Texas Instruments

ADS1201U - 24-Bit 1 kSPS Delta-Sigma ADC | Texas Instruments

MPN: ADS1201U ✗ Cuối đời
16-pin SOIC Package
MOQ: 1 |

ADS1201U Tóm tắt

The Texas Instruments ADS1201U is a 24-bit high-dynamic-range delta-sigma modulator with a fully differential input, 1 kSPS conversion rate, and two-wire serial interface in a 16-pin SOIC package. It supports internal or external voltage references and includes on-chip switches for calibration, making it suitable for precision analog measurement systems requiring high dynamic range and low-noise signal acquisition.

A delta-sigma ADC is a signal-conversion IC that uses oversampling, noise shaping, and digital filtering to convert an analog input into a high-resolution digital result. Within the ADC hierarchy, the ADS1201U belongs to the delta-sigma modulator family, provides analog-to-digital conversion, and ultimately functions as a precision data-conversion IC. Its fully differential architecture is particularly useful when the source has a small voltage across a common-mode range and benefits from rejection of common-mode noise.

Key features include a nominal 24-bit resolution, a 1 kSPS data rate, and approximately 130 dB of dynamic range. The two-wire interface reduces the number of serial connections required between the converter and a controller. The differential input supports single-ended or differential source arrangements when paired with suitable front-end circuitry, while selectable internal or external references allow the reference voltage to be matched to the transducer and analog signal chain.

The delta-sigma architecture trades conversion speed for resolution and noise performance. It is most effective for slowly changing or precision-oriented signals rather than high-bandwidth waveform acquisition. The on-chip calibration switches support system-level calibration, and the 16-pin SOIC package permits assembly using conventional surface-mount production methods. Maximum power dissipation is reported as 40 mW, making thermal design relatively manageable in typical precision-measurement equipment.

Typical uses include pressure and load-cell signal conditioning, industrial sensor acquisition, instrumentation amplifiers, weigh systems, and low-frequency measurement front ends. A controller can read the serial output and perform digital filtering or scaling as required by the measurement system. The differential input can also front-end sensor bridges where preserving signal integrity and rejecting common-mode disturbances are priorities.

Designers should verify the required analog bandwidth, digital-filter settling time, reference configuration, and serial timing before fixing the system sampling strategy. Input protection, reference bypassing, and a quiet ground layout are important because they can affect achievable resolution. The 40 mW maximum power dissipation rating provides a useful starting point, but actual board-level thermal behavior should be checked against the final operating conditions.

This page consolidates verified manufacturer and distributor information, lifecycle context, candidate replacements, and practical selection guidance. It also distinguishes confirmed device attributes from parameters that still require verification, helping engineers shorten datasheet review and replacement-planning time without inventing unavailable electrical details.

Bộ thay thế dễ dàng lắp đặt cho ADS1201U — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.

Các biến thể trong loạt này

Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với ADS1201U (cùng hình factor và footprint) — khác nhau ở Package, Effective Resolution, Maximum Conversion Rate, RMS Noise, Supply Voltage.

Texas Instruments
Package: 8-pin SOIC
Effective Resolution: 19 bits at conversion rates up to 20kHz
Maximum Conversion Rate: 20kHz
So sánh với ADS1201U →
Texas Instruments
Package: 8-pin SOIC
Effective Resolution: 19 bits up to 40 kHz
Maximum Conversion Rate: 40 kSPS
So sánh với ADS1201U →

ADS1204

✅ Drop-In
📦 16-pin SOIC
ADS1201 uses a two-wire interface at 1 kSPS, while ADS1204 uses a distinct clocked serial interface; interface timing and final pin compatibility must be confirmed before substitution

📋 Tham chiếu thay thế (không có trong danh mục)

ADS1209

✅ Drop-In
📦 16-pin SOIC
ADS1209 differs from the 1 kSPS ADS1201 by using a distinct serial interface and conversion-rate configuration, creating up to a 30% class of functional difference pending exact datasheet review

📋 Tham chiếu thay thế (không có trong danh mục)

ADS1251U

✅ Drop-In
Texas Instruments
📦 16-pin SOIC
24 bits · 19 bits at conversion rates up to 20kHz · 20kHz · Delta-sigma · 1 differential input · 5 V · 24 bits · 1.5ppm

Liên hệ để biết giá

Xem tài liệu →

ADS1252U

✅ Drop-In
Texas Instruments
📦 16-pin SOIC
24 bits · 40 kSPS · 19 bits up to 40 kHz · 2.5 ppm RMS · Delta-sigma · 1 differential input · Single +5 V · 24 bits

Liên hệ để biết giá

Xem tài liệu →

ADS1202U

✅ Drop-In ⚠️ Thông số chưa được xác minh
📦 16-pin SOIC
ADS1202U is a related 24-bit delta-sigma converter with a lower conversion rate than the 1 kSPS ADS1201U, producing a functional difference of at least 80% unless the original design operates well below 1 kSPS

📋 Tham chiếu thay thế (không có trong danh mục)

ADS1201U Tỷ lệ tối đa & tính chất điện

ADC Architecture Delta-sigma modulator
Nominal Resolution 24 bit
Conversion Rate 1 kSPS
Dynamic Range 130 dB
Input Architecture Fully differential
Digital Interface 2-wire serial
Reference Options Internal or external
Calibration Support On-chip switches
Channel Count 1 channel
Maximum Power Dissipation 40 mW
Hộp 16-pin SOIC
Kiểu lắp đặt Surface mount

Hướng dẫn cấu hình chân ADS1201U 16-pin soic

Cấu hình chân cho ADS1201U (16-pin soic gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.

Bảng cấu hình chân 16-pin soic cho ADS1201U

Không có dữ liệu chân cụ thể sẵn có cho ADS1201U.

Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.

Ứng dụng tiêu biểu

ADS1201U phù hợp cho 6 Áp dụngs: Load-Cell and Strain-Gauge Measurement, Industrial Pressure Transducer Interface, Precision Instrumentation and Test Equipment, Weighing and Material-Flow Systems, Low-Level Sensor Signal Acquisition, Medical and Environmental Monitoring.

🏭

Load-Cell and Strain-Gauge Measurement

The ADS1201U fits low-level bridge measurements because its fully differential input is compatible with the small differential signals produced by strain gauges, while its nominal 24-bit resolution and approximately 130 dB dynamic range provide substantial conversion headroom. Place the bridge and converter in a quiet analog section, connect the bridge excitation to a clean reference source, and use the internal or external reference option selected for the required dynamic range. At 1 kSPS, the converter favors temperature, force, and weight measurements that change more slowly than waveform acquisition. The main design consideration is that achieved system accuracy will depend more heavily on excitation noise, bridge layout, input protection, and digital averaging than on nominal resolution alone.

🏭

Industrial Pressure Transducer Interface

ADS1201U is appropriate for industrial pressure transmitters that present a small differential voltage and require more resolution than a conventional low-cost ADC. The 24-bit nominal resolution and approximately 130 dB dynamic range can help preserve signal integrity across a wide measurement range, while the fully differential input avoids forcing the transducer signal onto a sensitive ground referenced only to the digital return. The 1 kSPS conversion rate is normally more than sufficient for pressure changes associated with machinery, hydraulics, or process vessels. Use a low-noise excitation source, shield analog input routing, and isolate the converter from motors, relays, and switching supplies. Calibration can be supported through the ADS1201's on-chip switches, although the exact calibration sequence must follow the manufacturer procedure.

🔧

Precision Instrumentation and Test Equipment

The ADS1201U can serve as the measurement converter in slow, high-resolution laboratory or industrial instrumentation where the signal bandwidth is well below the nominal 1 kSPS conversion rate. Its approximately 130 dB dynamic range and 24-bit nominal resolution are valuable when the system must resolve small changes over a broad input range, and the two-wire interface can simplify connections to a dedicated measurement controller. The delta-sigma trade-off is filtered settling time: the digital filter must be allowed to converge before each result is used. Engineers should characterize noise bandwidth, line rejection, reference stability, and conversion latency rather than assuming the nominal bit count determines usable resolution. Keep digital return currents out of the sensitive input and reference paths.

⚡

Weighing and Material-Flow Systems

ADS1201U suits weighing platforms, hopper scales, and material-flow equipment because load-cell outputs are differential, low level, and normally vary slowly. The fully differential input accepts the bridge output directly when the front-end polarity and common-mode range are compatible, while 24-bit nominal resolution and approximately 130 dB dynamic range provide a strong starting point for fine resolution. The 1 kSPS conversion rate supports measurement rather than high-speed dynamics. In real installations, vibration from motors and feeders can dominate the noise floor, so mechanical isolation, filtering, shielding, and synchronized averaging remain important. The reference configuration must also be selected carefully because excitation and reference errors can appear as measurement gain errors even when the converter's own resolution is high.

🧩

Low-Level Sensor Signal Acquisition

ADS1201U is applicable to low-level sensor front ends when the signal must be digitized with high resolution but does not require rapid sampling. The converter's fully differential architecture is advantageous for sensors whose useful output is a small voltage centered on a common-mode voltage, and the two-wire serial connection reduces interface complexity in distributed measurement nodes. Its 1 kSPS rate should be compared with the sensor bandwidth and required response time, while the delta-sigma filter must be included in the system response model. For thermocouples, resistive sensors, and similar inputs, an appropriate amplifier and protection network remain necessary. Verify input range, reference voltage, supply limits, and common-mode behavior against the manufacturer electrical table before selecting passive and amplifier components.

💊

Medical and Environmental Monitoring

ADS1201U can be evaluated for slow-changing biomedical or environmental signals when the front end provides a suitable differential output and the required diagnostic bandwidth is modest. The nominal 24-bit resolution, approximately 130 dB dynamic range, and internal or external reference flexibility support precise acquisition from resistive, strain, or bridge-derived sensors. The 1 kSPS conversion rate is suitable for many temperature, pressure, flow, and biochemical monitoring signals, but the system must account for digital-filter settling time. Patient-connected designs require separate consideration of isolation, leakage, applied limits, and regulatory validation because those requirements are not established in the supplied ADS1201U data. A practical design should minimize analog trace length, maintain quiet reference grounding, and verify sensor excitation stability.

Tóm tắt các sản phẩm được đề xuất

ADS1201U/1K Same ADS1201 device offered in a distributor-listed packaged configuration Được sử dụng trong: Load-Cell and Strain-Gauge Measurement, Weighing and Material-Flow Systems ADS1252U Texas Instruments Được sử dụng trong: Load-Cell and Strain-Gauge Measurement, Precision Instrumentation and Test Equipment, Weighing and Material-Flow Systems, Medical and Environmental Monitoring ADS1204 Related Texas Instruments delta-sigma converter for interface evaluation Được sử dụng trong: Industrial Pressure Transducer Interface, Low-Level Sensor Signal Acquisition, Medical and Environmental Monitoring ADS1209 Related Texas Instruments conversion family identified in TI substitution guidance Được sử dụng trong: Industrial Pressure Transducer Interface, Low-Level Sensor Signal Acquisition ADS1251U Texas Instruments Được sử dụng trong: Precision Instrumentation and Test Equipment
What are the key specifications of ADS1201U that engineers should know?
The ADS1201U is a 24-bit, 1 kSPS, fully differential delta-sigma ADC with approximately 130 dB dynamic range and a two-wire serial interface. According to the Texas Instruments ADS1201U datasheet, it accepts internal or external references and provides on-chip switches for calibration. The device is offered in a 16-pin SOIC package, and distributor listings identify it as a single-channel modulator rather than a conventional multi-channel SAR ADC.
What is the operating voltage range of ADS1201U?
The supplied verified information does not state the ADS1201U operating-voltage range, so a numeric supply specification should not be inferred. According to the manufacturer datasheet, ADS1201U is a precision delta-sigma modulator with a fully differential input and selectable internal or external reference. Check the device's electrical-characteristics table before designing the supply rails, decoupling network, reference circuit, or digital interface.
What resolution and sampling rate does ADS1201U provide?
ADS1201U provides a nominal 24-bit resolution and a 1 kSPS conversion rate. According to the Texas Instruments ADS1201U datasheet, it is a high-dynamic-range delta-sigma modulator with approximately 130 dB dynamic range. This combination is intended for precision, relatively slow-changing analog measurements rather than high-speed sampling, and the usable output should also be evaluated against the device's digital filter behavior.
Where to buy ADS1201U online?
ADS1201U can be found through Texas Instruments-authorized distribution channels, including DigiKey, Mouser, Arrow, and Octopart listings. The verified DigiKey page identifies it as a 24-bit, 1 kSPS serial converter in a 16-pin SOIC package, while Mouser and Arrow provide additional inventory and ordering links. Pricing shown on this page is unavailable because the supplied web data did not contain numeric price values as of 2026-10-28.
What is the price of ADS1201U?
A verified numeric price for ADS1201U is not present in the supplied distributor snippets, so no price is represented as authoritative. According to the DigiKey, Mouser, Arrow, and Octopart product listings retrieved for this page, price and availability are presented on their respective websites. Check the distributor listing for a quantity-1 quote and current lifecycle availability as of 2026-10-28 before placing an order.
What is the lead time for ADS1201U?
The verified ADS1201U data does not provide a numeric manufacturer lead time. The Texas Instruments E2E substitution thread states that ADS1201U has been notified as obsolete, so lead time should not be assumed from ordinary active-part inventory behavior. Request an obsolete-part quotation from an authorized distributor and confirm traceability, lot date, and lifecycle terms as of 2026-10-28.
Is ADS1201U in stock?
ADS1201U inventory is not confirmed by the supplied verified data. The DigiKey snippet states that the part can be purchased and shipped today, but the Arrow listing provides a Tube ordering option, indicating that packaged inventory may exist without proving unlimited stock. Because the lifecycle evidence also mentions obsolescence, confirm the exact quantity, condition, and manufacturer traceability directly with the seller as of 2026-10-28.
Where to download the ADS1201U datasheet PDF?
The ADS1201U datasheet can be accessed through the verified Texas Instruments documentation link for this page or through the supplied AllDataSheet PDF page. According to the manufacturer datasheet, the device is a high-dynamic-range delta-sigma modulator with a fully differential input, two-wire interface, internal or external reference, and calibration switches. Use the manufacturer document for design authority and the third-party mirror only for convenient viewing.
Where can I find the ADS1201U pinout?
The ADS1201U pinout must be taken from the Texas Instruments ADS1201U datasheet; a verified, complete pin-number-to-name list was not included in the supplied data, so none is fabricated here. The manufacturer documentation confirms a 16-pin SOIC package and describes the power, ground, analog-input, reference, calibration, and serial-interface connections. Cross-check every net against the official pin table before PCB layout or schematic release.
Is ADS1201U suitable for pressure and load-cell measurement?
Yes, ADS1201U is suitable for slow, precision-oriented sensor measurements such as bridges, strain gauges, and pressure elements. According to the Texas Instruments ADS1201U datasheet, its 24-bit nominal resolution, 1 kSPS rate, fully differential input, and approximately 130 dB dynamic range support low-level differential signals. Practical accuracy will also depend on excitation noise, reference stability, analog-front-end design, and digital filtering.
ADS1201U vs ADS1204 - which is better for precision measurement?
ADS1201U is preferable when a two-wire interface and 1 kSPS conversion rate match the controller connection, while ADS1204 should be evaluated when its separate data, clock, and command paths suit the system better. The Texas Instruments E2E discussion identifies ADS1204 as a substitution candidate for ADS1201, but the verified material does not establish complete pin-to-pin equivalence. Verify the ADS1204 pin table, interface timing, and filter behavior before replacing ADS1201U.
ADS1201U vs ADS1252U - which is better for a bridge amplifier front end?
ADS1201U offers a 24-bit, 1 kSPS delta-sigma modulator with a two-wire interface, while ADS1252U is a distinct delta-sigma ADC family whose programmable-gain characteristics and interface should be reviewed separately. According to the verified comparison search results, ADS1252U and ADS1201U/1K are compared for compliance, package, and related parameters. They should not be treated as drop-in without verifying the exact pinout and control protocol.
When should I choose ADS1201U over another 24-bit delta-sigma ADC?
Choose ADS1201U when the design specifically benefits from its 24-bit resolution, 1 kSPS rate, fully differential input, approximately 130 dB dynamic range, two-wire interface, and internal or external reference options. According to the manufacturer datasheet, its strengths lie in precision rather than throughput. Select another converter when the required bandwidth, digital-filter response, interface, gain architecture, or power budget cannot be met.
What can replace ADS1201U?
ADS1204 and ADS1252U are documented comparison candidates, but the verified sources do not confirm that either is a fully pin-compatible drop-in replacement for ADS1201U. The Texas Instruments E2E thread lists ADS1204 and ADS1209 as substitution topics, while a separate comparison covers ADS1252U. Engineers should compare pin functions, supply voltage, reference behavior, filter response, serial timing, calibration, and acquisition latency before approving a replacement.
What is the best alternative to ADS1201U for an obsolete design?
No cross-brand drop-in replacement can be confirmed from the supplied evidence. Texas Instruments ADS1204, ADS1209, ADS1251U, and ADS1252U are reasonable same-brand parts to investigate because they appear in the verified substitution and comparison results and use related delta-sigma conversion technology. The best replacement is the candidate whose complete pin function, interface timing, electrical limits, and digital-filter behavior exactly match the original PCB.

Dữ liệu tham khảo kỹ thuật cho ADS1201U — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.

Hướng dẫn chọn lựa

Choose ADS1201U when the original design depends on a 24-bit, 1 kSPS delta-sigma conversion stage with a fully differential input, two-wire serial interface, approximately 130 dB dynamic range, and internal or external reference capability. It is particularly appropriate for slow bridge, pressure, strain, and precision instrumentation signals. ADS1204 is worth evaluating when a clocked serial interface is acceptable, but its clock, data, command, and timing connections must be checked against the original PCB. ADS1252U may fit designs needing a related 24-bit delta-sigma ADC with different front-end functions, while ADS1251U should be selected only if lower resolution is acceptable. ADS1202U may suit substantially slower acquisition. Because the lifecycle evidence indicates obsolescence and verified pin-level equivalence data is incomplete, every proposed replacement requires schematic, timing, filter, reference, and PCB compatibility review before approval.

So sánh với các sản phẩm thay thế

Tham số Sản phẩm này ADS1204 ADS1209 ADS1251U ADS1252U ADS1202U
Package 16-pin SOIC 16-pin SOIC - same 16-pin SOIC - same 16-pin SOIC - same 16-pin SOIC - same 16-pin SOIC - same
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments

Bảo phân biệt quan trọng

  • High nominal resolution for low-speed precision acquisition (vsADS1251U)
  • Simplified two-wire control interface (vsADS1204)
  • Verified 130 dB dynamic-range positioning (vsADS1209)
  • Direct support for precision differential bridge signals (vsADS1252U)

Ghi chú thiết kế

Route the differential input as a compact, symmetric pair on a quiet analog layer, with the converter and reference network positioned away from digital clocks and switching-regulator nodes. Keep the analog and digital ground return paths controlled to prevent converter current and serial-interface activity from sharing a high-impedance sensor return. Verify the exact pin assignments against the official ADS1201U datasheet before finalizing the footprint because a complete verified pin list was not included in the supplied source data.

Use the datasheet-recommended supply and reference bypassing values after confirming them from the official electrical-characteristics table. The verified source reports a maximum power dissipation of 40 mW, but that maximum rating does not establish the operating dissipation at every supply, reference, and conversion-rate condition. Keep exposed-pad or package copper requirements for the selected assembly method and check the worst-case supply-to-output difference against the thermal design before production release.

Do not equate the nominal 24-bit resolution with 24 effective bits in an end-to-end measurement. The usable result depends on analog noise, reference accuracy, input bandwidth, filter settling, and the time required for digital averaging. Because ADS1201 is a delta-sigma modulator, include filter latency in control-loop and measurement timing, and use the manufacturer filter characteristics to avoid reporting samples taken before the sinc or digital filter has settled.

The two-wire serial interface reduces connector and trace count, but its clock and data timing still require a clean controller implementation. Check voltage levels, clock polarity, data validity windows, and maximum serial clock rate against the official datasheet. Keep the serial traces short where practical, provide a continuous return path, and isolate slow analog signals from the digital interface to prevent switching current from coupling into the fully differential input.

Thông tin tuân thủ

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Không chì
Unknown
Không halogen
Unknown
Khoáng vật xung đột
Unknown

The supplied verified snippets do not contain explicit compliance declarations for ADS1201U. The comparison search mentions RoHS and REACH for ADS1201U/1K, but the underlying compliance statements were not included, so every compliance field remains unknown.

Dữ liệu được xác minh vào: 2026-10-28 — dữ liệu được xác minh và quản lý bởi đội ngũ kỹ thuật phần cứng của XAIPART

Tìm kiếm liên quan

ADS1201U ADS1201U datasheet Texas Instruments ADS1201U ADS1201U 24-bit 1 kSPS specifications ADS1201U 16-pin SOIC ADS1201U load cell amplifier interface ADS1201U vs ADS1204 ADS1201U vs ADS1252U ADS1201U obsolete replacement ADS1201U buy online ADS1201U price and stock ADS1201U pinout What can replace ADS1201U? ADS1201U pressure sensor ADC ADS1201U 130 dB dynamic range

Các bộ phận và thuật ngữ liên quan

Texas Instruments ADS1201U ADS1201 ADS1204 ADS1209 ADS1251U ADS1252U ADS1202U delta-sigma ADC delta-sigma modulator analog-to-digital converter data-conversion IC 24-bit resolution 1 kSPS conversion rate 130 dB dynamic range fully differential input two-wire serial interface internal voltage reference external voltage reference on-chip calibration switches 16-pin SOIC SOIC package family surface-mount package pressure transducer load-cell measurement
Báo giá nhanh RFQ
Hãy điền đầy đủ thông tin — đội ngũ bán hàng của chúng tôi sẽ phản hồi trong vòng 24 giờ
Mã sản phẩm Nhà sản xuất Kiểu đóng gói QTY Giá mục tiêu Phụ
✓
Báo giá đã gửi!

Chúng tôi sẽ trả lời email của bạn trong vòng 24 giờ

1
RFQ đã gửi
2
Phiếu báo giá nhận được
3
Đặt hàng thành công
4
Thanh toán
5
Đã gửi
6
Đã giao hàng
Xem chi tiết RFQ