Analog Devices

AD7703CQ - 20-Bit Sigma-Delta ADC | Analog Devices

MPN: AD7703CQ ✓ 啟用中
±5 V Vdss 20-lead CDIP Package
MOQ: 1 |

AD7703CQ 概覽

The Analog Devices AD7703CQ is a 20-bit sigma-delta analog-to-digital converter with a 0.016 MHz sample rate, maximum specified linearity error of 0.0012%, and operation from ±5 V power supplies, housed in a 20-lead through-hole CDIP package. The AD7703CQ is designed for precision measurement systems that require high resolution, low-noise conversion, and flexible serial connectivity. Its industrial temperature grade supports operation up to 85°C.

A sigma-delta ADC is a voltage regulator category of data-converter architecture that continuously samples an analog input through a modulator. The modulator’s mean output duty cycle represents the input voltage, while digital filtering and decimation remove wideband noise and reduce the effective conversion rate. The AD7703CQ is therefore positioned between conventional flash and successive-approximation ADCs and higher-speed converters, offering strong resolution for low-bandwidth precision signals.

Key features include 20-bit resolution, self-calibration, a serial interface supporting an asynchronous UART-compatible mode and two synchronous modes, and analog input channels intended for precision instrumentation. The self-calibration system can compensate for offset and gain errors in the selected input channel. This is particularly useful when drift from sensors, reference circuitry, or long analog paths would otherwise limit measurement accuracy.

The converter uses a continuously sampled analog input and delta-sigma conversion technique. Its filtered output suits pressure, temperature, load-cell, bridge, and process-control measurements where the signal bandwidth is substantially lower than the converter’s internal sample rate. Selectable gain and digital conversion functions allow the same converter architecture to serve multiple low-level input ranges without changing the external package or pinout.

Typical applications include industrial pressure transmitters, thermocouple and RTD instrumentation, weighing systems, laboratory measurement equipment, and closed-loop process control. In each case, the AD7703CQ can convert a slowly changing analog input into a serial digital result while minimizing the need for a separate precision ADC and low-noise analog front end.

For PCB design, preserve a quiet analog input path, place input and reference components close to the converter, and decouple each supply rail locally. Allow the converter’s digital interface to be routed away from sensitive analog nodes. Check the manufacturer’s recommended input, reference, and bypass-capacitor arrangements before finalizing a board because converter accuracy depends on the complete analog signal chain.

This page organizes the AD7703CQ’s core electrical, packaging, application, and purchasing information into one engineering-focused reference. It also distinguishes confirmed manufacturer characteristics from parameters that must be checked in the current Analog Devices data sheet, helping designers evaluate this 20-bit CDIP converter efficiently.

直接替換替代品,適用於 AD7703CQ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。

此系列的變體

與下列產品可直接替換的同系列型號: AD7703CQ (相同外形與佔位) — 差異在於 Calibration, Package, Resolution, Supply Voltage.

Analog Devices
Calibration: Self-calibration for offset and gain error
Package: 20-lead ceramic dual inline package
Resolution: 20 bits
比較對象 AD7703CQ →

此產品無可直接替換的替代品。

申請替代品

AD7703CQ 最大額定值與電氣特性

Converter Type 20-bit sigma-delta ADC
解析度 20 bit
Maximum Linearity Error 0.0012%
Sample Rate 0.016 MHz
供應電壓 ±5 V
Maximum Operating Temperature 85°C
Temperature Grade Industrial
封裝 20-lead CDIP
Terminal Count 20 terminals
安裝類型 Through-hole
Package Width 0.300 inch (7.62 mm)
Conversion Technique Sigma-delta
Input Sampling Method Continuous analog modulation
Calibration Self-calibration
Digital Interface Asynchronous UART-compatible and two synchronous serial modes
RoHS 狀態 unknown

AD7703CQ 0.300 inch (7.62 mm) 腳位配置指南

AD7703CQ(0.300 inch (7.62 mm) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。

AD7703CQ 的 0.300 inch (7.62 mm) 封裝腳位圖

無詳細腳位定義資料: AD7703CQ.

請參閱 資料表 以查看完整腳位配置。

典型應用

AD7703CQ 適用於 6 應用s: Industrial Pressure Transmitters, RTD and Thermocouple Instrumentation, Precision Weighing and Load Cells, Laboratory Measurement Instruments, Industrial Process Control Loops, Slow High-Resolution Data Acquisition.

🏭

Industrial Pressure Transmitters

The AD7703CQ fits industrial pressure transmitters that digitize a low-level bridge or conditioned sensor signal at a relatively slow rate. Its 20-bit resolution provides ample conversion headroom for narrow full-scale ranges, while self-calibration can reduce offset and gain errors associated with the input channel. The ±5 V supply arrangement is compatible with classic industrial instrumentation designs. Place the converter close to the bridge and reference components, maintain a quiet analog ground path, and route its serial interface toward the transmitter controller. Because pressure inputs can experience vibration and sudden mechanical shocks, verify the complete analog filter and calibration sequence rather than relying only on the converter’s 0.0012% maximum linearity error.

🌡️

RTD and Thermocouple Instrumentation

The AD7703CQ is appropriate for RTD and thermocouple measurement modules where the temperature signal changes slowly and high-resolution conversion is more important than a high throughput rate. Its 20-bit sigma-delta architecture supports filtered digitizing of small voltage changes, and the 0.016 MHz sample rate is sufficient for many thermal loops. The self-calibration function helps compensate for systematic offset and gain errors, while the flexible serial port supports microcontroller-oriented system designs. External excitation, input protection, reference conditioning, and linearization remain part of the sensor interface. Confirm the converter’s gain, input range, filter settings, and update rate against the intended RTD resistance or thermocouple millivolt range before final calibration.

⚖️

Precision Weighing and Load Cells

The AD7703CQ can serve as the core converter in a precision weighing system driven by a strain-gauge load cell. The 20-bit resolution supports fine digital measurement from the comparatively small millivolt-level output of a bridge, and self-calibration can offset system zero and gain errors when the measurement path is stable. The filtered output is useful for stationary or slowly changing loads where aliasing from high-frequency vibration would otherwise reduce measurement quality. Use a dedicated analog section for the bridge excitation, input filtering, and reference, while keeping the serial output and digital return paths away from the sensitive bridge nodes. Mechanical vibration, temperature gradients, and parasitic bridge supply changes remain system-level error sources that should be characterized with the completed load-cell assembly.

🔬

Laboratory Measurement Instruments

The AD7703CQ is suitable for laboratory instruments that acquire low-frequency analog quantities with high resolution, including process calibration, resistance measurement, and general-purpose data acquisition. Its 20-bit converter, ±5 V operation, and flexible serial interface allow it to complement an instrument front end built around an analog switch and precision reference. The asynchronous UART-compatible mode can simplify connections to suitable controllers, while synchronous modes support clocked digital links. For laboratory accuracy, treat the converter as one element of the measurement chain: reference stability, input protection, leakage, resistor matching, and grounding can all affect the final uncertainty. Use calibration routines to characterize offset and gain, and ensure the selected digital filter and output rate meet the instrument’s required measurement bandwidth.

🏭

Industrial Process Control Loops

The AD7703CQ supports process-control loops in which a controller must monitor a slowly varying pressure, temperature, or level signal. Its filtered 20-bit conversion result can provide the digital measurement required by supervisory control logic, while the 0.016 MHz internal sample rate is well matched to many process variables. The self-calibration capability can improve channel accuracy and simplify commissioning. Because industrial environments combine slow signals with electrical noise, keep the analog input and reference network compact and provide local supply bypassing. Configure the digital filter and conversion timing to reject process noise without introducing excessive measurement latency. Alarm thresholds and control loops should also be validated under the worst expected interference, sensor failure, and temperature conditions rather than under ideal bench conditions.

🖥️

Slow High-Resolution Data Acquisition

The AD7703CQ is useful in slow, high-resolution data-acquisition systems where thermal drift, sensor output, or control signals change over seconds or minutes. The delta-sigma conversion process continuously samples the analog input, and its digital filtering favors low-frequency measurement while attenuating broadband noise. The 20-bit word length provides more detail than many lower-resolution acquisition channels, and the serial interface supports both asynchronous and synchronous controller connections. For a mixed-signal board, establish separate analog and digital grounding strategy, keep the converter’s reference quiet, and place bypass capacitors near the supply pins. Choose the conversion rate and filter bandwidth around the actual signal bandwidth. This prevents unnecessary oversampling while preserving enough averaging to obtain a useful noise and latency balance.

What is the AD7703CQ and what are its main specifications?
The AD7703CQ is a 20-bit sigma-delta analog-to-digital converter with a 0.016 MHz sample rate and a maximum specified linearity error of 0.0012%. It operates from ±5 V supplies in a 20-lead through-hole CDIP package. According to the Analog Devices manufacturer datasheet, the continuously sampled analog input and digital conversion process suit low-bandwidth precision measurements.
Where can I download the AD7703CQ datasheet PDF?
The official AD7703CQ datasheet PDF is available through the Analog Devices AD7703 product page at https://www.analog.com/en/products/ad7703.html. That page provides the manufacturer data sheet and product documentation. Use the Rev. F data sheet for the 20-bit converter, its electrical characteristics, pin descriptions, calibration behavior, and recommended application circuits.
Where can I find the AD7703CQ pinout and package details?
The AD7703CQ uses a 20-lead CDIP package with a 0.300 inch, or 7.62 mm, row spacing and through-hole mounting. Its complete pin descriptions and numbered package drawing are in the Analog Devices manufacturer data sheet linked from the official AD7703 product page. The package is represented on this page by the 20-pin DIP diagram because its individual terminal names were not reproduced on the product page.
What applications are suitable for the AD7703CQ?
The AD7703CQ is suitable for pressure transmitters, temperature sensors, weighing systems, laboratory instrumentation, and industrial process-control loops. Its 20-bit resolution, ±5 V operation, and self-calibration support low-level analog measurements. According to the Analog Devices manufacturer datasheet, the continuously sampled sigma-delta architecture is especially appropriate when the measured signal changes more slowly than the internal sample rate.
Does the AD7703CQ need a separate precision voltage reference?
The AD7703CQ is used with an external voltage reference for accurate conversion, but the permitted reference range and application requirements must be confirmed in the Analog Devices manufacturer data sheet. A reference with excessive noise or drift can degrade the nominal 20-bit resolution and 0.0012% maximum linearity specification, so reference selection belongs to the complete analog-design review.
What are the key design considerations for an AD7703CQ circuit?
Keep analog input and reference routing short, place bypass capacitors close to the supply pins, and isolate the serial data path from sensitive analog nodes. The Analog Devices manufacturer data sheet’s recommended application circuit should guide component values and grounding. Because converter performance depends on reference quality, input filtering, clocking, and digital decimation as well as the ADC itself, board-level validation is essential.
How does the AD7703CQ compare with ADuM7703?
The AD7703CQ is a 20-bit sigma-delta ADC in a 20-lead CDIP package, while the ADuM7703 is a separate Analog Devices isolated data-converter product with a different isolation-oriented architecture and package. They both use delta-sigma conversion principles, but the ADuM7703 is not a pin-to-pin AD7703CQ replacement. Choose according to isolation, package, interface, and channel requirements rather than resolution alone.
AD7703CQ vs ADuM7703: which is better for a precision measurement board?
The AD7703CQ is the better match for a conventional precision measurement board that uses ±5 V supplies and a direct non-isolated analog input. The ADuM7703 is more appropriate when galvanic isolation is central to the design. The two devices have different packages and interfaces, so the comparison is architectural rather than a drop-in substitution; both are 20-bit-class delta-sigma conversion solutions.
When should I choose the AD7703CQ over another sigma-delta ADC?
Choose the AD7703CQ when the design needs 20-bit resolution, ±5 V analog operation, industrial temperature capability, and a through-hole 20-lead CDIP implementation. Its self-calibration and flexible serial interface support precise low-bandwidth acquisition. If a smaller surface-mount package, integrated reference, isolated channel, or different serial protocol is required, compare those requirements against the current manufacturer data sheet before choosing.
Is the AD7703CQ suitable for pressure transmitter and RTD measurement?
Yes, the AD7703CQ is suitable for pressure-transmitter, RTD, and other low-frequency precision measurements. Its 20-bit conversion resolution and self-calibration can support accurate digitizing of slowly varying sensor outputs, while the filtered sigma-delta architecture rejects wideband noise. Input range, gain, excitation strategy, and excitation current must still be configured around the chosen sensor and bridge.
What is the best drop-in replacement for the AD7703CQ?
No verified drop-in replacement for the AD7703CQ was identified in the available manufacturer and cross-reference information. A valid replacement would need the same 20-lead CDIP footprint, compatible ±5 V operation, equivalent resolution and linearity, matching serial-interface timing, and suitable industrial-temperature qualification. Avoid treating a merely similar converter as drop-in without checking its complete pin description.
Can another Analog Devices ADC directly replace the AD7703CQ?
No direct replacement can be confirmed solely from the AD7703CQ product-page information. Some Analog Devices converters may offer similar conversion resolution or interface features, but direct substitution requires matching the 20-lead pinout, supply arrangement, analog input range, calibration behavior, timing, and serial protocol. Review the manufacturer’s data sheet and application requirements for any proposed substitute.
Where can I buy AD7703CQ online and what is the current price?
Use the Request a Quote form on this page to ask for AD7703CQ availability, current pricing, and order handling. The product page identifies the converter as an Analog Devices 20-bit ADC, and a distributor listing describes the component as currently in production. Quote requests are the appropriate way to confirm the exact package suffix, quantity breaks, and current commercial terms.
What is the lead time for AD7703CQ?
AD7703CQ lead time should be confirmed through the Request a Quote form on this page rather than inferred from a generic listing. Lead time can vary with order quantity, factory inventory, and the requested package and delivery terms. Include the intended quantity, target date, and whether authorized sourcing or independent sourcing is required when submitting the request.
Is the AD7703CQ in stock and active?
The AD7703CQ is described as currently in active production, and a distributor listing reports stock for the exact 20-CDIP part. Inventory levels can change rapidly, so use the Request a Quote form on this page for a current availability confirmation. Quote requests are the appropriate way to confirm the exact package suffix, quantity breaks, and current commercial terms.
What compliance and qualification information applies to the AD7703CQ?
The AD7703CQ is identified as an industrial-temperature-grade component, but its RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status should be checked on the official Analog Devices product page or current declarations. Its industrial grade does not by itself mean that it is AEC-Q100-qualified for automotive use. Request the current compliance documentation before release to a regulated production program.

工程參考資料,適用於 AD7703CQ — 比較、設計指引及合規資訊。

選型指南

Choose the AD7703CQ when the design requires a 20-bit sigma-delta ADC, ±5 V operation, industrial temperature capability, and a 20-lead through-hole CDIP package. It is particularly effective for slow pressure, temperature, load-cell, and laboratory measurements where filtered conversion is more valuable than high throughput. Choose ADuM7703 when galvanic isolation is required; it is not a pin-compatible replacement. Choose another converter when surface-mount packaging, a different supply arrangement, faster sampling, or another serial protocol is mandatory. No verified drop-in substitute was identified for the exact AD7703CQ, so any proposed alternative must be checked against pin assignment, reference requirements, gain structure, calibration behavior, digital timing, and absolute maximum ratings before PCB substitution.

與替代品比較

參數 本產品
Brand Analog Devices
Package 20-lead CDIP
Mounting Type Through-hole
Resolution 20 bit
Converter Architecture Sigma-delta
Maximum Linearity Error 0.0012%
Sample Rate 0.016 MHz
Supply Voltage ±5 V
Maximum Operating Temperature 85°C
Calibration Self-calibration

主要差異化特點

  • High conversion resolution for a low-bandwidth instrumentation ADC (對比ADuM7703)
  • Through-hole CDIP implementation (對比ADuM7703)
  • Factory-trimmed-style measurement workflow with self-calibration (對比Lower-resolution generic ADCs)

設計說明

Keep the analog input, reference, and supply bypass networks compact and place them adjacent to the AD7703CQ pins. Route the serial interface away from the analog input and reference nodes, and use the manufacturer’s recommended grounding arrangement. Converter performance is determined by the complete signal chain, so PCB parasitics and reference noise can negate the nominal 20-bit resolution and 0.0012% linearity specification.

Select the digital filter and conversion timing around the intended measurement bandwidth rather than operating at the maximum 0.016 MHz rate without considering averaging. Higher processing rates generally provide more digital filtering but reduce the output update rate. Validate the latency requirement for control loops and verify that unwanted out-of-band noise is adequately attenuated before applying the final input filter.

Do not assume that a 20-bit converter automatically delivers 20-bit usable accuracy. Reference drift, resistor tolerances, input leakage, excitation variation, grounding, and inadequate filtering can dominate the measurement error. Use self-calibration as part of a controlled system calibration sequence, and confirm the permitted analog input and reference ranges in the Analog Devices manufacturer data sheet before selecting external components.

Provide clean ±5 V rails and place the recommended bypass capacitors directly across the appropriate supply pins. Because this device operates with positive and negative analog supplies, pay particular attention to the negative-rail return path and its relationship to analog ground. Review the manufacturer’s absolute maximum ratings, supply sequencing requirements, and startup behavior before connecting external circuitry that could backfeed either rail.

合規資訊

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
無鉛
Unknown
無鹵
Unknown
衝突礦產
Unknown

The component is identified as industrial grade. Current product-specific environmental and material compliance declarations should be obtained from Analog Devices before production release.

資料驗證日期: 2026-11-22 — 資料由 XAIPART 元件工程團隊驗證及整理

相關搜尋

AD7703CQ datasheet AD7703CQ datasheet pdf AD7703CQ pinout AD7703CQ package AD7703CQ equivalent AD7703CQ replacement AD7703CQ cross reference AD7703CQ vs ADuM7703 AD7703CQ price AD7703CQ stock Analog Devices AD7703CQ AD7703CQ 20-bit ADC AD7703CQ 20-CDIP AD7703CQ pressure transmitter

相關元件與詞彙

Analog Devices AD7703CQ ADuM7703 ADS1220IPW CS5530-ISZ sigma-delta ADC analog-to-digital converter data converter integrated circuit 20-bit resolution 0.0012% maximum linearity error 0.016 MHz sample rate self-calibration continuous analog sampling UART-compatible serial interface synchronous serial interface CDIP DIP package through-hole package industrial temperature grade pressure measurement RTD measurement load-cell measurement precision instrumentation
快速報價 RFQ
請填寫完整詳細資料 — 我們的業務團隊將於 24 小時內回覆
料號 製造商 封裝 QTY 目標價格 小計
✓
報價已提交!

我們將於 24 小時內回覆您的電子郵件

1
詢價已提交
2
已收到報價
3
已下單
4
付款
5
已出貨
6
已送達
檢視詢價單詳情