AD7714YNZ - 24-Bit Sigma-Delta ADC | Analog Devices
MPN: AD7714YNZ ✗ 停產AD7714YNZ 概覽
An ADC converts an analog voltage into a digital numerical value. The sigma-delta ADC category uses oversampling and digital filtering to obtain high resolution with good low-frequency accuracy. Within the Analog Devices signal-conditioning ADC family, the AD7714 integrates programmable gain, input filtering, reference handling, and serial output into one device, reducing the need for separate conditioning stages in sensor and instrumentation systems.
The AD7714 accepts three differential analog inputs that can also be configured as five pseudo-differential inputs. Its 24-bit conversion can achieve up to 24 bits of no-missing-code performance according to the manufacturer description. The device supports a single 3 V or 5 V supply, consumes approximately 500 µA, and accepts an external differential reference. These characteristics suit bridge sensors, pressure transducers, strain-gauge systems, and other slowly changing sensor signals.
Internally, the converter employs a sigma-delta conversion technique optimized for low-frequency measurement rather than high-speed waveform acquisition. Its serial interface transfers conversion results to a microcontroller or DSP. The differential input architecture helps reject common-mode noise when the source and return paths are laid out carefully. An external reference keeps the measurement system tied to a stable reference source, while programmable gain allows the converter to match a wide range of low-level transducer outputs.
Typical uses include industrial process monitoring, precision weighing, portable instrumentation, laboratory measurement, and smart sensor interfaces. The device is particularly appropriate when the required measurement bandwidth is low but resolution, input flexibility, and integrated signal conditioning are important. It is not intended for high-frequency sampling or audio waveform capture.
PCB design should prioritize a quiet analog ground, short input and reference traces, and separation from digital clocks and switching nodes. Place input and reference filtering capacitors close to their associated pins, and verify the complete transducer, reference, and acquisition chain against the required common-mode range and noise performance before production release.
This page organizes the AD7714YNZ electrical characteristics, application guidance, verified package information, lifecycle information, and available drop-in comparisons. It also separates published device facts from replacement decisions, helping engineers assess package, pin, supply, accuracy, and sampling-rate compatibility before committing to a board-level substitution.
直接替換替代品,適用於 AD7714YNZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD7714YNZ (相同外形與佔位) — 差異在於 Supply Voltage, Mounting Type, Reference Input, Converter Type, Input Type.
AD7714YN
✅ 直接替換聯絡詢價
查看資料表 →AD7714ACHIPS-3
✅ 直接替換📋 參考替代品(不在目錄中)
AD7714YNZ 最大額定值與電氣特性
| Converter Type | Sigma-delta ADC |
| 解析度 | 24 bit |
| 取樣率 | 1 kSPS |
| Differential Inputs | 3 |
| Pseudo-Differential Inputs | 5 |
| Input Type | Differential and pseudo-differential |
| Architecture | Sigma-delta |
| Reference Type | External differential reference |
| 供應電壓 | 3 V or 5 V single supply |
| 供應電流 | 500 µA |
| Process Technology | CMOS |
| 封裝 | 24-pin PDIP |
| Package Pitch | 0.300 in (7.62 mm) |
| 安裝類型 | Through hole |
| Digital Output | Serial |
| No-Missing-Code Performance | Up to 24 bits |
| Delivery Format | Tube |
AD7714YNZ 0.300 in (7.62 mm) 腳位配置指南
AD7714YNZ(0.300 in (7.62 mm) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD7714YNZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD7714YNZ 適用於 6 應用s: Industrial Pressure Transducer Interface, Precision Strain-Gauge Measurement, Portable Weighing System, Laboratory Sensor Instrumentation, Smart Sensor Node, Process Monitoring and Control.
Industrial Pressure Transducer Interface
The AD7714YNZ suits low-level bridge-based pressure measurements where slow variation favors a high-resolution sigma-delta converter. Its three differential inputs can be configured for five pseudo-differential channels, while the integrated signal-conditioning stage reduces the external circuitry required ahead of conversion. The 24-bit nominal resolution supports precise digital representation of narrow sensor spans, and the 1 kSPS rate is appropriate for temperature, pressure, and force readings that change gradually. In a practical circuit, the bridge excitation, differential sensor returns, and external reference should share a carefully controlled analog ground plan. Short protected traces and reference filtering are important because high resolution does not recover information lost through noise, poor grounding, or over-range inputs.
推薦
Precision Strain-Gauge Measurement
The AD7714YNZ is appropriate for strain-gauge bridges and similar millivolt-level sensors because it combines differential measurement, programmable signal conditioning, and 24-bit conversion in one package. The external differential reference allows the measurement scale to be tied to a stable excitation and reference arrangement. At a maximum conversion rate of 1 kSPS, the converter suits static loads, vibration-envelope monitoring, and slowly changing mechanical stress rather than high-frequency transient capture. Designers should confirm the sensor excitation voltage, bridge output range, analog input limits, and reference ratio before selecting gain settings. Keeping sensor wiring away from motor returns, switching nodes, and high-current ground paths helps preserve the low-level differential signal.
推薦
Portable Weighing System
The AD7714YNZ can serve as the measurement ADC in a portable scale or precision weighing platform where load-cell signals change slowly and battery power is constrained. Its approximately 500 µA supply current supports low-power acquisition, while the 24-bit resolution helps distinguish small load-cell changes from a common low-level bridge output. The 3 V or 5 V single-supply operation provides flexibility for portable electronics, and the 1 kSPS rate is sufficient for stable weight readings and filtered peak or average values. A practical implementation should use a dedicated analog section, low-noise reference wiring, and input protection suitable for the external connector environment. Firmware can apply calibration, tare, filtering, and drift compensation after conversion.
推薦
Laboratory Sensor Instrumentation
The AD7714YNZ fits laboratory instruments that acquire multiple low-level channels and require accurate conversion rather than high sampling bandwidth. Three differential inputs, five pseudo-differential configurations, and an external differential reference permit centralized acquisition from bridge, thermocouple-style, or resistive sensor front ends. The 24-bit sigma-delta architecture produces a serial digital result suitable for a microcontroller or DSP, allowing the host processor to perform calibration, diagnostics, and data logging. Because the converter is optimized for low-frequency signals, the application should include appropriate anti-alias filtering and must distinguish measurement bandwidth from the nominal conversion rate. Reference stability and input settling directly affect repeatability and should be validated with the complete analog chain.
推薦
Smart Sensor Node
The AD7714YNZ can form the sensing front end of a smart industrial or IoT sensor node that periodically reports slowly changing physical measurements. Its low 500 µA operating current and ability to run from 3 V or 5 V suit embedded acquisition, while the integrated signal conditioning reduces the number of discrete components around the transducer. The serial output is compatible with a low-power microcontroller or DSP that controls conversion timing and processes the digital result. Duty-cycled operation can further reduce system energy use, but the power-up settling, reference behavior, and filter settling time must be included in the measurement cycle. Firmware should reject readings during startup transients and use the device’s calibration features consistently for traceability.
推薦
Process Monitoring and Control
The AD7714YNZ is applicable to slow process variables such as pressure, level, flow proxy, or force in industrial monitoring systems. Multiple analog-input configurations allow several low-level sensors to share one converter when their bandwidth and grounding requirements are compatible. A 1 kSPS conversion rate provides periodic updates suitable for supervisory control loops, while the 24-bit resolution preserves detail in small measurement ranges. The external differential reference should be shared carefully and monitored for drift because it defines the conversion scale. Galvanic isolation, surge protection, and sensor wiring may require additional components outside the ADC. Commissioning should compare the converter output against a known reference, verify channel isolation, and characterize noise under the final power-supply and motor-environment conditions.
推薦
推薦產品摘要
工程參考資料,適用於 AD7714YNZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD7714YN | AD7714ACHIPS-3 | AD7731BN |
|---|---|---|---|---|
| Package | 24-pin PDIP | 24-pin PDIP | 24-pin PDIP | 24-pin PDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Resolution | 24 bit | 24 bit | 24 bit | 24 bit |
| Sampling Rate | 1 kSPS | 1 kSPS | 1 kSPS | 6.4 kSPS |
| Differential Inputs | 3 | 3 | 3 | 3 |
| Pseudo-Differential Inputs | 5 | 5 | 5 | 5 |
| Supply Voltage | 3 V or 5 V single supply | 3 V or 5 V single supply | 3 V or 5 V single supply | 3 V or 5 V single supply |
| Supply Current | 500 µA | 500 µA | 500 µA | 500 µA |
| Architecture | Sigma-delta | Sigma-delta | Sigma-delta | Sigma-delta |
主要差異化特點
- Lifecycle-preferred same-package replacement (對比AD7714YN)
- Higher conversion rate in the same PDIP family (對比AD7731BN)
- Complete low-frequency signal-conditioning integration (對比AD7714ACHIPS-3)
設計說明
Route the three differential analog inputs as tightly matched signal pairs, with the positive and negative paths following similar geometry and lengths. Keep the external reference and reference-decoupling network close to the device and away from digital return currents. Although the AD7714 has an integrated sigma-delta front end, PCB leakage, asymmetric impedance, and common-mode coupling can still degrade the low-level transducer signal before conversion.
Design the 3 V or 5 V supply path so the converter and reference network remain stable during conversion. Place the manufacturer-recommended decoupling capacitors at the associated supply pins and keep their return current out of sensitive input paths. Estimated: a 5 V supply and 3 V reference can create approximately 2 V of internal conversion headroom for the reference relationship, but the actual usable range must be checked against the selected gain, input voltage, and reference configuration.
Do not treat the 1 kSPS conversion rate as a universal signal bandwidth. The digital filter and analog front end determine useful response time, settling behavior, and rejection of unwanted noise. Allow the complete acquisition chain to settle after power-up, reference changes, input switching, or gain changes. Firmware should also distinguish a valid converted result from samples taken during these transient intervals.
Protect external sensor connections from electrostatic discharge and industrial transients with appropriately rated networks. Input protection components can introduce leakage or nonlinear capacitance, so their influence should be evaluated against the sensor impedance and required resolution. For long cable runs, use guarding, shielding, or differential isolation to prevent common-mode noise from exceeding the usable input range before the converter can reject it.
合規資訊
The available product information does not state RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification status for AD7714YNZ. The ADC is a digital and analog mixed-signal IC, not an automotive-qualified selection based on the published information.