AL1306 - IO-Link Master with PROFINET, 8xM12, IP67 | ifm
MPN: AL1306 ✓ Hoạt độngAL1306 Tóm tắt
An IO-Link master is the gateway device that bridges bidirectional IO-Link point-to-point communication between intelligent sensors/actuators and higher-level fieldbus networks such as PROFINET, EtherNet/IP, or EtherCAT. Positioned in the industrial automation hierarchy (sensor/actuator -> IO-Link master -> fieldbus/PROFINET -> PLC/controller -> SCADA/MES), the master translates IO-Link process data, on-request data, and event diagnostics into standard fieldbus telegrams and vice-versa. Unlike conventional digital I/O blocks, an IO-Link master provides parameterization, condition monitoring, and remote diagnostics for each connected IO-Link device.
Key features of the AL1306 include 8 IO-Link ports with M12 A-coded connectors, support for both digital inputs (DI) and digital outputs (DO), a PROFINET industrial Ethernet interface, and an integrated IoT port for higher-level connectivity. The FKM seal on each M12 port provides chemical resistance suited to factory environments with oils, coolants, and cleaning agents. The IP67 housing allows direct machine mounting without an additional enclosure.
Technically, the AL1306 implements the IO-Link specification v1.1 and PROFINET RT conformance class B, providing cycle times suitable for typical sensor/actuator polling. Each IO-Link port can be independently configured as DI, DO, or IO-Link (SDCI), and the master supports port-specific parameter storage and validation. The device supports standard PROFINET diagnostics and integrates with ifm's moneo|configure and LR DEVICE commissioning tools.
Typical applications include automotive body shop assembly lines, machine tool spindle monitoring, packaging machinery sensor networks, and process plant instrument networks. The wide 20-30 V DC supply range accommodates 24 V industrial control cabinets with voltage tolerance, and the IP67 rating enables direct mounting on machines without protective cabinets. The PROFINET interface allows integration into Siemens SIMATIC environments as well as third-party PROFINET controllers.
When designing with the AL1306, verify PROFINET device description (GSDML) compatibility with the target controller. Use ifm-supplied E12367 (or current equivalent) cables to maintain IP67 integrity, and reserve the IoT port for cloud/edge gateway connectivity if required by the application. Plan GSDML import and node commissioning before physical installation to avoid commissioning delays on the plant floor.
Bộ thay thế dễ dàng lắp đặt cho AL1306 — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với AL1306 (cùng hình factor và footprint) — khác nhau ở Connector Type, Fieldbus Protocol, Manufacturer, Product Type.
AL1352
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
AL1302
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
AL1322
✅ Drop-In ⚠️ Thông số chưa được xác minhLiên hệ để biết giá
Xem tài liệu →BNI EIP-508-005-Z015
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
TBEN-S2-8IOL
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
AL1306 Thông số kỹ thuật (bản công bố của nhà sản xuất)
| Product Type | IO-Link Master with PROFINET interface |
| Manufacturer | ifm efector, inc. |
| Part Number | AL1306 |
| Fieldbus Protocol | PROFINET |
| IO-Link Ports | 8 |
| Connector Type | M12, A-coded, 4-pin |
| Sealing Material | FKM |
| Total Digital Inputs | 12 |
| Total Digital Outputs | 8 |
| Operating Voltage | 20-30 V DC |
| Protection Rating | IP67 (dust tight, waterproof) |
| Housing Color | Orange |
| Number of Connector Openings | 12 |
| IoT Port | Yes |
| Kiểu lắp đặt | Field mountable |
Giao diện và cáp kết nối AL1306
Hiện tại không có danh sách giao diện do nhà sản xuất công bố cho AL1306. Tham khảo tài liệu hướng dẫn của nhà sản xuất cho chi tiết về cáp kết nối và chân.
Tham khảo: hướng dẫn của nhà sản xuất cho bản đồ chân cổng mở rộng và số thứ tự chân kết nối đầy đủ.
Ứng dụng tiêu biểu
AL1306 phù hợp cho 6 Áp dụngs: Automotive Body Shop Assembly Line, Machine Tool Spindle Monitoring, Packaging Machinery Sensor Networks, Process Plant Instrument Networks, Conveyor and Material Handling Systems, Smart Factory Edge Connectivity.
Automotive Body Shop Assembly Line
The AL1306's IP67 rating, M12 A-coded connectors, and FKM sealing make it well-suited for automotive body shop environments with exposure to welding spatter, oils, and cleaning agents. With 8 IO-Link ports supporting up to 12 digital inputs and 8 digital outputs, a single master can aggregate sensors on a robotic weld cell or fixture, transmitting data via PROFINET to a Siemens SIMATIC S7 controller. The PROFINET conformance class B capability ensures deterministic cycle times for body-in-white sequencing. Placed in the cell's cable tray with ifm E12367 M12 cordsets, the master reduces I/O wiring complexity compared to home-run discrete wiring back to the cabinet.
Được đề xuất
Machine Tool Spindle Monitoring
For machine tool spindle and tool-monitoring applications, the AL1306 aggregates vibration, temperature, and presence sensors connected via IO-Link to a CNC controller over PROFINET. Each IO-Link port can carry both process data and on-request parameter data, enabling real-time spindle health monitoring without dedicated wiring. The 20-30 V DC supply range tolerates typical machine tool 24 V cabinet rails, while the IP67 rating supports mounting near the spindle where coolant and chip exposure would damage IP20 industrial blocks. Compared to conventional I/O, IO-Link diagnostics reduce commissioning time and enable predictive maintenance workflows.
Được đề xuất
Packaging Machinery Sensor Networks
In packaging lines, the AL1306 provides 8 IO-Link ports for photoelectric, inductive, and capacitive sensors detecting labels, caps, fill levels, and product presence. PROFINET integration with the line PLC enables recipe-driven sensor reconfiguration on SKU changeover, replacing manual potentiometer adjustments with IO-Link parameter download. The IP67 housing allows direct mounting on the packaging machine frame, eliminating long home-run cable runs and reducing EMC noise pickup. The 12-input/8-output digital I/O budget supports e-stop chains, light curtains, and reject mechanisms alongside IO-Link sensors on shared port hardware.
Được đề xuất
Process Plant Instrument Networks
For process plants, the AL1306 acts as the fieldbus aggregation point for IO-Link-enabled pressure, level, flow, and analytical instruments in non-hazardous areas. PROFINET integration with the plant DCS allows centralized instrument management via ifm moneo|configure, with diagnostic data flowing back through the IoT port for asset-health dashboards. The 20-30 V DC supply range accommodates plant 24 V DC distribution, and the M12 connectors provide vibration-resistant terminations suitable for pump skids and compressor packages. Compared to 4-20 mA analog loops, IO-Link delivers richer diagnostics and parameter portability.
Được đề xuất
Conveyor and Material Handling Systems
The AL1306 supports conveyor zone control networks by aggregating photoeyes, motor starters, and encoder feedback over IO-Link and transmitting zone status to a PROFINET PLC. The 12 digital inputs handle e-stop status, zero-speed sensors, and motor contactor feedback, while 8 digital outputs drive motor starters or diverters. M12 A-coded connectors with FKM seals withstand pallet washdown environments common in food/beverage conveyor systems. Compared to AS-Interface, IO-Link enables per-zone condition monitoring and reduces commissioning time via ifm moneo|configure automatic device replacement.
Được đề xuất
Smart Factory Edge Connectivity
For smart factory initiatives, the AL1306's IoT port provides a parallel TCP/IP channel for cloud/edge gateway connectivity, enabling sensor data to flow simultaneously to the PROFINET PLC and a higher-level analytics platform. The same IO-Link sensor data that drives the line control loop is mirrored to the IoT port for predictive maintenance, OEE dashboards, or MES integration without impacting real-time PROFINET performance. With 8 IO-Link ports aggregating instrument data and IP67 field-mountability, the AL1306 reduces the need for separate edge gateways and simplifies the brownfield-to-smart-factory migration path.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho AL1306 — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | AL1352 | AL1302 | AL1322 | BNI EIP-508-005-Z015 | TBEN-S2-8IOL |
|---|---|---|---|---|---|---|
| Brand | ifm | ifm | ifm | ifm | Balluff | Turck |
| Package | IP67 field-mountable, 8x M12 ports | IP67 field-mountable, 8x M12 ports - same | IP67 field-mountable, 8x M12 ports - same | IP67 field-mountable, 8x M12 ports - same | IP67 field-mountable, 8x M12 ports - same | IP67 field-mountable, 8x M12 ports - same |
| Fieldbus Protocol | PROFINET | EtherNet/IP | PROFINET | EtherNet/IP | EtherNet/IP | PROFINET or EtherNet/IP (variant) |
| IO-Link Ports | 8 | 8 | 8 | 8 (4 IO-Link + 4 DIO) | 8 | 8 |
| Digital Inputs Total | 12 | 12 | 12 | 8 | 12 | 12 |
| Digital Outputs Total | 8 | 8 | 8 | 4 | 8 | 8 |
| Operating Voltage | 20-30 V DC | 20-30 V DC | 20-30 V DC | 20-30 V DC | 18-30 V DC | 18-30 V DC |
| Protection Rating | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 |
| IoT Port | Yes | Yes | No | No | No | Optional |
Bảo phân biệt quan trọng
- Integrated IoT port for parallel cloud/edge connectivity (vsAL1302)
- PROFINET conformance class B support (vsBNI EIP-508-005-Z015 (Balluff))
- 8x M12 A-coded with FKM sealing for chemical resistance (vsTBEN-S2-8IOL (Turck))
Ghi chú thiết kế
The AL1306 requires a regulated 24 V DC supply within 20-30 V tolerance per the ifm datasheet. Use a dedicated 24 V branch circuit with adequate current capacity; each IO-Link port can source up to 200 mA per port typical for IO-Link Class A operation, totaling up to 1.6 A across 8 ports under worst-case sensor load. Verify the upstream power supply's overload capacity and use ifm-recommended M12 power cables to maintain IP67 integrity.
Mount the AL1306 in an accessible location that allows M12 cable routing without sharp bends; minimum bend radius for ifm E12367 M12 cordsets is 5x cable diameter. Allow 50 mm clearance around the device for connector access during commissioning and replacement. Position the master to minimize total IO-Link cable length to sensors (each port cable should be <20 m per IO-Link specification).
Do not mix standard M12 A-coded sensor cables with M12 power cables on the AL1306 - the IO-Link master requires A-coded 4-pin cables for IO-Link ports and dedicated power cables for supply input. Ensure the PROFINET GSDML is imported before physical connection to the network, and verify the device name assigned matches the PROFINET engineering tool configuration. Failing to update the GSDML after firmware updates is a common commissioning failure.
Thông tin tuân thủ
Industrial automation product with CE marking per EU EMC and Machinery Directives; IP67 rating per IEC 60529. RoHS and REACH compliant per EU declarations on ifm product page.