AD7703CQ - 20-Bit Sigma-Delta ADC | Analog Devices
MPN: AD7703CQ ✓ 啟用中AD7703CQ 概覽
A sigma-delta ADC is a voltage regulator category of data-converter architecture that continuously samples an analog input through a modulator. The modulator’s mean output duty cycle represents the input voltage, while digital filtering and decimation remove wideband noise and reduce the effective conversion rate. The AD7703CQ is therefore positioned between conventional flash and successive-approximation ADCs and higher-speed converters, offering strong resolution for low-bandwidth precision signals.
Key features include 20-bit resolution, self-calibration, a serial interface supporting an asynchronous UART-compatible mode and two synchronous modes, and analog input channels intended for precision instrumentation. The self-calibration system can compensate for offset and gain errors in the selected input channel. This is particularly useful when drift from sensors, reference circuitry, or long analog paths would otherwise limit measurement accuracy.
The converter uses a continuously sampled analog input and delta-sigma conversion technique. Its filtered output suits pressure, temperature, load-cell, bridge, and process-control measurements where the signal bandwidth is substantially lower than the converter’s internal sample rate. Selectable gain and digital conversion functions allow the same converter architecture to serve multiple low-level input ranges without changing the external package or pinout.
Typical applications include industrial pressure transmitters, thermocouple and RTD instrumentation, weighing systems, laboratory measurement equipment, and closed-loop process control. In each case, the AD7703CQ can convert a slowly changing analog input into a serial digital result while minimizing the need for a separate precision ADC and low-noise analog front end.
For PCB design, preserve a quiet analog input path, place input and reference components close to the converter, and decouple each supply rail locally. Allow the converter’s digital interface to be routed away from sensitive analog nodes. Check the manufacturer’s recommended input, reference, and bypass-capacitor arrangements before finalizing a board because converter accuracy depends on the complete analog signal chain.
This page organizes the AD7703CQ’s core electrical, packaging, application, and purchasing information into one engineering-focused reference. It also distinguishes confirmed manufacturer characteristics from parameters that must be checked in the current Analog Devices data sheet, helping designers evaluate this 20-bit CDIP converter efficiently.
直接替換替代品,適用於 AD7703CQ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD7703CQ (相同外形與佔位) — 差異在於 Calibration, Package, Resolution, Supply Voltage.
此產品無可直接替換的替代品。
申請替代品AD7703CQ 最大額定值與電氣特性
| Converter Type | 20-bit sigma-delta ADC |
| 解析度 | 20 bit |
| Maximum Linearity Error | 0.0012% |
| Sample Rate | 0.016 MHz |
| 供應電壓 | ±5 V |
| Maximum Operating Temperature | 85°C |
| Temperature Grade | Industrial |
| 封裝 | 20-lead CDIP |
| Terminal Count | 20 terminals |
| 安裝類型 | Through-hole |
| Package Width | 0.300 inch (7.62 mm) |
| Conversion Technique | Sigma-delta |
| Input Sampling Method | Continuous analog modulation |
| Calibration | Self-calibration |
| Digital Interface | Asynchronous UART-compatible and two synchronous serial modes |
| RoHS 狀態 | unknown |
AD7703CQ 0.300 inch (7.62 mm) 腳位配置指南
AD7703CQ(0.300 inch (7.62 mm) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD7703CQ.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD7703CQ 適用於 6 應用s: Industrial Pressure Transmitters, RTD and Thermocouple Instrumentation, Precision Weighing and Load Cells, Laboratory Measurement Instruments, Industrial Process Control Loops, Slow High-Resolution Data Acquisition.
Industrial Pressure Transmitters
The AD7703CQ fits industrial pressure transmitters that digitize a low-level bridge or conditioned sensor signal at a relatively slow rate. Its 20-bit resolution provides ample conversion headroom for narrow full-scale ranges, while self-calibration can reduce offset and gain errors associated with the input channel. The ±5 V supply arrangement is compatible with classic industrial instrumentation designs. Place the converter close to the bridge and reference components, maintain a quiet analog ground path, and route its serial interface toward the transmitter controller. Because pressure inputs can experience vibration and sudden mechanical shocks, verify the complete analog filter and calibration sequence rather than relying only on the converter’s 0.0012% maximum linearity error.
推薦
RTD and Thermocouple Instrumentation
The AD7703CQ is appropriate for RTD and thermocouple measurement modules where the temperature signal changes slowly and high-resolution conversion is more important than a high throughput rate. Its 20-bit sigma-delta architecture supports filtered digitizing of small voltage changes, and the 0.016 MHz sample rate is sufficient for many thermal loops. The self-calibration function helps compensate for systematic offset and gain errors, while the flexible serial port supports microcontroller-oriented system designs. External excitation, input protection, reference conditioning, and linearization remain part of the sensor interface. Confirm the converter’s gain, input range, filter settings, and update rate against the intended RTD resistance or thermocouple millivolt range before final calibration.
推薦
Precision Weighing and Load Cells
The AD7703CQ can serve as the core converter in a precision weighing system driven by a strain-gauge load cell. The 20-bit resolution supports fine digital measurement from the comparatively small millivolt-level output of a bridge, and self-calibration can offset system zero and gain errors when the measurement path is stable. The filtered output is useful for stationary or slowly changing loads where aliasing from high-frequency vibration would otherwise reduce measurement quality. Use a dedicated analog section for the bridge excitation, input filtering, and reference, while keeping the serial output and digital return paths away from the sensitive bridge nodes. Mechanical vibration, temperature gradients, and parasitic bridge supply changes remain system-level error sources that should be characterized with the completed load-cell assembly.
推薦
Laboratory Measurement Instruments
The AD7703CQ is suitable for laboratory instruments that acquire low-frequency analog quantities with high resolution, including process calibration, resistance measurement, and general-purpose data acquisition. Its 20-bit converter, ±5 V operation, and flexible serial interface allow it to complement an instrument front end built around an analog switch and precision reference. The asynchronous UART-compatible mode can simplify connections to suitable controllers, while synchronous modes support clocked digital links. For laboratory accuracy, treat the converter as one element of the measurement chain: reference stability, input protection, leakage, resistor matching, and grounding can all affect the final uncertainty. Use calibration routines to characterize offset and gain, and ensure the selected digital filter and output rate meet the instrument’s required measurement bandwidth.
推薦
Industrial Process Control Loops
The AD7703CQ supports process-control loops in which a controller must monitor a slowly varying pressure, temperature, or level signal. Its filtered 20-bit conversion result can provide the digital measurement required by supervisory control logic, while the 0.016 MHz internal sample rate is well matched to many process variables. The self-calibration capability can improve channel accuracy and simplify commissioning. Because industrial environments combine slow signals with electrical noise, keep the analog input and reference network compact and provide local supply bypassing. Configure the digital filter and conversion timing to reject process noise without introducing excessive measurement latency. Alarm thresholds and control loops should also be validated under the worst expected interference, sensor failure, and temperature conditions rather than under ideal bench conditions.
推薦
Slow High-Resolution Data Acquisition
The AD7703CQ is useful in slow, high-resolution data-acquisition systems where thermal drift, sensor output, or control signals change over seconds or minutes. The delta-sigma conversion process continuously samples the analog input, and its digital filtering favors low-frequency measurement while attenuating broadband noise. The 20-bit word length provides more detail than many lower-resolution acquisition channels, and the serial interface supports both asynchronous and synchronous controller connections. For a mixed-signal board, establish separate analog and digital grounding strategy, keep the converter’s reference quiet, and place bypass capacitors near the supply pins. Choose the conversion rate and filter bandwidth around the actual signal bandwidth. This prevents unnecessary oversampling while preserving enough averaging to obtain a useful noise and latency balance.
推薦
推薦產品摘要
工程參考資料,適用於 AD7703CQ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 |
|---|---|
| Brand | Analog Devices |
| Package | 20-lead CDIP |
| Mounting Type | Through-hole |
| Resolution | 20 bit |
| Converter Architecture | Sigma-delta |
| Maximum Linearity Error | 0.0012% |
| Sample Rate | 0.016 MHz |
| Supply Voltage | ±5 V |
| Maximum Operating Temperature | 85°C |
| Calibration | Self-calibration |
主要差異化特點
- High conversion resolution for a low-bandwidth instrumentation ADC (對比ADuM7703)
- Through-hole CDIP implementation (對比ADuM7703)
- Factory-trimmed-style measurement workflow with self-calibration (對比Lower-resolution generic ADCs)
設計說明
Keep the analog input, reference, and supply bypass networks compact and place them adjacent to the AD7703CQ pins. Route the serial interface away from the analog input and reference nodes, and use the manufacturer’s recommended grounding arrangement. Converter performance is determined by the complete signal chain, so PCB parasitics and reference noise can negate the nominal 20-bit resolution and 0.0012% linearity specification.
Select the digital filter and conversion timing around the intended measurement bandwidth rather than operating at the maximum 0.016 MHz rate without considering averaging. Higher processing rates generally provide more digital filtering but reduce the output update rate. Validate the latency requirement for control loops and verify that unwanted out-of-band noise is adequately attenuated before applying the final input filter.
Do not assume that a 20-bit converter automatically delivers 20-bit usable accuracy. Reference drift, resistor tolerances, input leakage, excitation variation, grounding, and inadequate filtering can dominate the measurement error. Use self-calibration as part of a controlled system calibration sequence, and confirm the permitted analog input and reference ranges in the Analog Devices manufacturer data sheet before selecting external components.
Provide clean ±5 V rails and place the recommended bypass capacitors directly across the appropriate supply pins. Because this device operates with positive and negative analog supplies, pay particular attention to the negative-rail return path and its relationship to analog ground. Review the manufacturer’s absolute maximum ratings, supply sequencing requirements, and startup behavior before connecting external circuitry that could backfeed either rail.
合規資訊
The component is identified as industrial grade. Current product-specific environmental and material compliance declarations should be obtained from Analog Devices before production release.