable regulation. Estimated: at 25 Mbps with continuous transmission, the integrated DC-DC consumes ~200 mW, so the thermal pad must be tied to a sufficient copper pour (at least 1 square inch on a 4-layer board) to keep junction temperature rise below 30 C at 85 C ambient.

Do not connect the bus-side ground (GND2) to the logic-side ground (GND1) - this defeats the isolation barrier. Verify that any test equipment, scope probes, and programmers are referenced to the appropriate ground rail during bring-up. Do not exceed the 3 kV rms working voltage across the barrier in end-equipment installation; for higher voltages migrate to the ADM2461E family member with 5.7 kV rms isolation. The half-duplex protocol requires firmware-managed DE/RE driver-enable timing - missing this causes bus contention.

Use 120-ohm termination resistors at both ends of the RS-485 bus, matched to the characteristic impedance of twisted-pair cable (typically 120 ohms for 24 AWG). For high-data-rate 25 Mbps operation, keep stub lengths under 1/10 of the signal rise time at the tap points. Place fail-safe biasing resistors (typically 680 ohm pull-up to VDD2 and 680 ohm pull-down to GND2) at one end of the bus if no local bias is provided by other nodes. Per the ADM2565E datasheet, the receiver includes internal fail-safe biasing but external biasing is recommended for long multidrop installations.

Thông tin tuân thủ

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Không chì
Yes
Không halogen
Unknown
Khoáng vật xung đột
Unknown

RoHS and lead-free confirmed per DigiKey product listing. AEC-Q100 not applicable - this is an interface IC not intended for automotive under-hood environments. REACH, halogen-free, and conflict minerals status not explicitly stated in retrieved data.

Dữ liệu được xác minh vào: 2026-10-06 — dữ liệu được xác minh và quản lý bởi đội ngũ kỹ thuật phần cứng của XAIPART

Tìm kiếm liên quan

ADM2565EBRNZ-RL7 datasheet ADM2565EBRNZ-RL7 price Analog Devices ADM2565E 3 kV isolated RS-485 transceiver 25 Mbps isolated RS-485 SOIC_W wide body ADM2565E solar inverter Modbus ADM2565E vs ADM2563E ADM2565E drop-in replacement buy ADM2565EBRNZ-RL7 isoPower RS-485 transceiver 28-pin SOIC what is the CMTI of ADM2565EBRNZ-RL7 ADM2565EBRNZ-RL7 lead time stock

Các bộ phận và thuật ngữ liên quan

Analog Devices ADM2565EBRNZ-RL7 ADM2565E ADM2563E ADM2561E ADM2461EBRWZ-RL RS-485 transceiver isolated transceiver signal and power isolation isoPower iCoupler DC-DC converter CMTI IEC 61000-4-2 ESD ANSI/TIA/EIA-485-A-98 ISO 8482:1987 28-SOIC_W_FP SOIC wide body PROFIBUS Modbus RTU BACnet MS-TP solar inverter building automation industrial PLC
Báo giá nhanh RFQ
Hãy điền đầy đủ thông tin — đội ngũ bán hàng của chúng tôi sẽ phản hồi trong vòng 24 giờ
Mã sản phẩm Nhà sản xuất Kiểu đóng gói QTY Giá mục tiêu Phụ
✓
Báo giá đã gửi!

Chúng tôi sẽ trả lời email của bạn trong vòng 24 giờ

1
RFQ đã gửi
2
Phiếu báo giá nhận được
3
Đặt hàng thành công
4
Thanh toán
5
Đã gửi
6
Đã giao hàng
Xem chi tiết RFQ