ICL7117CPL-3 - 3.5-Digit LED Display ADC | Analog Devices
MPN: ICL7117CPL-3 ✓ Hoạt độngICL7117CPL-3 Tóm tắt
An integrating analog-to-digital converter measures an unknown input voltage by integrating it over a fixed interval and comparing the result with a reference ramp. The dual-slope technique is particularly useful for panel meters, digital instruments, and process-control equipment because its accuracy and noise rejection are predictable, while the signal input draws very little current. The ICL7117 family differs from the ICL7106 by including a Hold input that can freeze a completed conversion.
Principal features include direct support for common-cathode LED displays, very high input impedance, true differential input operation, a 3.5-digit resolution format, and integrated seven-segment decoding. The display driver is intended for systems where a compact digital readout is required without a separate display controller. The operating-temperature range associated with the standard ICL7117CPL listing is 0°C to 70°C, while the exact temperature grade and production status of the ICL7117CPL-3 ordering code should be confirmed against the manufacturer ordering guide.
The ICL7117 uses a dual-slope conversion architecture rather than a successive-approximation or sigma-delta architecture. This architecture favors accuracy at relatively low conversion rates, rejects line-frequency and other periodic interference, and simplifies many meter designs. The device also includes the clock, reference, display decoder, and display-driver functions required for a complete digital panel meter.
Typical uses include laboratory and bench instruments, temperature-controller displays, process indicators, weighing equipment, environmental monitors, and industrial panel meters. In these applications, the ADC converts a scaled sensor or bridge output into a three-and-a-half-digit decimal value, while the integrated LED driver reduces the number of external display-interface components.
The most important PCB-design step is to follow the manufacturer’s pin-description and typical-application schematic when assigning the analog inputs, reference, clock, hold, and seven-segment outputs. Input and reference routing should be kept compact, with attention to leakage, grounding, and the decoupling requirements specified by Analog Devices.
This page organizes the technical characteristics, application guidance, package constraints, and documented comparison relationships for ICL7117CPL-3. It also identifies where a verified pin-to-pin replacement cannot be established without risking an invalid drop-in recommendation.
Bộ thay thế dễ dàng lắp đặt cho ICL7117CPL-3 — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Không có bộ thay thế dễ dàng lắp đặt sẵn có cho sản phẩm này.
Yêu cầu các bộ thay thếICL7117CPL-3 Tỷ lệ tối đa & tính chất điện
| ADC Type | Dual-slope integrating ADC |
| Display Resolution | 3.5 digits |
| Display Type | LED display |
| Number of ADC Channels | 1 channel |
| Input Configuration | True differential input |
| Reference Type | Internal reference |
| Display Decoder | Integrated seven-segment decoder |
| Display Driver | Direct LED display driver |
| Display Hold Function | Yes |
| Clock | Integrated clock |
| Khoảng nhiệt độ hoạt động | 0°C to 70°C |
| Hộp | 40-pin PDIP, 15.24 mm row spacing |
| Kiểu lắp đặt | Through hole |
| Conversion Principle | Dual-slope conversion |
Hướng dẫn cấu hình chân ICL7117CPL-3 40-pin pdip, 15.24 mm row spacing
Cấu hình chân cho ICL7117CPL-3 (40-pin pdip, 15.24 mm row spacing gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho ICL7117CPL-3.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
ICL7117CPL-3 phù hợp cho 6 Áp dụngs: Industrial Digital Panel Meter, Temperature Controller Readout, Laboratory Digital Instrument, Process Indicator, Weighing Scale Display, Environmental Monitoring Readout.
Industrial Digital Panel Meter
ICL7117CPL-3 fits a three-and-a-half-digit panel-meter design that must display a scaled sensor output without a separate display decoder. Its dual-slope integrating architecture and very high input impedance are useful when the signal source has limited drive capability, while the integrated seven-segment decoder and LED driver reduce the number of interface components. The device converts the input into a stable decimal reading and presents it through the connected common-cathode LED display. Because the package is a 40-pin PDIP, it is particularly practical for through-hole meter boards and legacy instrument platforms. The main design requirement is to follow the manufacturer’s typical application circuit for input filtering, reference connections, grounding, and the required clock and bypass components.
Được đề xuất
Temperature Controller Readout
ICL7117CPL-3 can serve as the measurement and display element in a temperature-control instrument that accepts a conditioned sensor signal. The very high input impedance minimizes loading of high-impedance sensors, and the dual-slope conversion method helps reject periodic interference found around heaters, relays, and switching equipment. A 3.5-digit resolution format is suitable for many temperature, setpoint, and process displays where one fractional digit improves readability. The integrated LED decoder and driver allow the controller to use a common-cathode seven-segment display directly. Layout should keep the analog input and reference paths compact and isolate them from display-current paths to preserve conversion stability.
Được đề xuất
Laboratory Digital Instrument
ICL7117CPL-3 is appropriate for a laboratory meter that combines measurement, conversion, and a three-digit-plus LED indication. Its integrated reference, clock, seven-segment decoder, and display driver reduce the number of external blocks required for a basic front panel. The integrating architecture is useful when the measurement bandwidth can be modest and rejection of periodic noise is more valuable than high conversion speed. The Hold function can freeze the displayed reading during a temporary reference or calibration step. Engineers should use the manufacturer’s recommended input, reference, clock, and bypass networks rather than substitute generic values because internal balance and conversion accuracy depend on the complete analog system.
Được đề xuất
Process Indicator
ICL7117CPL-3 is well matched to a process indicator that converts a scaled 4-to-20 mA, thermocouple-amplifier, or bridge output into a local LED reading. The ADC’s high input impedance prevents excessive loading of the upstream transducer conditioner, and the dual-slope technique provides predictable rejection of periodic industrial interference. The three-and-a-half-digit format is appropriate for many pressure, level, flow, and temperature indications. Because the device also drives the display directly, the PCB must separate sensitive input routing from LED return currents and use the grounding arrangement shown in the manufacturer application circuit.
Được đề xuất
Weighing Scale Display
ICL7117CPL-3 can form the core of a basic weighing-scale readout where a bridge or load-cell amplifier supplies a proportional analog voltage. The ADC’s high input impedance supports sensitive source circuits, while the dual-slope conversion architecture is well suited to the relatively slow measurement updates typical of a scale display. A 3.5-digit LED presentation can show weight, count, or test load with one fractional digit. The integrated display driver reduces control-board complexity, but the analog front end still requires careful grounding and shielding. Keep the bridge or amplifier output away from LED wiring, and implement zero and calibration functions around the manufacturer’s conversion timing and reference arrangement.
Được đề xuất
Environmental Monitoring Readout
ICL7117CPL-3 is useful in an environmental monitor that presents a locally generated LED value from a humidity, gas, or environmental sensing module. The three-and-a-half-digit format provides a compact numerical reading, while the integrated decoder and driver avoid a separate display-controller IC. The high input impedance helps preserve the accuracy of high-impedance sensor conditioners, and the dual-slope method suppresses periodic interference that can appear around fans and switching regulators. The device is appropriate for instrumentation rather than a high-rate waveform sampler. Confirm the operating temperature grade for the intended enclosure, minimize leakage around the input and reference nodes, and use the manufacturer’s recommended component values around the analog section.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho ICL7117CPL-3 — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này |
|---|---|
| Brand | Analog Devices |
| Package | 40-pin PDIP |
| ADC Type | Dual-slope integrating ADC |
| Display Resolution | 3.5 digits |
| Display Type | LED display |
| Number of ADC Channels | 1 channel |
| Display Hold | Yes |
| Reference | Internal reference |
| Clock | Integrated clock |
| Operating Temperature Range | 0°C to 70°C |
Ghi chú thiết kế
Route the analog input, reference, and ground connections according to the Analog Devices typical application schematic. The integrating ADC can be sensitive to leakage and ground gradients, so keep those nodes compact, avoid long paths beneath display-current wiring, and place their associated bypass components close to their specified device pins. Preserve the manufacturer’s ground topology rather than creating separate analog and digital returns that rejoin only at the power connector.
Do not treat every 40-pin ICL7106, ICL7116, or ICL7117 ordering code as interchangeable. ICL7117 provides LED drive and a Hold input, ICL7116 provides LCD drive and Hold, and ICL7106 is a related converter without the same hold arrangement. Verify each numbered terminal against the manufacturer data sheet, including the display-output functions, before using a related device as a replacement.
Keep the display-driver outputs and their return paths away from the high-impedance input and reference nodes. LED current can introduce ground disturbances that become visible in a meter reading, particularly when the seven-segment display draws different loads during multiplexing. Follow the manufacturer’s recommended PCB arrangement and provide the specified bypass capacitance at the supply pins. Confirm that the display current remains within the applicable output-drive limit.
Design the sensor and conditioning path for the ADC’s integrating measurement cycle rather than treating it as a high-speed sampling converter. Provide stable reference decoupling, adequate input filtering, and proper guarding around high-impedance sources. The dual-slope architecture naturally rejects periodic interference, but that benefit does not remove the need to suppress switching-node coupling and excessive ripple at the input or reference nodes.
Thông tin tuân thủ
Exact RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations for the ICL7117CPL-3 ordering code were not stated in the retrieved product listing. The ICL7117 family is presented as an Analog Devices production product, but compliance should be confirmed for the exact package and ordering code.