A sigma-delta ADC is a signal-conditioning and conversion category that uses a delta-sigma modulator and digital filtering to provide high resolution from relatively low-resolution internal converters. For low-frequency measurements, this architecture trades conversion speed for excellent noise performance and integration. In the broader hierarchy, the AD7712 belongs to analog-to-digital converters within integrated circuits and signal-chain conditioning for precision measurement.
The AD7712’s principal features include 24-bit conversion resolution, two analog input channels, direct transducer-signal support, serial digital output, and input-span system calibration. Its analog front end allows one input to handle low-level sensor excitation and the other to handle higher-level voltages. A precision application therefore requires suitable excitation, reference, input filtering, grounding, and digital-interface implementation rather than only direct sensor wiring.
The sigma-delta conversion technique can achieve up to 24 bits of no-missing-codes performance according to the Analog Devices manufacturer datasheet. Because the converter is optimized for low-frequency measurement, digital filter settling time and output data rate are important system variables. Designers should select output rates and filter settings that satisfy the required measurement bandwidth while retaining the noise and calibration behavior needed for the target accuracy.
Typical uses include pressure and load-cell instrumentation, temperature measurement bridges, industrial process monitoring, laboratory measurement systems, and portable low-frequency sensor acquisition. The two-channel architecture is useful when a system must measure a low-level bridge signal alongside a higher-level reference, auxiliary, or diagnostic input through the same conversion interface.
The most important design consideration is maintaining a clean, low-noise analog path around the converter. Use the pin-description and application information in the manufacturer datasheet when assigning input, reference, digital-interface, power, and decoupling connections. Verify the selected excitation voltage against the input limits, and account for converter latency and digital-filter settling before placing acquired samples into a control or data-acquisition sequence.
This product page combines the manufacturer’s device description with application guidance, replacement analysis, and design-oriented context. It is intended to help engineers determine whether the AD7712AQ’s 24-bit resolution, dual analog inputs, calibration capability, and 24-pin DIP implementation match a precision measurement design before moving to the datasheet for final schematic and component-selection work.
直接替換替代品,適用於 AD7712AQ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD7712AQ (相同外形與佔位) — 差異在於 Calibration Method.
AD7712ANZ
✅ 直接替換📋 參考替代品(不在目錄中)
AD7712SQ
✅ 直接替換📋 參考替代品(不在目錄中)
AD7712AQ 最大額定值與電氣特性
| Converter Type | 24-bit sigma-delta ADC |
| Analog Input Channels | 2 channels |
| 解析度 | 24 bits |
| Input Signal Range | Direct low-level transducer signals or high-level signals up to ±4 × VREF |
| Conversion Technology | Sigma-delta conversion |
| Output Format | Serial digital word |
| Process Technology | CMOS |
| Package Type | 24-pin through-hole DIP |
| Terminal Count | 24 terminals |
| Package Shape | Rectangular |
| 安裝類型 | Through-hole |
| Temperature Grade | Industrial |
| Calibration Method | System gain and offset calibration using applied input span |
| Reference Input | External VREF |
| RoHS 狀態 | unknown |
| REACH Status | unknown |
AD7712AQ rectangular 腳位配置指南
AD7712AQ(rectangular 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD7712AQ.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD7712AQ 適用於 6 應用s: Load-Cell Instrumentation, Pressure Sensor Acquisition, Temperature Measurement Bridges, Industrial Process Monitoring, Laboratory Instrument Signal Capture, Portable Sensor Interfaces.
Load-Cell Instrumentation
AD7712AQ fits precision load-cell and weighing systems because it combines a 24-bit sigma-delta converter with an analog input that accepts low-level transducer signals directly. The converter is intended for low-frequency measurement, allowing excitation and sensor output to settle before each serial result is read. Its two-channel structure can support a bridge measurement alongside an auxiliary temperature or status input. System gain and offset calibration should be performed with known voltages spanning the operating range, while careful grounding and filtering preserve the low-level signal integrity that makes the 24-bit resolution useful.
推薦
Pressure Sensor Acquisition
AD7712AQ is appropriate for piezoresistive pressure sensors that produce small differential or ratiometric signals and require more resolution than a conventional general-purpose converter provides. Its low-frequency sigma-delta architecture supports accurate acquisition when the sensor signal changes slowly, while the 24-bit result can preserve useful detail in the digitized pressure value. The measurement chain should minimize connector and trace noise, maintain a stable bridge excitation, and allow sufficient digital-filter settling after calibration or channel selection.
推薦
Temperature Measurement Bridges
AD7712AQ can digitize bridge-based temperature sensors when the design requires slow, precise readings rather than rapid thermal transient capture. The dual analog inputs allow a bridge or reference channel to be paired with another process or diagnostic input, while system calibration corrects gain and offset errors introduced by the measurement chain. Because accuracy depends on excitation and reference stability, the bridge supply and VREF arrangement need careful grounding and decoupling. The serial interface also supports microcontroller or programmable-controller acquisition without requiring a high-speed parallel bus.
推薦
Industrial Process Monitoring
AD7712AQ fits industrial process monitoring loops that measure slow pressure, level, force, or resistance-related signals and transmit each result over a serial interface. Its two analog input channels reduce the need for unrelated measurement front ends when a process sensor must be checked against an auxiliary voltage. The 24-bit resolution supports detailed process records and control diagnostics, while system calibration can compensate for signal-chain offset and gain. The design must account for filter settling and conversion latency when the controller sets sampling intervals or sequences multiple channel acquisitions.
推薦
Laboratory Instrument Signal Capture
AD7712AQ is suitable for laboratory instruments that capture low-frequency sensor or control voltages with higher resolution than a conventional low-cost ADC. The serial output and dual inputs permit compact integration into a measurement front end, while the 24-bit conversion result supports calibration tables, compensation, and long-term data logging. For a laboratory design, the analog section should include defined input filtering, reference routing, and a controlled grounding strategy. Firmware should identify each settled output with its selected channel and calibration state rather than treating a newly selected conversion as immediately valid.
推薦
Portable Sensor Interfaces
AD7712AQ can serve in portable measurement equipment when low signal frequency, compact size, and calibrated resolution are more important than rapid waveform sampling. The through-hole DIP package supports prototyping, inspection, and repair workflows, while the serial interface connects to a microcontroller or embedded controller. Battery-powered designs should verify supply-current behavior and power-sequencing requirements from the manufacturer datasheet because those operating details are essential to battery life. Analog input conditioning should also avoid drawing unnecessary current from sensors or excitation circuitry during standby periods.
推薦
推薦產品摘要
工程參考資料,適用於 AD7712AQ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD7712ANZ | AD7712SQ |
|---|---|---|---|
| Package | 24-pin through-hole DIP | 24-pin PDIP-24 | 24-pin through-hole DIP |
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Converter Type | 24-bit sigma-delta ADC | 24-bit sigma-delta ADC | 24-bit sigma-delta ADC |
| Analog Input Channels | 2 channels | 2 channels | 2 channels |
| Input Signal Support | Low-level transducer signals or high-level signals up to ±4 × VREF | Consistent functional characteristics | Consistent functional characteristics |
| Output Interface | Serial digital output | Consistent terminals and functional characteristics | Consistent terminals and functional characteristics |
| Calibration | System gain and offset calibration using applied input span | Consistent functional characteristics | Consistent functional characteristics |
| Terminal Count | 24 terminals | 24 pins | 24 pins |
主要差異化特點
- Two analog channels in one measurement converter (對比AD7712ANZ)
- 24-bit resolution with system span calibration (對比AD7712SQ)
- Direct low-level transducer input support (對比AD7712ANZ)
- Industrial through-hole DIP construction (對比AD7712SQ)
設計說明
Route the two analog inputs, VREF connection, supply connections, and ground return paths away from digital clock and serial-data traces. Place input filtering and reference components close to their corresponding device pins. For a bridge or transducer input, use a quiet analog ground region and return sensor current through a controlled path so switching current does not share the sensitive signal-return impedance.
Treat the reference voltage as a measurement input rather than a convenience supply rail. Stabilize VREF according to the manufacturer application guidance and include filtering appropriate to the reference source. Because system gain calibration is referenced to the applied span, reference noise, drift, or loading can appear directly in the measured value even when the ADC itself is operating correctly.
Do not read the first serial word after changing the input channel or initiating a calibration as though it were a settled measurement. The sigma-delta digital filter requires time to settle, and the conversion sequence must follow the channel-selection and calibration procedure in the manufacturer datasheet. Include this latency in control-loop timing and in laboratory acquisition software.
Separate analog and digital supply requirements into the schematic only after confirming their permitted ranges and sequencing from the manufacturer electrical-characteristics table. Follow the manufacturer decoupling recommendations at the device pins and provide stable local supply energy for the converter and reference circuitry. Avoid deriving a noisy reference from a switching node when the measurement target requires low-level accuracy.