A shielded twisted-pair (STP) cable is a balanced transmission medium that uses 90-ohm nominal differential impedance and twisted conductors to cancel common-mode noise, allowing Gigabit and Fast Ethernet signaling to coexist with motor drives, VFDs, and switching power supplies. Within the broader cable hierarchy, Belden 9937 sits in the data-communication / industrial-Ethernet branch, below generic power cables and above unshielded twisted-pair (UTP) Cat5e offerings; it serves as the physical layer that connects PLCs, HMIs, vision systems, and industrial Ethernet switches.
Key features include a 100 MHz bandwidth rating (Cat5e), characteristic impedance of 100 ohms, an overall foil + braid double-shield construction for EMI suppression, and a CM-rated PVC jacket suitable for in-wall and tray installation. Operating temperature range is typically -30C to +75C, and the cable is RoHS compliant per Belden product literature.
The construction pairs 24-25 AWG solid or stranded tinned copper conductors with FPE dielectric, achieving low capacitance (~13 pF/ft typical) and low attenuation at 100 MHz. The aluminum/Mylar foil shield provides 100% coverage against high-frequency interference while the tinned copper braid adds mechanical ruggedness and low-frequency EMI suppression. This dual-shield approach makes the 9937 well-suited for installations adjacent to variable-frequency drives and other switching-noise sources.
Typical applications include industrial Ethernet backbone cabling, PLC-to-PLC communication links, motor-drive feedback signal wiring, factory-floor network drops, and SCADA system interconnects. It is also used in machine vision systems where deterministic data integrity is required.
When routing the 9937, maintain at least 12 inches of separation from VFD power cables and cross power conductors at 90-degree angles when crossing is unavoidable. The overall braid shield must be terminated 360 degrees at both ends to chassis ground using metal backshells to realize the full EMI rejection benefit.
This page synthesizes distributor pricing, drop-in alternatives, and practical installation guidance not found in the manufacturer datasheet, helping engineers select and deploy the correct shielded Ethernet cable for industrial environments.
Bộ thay thế dễ dàng lắp đặt cho QQ9937 — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với QQ9937 (cùng hình factor và footprint) — khác nhau ở Operating Temperature, Product Type.
7918A
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
PCF7936AS
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →7917A
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
ETHERLINE Cat5e FD
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
GenSPEED 5000
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
CS-37P
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
QQ9937 Thông số kỹ thuật
| Manufacturer | Belden Inc. |
| Product Type | Fast Ethernet Cat5e Data Single-Ended Cordset |
| Cable Category | Cat5e |
| Conductor Size | 24-25 AWG |
| Conductor Material | Tinned Copper |
| Insulation Material | FPE (Foamed Polyethylene) |
| Shield Type | Aluminum/Mylar Foil + Tinned Copper Braid (overall) |
| Jacket Material | PVC |
| Jacket Rating | CM |
| Nominal Characteristic Impedance | 100 ohms |
| Bandwidth Rating | 100 MHz |
| Capacitance (typical) | 13 pF/ft |
| Nhiệt độ hoạt động | -30C to +75C |
| Trạng thái RoHS | Compliant |
| Cable Family | DataTuff / Industrial Ethernet |
Hướng dẫn cấu hình chân QQ9937 standard
Cấu hình chân cho QQ9937 (standard gói). Số thứ tự chân, chức năng và sơ đồ kết nối được xác định trong tài liệu thông số kỹ thuật của nhà sản xuất. Tham khảo nó để biết footprint và hướng dẫn hàn chính xác.
Không có dữ liệu chân cụ thể sẵn có cho QQ9937.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
QQ9937 phù hợp cho 6 Áp dụngs: Industrial Ethernet Backbone Cabling, PLC-to-PLC Communication Links, Motor Drive Feedback Signal Wiring, Machine Vision System Networking, Factory Floor Network Drops, SCADA System Interconnects.
Industrial Ethernet Backbone Cabling
The Belden 9937's 100 MHz Cat5e bandwidth and 100 ohm nominal impedance make it ideal for industrial Ethernet backbone cabling connecting PLCs, HMIs, and managed switches in factory automation cells. Its foil + braid double-shield construction rejects EMI from variable-frequency drives and motor contactors that would otherwise corrupt unshielded Ethernet links. Plenum and riser backbone runs up to 100 m are supported without signal integrity loss, and the CM-rated PVC jacket permits installation in cable trays and conduit per NEC Article 800.
Được đề xuất
PLC-to-PLC Communication Links
The Belden 9937's 24-25 AWG tinned copper conductors with FPE insulation deliver low attenuation and stable 100 ohm impedance for deterministic PLC-to-PLC Ethernet/IP, PROFINET, and Modbus TCP communication. The braided shield provides robust protection against the high-frequency noise emitted by welding robots and motor starters on the factory floor. Typical installation lengths of 30-80 m between control cabinets achieve error-free operation at 100 Mbps, with the overall foil shield suppressing common-mode interference from VFD power cables routed in parallel trays.
Được đề xuất
Motor Drive Feedback Signal Wiring
The Belden 9937's foil + braid overall shield provides the dual-layer EMI rejection required when routing feedback signals from servo drives, encoder lines, and resolver feedback adjacent to high-current motor cables. Its 13 pF/ft typical capacitance minimizes signal distortion on the feedback encoder channel, while the CM-rated PVC jacket allows installation in shared cable trays with proper separation. The cable's -30C to +75C temperature rating covers the operating envelope of typical industrial control cabinets and machine tool enclosures.
Được đề xuất
Machine Vision System Networking
The Belden 9937's stable 100 ohm characteristic impedance and low capacitance make it well-suited for GigE Vision and real-time machine vision camera networks where deterministic data delivery is critical. Its shielded construction prevents image data corruption from adjacent strobe lighting inverters and stepper motor drives that emit broadband EMI. The Cat5e 100 MHz bandwidth comfortably supports 1 Gbps vision traffic at standard PoE distances up to 100 m, with the PVC jacket rated for the 24/7 thermal cycling of vision inspection cells.
Được đề xuất
Factory Floor Network Drops
The Belden 9937's CM-rated PVC jacket and rugged foil+braid construction make it ideal for the final network drop from overhead cable trays to floor-mounted I/O blocks, HMI panels, and field-mounted Ethernet devices. Its 24-25 AWG conductors support Power over Ethernet (PoE/PoE+) up to 25.5 W per the IEEE 802.3at specification, allowing single-cable deployment of powered sensors and wireless access points. The double-shield design maintains signal integrity when the cable is routed through existing cable trays alongside 480V motor power distribution.
Được đề xuất
SCADA System Interconnects
The Belden 9937's industrial-grade shielding and Cat5e bandwidth make it suitable for SCADA RTU-to-master communication links in water treatment, power distribution, and oil & gas supervisory systems. Its 100 ohm impedance matches standard Ethernet PHY requirements, and the overall foil + braid construction provides reliable operation near high-voltage switchgear and transformer installations. The cable's -30C to +75C temperature range covers outdoor enclosure applications when used in conduit, and the CM jacket rating supports installation in control room cable trays per NEC Article 800.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho QQ9937 — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | 7918A | 7936A | 7917A | ETHERLINE Cat5e FD | GenSPEED 5000 |
|---|---|---|---|---|---|---|
| Package | 1000 ft Reel | 1000 ft Reel - same | 1000 ft Reel - same | 1000 ft Reel - same | 1000 ft Reel - same | 1000 ft Reel - same |
| Brand | Belden | Belden | Belden | Belden | Lapp Group | General Cable |
| Cable Category | Cat5e | Cat6 | Cat5e | Cat5e | Cat5e | Cat5e |
| Bandwidth | 100 MHz | 250 MHz | 100 MHz | 100 MHz | 100 MHz | 100 MHz |
| Conductor Size | 24-25 AWG | 23 AWG | 24 AWG | 24 AWG stranded | 24 AWG | 24 AWG |
| Shield Type | Foil + Braid (overall) | Foil + Braid (overall) | Foil + Braid (overall) | Foil + Braid (overall) | Foil + Braid (overall) | Foil only |
| Jacket Rating | CM (PVC) | CM (PVC) | Outdoor (PE) | CM (PVC) | CM (PVC) | CM (PVC) |
| Impedance | 100 ohm | 100 ohm | 100 ohm | 100 ohm | 100 ohm | 100 ohm |
| Application Focus | Industrial Ethernet backbone | Gigabit Ethernet | Outdoor/burial | Flexible installations | Drag-chain/flexible | General industrial |
Bảo phân biệt quan trọng
- Double-shield foil + braid construction for high-EMI environments (vsGenSPEED 5000)
- Same-brand upgrade path to Cat6 bandwidth without re-termination (vs7918A)
- Outdoor-rated same-brand drop-in alternative (vs7936A)
Ghi chú thiết kế
Maintain at least 12 inches (30 cm) of separation between Belden 9937 and any VFD motor power cable, or cross power conductors at a 90-degree angle if crossing is unavoidable. Per NEC Article 800 and Belden installation guidelines, parallel runs of unshielded Ethernet cables alongside VFD power cables typically experience bit-error-rate degradation beyond 50 m. The 9937's foil + braid shield significantly improves this margin but does not eliminate the separation requirement.
The overall braid shield MUST be terminated 360 degrees to chassis ground at both ends using metal RJ-45 backshells (such as Stewart Connector SS-39100 series) to realize the full EMI rejection benefit. Pigtail termination with a drain wire alone typically degrades shield effectiveness above 30 MHz, causing CRC errors and link flaps on Gigabit uplinks. Always verify shield continuity with a low-resistance ohmmeter test before commissioning.
When terminating Belden 9937 to a patch panel or keystone jack, follow TIA-568 T568B wiring (most common in North America) and maintain pair twist to within 0.5 inch of the termination point. Excessive untwist increases crosstalk and can push a Cat5e link below margin at 100 MHz. Use a punch-down tool with a cutting blade (Krone or 110-style) and verify each termination with a Fluke DTX or equivalent cable certifier to confirm 100 MHz headroom.
Estimated: For a 90 m run of Belden 9937 at 100 MHz, attenuation is approximately 22 dB per the Cat5e channel limit. Insertion loss margin at the receiver end typically allows for 3-4 connector pairs and a 5 m patch cord. For runs near the 100 m maximum, perform a certification test rather than a simple continuity test to confirm the link supports the desired data rate (100 Mbps Fast Ethernet or 1 Gbps Gigabit Ethernet).
Thông tin tuân thủ
RoHS compliant per Belden product literature. PVC jacket is NOT halogen-free - choose LSZH variants (e.g., Belden 7918A LSZH) for enclosed space or transit applications. NEC CM-rated for in-wall and tray installation per Article 800.