Analog Devices

LT1008CH - Picoamp Precision Operational Amplifier | Analog Devices

MPN: LT1008CH ✓ Hoạt động
Microvolt range Vdss Picoampere range Id TO-5, round, 8 leads, wire form Package
MOQ: 1 |

LT1008CH Tóm tắt

The Analog Devices LT1008CH is a single-circuit precision operational amplifier in an 8-lead round TO-5 hermetic package, combining picoampere input bias current, microvolt-level offset voltage, low noise, and very high common-mode and power-supply rejection. It operates from dual supplies up to ±18 V and can deliver 5 mA of load current, making it suitable for instrumentation, precision measurement, low-level signal conditioning, and current-to-voltage conversion.

An operational amplifier is a high-gain differential amplifier whose output responds to the voltage difference between its non-inverting and inverting inputs. Negative feedback causes the amplifier to amplify only the signal presented within its linear operating range while rejecting common-mode voltage and supply-noise variations. Within the broader hierarchy, the LT1008CH is an instrumentation amplifier, an operational amplifier, an analog amplifier, a semiconductor, and ultimately a linear integrated circuit.

The LT1008 family's defining characteristic is input bias current maintained in the picoampere range over the full -55°C to 125°C temperature range. This behavior makes the device useful with high-impedance sources, charge-sensitive transducers, leakage-sensitive sensors, and precision bridges where conventional CMOS or bipolar amplifiers may introduce unacceptable input-current error. The microvolt offset specification and low drift support stable DC measurements, while low voltage noise and current noise improve the useful resolution of small-signal chains.

Extremely high common-mode rejection ratio and power-supply rejection ratio allow the LT1008 to reject interference coupled from the input source or from imperfect power-supply rails. These characteristics matter in systems where the signal of interest is small but supply noise and ground offsets are much larger. The manufacturer describes the device as a universal precision operational amplifier suitable for practically all precision applications.

Typical uses include precision strain-gauge and bridge amplifiers, low-current pH and ion-selective measurement front ends, photodiode and charge-sensitive preamplifiers, laboratory references, low-leakage buffer stages, and precision current-to-voltage converters. The 8-lead TO-5 construction is mechanically robust and suited to laboratory, industrial, and instrumentation systems where through-hole mounting and hermetic construction are preferred.

When designing around the LT1008CH, account for input-bias-current error in the feedback network, provide adequate supply bypassing at the pins, and use guarding to minimize leakage on high-impedance nodes. Because the device can operate from ±18 V, verify the complete circuit's absolute maximum voltages and ensure input common-mode limits are respected during startup and fault conditions. This page consolidates manufacturer specifications, sourcing information, application guidance, and design notes that are not consolidated in a single distributor listing.

Bộ thay thế dễ dàng lắp đặt cho LT1008CH — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.

LT1008MH

✅ Drop-In
📦 TO-5, round, 8 leads
Same LT1008 precision-amplifier family and 8-lead TO-5 format; ordering suffix differs in temperature-grade and sourcing configuration, which must be confirmed before substitution

📋 Tham chiếu thay thế (không có trong danh mục)

LT1008CH Tỷ lệ tối đa & tính chất điện

Amplifier Type 1 Circuit
Product Category Standard (General Purpose) Amplifier
Architecture Single operational amplifier
Input Bias Current Picoampere range
Input Offset Voltage Microvolt range
Voltage Noise Low noise
Current Noise Low noise
Common-Mode Rejection Ratio Extremely high
Power Supply Rejection Ratio Extremely high
Output Current 5 mA load current
Maximum Supply Current 0.8 mA
Điện áp cung cấp ±18 V
Khoảng nhiệt độ hoạt động -55°C to 125°C
Bias Current Temperature Stability Picoampere bias current maintained over -55°C to 125°C
Package Type TO-5, round, 8 leads, wire form
Number of Terminals 8
Kiểu lắp đặt Through-hole

Hướng dẫn cấu hình chân LT1008CH to-5, round, 8 leads, wire form

Cấu hình chân cho LT1008CH (to-5, round, 8 leads, wire form gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.

Bảng cấu hình chân to-5, round, 8 leads, wire form cho LT1008CH

Không có dữ liệu chân cụ thể sẵn có cho LT1008CH.

Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.

Ứng dụng tiêu biểu

LT1008CH phù hợp cho 6 Áp dụngs: Precision Bridge and Strain-Gauge Amplification, Low-Current Sensor and pH Front End, Photodiode and Charge-Sensitive Preamplification, Precision Current-to-Voltage Conversion, Laboratory Reference and Buffer Stage, Industrial Process Instrumentation.

🏭

Precision Bridge and Strain-Gauge Amplification

The LT1008CH suits strain-gauge and resistive-bridge front ends because its picoampere input bias current produces minimal error in the high-value bridge and feedback networks. The microvolt-level offset and low drift also help preserve the small full-scale signal generated by mechanical strain. Place the amplifier in the bridge leg nearest the sensor, use matched high-precision resistors, and guard the input node against surface leakage. Compared with a general-purpose amplifier such as the LM324D, the LT1008CH better preserves DC accuracy when source impedance and bridge resistance are high. Its 5 mA output capability provides adequate drive for subsequent ADC front ends while keeping the overall system insensitive to supply and common-mode disturbances.

💊

Low-Current Sensor and pH Front End

The LT1008CH is well matched to pH electrodes, ion-selective electrodes, and other sensors whose useful output is measured in picoamperes or microvolts. Picoampere input bias current prevents the amplifier itself from generating an error comparable to the sensor current, while low voltage noise helps resolve small potential changes. Use guarding, clean connectors, and moisture control around high-impedance input nodes to avoid board leakage that can overwhelm the measurement. The LT1008CH's extremely high common-mode rejection is valuable when the sensor output is referenced to a noisy analog ground. Compared with the MC1458D, the LT1008CH is the better primary choice when picoampere bias-current stability is the dominant error term.

🔬

Photodiode and Charge-Sensitive Preamplification

The LT1008CH can serve as the first amplifier stage for photodiode, ion detector, or other charge-sensitive sensing because picoampere bias current minimizes disturbance of the sensing node. Low current noise and low voltage noise preserve resolution when the useful signal is smaller than the sensor leakage floor. Place the amplifier close to the detector, shield sensitive inputs, and maintain a guarded, low-leakage layout around the feedback components. The device's 5 mA output-current capability is adequate for driving a following filter stage over reasonable cable distances. Compared with the LM324D, whose bias current is substantially higher, the LT1008CH offers a clear advantage whenever input-current error defines the measurement limit.

⚡

Precision Current-to-Voltage Conversion

The LT1008CH is suitable for converting small currents into measurable voltages when bias-current and offset errors would otherwise obscure the result. Picoampere input bias current is especially valuable with currents in the picoampere-to-nanoampere range, while microvolt-level offset and low drift stabilize the zero point. Choose feedback resistors with tight tolerance and low voltage coefficients, and verify the amplifier's input-voltage and input-current limits against the expected operating range. Its extremely high power-supply rejection helps isolate the conversion stage from supply ripple. The MC1458D is a practical general-purpose alternative for less demanding conversions, but the LT1008CH is preferable when the input source approaches the picoampere range.

🔬

Laboratory Reference and Buffer Stage

The LT1008CH can buffer stable references, divider outputs, and laboratory sources where added noise, offset drift, or loading error would affect the measurement. Its low noise and high voltage gain allow it to maintain signal integrity behind higher-impedance downstream loads, while the 8-lead TO-5 package provides a mechanically robust through-hole solution for laboratory and industrial equipment. The 5 mA output capability is suitable for moderate loads, but the design should account for output-current limits and stability at the selected gain. Compared with the LM324D, the LT1008CH contributes less input bias current, offset voltage, and drift. The NE5534DR is a reasonable low-noise alternative when picoampere bias current is unnecessary and lower-noise audio-style performance is more important.

🏭

Industrial Process Instrumentation

The LT1008CH fits industrial process-measurement modules that combine a slow sensor signal with a relatively noisy 4-20 mA process environment. Picoampere input bias current reduces error at high-impedance sensor connections, and the extremely high common-mode rejection helps suppress ground-potential differences and coupling from adjacent machinery. Its TO-5 hermetic package and -55°C to 125°C bias-current stability are useful for rugged equipment. The 5 mA output rating supports moderate downstream loads, while ±18 V capability allows dual-rail implementation. The LM224DR can handle less sensitive auxiliary channels, but the LT1008CH should be selected for the input directly connected to the precision sensor. Grounding and guarding remain essential because the amplifier cannot compensate for contaminated or poorly insulated sensor wiring.

What are the key specifications of LT1008CH that engineers should know?
The LT1008CH is a single precision operational amplifier with picoampere input bias current, microvolt-level input offset voltage, low noise, extremely high common-mode rejection, and extremely high power-supply rejection. According to the Analog Devices LT1008 datasheet, bias current remains in the picoampere range from -55°C to 125°C. The device can deliver 5 mA of load current from supplies up to ±18 V and is packaged in an 8-lead round TO-5 package.
Where can I download the LT1008CH datasheet PDF?
The official LT1008CH datasheet PDF is available from Analog Devices at the LT1008 data-sheet URL provided on this page. The manufacturer document describes picoamp input current, microvolt offset, low noise, high common-mode rejection, high power-supply rejection, and operation from 5 mA output loading. The Analog Devices LT1008 product page is the appropriate starting point for revisions, package ordering information, and lifecycle updates.
What is the input bias current of the LT1008CH?
The LT1008CH operates with picoampere input bias current maintained over the full -55°C to 125°C temperature range. According to the Analog Devices LT1008 datasheet, this combination of picoampere bias current, microvolt offset voltage, and low noise distinguishes the device from general-purpose operational amplifiers. Picoampere bias current is particularly valuable when driving high-source-impedance sensors and guarding sensitive input nodes.
What supply voltage can the LT1008CH use?
The LT1008CH is suitable for operation from dual supplies up to ±18 V. A listing for this device explicitly identifies it for ±18 V applications, while the manufacturer material describes low power dissipation and universal precision-amplifier use. Designers should still consult the complete absolute-maximum and electrical-characteristics tables before choosing external clamping, filtering, or protection components.
What is the LT1008CH package and pin count?
The LT1008CH is supplied in an 8-lead, round TO-5 hermetic package with wire-form terminals for through-hole mounting. Distributor records identify the package code as TO-5 or BCY and confirm eight terminals. A package-specific terminal assignment was not included in the supplied web records, so this page does not publish an unverified pin-number map; use the Analog Devices datasheet for authoritative pin numbering.
What can replace an LT1008CH in an existing design?
The closest same-family candidate identified in the supplied cross-reference data is the LT1008MH, which shares the LT1008 precision-amplifier identity and is compared directly against LT1008CH. It should be treated as a family alternative whose temperature grade, availability, and exact orderable configuration must be checked before substitution. The supplied web evidence does not establish enough pin-compatible same-package alternatives to recommend five replacements with confidence.
Is the LT1008CH the same as the LT1008MH?
The LT1008CH and LT1008MH belong to the same Analog Devices LT1008 family, but they are not automatically identical orderable parts. Both provide the family's picoampere input bias current, microvolt offset, low noise, and high rejection characteristics. The relevant distinction is the specified grade and commercial availability of each suffix, which must be confirmed against the manufacturer data before treating one as an exact substitute.
When should I choose the LT1008CH instead of a general-purpose operational amplifier?
Choose the LT1008CH when picoampere input bias current and microvolt-level offset are more important than cost, size, or ease of sourcing. General-purpose amplifiers such as the LM324D or MC1458D are appropriate for many ordinary signal-conditioning tasks, but the LT1008CH better matches high-impedance sources, leakage-sensitive transducers, and precision bridge measurements. Its TO-5 hermetic construction is also favorable for rugged through-hole instrumentation.
Where can I buy LT1008CH online?
The LT1008CH is listed by DigiKey and other distributors in the supplied web results, and one distributor reports it in stock with fast delivery. XAIPART can also quote or order the component, but no verified unit-price schedule was supplied for this generation. Current price, stock, and lead time should therefore be confirmed at the distributor listing or through an XAIPART quotation request before releasing a purchase order.
What is the price of the LT1008CH?
A verified current unit price for the LT1008CH was not present in the supplied web records, so no numeric selling price can be stated reliably. The pricing fields on this page use zero as a non-orderable placeholder rather than presenting an invented price. Request an XAIPART quotation or check the DigiKey and Octopart listings for pricing and availability as of 2026-10-30 before budgeting the BOM.
What is the lead time for the LT1008CH?
The verified records indicate that DigiKey offered the LT1008CH for immediate shipment when the data was retrieved on 2026-10-30, while another distributor described stock and fast delivery. Exact lead time is inventory-dependent and can change quickly, especially for older hermetic analog devices. Confirm the current quantity and delivery schedule with the distributor or request an XAIPART quotation before committing the production build.
Is the LT1008CH in stock?
The supplied Digi-Key listing states that LT1008CH is in stock with fast delivery, and DigiKey's result also states that the part ships today. That statement was captured on 2026-10-30 and should not be treated as a permanent stock guarantee. For production planning, verify the live distributor inventory or request a firm XAIPART allocation and lead-time quotation.
LT1008CH vs LT1008MH: which is better for precision instrumentation?
The LT1008CH is the commercial-grade member identified in the supplied records, while the LT1008MH is the closely related military-style ordering option from the same family. For room-temperature commercial instrumentation, the LT1008CH is generally the natural selection if both are available; for extended-temperature or long-life programs, the grade and sourcing status of the selected suffix must drive the decision. Both remain in the LT1008 precision-amplifier family.
What is the best Analog Devices equivalent for the LT1008CH?
The LT1008MH is the best-supported Analog Devices family equivalent in the supplied cross-reference results because it is directly compared with LT1008CH and belongs to the same LT1008 precision-amplifier series. It is not necessarily an exact drop-in replacement for every ordering configuration. Confirm terminal assignment, temperature grade, availability, and all critical electrical limits against the current Analog Devices documentation before using it as a substitute.
How should the LT1008CH be used for high-impedance measurements?
Use the LT1008CH where source leakage and bias-current error would otherwise dominate the measurement. Its picoampere bias current minimizes error in high-value feedback resistors and high-impedance sensor interfaces. Guard the sensitive input node, keep contamination and humidity under control, and use low-leakage PCB materials. The low-noise characteristics then translate the small sensor current into a usable output voltage without excessive amplifier noise.

Dữ liệu tham khảo kỹ thuật cho LT1008CH — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.

Hướng dẫn chọn lựa

Choose the LT1008CH when the measured signal is small enough that input bias current, offset voltage, drift, and power-supply rejection materially affect accuracy. It is especially appropriate for high-impedance transducers, precision bridges, picoampere current measurements, and guarded laboratory inputs. Select the LT1008MH when the same LT1008 family is required for a different commercial or temperature-grade configuration, but verify the exact suffix specification and lifecycle status before substitution. Use the LM224DR or MC1458D for ordinary auxiliary channels where input current is not the limiting error term, and use the NE5534DR when low-noise audio-style amplification matters more than picoampere input bias current. The TO-5 format favors rugged through-hole instrumentation but requires more board area than modern surface-mount precision amplifiers. Guarding, leakage control, clean PCB assembly, and correct supply bypassing remain essential regardless of which amplifier is selected.

So sánh với các sản phẩm thay thế

Tham số Sản phẩm này LT1008MH
Brand Analog Devices Analog Devices
Package TO-5, round, 8 leads TO-5, round, 8 leads
Amplifier Type 1 Circuit 1 Circuit
Product Category Standard (General Purpose) Amplifier Standard precision operational amplifier
Input Bias Current Picoampere range Picoampere range
Input Offset Voltage Microvolt range Microvolt range
Common-Mode Rejection Ratio Extremely high Extremely high
Power Supply Rejection Ratio Extremely high Extremely high
Output Current Capability 5 mA 5 mA
Supply Voltage ±18 V ±18 V
Temperature Range -55°C to 125°C Military-grade suffix configuration; confirm exact rating

Bảo phân biệt quan trọng

  • Picoampere-class input bias current supports very high source impedances (vsLM324D)
  • Microvolt-level offset supports precision DC measurement (vsMC1458D)
  • Hermetic 8-lead TO-5 construction for precision instrumentation (vsTLV1504ID)

Ghi chú thiết kế

The most common error is selecting a general-purpose amplifier for a high-impedance source. The LT1008CH is justified when input bias current is comparable to the signal current; use it for picoampere-level sources, not merely to obtain a conventional low-noise amplifier. Keep high-value feedback resistors away from contaminated board surfaces, use guarding around sensitive inputs, and verify that connector leakage, solder-flux residue, and humidity do not exceed the available measurement current.

Although the LT1008CH is a through-lead TO-5 device, layout quality still affects precision performance. Place input and feedback components close to pins 1-8 as identified in the official datasheet, keep input traces short, and provide a quiet analog ground path. Avoid routing high-current or switching-node copper beneath the input and feedback network. Use a grounded guard trace around the most sensitive input node to suppress surface leakage.

Bypass the power-supply pins with short, low-inductance ceramic capacitors placed adjacent to the device, and avoid long traces between the amplifier and bypass components. The verified records identify ±18 V operation and 5 mA output-load capability, but designers must check the official absolute-maximum table before applying rail transients. Provide controlled power sequencing so that input and output voltages do not exceed the specified common-mode and supply limits during startup.

Thông tin tuân thủ

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Không chì
Unknown
Không halogen
Unknown
Khoáng vật xung đột
Unknown

The supplied verified records identify the LT1008CH as a general-purpose precision amplifier in an 8-lead TO-5 package but do not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. No compliance declaration was inferred.

Tìm kiếm liên quan

LT1008CH LT1008CH datasheet PDF Analog Devices LT1008CH LT1008CH TO-5 precision op amp picoamp input current precision operational amplifier LT1008CH microvolt offset low noise amplifier LT1008CH high impedance sensor front end LT1008CH strain gauge bridge amplifier LT1008CH vs LT1008MH LT1008CH drop-in replacement buy LT1008CH online LT1008CH price and lead time where to find LT1008CH pinout what can replace LT1008CH

Các bộ phận và thuật ngữ liên quan

Analog Devices LT1008 LT1008CH LT1008MH precision operational amplifier instrumentation amplifier analog amplifier linear integrated circuit semiconductor picoampere input bias current microvolt input offset voltage common-mode rejection ratio power-supply rejection ratio low voltage noise low current noise TO-5 package 8-lead hermetic package through-hole mounting surface leakage guarding strain-gauge bridge pH electrode photodiode preamplifier current-to-voltage converter industrial process instrumentation
Báo giá nhanh RFQ
Hãy điền đầy đủ thông tin — đội ngũ bán hàng của chúng tôi sẽ phản hồi trong vòng 24 giờ
Mã sản phẩm Nhà sản xuất Kiểu đóng gói QTY Giá mục tiêu Phụ
✓
Báo giá đã gửi!

Chúng tôi sẽ trả lời email của bạn trong vòng 24 giờ

1
RFQ đã gửi
2
Phiếu báo giá nhận được
3
Đặt hàng thành công
4
Thanh toán
5
Đã gửi
6
Đã giao hàng
Xem chi tiết RFQ