DG211CUE+ - 4-Channel 175Ω SPST Analog Switch | Analog
MPN: DG211CUE+ ✓ Hoạt độngDG211CUE+ Tóm tắt
An analog switch is a semiconductor device that connects or isolates circuit nodes under digital control while preserving the electrical characteristics of the passing signal. The DG211 belongs to the CMOS analog switch hierarchy, which also includes multiplexers, selectors, and routing switches. Its normally closed configuration keeps each selected signal path connected until the corresponding control input commands a break, making the DG211 useful in test systems, audio routing networks, measurement equipment, and configurable signal-conditioning circuits.
Key characteristics include four independent SPST channels, 1:1 signal routing, a 175 Ω maximum on-resistance, and low 5 nA leakage. Break-before-make behavior prevents the momentary overlap of old and new paths that could produce an invalid signal during transition. The manufacturer also guarantees latch-up protection when the power supplies are disconnected while input signals remain connected, improving robustness in equipment where rails can collapse before signal sources.
The DG211 uses CMOS construction to provide low off-leakage and low power consumption while operating across a wide voltage range. Its maximum switching interval is 1 μs, with a specified turn-off time no greater than 500 ns. Because on-resistance is 175 Ω at the maximum rating, the switch introduces insertion loss and contributes to noise when used in high-impedance precision paths. The device is therefore most appropriate for moderate-bandwidth routing rather than low-loss RF distribution.
Typical uses include four-channel test and measurement systems, audio input and output routing, instrumentation signal selection, and industrial control interfaces. In each case, the control logic determines which normally closed path remains connected. The commercial DG211CUE+ is suited to room-temperature equipment, while extended-temperature or automotive requirements call for a qualified grade rather than this commercial-temperature variant.
When laying out the board, route each switched signal away from digital control traces and provide a solid ground reference around the package. Keep power-supply decoupling close to the device and verify that every signal node remains within its absolute maximum rating, especially during power sequencing. This page combines device specifications, family-level alternatives, comparison data, and practical layout guidance for faster design review.
Bộ thay thế dễ dàng lắp đặt cho DG211CUE+ — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
DG211CUE+T
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
DG211CUA+
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
DG211CUB+
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
DG211CUC+
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
DG211CUE+ Tỷ lệ tối đa & tính chất điện
| Number of Channels | 4 channels |
| Switch Configuration | 4 x SPST |
| Switch State | Normally closed (NC) |
| Signal Configuration | 1:1 |
| On-Resistance | 175 Ω maximum |
| Minimum Dual Supply Voltage | ±4.5 V |
| Maximum Dual Supply Voltage | ±18 V |
| Nhiệt độ hoạt động | 0 °C to +70 °C |
| Turn-Off Time | 500 ns maximum |
| Maximum Switching Interval | 1 μs |
| Off Leakage | 5 nA |
| Switching Behavior | Break-before-make |
| Latch-Up Protection | Guaranteed with input signals connected during power-supply disconnect |
| Số lượng chân | 16 pins |
| Hộp | 16-TSSOP, 0.173 in × 4.40 mm |
| Kiểu lắp đặt | Surface mount (SMD/SMT) |
| Technology | CMOS analog switch |
Hướng dẫn cấu hình chân DG211CUE+ 16-tssop, 0.173 in × 4.40 mm
Cấu hình chân cho DG211CUE+ (16-tssop, 0.173 in × 4.40 mm gói). Số thứ tự chân, chức năng và sơ đồ kết nối được xác định trong tài liệu thông số kỹ thuật của nhà sản xuất. Tham khảo nó để biết footprint và hướng dẫn hàn chính xác.
Không có dữ liệu chân cụ thể sẵn có cho DG211CUE+.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
DG211CUE+ phù hợp cho 6 Áp dụngs: Four-Channel Test Signal Routing, Audio Input and Output Selection, Instrumentation Signal Conditioning, Industrial Control Signal Isolation, Programmable Signal-Fault Injection, Configurable Analog Sensor Interface.
Four-Channel Test Signal Routing
The DG211CUE+ fits four-channel test systems that must connect or isolate several external fixtures without changing the central analog path. Each normally closed SPST channel provides a direct 1:1 route with a maximum on-resistance of 175 Ω, while control inputs determine which paths remain active. A maximum turn-off time of 500 ns and guaranteed break-before-make operation help prevent two driven fixtures from overlapping during a transition. Place the switch close to the routed connectors, keep return paths short, and confirm that fixture drive levels remain within the switch signal ratings.
Được đề xuất
Audio Input and Output Selection
The DG211CUE+ can select among audio paths in a compact routing network because it provides four independent normally closed channels and a 175 Ω maximum on-resistance. The 16-TSSOP package keeps routing density high, while the 500 ns maximum turn-off time is adequate for control-level audio switching rather than high-frequency RF distribution. Keep the signal path short and observe the maximum signal swing shown in the family documentation. For headphone outputs, verify that the source and load impedances do not make the switch resistance a significant source of level loss.
Được đề xuất
Instrumentation Signal Conditioning
The DG211CUE+ is useful when a measurement front end must route several conditioned inputs to a shared amplifier, ADC, or display channel. Its four 1:1 SPST paths avoid the multi-source contention that can occur when an external source is permanently tied to a sensitive input. The normally closed state provides a defined default connection, and the 5 nA off-leakage figure helps limit unwanted coupling between disconnected channels. Place the device upstream of high-impedance circuitry and maintain a low-impedance ground connection to minimize pickup.
Được đề xuất
Industrial Control Signal Isolation
The DG211CUE+ can isolate four control or sensor lines from a shared controller in industrial equipment. Its guaranteed break-before-make operation prevents an overlap interval during route changes, and the latch-up protection supports power-down conditions where external control signals remain active. Because the commercial variant operates from 0 °C to +70 °C, it is appropriate for indoor or temperature-controlled equipment; select an extended-temperature grade for harsher industrial environments. Validate the control polarity and off-state leakage against the connected actuator or sensor interface.
Được đề xuất
Programmable Signal-Fault Injection
The DG211CUE+ can implement controlled opens and closed loops in board test fixtures by configuring each normally closed channel in series with a test node. A 1 μs maximum switching interval and break-before-make behavior allow the fixture controller to change connection states with defined sequencing. Place the switch close to the device-under-test connector to limit fixture-induced capacitance and reflections. When injecting faults, confirm that the external fixture voltage stays inside the permitted signal range and does not exceed the power rails during transitions.
Được đề xuất
Configurable Analog Sensor Interface
The DG211CUE+ supports modular sensor interfaces by connecting one of several conditioned sensor outputs to a shared amplifier or converter channel. The four SPST channels provide isolation without the source contention associated with permanently paralleled sensors, while 5 nA off leakage limits cross-channel interaction. Use the pin-description table to implement the intended normally closed behavior consistently, and provide local bypass capacitance on the supply pins. Keep sensitive sensor traces away from digital control routing to reduce capacitive feedthrough during switching.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho DG211CUE+ — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | DG211CUE+T | DG211CUA+ | DG211CUB+ | DG211CUC+ |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 16-TSSOP | 16-TSSOP | 16-TSSOP | 16-TSSOP | 16-TSSOP |
| Channel Configuration | 4 x SPST, normally closed | 4 x SPST, normally closed | 4 x SPST, normally closed | 4 x SPST, normally closed | 4 x SPST, normally closed |
| Maximum On-Resistance | 175 Ω | 175 Ω | 175 Ω | 175 Ω | 175 Ω |
| Minimum Dual Supply Voltage | ±4.5 V | ±4.5 V | ±4.5 V | ±4.5 V | ±4.5 V |
| Maximum Dual Supply Voltage | ±18 V | ±18 V | ±18 V | ±18 V | ±18 V |
| Turn-Off Time | 500 ns maximum | 500 ns maximum | 500 ns maximum | 500 ns maximum | 500 ns maximum |
| Switching Behavior | Break-before-make | Break-before-make | Break-before-make | Break-before-make | Break-before-make |
| Off Leakage | 5 nA | 5 nA | 5 nA | 5 nA | 5 nA |
Bảo phân biệt quan trọng
- Closest documented same-footprint procurement option (vsDG211CUE+T)
- Four independent normally closed routing paths in a compact package (vsADG201AKNZ)
- Defined transition behavior during path changes (vsDG211CJ+)
- Protection for power-down conditions with connected signals (vsDG211CSE)
Ghi chú thiết kế
Treat the DG211CUE+ as a resistance-bearing routing element rather than an ideal conductor. The maximum on-resistance is 175 Ω, so insertion loss increases when the switch drives a high-impedance node or a long downstream cable. Place the device close to the switched connector, minimize trace length, and keep the ground return adjacent to sensitive signal paths. If the source impedance is low, verify that the switch resistance does not upset gain, impedance matching, or noise calculations.
Do not assume that two normally closed channels may be connected together for an instant during a routing change. Break-before-make prevents an overlap at the internal switch, but it does not make the external system safe if control logic commands two independently driven sources onto the same node. Define valid control states in firmware or hardware so only one source is enabled. Check inactive input levels against the maximum signal range before applying a bipolar or single-ended waveform.
Use the 16-TSSOP land pattern from the manufacturer package drawing and verify pin assignments against the DG211 datasheet before routing. Place bypass capacitors close to the positive and negative supply pins, provide an uninterrupted ground connection, and separate control traces from switched analog nets. Because the switch is normally closed, floating control inputs may not guarantee a desired disconnected state; use defined logic levels and appropriate pull resistors where required by the system interface.
Operate the device only within its documented dual supply range of ±4.5 V to ±18 V and verify the absolute maximum ratings for signal overshoot, supply sequencing, and power-down conditions. The manufacturer guarantees latch-up protection when supplies are disconnected while connected inputs remain present, but this protection does not remove the need for clamping and current limiting at external connectors. Add protection networks where long cables or user-accessible fixtures can introduce transients.
Thông tin tuân thủ
The DG211 product page identifies the DG211 as a production device, but the retrieved documentation does not state the individual RoHS, REACH, halogen-free, or conflict-minerals status for this ordering designation. The DG211CUE+ is a commercial-temperature variant and is not identified as an automotive-qualified AEC-Q100 grade.