SN65HVD11HD - 3.3V 10Mbps RS-485 Transceiver | Texas Instruments
MPN: SN65HVD11HD ✓ Hoạt độngSN65HVD11HD Tóm tắt
An RS-485 transceiver is a physical-layer interface integrated circuit that combines a differential line driver with a differential line receiver. These devices support balanced, low-noise communication over long cables and multi-node industrial buses. The SN65HVD11 belongs to the broader interface IC hierarchy, connecting embedded controllers, sensors, actuators, and industrial equipment through the TIA/EIA-485 physical layer.
The device provides a half-duplex communication path, allowing the driver and receiver to share the same differential pair when the transmitter is disabled. Its 1/8 unit-load receiver reduces input loading and permits as many as 256 nodes on one bus. Optional driver transition-time settings support signaling rates of 1 Mbps, 10 Mbps, and 32 Mbps, allowing engineers to balance signaling speed, EMI control, and cable compatibility.
Unlike the standard SN65HVD11, the SN65HVD11HD is the high-temperature SN65HVD11-HT configuration. Its operating range extends from -55°C to 175°C, while thermal shutdown is removed from the functional description. The device operates from a single 3.3 V supply and meets or exceeds ANSI TIA/EIA-485-A and ISO 8482:1993 requirements for balanced differential buses.
Typical uses include industrial automation equipment, factory-floor sensor networks, building controls, heating and cooling systems, and high-temperature motor-control electronics. The extended temperature capability is particularly useful where enclosure temperatures can approach the limits of conventional industrial integrated circuits.
Designers should preserve the differential routing between the bus pins and ground reference, place termination and protection components at the appropriate cable endpoints, and select the driver transition-time option for the required data rate. Because thermal shutdown is removed on this high-temperature variant, system-level temperature verification and enclosure thermal design are especially important.
This page combines device specifications, family drop-in alternatives, interface selection guidance, pin assignments, and application-specific design considerations to support direct engineering evaluation of the SN65HVD11HD.
Bộ thay thế dễ dàng lắp đặt cho SN65HVD11HD — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
SN65HVD11DR
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
SN65HVD10DR
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
SN65HVD12DR
✅ Drop-In ⚠️ Thông số chưa được xác minhLiên hệ để biết giá
Xem tài liệu →SN75HVD11DR
✅ Drop-In ⚠️ Thông số chưa được xác minh📋 Tham chiếu thay thế (không có trong danh mục)
SN65HVD21DR
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →SN65HVD11HD Thông số kỹ thuật
| Product Type | Differential RS-485 and RS-422 bus transceiver |
| Điện áp cung cấp | 3.3 V |
| Maximum Signaling Rate | 10 Mbps |
| Driver Transition-Time Options | 1 Mbps, 10 Mbps, and 32 Mbps |
| Number of Drivers | 1 |
| Number of Receivers | 1 |
| Duplex Mode | Half-duplex |
| Receiver Unit Load | 1/8 unit load |
| Maximum Bus Nodes | 256 nodes |
| Bus-Pin ESD Protection | Greater than 16 kV HBM |
| Khoảng nhiệt độ hoạt động | -55°C to 175°C |
| Hộp | 8-pin SOIC |
| Kiểu lắp đặt | Surface mount |
| Standards Compliance | ANSI TIA/EIA-485-A and ISO 8482:1993 |
| Signal Type | Balanced differential |
| Tắt nhiệt | Not included in SN65HVD11-HT |
| Bus Fault Protection | -9 V to 14 V |
| Manufacturer Orderable Suffix | HD |
Cấu hình chân SN65HVD11HD
| Chân 1 | RO — Receiver output |
| Chân 2 | RE — Receiver enable, active low |
| Chân 3 | DE — Driver enable, active high |
| Chân 4 | DI — Driver data input |
| Chân 5 | GND — Ground |
| Chân 6 | Y — Non-inverting differential bus terminal |
| Chân 7 | A — Inverting differential bus terminal |
| Chân 8 | VCC — 3.3 V supply |
Ứng dụng tiêu biểu
SN65HVD11HD phù hợp cho 6 Áp dụngs: Industrial Automation Bus Interface, Building HVAC Control Network, High-Temperature Motor Controller, Industrial Sensor Backbone, Process Control Equipment, Telecommunications Equipment.
Industrial Automation Bus Interface
The SN65HVD11HD fits factory automation equipment that links sensors, actuators, and controllers over a balanced RS-485 bus. Its 3.3 V supply supports modern embedded systems, while its 10 Mbps maximum signaling rate provides ample bandwidth for command and status traffic. The 1/8 unit-load receiver allows up to 256 nodes, making the device suitable for distributed machine-control networks with numerous remote modules. Place the transceiver at the bus endpoint when adding a local node and retain the differential A and B routing through the entire cable. The extended -55°C to 175°C rating supports harsh industrial environments, but thermal shutdown is absent, so enclosure temperature and copper heat spreading require explicit verification.
Được đề xuất
Building HVAC Control Network
The SN65HVD11HD can connect thermostats, room controllers, dampers, and supervisory controllers in a building-heating and cooling network. Its half-duplex architecture limits the number of physical bus lines, while the 1/8 unit-load receiver supports a larger collection of nodes than a conventional unit-load receiver. The 3.3 V operation integrates cleanly with embedded control electronics, and the 10 Mbps capability provides a substantial margin over typical building-control traffic. The -55°C to 175°C range is useful in poorly controlled cabinets, rooftop equipment, and heated enclosures. Designers should use balanced cable routing, common grounding through the cable reference, and endpoint termination matched to the installed bus topology.
Được đề xuất
High-Temperature Motor Controller
The SN65HVD11HD is suitable for command and feedback links between a motor controller and remote encoder, brake monitor, or condition-monitoring module. The differential driver and receiver reject common-mode noise more effectively than single-ended communication, which is advantageous near switching power stages and motor wiring. Its 3.3 V supply and 10 Mbps signaling capability support compact control electronics, while the 1/8 unit load allows multiple nodes on a shared bus. The extended temperature range supports equipment near hot machinery, and greater-than-16-kV HBM bus-pin ESD protection improves robustness during field connections. Because the high-temperature configuration omits thermal shutdown, thermal analysis of the complete controller is mandatory.
Được đề xuất
Industrial Sensor Backbone
The SN65HVD11HD can serve as the communications interface in a multi-sensor industrial backbone carrying pressure, temperature, level, and position measurements. The 1/8 unit-load receiver allows up to 256 nodes, while 10 Mbps signaling capacity supports both periodic telemetry and burst traffic. A 3.3 V transceiver can be placed alongside low-power sensor-processing electronics without a separate high-voltage interface rail. The extended -55°C to 175°C specification helps when sensors are distributed through cabinets, machinery, and outdoor equipment with variable thermal conditions. Maintain a continuous ground reference along the cable, avoid stubs where possible, and place any protection or termination components where they will not create an unintended impedance discontinuity.
Được đề xuất
Process Control Equipment
The SN65HVD11HD provides a differential RS-485 interface for process-control modules that exchange measurements and commands with a supervisory controller. Its 10 Mbps capability allows short-distance communication at high update rates while the 3.3 V supply simplifies integration with low-voltage control silicon. The 1/8 unit-load receiver supports a larger bus than standard full-load receivers, and the -55°C to 175°C range suits unheated cabinets, nearby furnaces, and thermally variable machinery. Bus-pin ESD protection exceeding 16 kV HBM adds useful robustness at externally accessible connections. The absence of thermal shutdown means designers must include thermal margin in the cabinet design and verify worst-case bus-node loading, cable loss, and supply conditions.
Được đề xuất
Telecommunications Equipment
The SN65HVD11HD is appropriate for communication equipment that distributes control or monitoring signals over short balanced cables. Its differential signaling reduces susceptibility to common-mode noise, and the 1/8 unit-load receiver supports dense equipment-bus arrangements. The device operates from a single 3.3 V supply and supports signaling up to 10 Mbps, providing flexibility for control backplanes, remote radio-unit monitoring, and peripheral equipment links. The extended temperature range covers outdoor cabinets and thermal-variable telecommunications installations, while the SOIC-8 package simplifies conventional surface-mount assembly. Careful separation from noisy power stages, proper reference-ground handling, and endpoint placement of protection components are necessary to preserve bus performance.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho SN65HVD11HD — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | SN65HVD11DR | SN65HVD10DR | SN65HVD12DR | SN75HVD11DR | SN65HVD21DR |
|---|---|---|---|---|---|---|
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Supply Voltage | 3.3 V | 3.3 V | 3.3 V | 3.3 V | 3.3 V | 3.3 V |
Bảo phân biệt quan trọng
- Extended-temperature operation (vsSN65HVD11DR)
- Large-node RS-485 support (vsSN65HVD10DR)
- No thermal-shutdown dependency in extreme-temperature use (vsSN65HVD12DR)
- Same-footprint high-speed differential interface (vsSN65HVD21DR)
Ghi chú thiết kế
Route the differential A and Y conductors as a tightly coupled pair over a continuous reference plane, keeping their separation approximately constant along the entire board-to-cable path. Avoid switching ground planes beneath the pair, and minimize vias because each discontinuity can reduce common-mode immunity. Place the transceiver close to the connector or cable interface so external transient energy reaches protection components before entering sensitive logic.
Thermal shutdown is removed from the SN65HVD11-HT configuration, making system thermal qualification essential. Estimate worst-case dissipation from the supply voltage, output voltage, load current, driver duty cycle, and enabled-state current, then compare the resulting junction-temperature estimate with the 175°C upper rating. Use the package copper area and surrounding board copper as a heat spreader, and account for temperature rise at both the IC and any connector or protection components.
Do not confuse the SN65HVD11HD high-temperature ordering option with the standard SN65HVD11DR device. Their electrical functions are closely related, but only the HD configuration carries the -55°C to 175°C rating and excludes thermal shutdown. Also confirm whether a design needs receiver fail-safe behavior, a particular driver transition-time option, or a different unit-load rating before selecting a family alternative.
Select the driver transition-time option according to cable length, topology, data rate, and required EMI performance. The family supports settings associated with 1 Mbps, 10 Mbps, and 32 Mbps signaling. Keep the bus topology linear, avoid unnecessary long stubs, install termination only at the physical ends of the cable, and provide a continuous signal-ground reference so differential signals maintain predictable common-mode behavior.
Thông tin tuân thủ
The device is described as meeting or exceeding ANSI TIA/EIA-485-A and ISO 8482:1993. Material-compliance declarations for RoHS, REACH, AEC-Q100, lead-free construction, halogen-free construction, and conflict minerals were not identified and remain unknown.