MK2308G-1HILF - 133MHz Zero Delay Buffer | Renesas
MPN: MK2308G-1HILF ✓ Hoạt độngMK2308G-1HILF Tóm tắt
A zero-delay buffer is a clock-integrity IC that uses an internal phase-locked loop to reproduce a clock while compensating for propagation delay through external routing. Its function hierarchy is zero-delay buffer, clock buffer, clock and timing IC, logic IC, and integrated circuit. Unlike a passive delay line, this device actively reconstructs its output clock, helping downstream circuits receive low-skew timing signals.
The MK2308G-1HILF provides a 1:8 input-to-output ratio, CMOS output compatibility, and PLL bypass functionality. The bypass path is useful when the system does not require PLL-based phase adjustment. Its 133 MHz maximum frequency makes it suitable for clock distribution in communication, industrial control, computing, and test-and-measurement systems that operate below that frequency.
Renesas describes the device as a 3.3 V low-skew clock buffer. The PLL architecture separates clock generation from input distribution, allowing the device to maintain controlled output timing when system traces and device delays would otherwise create skew between destinations. The 16-TSSOP package provides a compact surface-mount format compatible with standard PCB assembly processes.
Typical applications include network-interface clock distribution, processor and peripheral clock routing, industrial control systems, communications equipment, and instrumentation. In these systems, the buffer can fan out one reference clock to multiple destinations while reducing the timing uncertainty introduced by unequal trace lengths.
The primary design consideration is confirming that the intended input frequency, output-divider configuration, bypass state, and output loading remain within the manufacturer’s operating limits. PCB layout should minimize clock-trace mismatch and return clock and power grounds cleanly. Decoupling capacitors should be placed close to the supply pins according to the manufacturer’s recommended layout.
This page consolidates the device’s key electrical characteristics, verified package information, a confirmed same-family replacement, practical clock-layout guidance, and an eight-parameter engineering comparison. It is designed to help engineers assess fit, replacement risk, and board-level implementation before committing to a design.
Bộ thay thế dễ dàng lắp đặt cho MK2308G-1HILF — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với MK2308G-1HILF (cùng hình factor và footprint) — khác nhau ở Number of Circuits, Package.
MK2308G-1HI
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →MK2308G-1HILF Thông số kỹ thuật
| Product Type | Zero Delay Buffer |
| Điện áp cung cấp | 3.3 V |
| Maximum Frequency | 133 MHz |
| Number of Circuits | 1 |
| Input-to-Output Ratio | 1:8 |
| PLL Function | Yes with bypass mode |
| Input Signal Type | Clock |
| Output Signal Type | CMOS |
| Hộp | 16-TSSOP (0.173 inch, 4.40 mm width) |
| Number of Terminals | 16 |
| Terminal Form | Gull wing |
| Package Shape | Rectangular |
| Temperature Grade | Industrial |
| Kiểu lắp đặt | Surface mount |
Hướng dẫn cấu hình chân MK2308G-1HILF rectangular
Cấu hình chân cho MK2308G-1HILF (rectangular gói). Số thứ tự chân, chức năng và sơ đồ kết nối được xác định trong tài liệu thông số kỹ thuật của nhà sản xuất. Tham khảo nó để biết footprint và hướng dẫn hàn chính xác.
Không có dữ liệu chân cụ thể sẵn có cho MK2308G-1HILF.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
MK2308G-1HILF phù hợp cho 6 Áp dụngs: Network Interface Clock Distribution, Processor Peripheral Clock Routing, Industrial Control Systems, Test and Measurement Instrumentation, Communications Equipment, Low-Skew Fan-Out.
Network Interface Clock Distribution
The MK2308G-1HILF fits network-interface clock distribution because its 133 MHz maximum frequency covers many low- and mid-speed serial, parallel, and processor interface clocks. The single clock circuit and 1:8 input-to-output ratio allow a reference clock to be divided before distribution, while PLL-based compensation can reduce timing variation introduced by unequal PCB routes. In a communications board, the IC can sit after the main clock source and feed multiple endpoint loads. The design tradeoff is that each destination must be evaluated for allowable loading and timing margin, while bypass mode can simplify operation when phase correction is unnecessary.
Được đề xuất
Processor Peripheral Clock Routing
The MK2308G-1HILF is suitable for distributing a shared clock to processor, memory, and peripheral loads when the operating frequency remains at or below 133 MHz. Its PLL-based zero-delay architecture compensates for clock-path delay while preserving a defined relationship between input and output timing. The 16-TSSOP package allows placement near the load cluster, reducing long clock traces. Designers should compare trace lengths, account for output loading, and choose PLL or bypass operation according to the reference clock’s stability and the receiving devices’ timing requirements.
Được đề xuất
Industrial Control Systems
The MK2308G-1HILF can support clock distribution in industrial control systems that require deterministic fan-out from a common reference. Its 3.3 V CMOS-compatible architecture, PLL bypass capability, and 133 MHz frequency ceiling fit control boards that operate below the maximum rate and need multiple coordinated clock domains. Place the device where trace lengths to the receiving logic are balanced, and validate operation over the complete industrial temperature range and supply tolerance. The primary tradeoff is dependence on reference-clock quality when PLL mode is active, so bypass mode is useful when the source is already sufficiently clean.
Được đề xuất
Test and Measurement Instrumentation
The MK2308G-1HILF can distribute clock signals inside instrumentation where several converters, counters, and processors need a common timing reference. At frequencies up to 133 MHz, its active clock reconstruction can help reduce skew caused by variable routing delay, while the 1:8 ratio supports applications requiring a divided clock. The TSSOP package fits compact instrument electronics, but measurement accuracy still depends on output jitter, skew, and loading specifications. Bench prototypes should characterize the intended cable, divider, and receiver loads and compare PLL mode against bypass mode for sensitivity to source noise.
Được đề xuất
Communications Equipment
The MK2308G-1HILF is applicable to communications equipment requiring one input clock to feed several logic blocks through a defined ratio. Its 133 MHz maximum frequency supports common control and interface clock rates, and the PLL bypass function gives designers a path for systems that prefer direct clocking. In a line-card or communication module, short output traces and symmetric routing are essential for maintaining timing margin. Check every output’s capacitive loading and ensure the selected configuration meets the maximum operating frequency before production release.
Được đề xuất
Low-Skew Fan-Out
The MK2308G-1HILF is designed for low-skew fan-out when multiple endpoints cannot be driven reliably from a source with unbalanced routing. A 1:8 ratio and PLL-based clock path provide a practical way to generate coordinated outputs from one input clock at frequencies up to 133 MHz. Layout should keep output routes length-matched where practical, use a solid ground reference, and place decoupling close to the device. PLL mode offers active timing compensation, while bypass mode reduces dependence on loop lock but may be more sensitive to input-clock quality and board delay.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho MK2308G-1HILF — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | MK2308G-1HI |
|---|---|---|
| Brand | Renesas Electronics | Renesas Electronics |
| Package | 16-TSSOP | 16-TSSOP |
| Product Type | Zero Delay Buffer | Zero Delay Buffer |
| Maximum Frequency | 133 MHz | 133 MHz |
| Number of Circuits | 1 | 1 |
| Input-to-Output Ratio | 1:8 | 1:8 |
| PLL Function | Yes with bypass mode | Yes with bypass mode |
| Output Type | CMOS | CMOS |
Bảo phân biệt quan trọng
- Confirmed same-package replacement (vsMK2308G-1HI)
- PLL-based timing compensation (vsMK2308G-1HI)
- Single-circuit 1:8 clocking (vsMK2308G-1HI)
Ghi chú thiết kế
Route the input and all enabled outputs as short, direct clock traces, and match output path lengths where the receiving circuitry depends on low skew. Avoid routing the clock across plane splits or noisy switching regions. Place the MK2308G-1HILF near the clock-load cluster so that its active compensation can correct predictable board delay without creating long downstream branches. The manufacturer datasheet pinout and recommended layout should define the final connection and return-path arrangement.
Follow the Renesas datasheet connection and decoupling guidance for the 3.3 V supply. Place the required bypass capacitor adjacent to the supply and ground pins, keep its current loop compact, and provide a low-impedance ground reference beneath the device. Check the supply voltage at the IC under worst-case source impedance and load transient. Supply disturbance can appear directly as clock instability, especially when PLL mode is selected instead of bypass mode.
Do not infer that every 16-TSSOP clock buffer is interchangeable with the MK2308G-1HILF. Confirm the 3.3 V supply, 133 MHz operating limit, 1:8 ratio, CMOS output behavior, PLL and bypass functions, and pin assignments in the manufacturer datasheet. The confirmed MK2308G-1HI replacement preserves these functions and the same package, but unrelated clock-driver families may use different divider ratios, enable logic, or output-count arrangements.
Thông tin tuân thủ
The product is identified as an industrial-grade clock buffer. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status are not stated in the cited product information; AEC-Q100 is not applicable because the device is not identified as an automotive-qualified part.