ADS1147IPW - 16-Bit 2kSPS Precision ADC | Texas Instruments
MPN: ADS1147IPW ✓ Hoạt độngADS1147IPW Tóm tắt
An analog-to-digital converter converts continuous analog voltages into digital values for measurement, control, monitoring, and data logging. The ADS1147IPW belongs to the delta-sigma ADC family within the broader data-converter and signal-chain hierarchy. Its integration of a programmable gain amplifier, precision reference, excitation sources, oscillator, and digital filter reduces the number of external components required in precision sensor-measurement systems.
The 16-bit conversion resolution supports detailed representation of low-level sensor outputs, while the 2kSPS conversion rate is appropriate for temperature, pressure, strain, and industrial process measurements that do not require high-speed waveform acquisition. The programmable PGA increases sensitivity to weak differential signals before conversion. Two matched IDAC outputs can provide excitation for resistive sensors, and the internal low-drift reference supports repeatable measurements without a separate reference source.
The device uses a precision delta-sigma architecture with a single-cycle-settling digital filter. This filtering architecture favors accurate conversion of slowly varying or low-frequency signals and supports rejection of out-of-band noise when the filter and data rate are selected appropriately. The internal oscillator and integrated reference simplify synchronization requirements in compact sensor modules.
Typical applications include RTD measurement, thermocouple instrumentation, thermistor signal acquisition, bridge-based pressure sensing, strain-gauge conditioning, and multichannel industrial measurement. The two differential inputs permit paired positive and negative signal measurement, which is particularly useful when sensor outputs are small and common-mode voltage must be rejected.
PCB design should keep analog inputs short and place input filtering close to the ADC pins. Use a quiet reference and ground layout because reference noise, thermocouple junctions, and high-impedance sensor lines can directly affect conversion accuracy. Verify the required external components and digital interface timing in the manufacturer datasheet before finalizing the sensor front end.
This page consolidates the device specifications, verified sourcing data, application guidance, design considerations, and defensible replacement options into one engineering reference. It also distinguishes electrically equivalent ordering variants from true drop-in alternatives, helping designers avoid assuming that similar resolution or package size alone guarantees pin compatibility.
Bộ thay thế dễ dàng lắp đặt cho ADS1147IPW — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
ADS1147IPWR
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
ADS1147IPW Tỷ lệ tối đa & tính chất điện
| Độ phân giải | 16 bit |
| Conversion Rate | 2 kSPS |
| ADC Architecture | 1 sigma-delta |
| Differential Input Count | 2 inputs |
| Programmable Gain Amplifier | Integrated, programmable gain |
| Internal Reference | Low-drift internal voltage reference with 10 mA output capability |
| Excitation Current Sources | 2 matched programmable IDACs |
| Digital Filter | Single-cycle-settling digital filter |
| Internal Oscillator | Integrated internal oscillator |
| Khoảng nhiệt độ hoạt động | -40 C to +105 C |
| Hộp | 20-pin TSSOP (PW) |
| Kiểu lắp đặt | Surface mount |
| Trạng thái RoHS | Compliant |
Hướng dẫn cấu hình chân ADS1147IPW 20-pin tssop (pw)
Cấu hình chân cho ADS1147IPW (20-pin tssop (pw) gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho ADS1147IPW.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
ADS1147IPW phù hợp cho 6 Áp dụngs: RTD Temperature Measurement, Thermocouple Instrumentation, Thermistor Signal Acquisition, Bridge Pressure Sensor Interface, Strain Gauge Conditioning, Multichannel Industrial Sensor Monitoring.
RTD Temperature Measurement
The ADS1147IPW fits resistance temperature detector measurement because its 16-bit resolution and programmable gain amplifier can capture small resistance-driven voltage changes with high sensitivity. Two programmable excitation current sources support the sensor bridge while the low-drift internal reference improves measurement repeatability. Configure the differential input, PGA gain, and excitation current for the RTD and installation environment, then select a digital-filter setting that matches the required thermal response time.
Được đề xuất
Thermocouple Instrumentation
The ADS1147IPW is appropriate for low-level thermocouple signals because the 16-bit converter and programmable gain amplifier support precise measurement of small differential voltages. Its two differential inputs allow the converter to measure the thermocouple junction voltage relative to a local reference, while the internal reference supports a compact implementation. Careful cold-junction compensation, input filtering, and grounded thermocouple connections remain essential because these errors can dominate the sensor signal.
Được đề xuất
Thermistor Signal Acquisition
The ADS1147IPW supports thermistor acquisition where resistance changes produce relatively small analog variations and high-resolution conversion is valuable. The programmable PGA can amplify the sensor signal before digitization, while the 2kSPS rate is suitable for many temperature-control and monitoring loops. Select the excitation level and gain carefully to avoid exceeding the analog input limits or compressing useful signal range near the measured temperature.
Được đề xuất
Bridge Pressure Sensor Interface
The ADS1147IPW is well suited to resistive bridge pressure sensors because it combines differential input measurement, a programmable gain amplifier, and two matched excitation current sources. This integrated signal chain helps reduce the number of external analog components required around the bridge. The 2kSPS conversion rate and selectable digital filter are appropriate for slow pressure changes, while differential measurement suppresses common-mode variation and excitation current supports controlled bridge excitation.
Được đề xuất
Strain Gauge Conditioning
The ADS1147IPW can digitize low-level strain-gauge bridge outputs when measurement resolution, common-mode rejection, and integrated excitation are priorities. Its 16-bit resolution preserves detail from small mechanical strains, and the programmable PGA increases the usable signal level before conversion. The two matched IDAC outputs can drive the bridge, but excitation drift, resistor tolerances, and differential input noise still influence the complete measurement chain.
Được đề xuất
Multichannel Industrial Sensor Monitoring
The ADS1147IPW supports compact industrial monitoring modules that require accurate conversion of multiple low-level differential sensor signals. Its two differential inputs, integrated PGA, internal reference, and dual excitation outputs reduce front-end complexity, and the 2kSPS rate suits many process variables that change slowly. Channel selection, settling behavior, and digital filtering must be coordinated so that each measurement receives the required acquisition time and rejection of out-of-band noise.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho ADS1147IPW — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | ADS1147IPWR |
|---|---|---|
| Package | 20-pin TSSOP (PW) | 20-pin TSSOP (PW) |
| Brand | Texas Instruments | Texas Instruments |
| Resolution | 16 bit | 16 bit |
| Conversion Rate | 2 kSPS | 2 kSPS |
| ADC Architecture | Sigma-delta | Sigma-delta |
| Differential Inputs | 2 inputs | 2 inputs |
| Integrated Features | Programmable PGA, low-drift reference, 2 matched IDACs, internal oscillator | Programmable PGA, low-drift reference, 2 matched IDACs, internal oscillator |
| Operating Temperature Range | -40 C to +105 C | -40 C to +105 C |
| Lifecycle Status | Active | Active |
| RoHS Status | Compliant | Compliant |
Bảo phân biệt quan trọng
- Complete precision sensor front end (vsADS1147IPWR)
- Two-channel differential measurement (vsADS1147IPWR)
- Single-cycle-settling digital filtering (vsADS1147IPWR)
Ghi chú thiết kế
Route analog inputs as short, symmetric traces away from digital clocks, SPI activity, and switching-regulator paths. Place differential input filtering close to the ADS1147IPW so that high-frequency interference is attenuated before reaching the converter. Keep the analog and digital ground connections within the manufacturer grounding architecture, and avoid routing input traces beneath noisy or rapidly switching nets.
Do not treat the ADS1147IPWR suffix change as a functional redesign; use it when its packing method matches the assembly process. Conversely, do not assume that another ADC in a 20-pin TSSOP package is pin-compatible merely because its outline matches. Check the complete terminal assignment, input multiplexing, supply pins, digital interface, acquisition timing, and register behavior before approving a cross-family replacement.
Select the digital-filter data rate to reject noise outside the intended measurement bandwidth without introducing an unnecessarily long conversion delay. For RTDs, thermistors, and bridge sensors, optimize PGA gain, excitation current, and filtering together so that the full-scale signal range is used without clipping. Confirm settling behavior before multiplexing between differential inputs when measuring rapidly changing process variables.
Use the manufacturer reference layout and recommended external-component values as the starting point for the analog front end. Pay particular attention to reference bypass placement and the return path for the differential sensor inputs. When thermocouples are used, keep copper away from the measurement junction and account for thermal gradients because board heating can create errors comparable to the sensor signal.
Thông tin tuân thủ
The component cross-reference record identifies the ADS1147IPW and ADS1147IPWR as RoHS-compliant and active. No qualified AEC-Q100, REACH, halogen-free, or conflict-minerals conclusion is established by the cited information.