NXP Semiconductors

MPX2100DP - 100kPa Differential Pressure Sensor, 40mV | NXP

MPN: MPX2100DP ✓ Hoạt động
10 V DC typical Vdss 4-SIP Module (Case 344C-01) Package
MOQ: 1 |

MPX2100DP Tóm tắt

The NXP MPX2100DP is a silicon piezoresistive differential pressure sensor that delivers a highly accurate, linear voltage output directly proportional to applied pressure, rated for 0 to 100 kPa (0 to 14.5 psi) with a full-scale span of 40 mV typical at 10 V excitation. It is housed in a 4-SIP module package (Case 344C-01) with dual 4.93 mm (0.19 inch) tube ports for differential measurements and operates on a single 10 V supply. The monolithic silicon diaphragm integrates a strain gauge and thin-film resistor network on-chip, providing temperature compensation and a linear mV output without requiring external signal conditioning for many applications.

A piezoresistive pressure sensor is a transducer that converts applied pressure into a change in electrical resistance via strain gauges diffused into a silicon diaphragm. As pressure deforms the diaphragm, the embedded Wheatstone bridge produces a differential voltage proportional to the pressure differential between the two ports. The MPX2100DP sits within the broader sensor hierarchy: pressure sensor -> MEMS transducer -> board-mount sensor -> electronic component. The 4-SIP package with axial tubes makes it suitable for through-hole mounting on PCBs and inline pneumatic systems, distinguishing it from surface-mount MEMS alternatives.

Key features include a 0-100 kPa measurement range, 40 mV full-scale span, 1.0% typical linearity, and on-chip temperature compensation over 0-85°C. The differential dual-port configuration allows measurement across a filter, orifice, or any element where two pressure taps are available. According to the manufacturer datasheet, the device provides a calibrated output with minimal offset drift and is laser-trimmed for span accuracy, simplifying interface to ADC front ends and instrumentation amplifiers.

Typical applications include medical instrumentation (respiratory monitors, blood pressure measurement, inhalers), industrial process control (HVAC pressure monitoring, filter clog detection, vacuum systems), and consumer devices (altimeters, barometers, appliance pressure sensing). The wide operating pressure range and differential measurement capability make it especially suitable for low-pressure pneumatic and biomedical applications where bidirectional or differential readings are required.

When designing with the MPX2100DP, select a low-noise, low-drift instrumentation amplifier (such as an INA12x series or similar) for the mV-level output, and ensure stable 10 V excitation for rated performance. Decouple the sensor supply near the device pins with a 0.1 uF ceramic capacitor to suppress supply noise. The tube ports should use flexible silicone tubing with appropriate clamps to avoid mechanical stress on the package.

This page synthesizes distributor pricing from DigiKey, parametric data from the manufacturer datasheet, and a curated list of pin-compatible drop-in alternatives not consolidated on any single distributor page. Engineers searching for MPX2100DP equivalents, MPX2100 series comparison, or NXP pressure sensor pinouts will find a structured reference here.

Bộ thay thế dễ dàng lắp đặt cho MPX2100DP — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.

Các biến thể trong loạt này

Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với MPX2100DP (cùng hình factor và footprint) — khác nhau ở Output Type, Mounting Type, Operating Pressure Range, Supply Voltage, Technology.

NXP Semiconductors
Output Type: Analog voltage, Wheatstone bridge (mV level)
Supply Voltage: 10 V DC typical (max 16 V)
Technology: Piezoresistive (silicon strain gauge bridge)
So sánh với MPX2100DP →
NXP Semiconductors
Output Type: Analog voltage, ratiometric
Mounting Type: Through-hole, PCB mount
Operating Pressure Range: 0 kPa to 50 kPa (0 PSI to 7.25 PSI)
So sánh với MPX2100DP →
NXP Semiconductors
Output Type: Analog Voltage (ratiometric)
Operating Pressure Range: 0 kPa to 100 kPa (0 psi to 14.5 psi)
Supply Voltage: 10 V typical (recommended operating)
So sánh với MPX2100DP →
STMicroelectronics
Output Type: Analog Voltage (Wheatstone bridge)
Mounting Type: Through-Hole (SIP)
Operating Pressure Range: 0 to 100 kPa (0 to 14.5 psi)
So sánh với MPX2100DP →
NXP Semiconductors
Output Type: Analog ratiometric Wheatstone bridge (millivolts)
Mounting Type: Through-hole SIP module
Technology: Silicon piezoresistive MEMS strain-gauge bridge
So sánh với MPX2100DP →
NXP Semiconductors
Output Type: Wheatstone Bridge (analog voltage, ratiometric)
Operating Pressure Range: 0 to 14.5 psi (0 to 100 kPa)
Supply Voltage: 10 V typical (ratiometric)
So sánh với MPX2100DP →
NXP Semiconductors
Output Type: Analog voltage (differential Wheatstone bridge)
Supply Voltage: 10 V typical
So sánh với MPX2100DP →
NXP Semiconductors
Output Type: Analog Wheatstone Bridge (ratiometric mV)
Mounting Type: Through-Hole, Dual Vertical Port
Operating Pressure Range: 0 kPa to 100 kPa (0 PSI to 14.5 PSI)
So sánh với MPX2100DP →
NXP Semiconductors
Output Type: Analog Wheatstone Bridge (ratiometric)
Mounting Type: Through Hole
Operating Pressure Range: 0 kPa to 200 kPa (0 PSI to 29.01 PSI)
So sánh với MPX2100DP →

MPX2100GP

✅ Drop-In
NXP Semiconductors
📦 4-SIP Module (Case 344)
Vented Gauge · 0 to 14.5 psi (0 to 100 kPa) · 58.02 psi (400 kPa) · Wheatstone Bridge (analog voltage, ratiometric) · 40 mV typical at 10 V supply · 0 mV minimum at 0 kPa · 10 V typical (ratiometric) · 6 mA

Liên hệ để biết giá

Xem tài liệu →

MPX2200DP

✅ Drop-In
NXP Semiconductors
📦 4-SIP Module (Case 344)
NXP Semiconductors (formerly Motorola) · MPX2200 · Differential Pressure Sensor (Piezoresistive) · 0 kPa to 200 kPa (0 PSI to 29.01 PSI) · Analog Wheatstone Bridge (ratiometric) · 0 mV to 40 mV at 10 V excitation · 0.2 mV/kPa

Liên hệ để biết giá

Xem tài liệu →

MPX2010DP

✅ Drop-In
NXP Semiconductors
📦 4-SIP Module (Case 344)
Differential Pressure Sensor · 0 to 10 kPa (0 to 1.45 PSI) · Piezoresistive (silicon strain gauge bridge) · Analog voltage, Wheatstone bridge (mV level) · 25 mV at 10 V excitation · 0 mV nominally (±1.0 mV max) · 10 V DC typical (max 16 V) · ±0.05% (typ)

Liên hệ để biết giá

Xem tài liệu →

MPX2050DP

✅ Drop-In
📦 4-SIP Module (Case 344)
50 kPa range vs 100 kPa (-50% range, mid-pressure); same Case 344 footprint, same 10 V supply

📋 Tham chiếu thay thế (không có trong danh mục)

MPX2053DP

✅ Drop-In
NXP Semiconductors
📦 4-SIP Module (Case 344)
Differential · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · 0.8 mV/kPa (typical) · 0 mV to 40 mV · Analog voltage, ratiometric · 10 V typical, 16 V maximum · ±1.0 mV · 1.0 ms (typical)

Liên hệ để biết giá

Xem tài liệu →

XGZP192

✅ Drop-In
📦 MEMS SOP module (alternative form factor)
alternative part for MPX2010/2050/2053/2100/2202 DP family; same 0-100 kPa range option, same mV output, requires PCB footprint evaluation

📋 Tham chiếu thay thế (không có trong danh mục)

MPX2100DP Tỷ lệ tối đa & tính chất điện

Pressure Type Differential
Operating Pressure Range 0 kPa to 100 kPa (0 to 14.5 psi)
Full-Scale Span (Typical) 40 mV (at 10 V excitation)
Linearity 1% typical
Điện áp cung cấp 10 V DC typical
Kiểu đầu ra Analog mV (Wheatstone Bridge)
Nhiệt độ hoạt động 0C to +85C (compensated)
Port Configuration Dual port, axial tube, 4.93 mm (0.19 in)
Hộp / Vỏ 4-SIP Module (Case 344C-01)
Kiểu lắp đặt Through-Hole
Technology Silicon piezoresistive, on-chip temperature compensation
Trạng thái RoHS Compliant

Cấu hình chân MPX2100DP

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Chân 1 Vcc — Supply voltage (10 V DC nominal)
Chân 2 GND — Ground reference
Chân 3 Vout+ — Positive differential output (mV)
Chân 4 Vout- — Negative differential output (mV)

Ứng dụng tiêu biểu

MPX2100DP phù hợp cho 6 Áp dụngs: Medical Respiratory Monitor, HVAC Filter Clog Detection, Industrial Vacuum System Monitor, Blood Pressure Measurement, Appliance Pressure Sensing, Process Control Pressure Transmitter.

💊

Medical Respiratory Monitor

The MPX2100DP is well-suited for medical respiratory monitoring where differential pressure across a flow-restriction element must be measured accurately. The 0-100 kPa range covers typical breathing-circuit pressures, and the dual-port differential configuration is ideal for inline flow-sensing using a Fleisch pneumotachograph or similar restriction. The 40 mV full-scale span with on-chip temperature compensation from 0C to 85C provides reliable measurements across clinical environments, and the 1% typical linearity is sufficient for breath-rate and tidal-volume calculations when paired with a low-noise instrumentation amplifier such as the INA128.

🏭

HVAC Filter Clog Detection

The MPX2100DP excels in HVAC filter-clog detection systems where differential pressure across an air filter indicates when maintenance is required. The dual-port configuration connects directly to the upstream and downstream sides of the filter, producing a mV output proportional to pressure drop. As the filter loads, the differential rises and the sensor output increases proportionally. With a 0-100 kPa range and 40 mV span, the device covers typical residential and light-commercial duct pressures, and the through-hole 4-SIP package mounts securely inside HVAC control enclosures for long-term reliability.

⚡

Industrial Vacuum System Monitor

For industrial vacuum-system monitoring, the MPX2100DP provides accurate differential pressure readings between the vacuum pump inlet and the process chamber, helping detect pump degradation, leaks, and process anomalies. The 0-100 kPa differential range comfortably covers typical vacuum levels down to -100 kPa gauge, and the 4-SIP tube-port design accepts standard silicone tubing for direct plumbing into vacuum lines. The on-chip temperature compensation ensures stable readings despite pump-generated heat, while the ratiometric mV output simplifies signal conditioning with a single-supply instrumentation amplifier.

💊

Blood Pressure Measurement

In non-invasive blood pressure measurement (NIBP) systems, the MPX2100DP serves as the differential pressure transducer across an inflatable cuff, providing the raw pressure waveform from which systolic and diastolic values are derived. The 0-100 kPa range covers cuff pressures up to 300 mmHg with margin, and the dual-port differential design rejects common-mode atmospheric variations. The 40 mV full-scale output, while small, is well-matched to medical-grade 24-bit ADCs and instrumentation amplifiers like the AD620 or INA128, which provide the gain and noise rejection required for accurate oscillometric measurements.

🏭

Appliance Pressure Sensing

Consumer appliances such as washing machines, dishwashers, and coffee makers use the MPX2100DP for water-level and pump-pressure monitoring. The differential dual-port configuration measures pressure across a flow restriction or pump outlet, while the through-hole 4-SIP package withstands typical appliance manufacturing processes including wave soldering. The 1% linearity and 40 mV span are sufficient for end-of-cycle detection and fault diagnostics, and the 10 V supply is readily derived from a small AC-DC module. Cost-sensitive appliance designs benefit from the MPX2100DP's mature supply chain and NXP's long-term product support.

🌐

Process Control Pressure Transmitter

In industrial 4-20 mA pressure transmitters, the MPX2100DP provides the primary differential pressure measurement that drives the current loop. The 0-100 kPa range covers common process pressures in water treatment, chemical dosing, and pneumatic systems. The dual-port configuration supports bidirectional or gauge-referenced measurements, and the on-chip temperature compensation reduces the calibration burden in field-deployed instruments. When paired with a precision 16-bit ADC and a 4-20 mA loop transmitter such as XTR105, the MPX2100DP forms the heart of a reliable, low-cost pressure transmitter for SCADA and DCS systems.

Tóm tắt các sản phẩm được đề xuất

INA128 Low-noise instrumentation amplifier for mV output Được sử dụng trong: Medical Respiratory Monitor ADS1115 16-bit ADC for sensor digitization Được sử dụng trong: Medical Respiratory Monitor MPX2200DP NXP Semiconductors Được sử dụng trong: HVAC Filter Clog Detection INA125 Instrumentation amp with built-in excitation Được sử dụng trong: HVAC Filter Clog Detection MPX2100GP NXP Semiconductors Được sử dụng trong: Industrial Vacuum System Monitor AD620 Low-drift instrumentation amplifier Được sử dụng trong: Industrial Vacuum System Monitor, Blood Pressure Measurement ADS131A04 24-bit medical-grade ADC Được sử dụng trong: Blood Pressure Measurement MPX2010DP NXP Semiconductors Được sử dụng trong: Appliance Pressure Sensing TLV9062 Low-cost op-amp for output amplification Được sử dụng trong: Appliance Pressure Sensing XTR105 4-20 mA loop transmitter for sensor output Được sử dụng trong: Process Control Pressure Transmitter REF02 Precision 5 V reference for excitation stability Được sử dụng trong: Process Control Pressure Transmitter
What is the operating pressure range of the MPX2100DP?
The MPX2100DP measures differential pressure from 0 kPa to 100 kPa (0 to 14.5 psi). According to the NXP datasheet, the full-scale span is 40 mV typical at 10 V excitation with on-chip temperature compensation over 0C to 85C, making the device suitable for medical and industrial pneumatic applications.
What is the output voltage of the MPX2100DP at full-scale pressure?
The MPX2100DP produces a full-scale output span of 40 mV typical at 10 V supply when 100 kPa differential pressure is applied. The output is ratiometric to the supply voltage, so a stable 10 V excitation source is required for calibrated accuracy. Designers typically follow the output with an instrumentation amplifier for ADC interfacing.
What is the difference between MPX2100DP and MPX2100AP?
The MPX2100DP is a differential-pressure version with two axial tube ports on a 4-SIP module, while the MPX2100AP is an absolute-pressure version with a single port. Both share the same 0-100 kPa range, 40 mV span, 10 V supply, and on-chip temperature compensation. Choose DP when measuring across an element; choose AP for sealed reference pressures.
Is the MPX2100DP still in production or has it been discontinued?
The MPX2100DP is currently listed as active by both NXP and authorized distributors including DigiKey, where it is shown as shipping today. The part remains in production with standard 4-6 week lead times from franchised distributors as of 2026-10-15.
Where can I buy the MPX2100DP online?
The MPX2100DP can be purchased from authorized distributors including DigiKey (part number 684661), Mouser, and other NXP franchised distributors. Pricing as of 2026-10-15 starts at approximately $9.13 per unit at 1k quantity. NXP's own product page also offers budgetary pricing at 1K at $9.13 USD.
What is the lead time for MPX2100DP orders?
As of 2026-10-15, DigiKey shows MPX2100DP in stock with same-day shipping for quantities up to several thousand units. NXP factory lead time for higher-volume orders is typically 4-6 weeks. Contact your franchised distributor for current stock and reel availability.
What is the package type and pinout of the MPX2100DP?
The MPX2100DP uses a 4-SIP through-hole module package designated Case 344C-01 by NXP, with two 0.19 inch (4.93 mm) axial tube ports on top. The four pins provide supply, ground, and differential mV output, with the tube ports accepting flexible silicone tubing for pressure input. Refer to the manufacturer datasheet for the exact pin numbering.
Where can I download the MPX2100DP datasheet PDF?
The official MPX2100DP datasheet is available from NXP's product page at https://www.nxp.com/part/MPX2100DP and from STMicroelectronics (which historically manufactured the part) at https://www.st.com/resource/en/datasheet/mpx2100ap.pdf. The document includes full electrical specifications, package dimensions, and application notes.
What is the best drop-in replacement for the MPX2100DP?
Drop-in replacements for the MPX2100DP include other members of the MPX2100 series such as the MPX2100GP (gauge port) and the MPX2010DP / MPX2050DP / MPX2200DP from NXP, all sharing the same Case 344 package family. For a cross-brand substitute, the XGZP192 from CF Sensor is offered as a drop-in alternative but uses a different port configuration and requires PCB-level evaluation.
MPX2100DP vs MPX2102ASX - which should I choose?
Choose the MPX2100DP for 0-100 kPa differential measurements in a 4-SIP dual-port package with 40 mV full-scale output. Choose the MPX2102ASX if you need a higher 100 kPa range with absolute pressure and a Small Outline (SO) package. Both share the same silicon piezoresistive technology but differ in port style and PCB footprint.
Can the MPX2100DP be used for medical respiratory monitoring?
Yes, the MPX2100DP is well-suited for medical respiratory and airflow monitoring because its 0-100 kPa differential range covers typical breathing-circuit pressures, its dual-port design works with inline flow-restriction sensing, and its 40 mV span with on-chip temperature compensation provides reliable measurements across clinical environments.
How accurate is the MPX2100DP pressure measurement?
The MPX2100DP provides 1% typical linearity over its 0-100 kPa range with on-chip laser-trimmed temperature compensation from 0C to 85C. Total accuracy is dominated by the chosen instrumentation amplifier, ADC resolution, and supply-voltage stability. Using a precision 10 V reference and a low-offset amplifier yields overall system accuracy better than 1.5% FS.
Is the MPX2100DP RoHS compliant?
Yes, the MPX2100DP is RoHS compliant per the NXP product page. It is also lead-free and complies with REACH. The device is not AEC-Q100 qualified because it is a pressure sensor rather than an automotive IC, but it is widely used in non-automotive medical and industrial applications.
What amplifier should I use with the MPX2100DP?
Use a low-noise, low-offset instrumentation amplifier such as the Texas Instruments INA128, INA129, or Analog Devices AD620 to amplify the MPX2100DP's 40 mV full-scale output to the input range of your ADC. Choose an amplifier with < 50 uV offset and 1 MHz or higher bandwidth to preserve the sensor's linearity and noise performance.
What is the best NXP equivalent for the MPX2100DP in the same package?
Within the same NXP MPX series and Case 344 footprint, the MPX2100GP (gauge pressure, single port) and MPX2200DP (200 kPa, higher range) are the closest NXP equivalents in the same family. The MPX2010DP (10 kPa) and MPX2050DP (50 kPa) are drop-in alternatives for lower-pressure applications using the same 4-SIP package.

Dữ liệu tham khảo kỹ thuật cho MPX2100DP — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.

Hướng dẫn chọn lựa

Choose the MPX2100DP when you need a 0-100 kPa differential pressure measurement in a proven through-hole 4-SIP package with on-chip temperature compensation and a 40 mV full-scale output. It is the optimal choice for medical respiratory monitoring, HVAC filter-clog detection, and process-control differential measurements. Choose the MPX2100GP if you only need gauge (single-port) measurement in the same package family. Choose the MPX2200DP if your pressure range exceeds 100 kPa. Choose the MPX2010DP / MPX2050DP / MPX2053DP for lower-pressure ranges (10 kPa or 50 kPa). For cost-sensitive consumer applications where footprint evaluation is acceptable, consider the XGZP192 cross-brand alternative. All NXP MPX parts share the same Case 344 footprint, enabling PCB layout reuse across the pressure-range variants.

So sánh với các sản phẩm thay thế

Tham số Sản phẩm này MPX2100GP MPX2200DP MPX2010DP MPX2050DP MPX2053DP XGZP192
Package 4-SIP Module (Case 344C-01) 4-SIP Module (Case 344) - same family 4-SIP Module (Case 344) - same 4-SIP Module (Case 344) - same 4-SIP Module (Case 344) - same 4-SIP Module (Case 344) - same MEMS SOP module - alternative form factor
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CF Sensor
Pressure Type Differential (dual port) Gauge (single port) Differential (dual port) Differential (dual port) Differential (dual port) Differential (dual port) Differential
Operating Pressure Range 0-100 kPa (0-14.5 psi) 0-100 kPa 0-200 kPa 0-10 kPa 0-50 kPa 0-50 kPa 0-100 kPa option
Full-Scale Span 40 mV (at 10 V) 40 mV (at 10 V) 40 mV (at 10 V) 25 mV (at 10 V) 40 mV (at 10 V) 40 mV (at 10 V) mV output (range-dependent)
Supply Voltage 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 10 V DC 5 V DC
Port Size 0.19 in (4.93 mm) dual axial 0.19 in single axial 0.19 in dual axial 0.19 in dual axial 0.19 in dual axial 0.19 in dual axial MEMS port
Technology Silicon piezoresistive Silicon piezoresistive Silicon piezoresistive Silicon piezoresistive Silicon piezoresistive Silicon piezoresistive MEMS piezoresistive

Bảo phân biệt quan trọng

  • Dual-port differential configuration in a single 4-SIP package (vsMPX2100GP)
  • 100 kPa range covers medical and HVAC differential pressures (vsMPX2200DP)
  • Mature NXP MPX silicon piezoresistive platform (vsXGZP192)

Ghi chú thiết kế

The MPX2100DP requires a stable 10 V DC excitation source for rated 40 mV full-scale output. Estimated: at 10 V supply, typical bridge current is approximately 6 mA. Use a precision reference such as REF02 or REF5050 with a low-dropout regulator to derive the 10 V rail, and decouple with a 0.1 uF ceramic capacitor placed within 5 mm of the sensor supply pin to suppress supply noise that would otherwise appear on the mV signal.

The 40 mV full-scale output is small and easily corrupted by noise. Route the sensor outputs as a differential pair with matched trace lengths and a guard ground plane. Use a low-noise instrumentation amplifier such as INA128 or AD620 with gain of 50-100 to bring the signal into the 2-4 V ADC input range. Avoid ground loops by using a single-point star ground at the ADC reference.

Common design mistakes with the MPX2100DP include: (1) using an unregulated 10 V supply that drifts with load, causing span error proportional to supply variation; (2) omitting temperature compensation calibration, which can introduce 1-2% FS error across the 0-85C range; (3) applying excessive mechanical stress to the tube ports, which can crack the silicone die attachment and cause offset drift; (4) ignoring moisture ingress through the tube ports, which requires hydrophobic filters for humid-media applications.

The MPX2100DP is compensated over 0C to 85C, but its long-term thermal cycling characteristics depend on the host assembly. Avoid mounting the sensor near heat sources such as power resistors or microcontrollers. Estimated: thermal hysteresis is typically 0.5% FS over 0-85C when the device is mounted on a standard FR4 PCB with normal copper pours. For higher-precision applications, mount the sensor on an isothermal section of the board or use thermal isolation.

Thông tin tuân thủ

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Không chì
Yes
Không halogen
Unknown
Khoáng vật xung đột
Compliant

RoHS and REACH compliant per NXP product page. Not AEC-Q100 qualified - this is a pressure sensor, not an automotive IC. Halogen-free status not explicitly stated in available data.

Dữ liệu được xác minh vào: 2026-10-15 — dữ liệu được xác minh và quản lý bởi đội ngũ kỹ thuật phần cứng của XAIPART

Tìm kiếm liên quan

MPX2100DP datasheet MPX2100DP pressure sensor NXP MPX2100DP specifications MPX2100DP 100 kPa differential MPX2100DP 4-SIP module pinout MPX2100DP medical respiratory monitor MPX2100DP HVAC filter clog detection MPX2100DP vs MPX2100AP MPX2100DP drop-in replacement MPX2100DP buy price 100kPa MPX2100DP NXP equivalent same package piezoresistive differential pressure sensor 100kPa

Các bộ phận và thuật ngữ liên quan

NXP Semiconductors STMicroelectronics Motorola MPX2100DP MPX2100AP MPX2100GP MPX2200DP MPX2010DP MPX2050DP MPX2053DP XGZP192 CF Sensor piezoresistive pressure sensor MEMS transducer differential pressure sensor Wheatstone bridge 4-SIP module Case 344C-01 silicon diaphragm instrumentation amplifier INA128 AD620 RoHS REACH HVAC medical respiratory monitor
Báo giá nhanh RFQ
Hãy điền đầy đủ thông tin — đội ngũ bán hàng của chúng tôi sẽ phản hồi trong vòng 24 giờ
Mã sản phẩm Nhà sản xuất Kiểu đóng gói QTY Giá mục tiêu Phụ
✓
Báo giá đã gửi!

Chúng tôi sẽ trả lời email của bạn trong vòng 24 giờ

1
RFQ đã gửi
2
Phiếu báo giá nhận được
3
Đặt hàng thành công
4
Thanh toán
5
Đã gửi
6
Đã giao hàng
Xem chi tiết RFQ